• Title/Summary/Keyword: Load.

Search Result 36,288, Processing Time 0.071 seconds

Physiological Characteristics of Cardiopulmonary Function, Electromyogram and Blood Chemistry in Athletic High School Students (고등학교(高等學校) 운동선수(運動選手)의 심폐기능(心肺機能), 근전도(筋電圖) 및 혈액성분(血液成分)의 특성(特性))

  • Choo, Young-Eun;Lee, Won-Jung;Park, Jae-Sik;Kim, Hyeong-Jin;Hwang, Soo-Kwan
    • The Korean Journal of Physiology
    • /
    • v.18 no.1
    • /
    • pp.67-79
    • /
    • 1984
  • In an effort to elucidate the physiological characteristics in cardiopulmonary function, electromyogram(EMG), and blood chemistry in athletic high school students, an analysis of electrocardiogram(ECG) and EMG, pulmonary function test, venous blood gas analysis($Pvo_2$ and$Pvco_2$), and measurement of heart rate, blood pressure, respiratory rate, blood glucose and blood lactate were made for 16 to 19 year-old high school students who were divided into athletic (n=19) and non-athletic (n=20) group. The results obtained are summarized as follows. 1) ECG intervals in athletes were longer than in non-athletes, and the difference was significant in R-R, Q-T and T-P intervals. Resting heart rate in athletes was 56.3/min showing a bradycardia compared with 79.8/min in non-athletes. Amplitudes of R and T waves in lead $V_5$ were significantly higher than in non-athletes. 2) Pulmonary function parameters in athletes showed higher values than in non-athletes. Parameters which showed significant differences were FEV 0.5, PEF, FEF 25%, PIF and FEF $200{\sim}1.200\;ml. 3) Heart rate, blood pressure, and respiratory rate after exercise were significantly elevated from resting values. Heart rate and respiratory rate showed greater increase in non-athletes, while blood pressure showed greater increase in athletes. 4) $Pvo_2$ was lowered ana $Pvco_2$ was elevated after exercise, and there was no significant difference between two groups. 5) Blood glucose and lactate levels were elevated after exercise. The difference was significant in blood lactate, and was greater in non-athletes. 6) EMG amplitude was steadily increased with increasing load of exercise, and the increase was greater in athletes than in non-athletes.

  • PDF

Evaluation on Thermal Performance Along with Constructability and Economic Feasibility of Large-diameter Cast-in-place Energy Pile (대구경 현장타설 에너지파일의 열교환 성능과 시공성 및 경제성 분석)

  • Park, Sangwoo;Sung, Chihun;Lee, Dongseop;Jung, Kyoungsik;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.5
    • /
    • pp.5-21
    • /
    • 2015
  • An energy pile is a novel type of ground heat exchangers (GHEX's) which sets up heat exchange pipes inside a pile foundation, and allows to circulate a working fluid through the pipe for exchanging thermal energy with the surrounding ground stratum. Using existing foundation structure, the energy pile can function not only as a structural foundation but also as a GHEX. In this paper, six full-scale energy piles were constructed in a test bed with various configurations of the heat exchange pipe inside large-diameter cast-in-place piles, that is, three parallel U-type heat exchangers (5, 8 and 10 pairs), two coil type heat exchangers (with a 500 mm and 200 mm pitch), and one S-type heat exchanger. During constructing the energy piles, the constructability of each energy pile was evaluated with consideration of the installation time, the number of workers and any difficulty for installing. In order to evaluate the thermal performance of energy piles, the thermal performance tests were carried out by applying intermittent (8 hours operating-16 hours pause) artificial cooling operation to simulate a cooling load for commercial buildings. Through the thermal performance tests, the heat exchange rates of the six energy piles were evaluated in terms of the heat exchange amount normalized with the length of energy pile and/or the length of heat exchange pipe. Finally, the economic feasibility of energy pile was evaluated according to the various types of heat exchange pipe by calculating demanded expenses per 1 W/m based on the thermal performance test results along with the market value of heat exchange pipes and labor cost.

