• Title/Summary/Keyword: Load stimulation

Search Result 29, Processing Time 0.022 seconds

Treatment Stimulator's Pulse of Transcranial Magnetic Stimulation (경두개 자기자극장치의 치료자극 펄스)

  • Kim, Whi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.289-296
    • /
    • 2009
  • In this study, I presented power control unit with potential use in the magnetic stimulation of biological systems. The effect of the magnetic stimulation depends on the geometry and orientation of the induced electric field as well as on the current pulse waveform delivered by the stimulator coil. TMS is achieved from the outside of the head using pulses of electromagnetic field that induce an electric field in the brain. There are numerous possibities in the applications TMS, such as diagnosis and therapy through the brain stimulation. These factors are very important to define the equipment requirements and characteristics in that the topology of the power supply and the size and geometry of the coil. The proposed solution is the generation of current pulses with variable amplitude and duration, according to a user defined input. Another solution is the topology that uses elements to store and transfer energy from the power source to the load. In addition to proposed topology, an adequate control strategy and right set of the power circuit parameters made possible to obtain unipolar waves and bipolar waves.

Development of the off-vertical rotatory chair and visual stimulation system for evaluation of the vestibular function (전정기능 평가를 위한 탈수직축 회전자극 시스템 및 HMD 시스템의 개발)

  • 김규겸;고종선;박병림;김인동
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.325-332
    • /
    • 2001
  • The vestibular system located in the inner ear controls reflex body posture and movement, It has the semicircular canals sensing an angular acceleration and the otolith organs sensing a linear acceleration. With this organic signal, medical doctor decide if a person has disease or not. To obtain this data, a precision stimular system is considered. Robust control is needed to obtain eye signals induced by off-vertical axis rotation because of an unbalanced load produced by tilting the axis of the system upto 30 degrees. In this study, off-vertical axis rotatory system with visual stimulation system are developed. This system is consisted of head mounted display for generating horizontal, vertical, and three dimensional stimulus patterns. Furthermore wireless recording system using RF modem is considered for noiseless data transmission. Detailed data was described.

  • PDF

Precision Speed Control of PMSM for Stimulation of the Vestibular System Using Rotatory Chair (전정기관 자극용 회전자극기를 취한 PMSM의 정밀 속도제어)

  • 고종선;이태호;박병림;전칠환
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.459-466
    • /
    • 2000
  • A new control method for precision robust speed control of a PMSM(Permanent Magnet Synchronous Motor) using load torque observer is presented. Using this system, we can more precisely evacuate of vestibular function. Until now a rotating chair system, so called 2D-stimulator, which has vertical rotate axis is used to make dizziness. However, an inclined rotating chair system witch is called 3D-stimulator is needed to obtain the precise dizziness data. This 3D-stimulator include unbalanced load caused by unbalanced center of mass. In this case, new compensation method is considered to obtain robust speed control using load torque observer. To reduce the effect of this disturbance, we can use dead-beat observer that has high gain. The application of the load to torque observer is published in for position control. However, there is a problem of using speed information such as amplifying effect of noise. Therefore, we can reduce a noise effect by moving average process. The experimental results are depicted in this paper to show the effect of this proposed algorithm.

  • PDF

Blood Glucose-Lowering Effects of Mori Folium (상엽의 혈당강하 활성)

  • 이주선;최명현;정성현
    • YAKHAK HOEJI
    • /
    • v.39 no.4
    • /
    • pp.367-372
    • /
    • 1995
  • Mori Folium(MF) methanol extract and its water soluble fraction showed significant blood glucose lowering effects alloxan-induced hyperglycemic mice. Their hypoglycemic activities seemed to nothing to do with the stimulation of insulin release or insulin-like action, according to our experiments. On the other hand, MF prevents the hyperglycemic responses from an oral load of starch and glucose in vivo. Since complex carbohydrates present in a diet must be degraded to monosaccharides by $\alpha$-glucohydrolase before being absorbed in the gastrointestinal tract, it is thought that blood glucose lowering effects of MF may be related to the inhibition of $\alpha$-glucohydrolase catalyzed enzymatic reaction. In addition, experiments that examined an effect of MF water soluble fraction on gastrointestinal movement showed no significant GI movement inhibitory effect. In conclusion, MF water soluble fraction may possess active component which is a potential candidate as an orally active agent for the treatment of diabetes mellitus.

