• 제목/요약/키워드: Load Transfer

검색결과 1,619건 처리시간 0.025초

전력변환차단기의 트리거 기구 최적화 (Optimization ova Mechanism for Power Transfer Breakers)

  • 조두현;김권희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.735-739
    • /
    • 2002
  • PTB(Power Transfer Breaker) is a device which incorporate the functions of ACB(Air Circuit Breaker) and ATS(Automatic Transfer Switch). ACB is a circuit breaker against overload and ATS is a switching device to transfer the load between two electric power sources. An existing PTB design based upon the 5 bar & cam mechanism has been regarded to be too complex and thus a simpler 4 bar mechanism with trigger lock is proposed. Experimentation and optimization of the trigger lock is presented.

  • PDF

소형박용 디젤엔진의 전열특성 (Characteristics of Heat Transfer for Small-size Marine Diesel Engine)

  • 최준섭
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권4호
    • /
    • pp.36-42
    • /
    • 1996
  • Analysis of heat transfer on small-size Diesel engine is required for the development of high performance and efficiency engine. This basic study aims to establish heat transfer technique for marine Diesel engine. The main results from this study are as follows : 1) Overall engine heat transfer correlation of Re-Nu. 2) Radiant heat flux as fraction of total heat flux over the load range of several different Diesel engine. 3) Characteristics of heating curves on piston, cylinder liner and head. 4) Surface heat flux versus injection timing.

  • PDF

Seismic assessment of transfer plate high rise buildings

  • Su, R.K.L.;Chandler, A.M.;Li, J.H.;Lam, N.T.K.
    • Structural Engineering and Mechanics
    • /
    • 제14권3호
    • /
    • pp.287-306
    • /
    • 2002
  • The assessment of structural performance of transfer structures under potential seismic actions is presented. Various seismic assessment methodologies are used, with particular emphasis on the accurate modelling of the higher mode effects and the potential development of a soft storey effect in the mega-columns below the transfer plate (TP) level. Those methods include response spectrum analysis (RSA), manual calculation, pushover analysis (POA) and equivalent static load analysis (ESA). The capabilities and limitations of each method are highlighted. The paper aims, firstly, to determine the appropriate seismic assessment methodology for transfer structures using these different approaches, all of which can be undertaken with the resources generally available in a design office. Secondly, the paper highlights and discusses factors influencing the response behaviour of transfer structures, and finally provides a general indication of their seismic vulnerability. The representative Hong Kong building considered in this paper utilises a structural system with coupled shear walls and moment resisting portal-frames, above and below the TP, respectively. By adopting the wind load profile stipulated in the Code of Practice on Wind Effects: Hong Kong-1983, all the structural members are sized and detailed according to the British Standards BS8110 and the current local practices. The seismic displacement demand for the structure, when built on either rock or deep soil sites, was determined in a companion paper. The lateral load-displacement characteristic of the building, determined herein from manual calculation, has indicated that the poor ductility (brittle nature) of the mega-columns, due mainly to the high level of axial pre-compression as found from the analysis, cannot be effectively alleviated solely by increasing the quantity of confinement stirrups. The interstorey drift demands at lower and upper zones caused by seismic actions are found to be substantially higher than those arising from wind loads. The mega-columns supporting the TP and the coupling beams at higher zones are identified to be the most vulnerable components under seismic actions.

Magnetic Resonant Wireless Power Transfer with L-Shape Arranged Resonators for Laptop Computer