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

Fracture resistance and marginal fidelity of zirconia crown according to the coping design and the cement type (코핑 디자인과 시멘트에 따른 지르코니아 도재관의 파절 저항성)

  • Sim, Hun-Bo;Kim, Yu-Jin;Kim, Min-Jeong;Shin, Mee-Ran;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.194-201
    • /
    • 2010
  • Purpose: The purpose was to compare the marginal fidelity and the fracture resistance of the zirconia crowns according to the various coping designs with different thicknesses and cement types. Materials and methods: Zirconia copings were designed and fabricated with various thicknesses using the CAD/CAM system (Everest, KaVo Dental GmbH, Biberach., Germany). Eighty zirconia copings were divided into 4 groups (Group I: even 0.3 mm thickness, Group II: 0.3 mm thickness on the buccal surface and the buccal half of occlusal surface and the 0.6 mm thickness on the lingual surface and the lingual half of occlusal surface, Group III: even 0.6 mm thickness, Group IV: 0.6 mm thickness on the buccal surface and the buccal half of occlusal surface and the 1.0 mm thickness on the lingual surface and the lingual half of occlusal surface) of 20. By using a putty index, zirconia crowns with the same size and contour were fabricated. Each group was divided into two subgroups by type of cement: Cavitec$^{(R)}$ (Kerr Co, USA) and Panavia-$F^{(R)}$ (Kuraray Medical Inc, Japan). After the cementation of the crowns with a static load compressor, the marginal fidelity of the zirconia crowns were measured at margins on the buccal, lingual, mesial and distal surfaces, using a microscope of microhardness tester (Matsuzawa, MXT-70, Japan, ${\times}100$). The fracture resistance of each crown was measured using a universal testing machine (Z020, Zwick, Germany) at a crosshead speed of 1 mm/min. The results were analyzed statistically by the two-way ANOVA and oneway ANOVA and Duncan's multiple range test at $\alpha$=.05. Results: Group I and III showed the smallest marginal fidelity, while group II demonstrated the largest value in Cavitec$^{(R)}$ subgroup (P<.05). For fracture resistance, group III and IV were significantly higher than group I and II in Cavitec$^{(R)}$ subgroup (P<.05). The fracture resistances of Panavia-$F^{(R)}$ subgroup were not significantly different among the groups (P>.05). Panavia-$F^{(R)}$ subgroup showed significantly higher fracture resistance than Cavitec$^{(R)}$ subgroup in group I and II (P<.05). Conclusion: Within the limitation of this study, considering fracture resistance or marginal fidelity and esthetics, a functional ceramic substructure design of the coping with slim visible surface can be used for esthetic purposes, or a thick invisible surface to support the veneering ceramic can be used depending on the priority.

CHANGES IN THE SHAPE AND ULTRASTRUCTURE OF THE ARTICULAR DISK OF RAT FOLLOWING POSTURAL HYPERPROPULSOR (백서 하악골의 기능적 전방위가 악관절 원판에 미치는 영향)

  • Jang, Byung-Chun;Kyung, Hee-Moon;Sung, Jae-Hyun;Bae, Yong-Chul
    • The korean journal of orthodontics
    • /
    • v.24 no.4 s.47
    • /
    • pp.917-932
    • /
    • 1994
  • This study was conducted to examine the changes in the shape of the Sprague-Dawley rats' articular disk following postural hyperpropulsion by observing their articular specimens through light and electronic microscopes after following 2-week and 4-week postural hyperpropulsion from their four weeks of age. The findings of this study are summarized as follows. It was shown that as compared with the control group, the experimental group indicated a significant increase in thickness of the 2-week groups' anterior and postreior portion of the articular disc. The experimental group showed statistically more significant increase in thickness of the 4-week groups' anterior portion of the articular disc than the control group. Light micrograph showed that the experimental group had more fibroblast in the anterior portion of the 2-week and 4-week groups than the comparing group. The 2-week groups showed in the findings through the electronic microscope that there were found the well developed and dilated RER which seems to actively synthesize the extracellular matrix including collagen, the cells with the well developed RER without distention which seems to actively synthesize the intracellular microfilaments due to the well developed free ribosome, and the typical chondroid cells. In addition, there was more fibroblast cell with the distended and well developed RER in the anterior area of the experimental group than that of the control group. The 4 week experimental group's anterior area of the disk had more cells than that of the control group while fibroblast with the well developed RER and free ribosome was quite abundat. Based on the above result of this study, it was shown that the functional hyperpropulsion of the mandible causes the changes in the nature of the mechanical load to the certain portion of the articular disk. As a result, it seems that there may be occurred some changes in morphology of the disc by adaptation or confrontation with these changes at the cellular level.