  • PDF

A Study on Development of Disney Animation's Box-office Prediction AI Model Based on Brain Science (뇌과학 기반의 디즈니 애니메이션 흥행 예측 AI 모형 개발 연구)

  • Lee, Jong-Eun;Yang, Eun-Young
    • Journal of Digital Convergence
    • /
    • v.16 no.9
    • /
    • pp.405-412
    • /
    • 2018
  • When a film company decides whether to invest or not in a scenario is the appropriate time to predict box office success. In response to market demands, AI based scenario analysis service has been launched, yet the algorithm is by no means perfect. The purpose of this study is to present a prediction model of movie scenario's box office hit based on human brain processing mechanism. In order to derive patterns of visual, auditory, and cognitive stimuli on the time spectrum of box office animation hit, this study applied Weber's law and brain mechanism. The results are as follow. First, the frequency of brain stimulation in the biggest box office movies was 1.79 times greater than that in the failure movies. Second, in the box office success, the cognitive stimuli codes are spread evenly, whereas in the failure, concentrated among few intervals. Third, in the box office success movie, cognitive stimuli which have big cognition load appeared alone, whereas visual and auditory stimuli which have little cognitive load appeared simultaneously.

A Study on the Evaluation of the Impact of Power System according to the Connection of Renewable Energy (신재생 전원 계통 접속에 따른 전력계통 영향 평가에 관한 연구)

  • Park, Seoung-Jun;Cho, Yun-Sung;Hur, Jin;Park, Sang Ho;Yoon, Gi Gab
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.733-737
    • /
    • 2018
  • In this paper, we describe the effects on the power system by adding renewable generator. In order to examine the stability of the system, the system analysis was performed using the PSS/E software. We confirmed whether occur the line overload of system through the load flow analysis and contingency analysis. and confirmed whether exceed of fault current using the fault current analysis. Dynamic stability of the system is analyzed through dynamic simulation. The analysis of the system according to the addition of the renewable generator was carried out according to the power system reliability and electricity quality maintenance standard.

Triticum aestivum (Wheatgrass) formulation: An alternate treatment for the patients with Thalassemia

  • Desai, TR;Solanki, JK;Buch, Pankaj;Goyal, RK
    • Advances in Traditional Medicine
    • /
    • v.7 no.5
    • /
    • pp.466-476
    • /
    • 2008
  • We have developed the tablet formulation of Triticum aestivum (wheatgrass) and investigated clinically, its effects in patients suffering from b-thalassemia (major) at K. T. Children Hospital, Civil Hospital, Rajkot. The tablets (wheatgrass powder 250 mg.) were given 3 times in a day for 9 months. Blood samples were collected at the start, after 6 months and 9 months and analyzed for various biochemical and hematological parameters. Treatment with wheatgrass formulation for 9 months produced significant decrease in hemoglobin, total RBC, eosinophil and reticulocyte counts. The mean corpuscular volume (MCV) and mean corpuscular hemoglobin concentration (MCHC) were significantly increased was significantly increased. The serum ferritin was also significantly decreased. There was no influence on serum magnesium, serum iron and Thiobarbituric acid reacting substances (TBARS). Our data indicate that treatment with wheatgrass on patients with $\beta$-thalassemia (major) may have beneficial effects in the form of a decrease in ineffective erythropoiesis, stimulation of hemoglobin synthesis in RBC, decrease in iron load and decrease in eosinophil count.

