• Title/Summary/Keyword: Load case

Search Result 3,586, Processing Time 0.031 seconds

Evaluation of Support Performance of Fiber-Net Integrated Shotcrete in Tunnel Support System (숏크리트용 섬유 그물망 일체형 터널 지보시스템의 지보 성능 평가)

  • Kim, Jiyoung;Choi, Seongcheol
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.545-552
    • /
    • 2020
  • This study evaluated the support performance of fiber-net integrated shotcrete in tunnel support system developed for the purpose of improving constructability and stability while fully performing its mechanical performance as a tunnel support materials by four-point bending test, two-dimensional numerical analysis, and cross-sectional analysis. As a result of evaluating the flexural performance through a four-point bending test, in the case of fiber-net reinforced shotcrete, the tensile performance of fiber-net resulted in a continuous increase in load after crack occurrence, unlike steel fiber reinforced shotcrete. Also, the results of the tunnel cross-sectional structure analysis for ground conditions and the cross-sectional analysis of fiber-net and steel fiber reinforced shotcrete showed that sufficient support performance can be exhibited even if the thickness of fiber-net reinforced shotcrete was reduced compared to the previous one. Additionally, through these results, the support pattern of fiber-net integrated shotcrete in tunnel support system, which can be applied efficiently to the construction sections requiring higher stability among the rock mass class III, was proposed.

Bending analysis of functionally graded plates using a new refined quasi-3D shear deformation theory and the concept of the neutral surface position

  • Hachemi, Houari;Bousahla, Abdelmoumen Anis;Kaci, Abdelhakim;Bourada, Fouad;Tounsi, Abdeldjebbar;Benrahou, Kouider Halim;Tounsi, Abdelouahed;Al-Zahrani, Mesfer Mohammad;Mahmoud, S.R.
    • Steel and Composite Structures
    • /
    • v.39 no.1
    • /
    • pp.51-64
    • /
    • 2021
  • This paper presents a high-order shear and normal deformation theory for the bending of FGM plates. The number of unknowns and governing equations of the present theory is reduced, and hence makes it simple to use. Unlike any other theory, the number of unknown functions involved in displacement field is only four, as against five or more in the case of other shear and normal deformation theories. Based on the novel shear and normal deformation theory, the position of neutral surface is determined and the governing equilibrium equations based on neutral surface are derived. There is no stretching-bending coupling effect in the neutral surface-based formulation, and consequently, the governing equations of functionally graded plates based on neutral surface have the simple forms as those of isotropic plates. Navier-type analytical solution is obtained for functionally graded plate subjected to transverse load for simply supported boundary conditions. The accuracy of the present theory is verified by comparing the obtained results with other quasi-3D higher-order theories reported in the literature. Other numerical examples are also presented to show the influences of the volume fraction distribution, geometrical parameters and power law index on the bending responses of the FGM plates are studied.

Characteristics of Non-point Pollution Runoff in Mandae, Gaa, and Jaun Districts and Evaluation of Reduction Projects (만대·가아·자운지구 비점오염 유출특성 분석 및 저감사업 평가)

  • Woo, Soo-Min;Kum, Dong-Hyuk;Hong, Eun-Mi;Lim, Kyoung-Jae;Shin, Min-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.1
    • /
    • pp.65-77
    • /
    • 2022
  • Due to muddy water from the highland fields upstream of Soyangho Lake, the Mandae, Gaa, and Jawoon have been redesignated as NPS management areas. This study aims to evaluate the adequacy and supplementation points of the implementation plan by analyzing the operation status of muddy water generation and reduction facilities through on-site investigations by NPS management area to achieve the effective nonpoint pollution reduction goal in the implementation of the implementation plan established in 2020. The SS load calculated based on the survey results from July to October 2019 from 2017 showed a decreasen in 2019 compared to 2017. Both and the Jawoon were analyzed to have decreased. However, the amount of precipitation also decreased by about 27%, so it was judged that the effect of the reduction project was not significant. As a result of the detailed investigation of abatement facilities, about 86% of the 793 facilities installed in the management area were evaluated as 'good'. As a result of a detailed investigation by subwatersheds, subwatersheds 105 and 106 in the Mandae were analyzed as apprehensive subwatersheds. appeared to fall. In addition, it was analyzed that the effect of reducing muddy water in the Mandae district was insufficient due to the high ratio of leased farmers, lack of efforts to reduce turbid water in leased farmland, conversion to annual crops, and neglect of bare land. In the case of Gaa district, although the abatement facilities are concentrated in the upstream, muddy water was also found to be severe.