  • PDF

A Study on Performance and Achievement of Village Health Workers in Rural Primary Health Care Program (농촌 일차 보건사업에 있어서 마을건강원 업무량 및 업적에 관한 연구)

  • Hur, Dal-Young;Lee, Myoung-Sook;Yum, Yong-Tae;Kim, Soon-Duck
    • Journal of agricultural medicine and community health
    • /
    • v.12 no.1
    • /
    • pp.36-53
    • /
    • 1987
  • It is utmostly important to establish the efficient fitable way of peoples' active participation in primary health care especially in the areas where the public or governmental service input for the basic health care is insufficient like as in rural areas of Korea. In light of above reason, this study focused mainly on the evaluation of roles and activities of village health workers (VHWs) who were selected from grass- root level of village people in order to derive further motivation for active participation. This is believed to be a sort of feedback mechanisms. Actually, the authors collected the activity reports of VHWs who had been devoting themselves in the primary health care services of Jeomdong Area, of Yeoju Gun one of Korea University Community Health Action Programmes and survey record on the VHWs activity from correspondent people. 1 hose data were analyzed through computer programmed package. The activities performed by VHWs were limited to the performance in 1985 for conveniance. The summarized results were as follows; 1) General characteristics of VHWs. Among a total of 28 VHWs in the area, about 39.3g of them have been replaced up to the date since the implementation in 1983, because of moving out, occupational employment and of others. The age of majority (75.0%) lied between the range of 30-50, and educational background of 67.9% belonged to category of primary school graduation, about 50% of them experienced to be or were also entiled "chief of women club" of corresponding villages. 2) Work-load of VHWs. Each VHW was assigned for tasks of health care for average 55 households of 248 persons. They shared approximately 6 days a month for the activity in average and it covered 17 cases of basic health care in a month. A half of the VHWs performed home visits irregularly without solidified schedule. 3) Work performance analysis. Informations collected through VHWs were compared with data from official vital registration at local administration center "Myon Office" in 1985. VHWs collected 100.8 of new born, 116.2 of death, 58.3 of move in and 74.8 of move out in comparison with 100.0 of official registration each. Pregnant women of 79.8% of mothers among the total pregnancy of 94 which were confirmed as normally delivered or aborted cases by all means afterwards had been detected by VHWs as being pregnant and all of them received some of antenatal cares by VHWs. All(100%) of delivered women were detected by VHWs through home visits and they were cared postnatally. Whereas, according to the records of birth registration, the places of delivery were clinic in 33.7%, and mother's home in 66.3%, VHWs reported them to be clinic in 48.9%, midwifery in 20.2%. It was cleared that most of misinformation was caused by uncautious filling of birth registration at notification. Among the total of 717 eligible women under age 44 years, family planning status of 92.6% was reported by VHWs confirming practice of control to be 70.8% of reported fertile women. 4) Attitude of VHW on the roles and functions. Although 92.0% of VHWs expressed VHWs to be worthwhile, only 52.0% of them had dignity and satisfaction in their activity and 44.0% of them had passive attitude of working saying they followed direction regardlessly. Concerning difficulties in performance as a VHW, 60.7% of them pointed out lacking of medical and health related knowledge by themselves. Still, 64.0% of them thought visiting unfamilier house to be awful and 40.0% complained forms of activity to be difficult and hard. It was also revealed that 56.6% confessed lack of interest on community health service itself. Most of VHWs needed more educational training especially on clinical fields such as cares of gynecological diseases, hypertension, diabetes, and other chronic diseaes of the aged. Regular on-the-job basic trainings were said to be needed twice a year.

  • PDF

DEVELOPMENTAL AND CLINICAL CHARACTERISTICS IN CHILDREN WITH NOCTURNAL ENURESIS : RESULTS OF A MULTICENTER STUDY (야뇨증 환아들의 심리사회적 특성에 대한 다기관 연구 : 발달학적 및 임상적 특성을 중심으로)

  • Cho Soo-Churl;Shin Min-Sup;Hwang Jun-Won;Han Sang-Won;Park Kwan-Hyun;Lee Sang-Don;Kim Kyung-Do;Kim Kun-Suk;Suh Hong-Jin;Lee Yoo-Sik;Chung Jae-Yong;Kim Young-Kyoon;Kim Jae-Won
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.17 no.1
    • /
    • pp.32-39
    • /
    • 2006
  • Objectives : The aim of this study was to examine the developmental and clinical characteristics associated with nocturnal enuresis in Korean children. Methods : Three hundred eighteen children with nocturnal enuresis, together with their parents, completed a parent questionnaire consisting of a Child Behavior Checklist(CBCL). Data related to the prenatal, perinatal and developmental history, past and current medical history were collected. Ninety-three normal students were selected as the control group. Results : The nocturnal enuresis group attained diurnal and nocturnal urinary control significantly later than those in the normal control group.49.2% of the children with nocturnal enuresis had the family history of nocturnal enuresis. Daytime incontinence was present in 41.3% of the nocturnal enuresis group. The percentages of sleep-related disturbances were significantly higher in the nocturnal enuresis group when compared to the normal control group.42.6% of the children with nocturnal enuresis experienced pharmacotherapy, and 0.4% experienced enuresis alarms. Conclusion : The results of this study suggest that children with nocturnal enuresis in Korea have a high genetic load and a possibility of developmental delay, which supports the neurodevelopmental point of view with regard to the etiology of nocturnal enuresis. The physicians in Korea prefer pharmacological interventions to alarm interventions in treating Korean children with nocturnal enuresis.