Identification of the Mechanical Resonances of Electrical Drives for Automatic Commissioning

  • Pacas Mario;Villwock Sebastian;Eutebach Thomas
    • Journal of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.198-205
    • /
    • 2005
  • The mechanical system of a drive can often be modeled as a two- or three-mass-system. The load is coupled to the driving motor by a shaft able to perform torsion oscillations. For the automatic tuning of the control, it is necessary to know the mathematical description of the system and the corresponding parameters. As the manpower and setup-time necessary during the commissioning of electrical drives are major cost factors, the development of self-operating identification strategies is a task worth pursuing. This paper presents an identification method which can be utilized for the assisted commissioning of electrical drives. The shaft assembly can be approximated as a two-mass non-rigid mechanical system with four parameters that have to be identified. The mathematical background for an identification procedure is developed and some important implementation issues are addressed. In order to avoid the excitation of the system with its natural resonance frequency, the frequency response can be obtained by exciting the system with a Pseudo Random Binary Signal (PRBS) and using the cross correlation function (CCF) and the auto correlation function (ACF). The reference torque is used as stimulation and the response is the mechanical speed. To determine the parameters, especially in advanced control schemes, a numerical algorithm with excellent convergence characteristics has also been used that can be implemented together with the proposed measurement procedure in order to assist the drive commissioning or to achieve an automatic setting of the control parameters. Simulations and experiments validate the efficiency and reliability of the identification procedure.

Characterization of 3D Printed Re-entrant Strips Using Shape Memory Thermoplastic Polyurethane with Various Infill Density (채우기 밀도별 형상 기억 TPU 3D 프린팅 Re-entrant 스트립의 특성 분석)

  • Imjoo Jung;Sunhee Lee
    • Fashion & Textile Research Journal
    • /
    • v.24 no.6
    • /
    • pp.812-824
    • /
    • 2022
  • This study proposes to develop a 3D printed re-entrant(RE) strip by shape memory thermoplastic polyurethane that can be deformed and recovered by thermal stimulation. The most suitable 3D printing infill density condition and temperature condition during shape recovery for mechanical behavior were confirmed. As the poisson's ratio indicated, the higher the recovery temperature, the closer the poisson's ratio to zero and the better the auxetic properties. After recovery testing for five minutes, it appeared that the shape recovery ratio was the highest at 70℃. The temperature range when the shape recovery ratio appeared to be more than 90% was a recovery temperature of more than 50℃ and 60℃ when deformed under a constant load of 100 gf and 300 gf, respectively. This indicated that further deformation occurred after maximum recovery when recovered at a temperature of 80℃, which is above the glass transition temperature range. As for REstrip by infill density, a shape recovery properties of 100% was superior than 50%. Additionally, as the re-entrant structure exhibited a shape recovery ratio of more than 90%, and exhibited auxetic properties. It was confirmed that the infill density condition of 100% and the temperature condition of 70℃ are suitable for REstrips for applying the actuator.

Measurement of Vestibular Ocular Reflex in Normal Subjects Using Galvanic Stimulator and Videooculograph (전기자극과 VOG(Videooculograph)를 이용한 정상인의 전정 안반사 측정)

  • 김수찬;정운교;남기창;이원상;김영하;김덕원
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.487-496
    • /
    • 2001
  • In this study, a galvanic stimulator providing bipolar mode controlled by a PIC(peripheral interface controller) was constructed to evaluate vestibular function The maximum load and maximum current intensity of the constant current source were 3$k\Omega$ and 5mA. respectively. and it could Produce DC, sine wavers. or Pulse waves. Eve movements of 20 normal subjects by galvanic stimulation were analyzed using a commercial videooculogragh. During stimulating with DC for 30 sec. we recorded the response of eye movement with current intensity of 0.75. 1 2, and 3 mA. Nystagmus occurred to all the subjects when the galvanic stimulus intensity was larger than 2 mA. Average SPV(slow Phase eye movement velocity) and the number of nystagmus increased from 7.1 to 4.8 deg/sec and from 17 to 48, respectively, when the stimulus current increased from 0.75 to 3 mA. All the fast eye movement of the nystagmus were the direction of the negative electrode. The asymmetry which means the difference between right- and left-eye movements decreased when the stimulus intensity increased. It is expected that this study would be useful in evaluating vestibular function and in studying basic Physiology mechanism of vestibular ocular reflex by galvanic stimulus .

  • PDF