Small Scale Modelling Experiments for Evaluating Lateral Resistance of Block-Type Breakwater II: A Single Block Reinforced with Piles under Cyclic Lateral Loads (블록식 방파제의 수평저항력 평가를 위한 실내모형실험 II : 보강형 싱글블럭의 반복수평 하중에 대한 저항)

  • Kang, Gichun;Kim, Jiseong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.4
    • /
    • pp.105-112
    • /
    • 2021
  • In the case of harbor structures, it is important to understand the characteristics of structures that are subjected to repeated loads as they are structures that receive repetitive loads such as wave pressure as well as static loads. In this study, the lateral resistance according to the pile embeded depth of the block breakwater reinforced with piles by cyclic lateral loads was obtained through an model experiment. As the depth of embedment of the pile increased, the lateral resistance showed a tendency to increase. As the load was repeated, the gradient of the lateral resistance gradually appeared to be gentle. The bending moment of the rear pile was larger than that of the front pile. The bending moment of piles in the ground was similar to that when the pile head was free in the cohesionless of Broms (1964).

Evaluation of Brinell Hardness of Coated Surface Using Finite Element Analysis: Part 3 - Application to Multilayer Coatings (유한요소해석에 의한 코팅면의 브리넬 경도 평가: 제3보 - 다층 코팅에 적용)

  • Park, TaeJo;Kang, JeongGuk
    • Tribology and Lubricants
    • /
    • v.37 no.6
    • /
    • pp.240-245
    • /
    • 2021
  • Ceramic coatings with high hardness and excellent chemical stability have been successfully applied to various machine elements, tools, and implants. However, in the case of monolayer coating on soft substrates, a high-stress concentration at the interface between the coating and the substrate causes delamination of the coating layer. Recently, to overcome this problem, multilayer coatings with a metal layer with a low modulus of elasticity added between the ceramic and the substrate have been widely applied. This study presents the third part of a recent study and focuses on the effect of the number of coating layers on the Brinell hardness of multilayered coating with TiN/Ti, following the two previous studies on a new Brinell hardness test method for a coated surface and on the influence of substrate and coating thickness. Indentation analyses are performed using finite element analysis software, von Mises stress and equivalent plastic strain distributions, load-displacement curves, and residual indentation shapes are presented. The number of TiN/Ti layers considerably affect the stress distributions and indentation shapes. Moreover, the greater the number of TiN/Ti layers, the higher is the Brinell hardness. The stress and plastic strain distributions confirm that the multilayer coatings improve the wear resistance. The results are expected to be used to design and evaluate various coating systems, and additional study is required.

A Design of File Leakage Response System through Event Detection (이벤트 감지를 통한 파일 유출 대응 시스템 설계)

  • Shin, Seung-Soo
    • Journal of Industrial Convergence
    • /
    • v.20 no.7
    • /
    • pp.65-71
    • /
    • 2022
  • With the development of ICT, as the era of the 4th industrial revolution arrives, the amount of data is enormous, and as big data technologies emerge, technologies for processing, storing, and processing data are becoming important. In this paper, we propose a system that detects events through monitoring and judges them using hash values because the damage to important files in case of leakage in industries and public places is serious nationally and property. As a research method, an optional event method is used to compare the hash value registered in advance after performing the encryption operation in the event of a file leakage, and then determine whether it is an important file. Monitoring of specific events minimizes system load, analyzes the signature, and determines it to improve accuracy. Confidentiality is improved by comparing and determining hash values pre-registered in the database. For future research, research on security solutions to prevent file leakage through networks and various paths is needed.

VDI deployment and performance analysys for multi-core-based applications (멀티코어 기반 어플리케이션 운용을 위한 데스크탑 가상화 구성 및 성능 분석)

  • Park, Junyong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.10
    • /
    • pp.1432-1440
    • /
    • 2022
  • Recently, as Virtual Desktop Infrastructure(VDI) is widely used not only in office work environments but also in workloads that use high-spec multi-core-based applications, the requirements for real-time and stability of VDI are increasing. Accordingly, the display protocol used for remote access in VDI and performance optimization of virtual machines have also become more important. In this paper, we propose two ways to configure desktop virtualization for multi-core-based application operation. First, we propose a codec configuration of a display protocol with optimal performance in a high load situation due to multi-processing. Second, we propose a virtual CPU scheduling optimization method to reduce scheduling delay in case of CPU contention between virtual machines. As a result of the test, it was confirmed that the H.264 codec of Blast Extreme showed the best and stable frame, and the scheduling performance of the virtual CPU was improved through scheduling optimization.