  • PDF

Photocatalytic Treatment of Waste Air Containing Malodor and VOC by Photocatalytic Reactor Equipped with the Cartridges Containing the Media Carrying Photocatalyst (광촉매 카트리지를 활용한 악취 및 VOC를 함유한 폐가스의 광촉매처리)

  • Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.51 no.1
    • /
    • pp.80-86
    • /
    • 2013
  • In this study, the photocatalytic reactor system equipped with photocatalyst-carrying-silica-media cartridges [photocatalytic reactor system (1)] was used to perform the treatment of waste air containing malodor and volatile organic compound (VOC). The result of its performance was evaluated and compared with that of the photocatalytic reactor system equipped with commercial photocatalyst-carrying-nonwoven filter-media cartridges [photocatalytic reactor system (2)]. In case of photocatalytic reactor system (1), at the 1st stage of run the removal efficiencies of ethanol and toluene continued to be 80% and 20%, respectively. However, unlike toluene, the removal efficiency of ethanol dropped to 40% at the end of the 1st stage of run. The removal efficiency of hydrogen sulfide decreased from 100% to 90%. At the 2nd stage of its run the removal efficiency of ethanol decreased to 10% while the removal efficiencies of hydrogen sulfide and toluene remained as same as 90% and 20%, respectively, even though the inlet load of toluene increased by factor of four. In the 3rd stage of its run, as the result of application of aluminium-coated reflector film to the inner wall of photocatalytic reactor system, the removal efficiencies of ethanol and toluene increased by 5% to be 15% and 25%, respectively. In case of photocatalytic reactor system (2), at the 1st stage of its run, the removal efficiencies of ethanol, hydrogen sulfide and toluene continued to be 10%, 97% and 100%, respectively. However, at 2nd stage of its run their removal efficiencies became 5%, 95% and 2~3%, respectively, which showed that the removal efficiencies of ethanol and hydrogen sulfide decreased insignificantly while the removal efficiency of toluene dropped significantly from the perfect elimination. Moreover, the reflector film did not affect the performance of photocatalytic reactor system (2) at all. Therefore the removal of ethanol, hydrogen sulfide and toluene by photocatalytic reactor system (2) was mainly attributed to hydrophobic adsorption of its nonwoven filter media and its extent of photocatalytic removal turned out to be negligible, compared to that of photocatalytic reactor system (1).

Relationship between Compressive Strength and Dynamic Modulus of Elasticity in the Cement Based Solid Product for Consolidating Disposal of Medium-Low Level Radioactive Waste (중·저준위 방사성 폐기물 처리용 시멘트 고화체의 압축강도와 동탄성계수의 관계)

  • Kim, Jin-Man;Jeong, Ji-Yong;Choi, Ji-Ho;Shin, Sang-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.321-329
    • /
    • 2013
  • Recently, the medium-low level radioactive waste from nuclear power plant must be transported from temporary storage to the final repository. Medium-low level radioactive waste, which is composed mainly of the liquid ion exchange resin, has been consolidated with cementitious material in the plastic or iron container. Since cementitious material is brittle, it would generate cracks by impact load during transportation, signifying leakage of radioactive ray. In order to design the safety transporting equipment, there is a need to check the compressive strength of the current waste. However, because it is impossible to measure strength by direct method due to leakage of radioactive ray, we will estimate the strength indirectly by the dynamic modulus of elasticity. Therefore, it must be identified the relationship between of strength and dynamic modulus of elasticity. According to the waste acceptance criteria, the compressive strength of cement based solid is defined as more than 3.44 MPa (500 psi). Compressive strength of the present solid is likely to be significantly higher than this baseline because of continuous hydration of cement during long period. On this background, we have tried to produce the specimens of the 28 day's compressive strength of 3 to 30 MPa having the same material composition as the solid product for the medium-low level radioactive waste, and analyze the relationship between the strength and the dynamic modulus of elasticity. By controling the addition rates of AE agent, we made the mixture containing the ion exchange resin and showing the target compressive strength (3~30 MPa). The dynamic modulus of elasticity of this mixtures is 4.1~10.2 GPa, about 20 GPa lower in the equivalent compressive strength level than that of ordinary concrete, and increasing the discrepancy according to increase strength. The compressive strength and the dynamic modulus of elasticity show the liner relationship.

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.