Study on shear fracture behavior of soft filling in concrete specimens: Experimental tests and numerical simulation

  • Lei, Zhou;Vahab, Sarfarazi;Hadi, Haeri;Amir Aslan, Naderi;Mohammad Fatehi, Marji;Fei, Wu
    • Structural Engineering and Mechanics
    • /
    • v.85 no.3
    • /
    • pp.337-351
    • /
    • 2023
  • In this paper, the shear behavior of soft filling in rectangular-hollow concrete specimens was simulated using the 2D particle flow code (PFC2D). The laboratory-measured properties were used to calibrate some PFC2D micro-properties for modeling the behavior of geo-materials. The dimensions of prepared and modeled samples were 100 mm×100 mm. Some disc type narrow bands were removed from the central part of the model and different lengths of bridge areas (i.e., the distance between internal tips of two joints) with lengths of 30 mm, 50 mm, and 70 mm were produced. Then, the middle of the rectangular hollow was filled with cement material. Three filling sizes with dimensions of 5 mm×5 mm, 10 mm×5 mm, and 15 mm×5 mm were provided for different modeled samples. The parallel bond model was used to calibrate and re-produce these modeled specimens. Therefore, totally, 9 different types of samples were designed for the shear tests in PFC2D. The shear load was gradually applied to the model under a constant loading condition of 3 MPa (σc/3). The loading was continued till shear failure occur in the modeled concrete specimens. It has been shown that both tensile and shear cracks may occur in the fillings. The shear cracks mainly initiated from the crack (joint) tips and coalesced with another one. The shear displacements and shear strengths were both increased as the filling dimensions increased (for the case of a bridge area with a particular fixed length).

Experimental Validation of Topology Design Optimization Considering Lamination Direction of Three-dimensional Printing (3D 프린팅 적층 방향을 고려한 위상최적설계의 실험적 검증)

  • Park, Hee-Man;Lee, Gyu-Bin;Kim, Jin-san;Seon, Chae-Rim;Yoon, Minho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.3
    • /
    • pp.191-196
    • /
    • 2022
  • In this study, the anisotropic mechanical property of fused deposition modeling three-dimensional (3D) printing based on lamination direction was verified by a tensile test. Moreover, the property was applied to solid isotropic materials with penalization-based topology optimization. The case of the lower control arm, one of the automotive suspension components, was considered as a benchmark problem. The optimal topological results varied depending on the external load and anisotropic property. Based on these results, two test specimens were fabricated by varying the lamination direction of 3D printing; a tensile test utilizing 3D non-contact strain gauge was also conducted. The measured strain was compared with that obtained by computer-aided engineering response analysis. Quantitatively, the measurement and analysis results are found to have good agreement. The effectiveness of topology optimization considering the lamination direction of 3D printing was confirmed by the experimental result.

Optimization Design for the Use of Mechanical Switch in Z-source DC Circuit Breaker (Z-source 직류 차단기의 기계식 스위치 적용을 위한 최적화 설계)

  • Lee, Hyeon Seung;Lee, Kun-A
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.1
    • /
    • pp.12-19
    • /
    • 2022
  • Circuit breakers are a crucial factor in ensuring the safety of a Direct Current (DC) grid. One type of DC circuit breaker, the Z-source DC circuit breaker (ZCB), uses a thyristor, which is a type of semiconductor switch. In the event of a fault in the circuit, the ZCB isolates the fault by generating a zero crossing current in the thyristor. The thyristor quickly and actively isolates the fault while generating a zero crossing current, but thyristor switch cannot control turn-off and the allowable current is lower than the current of the mechanical switch. Therefore, it is best to use a mechanical switch with a high allowable current capacity that is capable of on/off control. Due to the slow reaction time of mechanical switches, they may not isolate the fault during the zero crossing current time interval created by the existing circuit. In this case, the zero crossing current time can be increased by using the property that hinders the rapid change in the current of the inductor. This paper will explore whether adding system inductance to increase the zero crossing current time interval is a solution to this problem. The simulation of changing inductor and capacitor (LC) of the circuit is repeated to find an optimal change in the zero crossing current time according to the LC change and provides an inductor and capacitor range optimized for a specific load. The inductor and capacitor range are expected to provide optimization information in the form LC values for future applications of ZCB's using a mechanical switch.