  • Choi, Jung Han;Kang, Seok Hyon;Jung, Chang Won
    • Journal of electromagnetic engineering and science
    • /
    • 제17권3호
    • /
    • pp.126-132
    • /
    • 2017
  • In this study, we designed, measured, and analyzed a rearranged L-shape magnetic resonance coupling wireless power transfer (MR-WPT) system for practical applications with laptops. The typical four resonator MR-WPT (Tx part: source loop and Tx coil; Rx part: Rx coil and load loop) is difficult to apply to small-sized stationary and mobile applications, such as laptop computers, tablet-PCs, and smartphones, owing to the large volume of the Rx part and the spatial restrictions of the Tx and Rx coils. Therefore, an L-shape structure, which is the orthogonal arrangement of the Tx and Rx parts, is proposed for indoor environment applications, such as at an L-shaped wall or desk. The relatively large Tx part and Rx coil can be installed in the wall and the desk, respectively, while the load loop is embedded in the small stationary or mobile devices. The transfer efficiency (TE) of the proposed system was measured according to the transfer distance (TD) and the misaligned locations of the load loop. In addition, we measured the TE in the active/non-active state and monitor-open/closed state of the laptop computer. The overall highest TE of the L-shape MR-WPT was 61.43% at 45 cm TD, and the TE decreased to 27.9% in the active and monitor-open state of the laptop computer. The conductive ground plane has a much higher impact on the performance when compared to the impact of the active/non-active states. We verified the characteristics and practical benefits of the proposed L-shape MR-WPT compared to the typical MR-WPT for applications to L-shaped corners.

풍화암 지반에 설치된 소구경말뚝의 거동에 관한 연구 (An Experimental Study on the Behavior of Miscopiles installed in Weathered Weak Rock)

  • 박성재;정경환;이세훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.389-396
    • /
    • 1999
  • In this study compressive and tensile load tests have been performed to investigate reinforcing effect and load transfer mechanism of small diameter piles installed in the foundation soil for the marine suspension bridge. Load tests were carried out on steel plate with diameters of 50cm, 100cm and 150cm varying loads starting from 39 tons up to 314 tons. Small diameter piles were proved to behavior like as friction piles and loads were not transmitted to the bottom of piles. From pull-out tests, the uplift capacity of small diameter piles was largely influenced by reinforcing materials compared to frictional resistance between piles and adjacent soils. The bearing capacity of small diameter piles appeared to be higher than the ultimate bearing capacity evaluated using static formulae. The load carrying capacity of small diameter piles was superior to the bored piles with a similar size. Thus, ultimate bearing capacity estimated from static formulae can provide conservative designs and thereby resulting in economic disadvantages. A further study to accumulate data regarding various soil conditions is recommended for an improved estimation of bearing capacity of piles with small diameter.

  • PDF

프리캐스트 콘크리트 교량바닥판 female-female이음부의 전단실험 (shear Tests on female-to-female Type Joint between Precast Concrete Bridge Decks)

  • 김영진;김영진;김종희
    • 콘크리트학회지
    • /
    • 제10권6호
    • /
    • pp.161-168
    • /
    • 1998
  • 본 연구는 수직전단하중에 대한 프리캐스트 바닥판간 이음부거동을 규명하고 수직전단력 전달에 유리한 이음부 구조도출을 위해 female-female 형식의 이음부를 제안하고, 실험 및 유한요소해석을 수행한 것이다. 경사각, 이음부깊이/높이 및 구속응력을 변수로 총 18개의 실험체에 대한 실험 및 유한요소해석결과 ,이음부의균열저항성 개선을 위해서는 경사각이 60。, D/H가 1/4일 경우가 유리하며 측방향구속으로 이음부를 압축상태로 유지하는 것이 이음부 균열방지에 효과적임을 알았다.

비부착 강연선에 대한 포스트텐션 정착구 개발 및 성능 시험 (Development and Performance Test for Unbonded Post-Tensioned Anchor)

  • 조아서;조영욱;전병갑;강현구
    • 콘크리트학회논문집
    • /
    • 제27권1호
    • /
    • pp.11-20
    • /
    • 2015
  • 본 연구에서는 유한요소해석을 통하여 직경 15.2 mm의 비부착식 강연선을 위한 포스트텐션 1구 정착구를 개발하였고 이에 대한 성능시험을 수행하였다. 정착장치에 대한 성능시험으로 콘크리트 표준시방서에 따라 KCI-PS101에 제시된 정하중시험과 하중전달시험 방법이 사용되었다. 정하중시험과 강연선 인장시험을 통하여 개발된 정착구가 강연선 공칭인장강도에도 손상 및 파괴되지 않음을 확인하였다. 하중전달시험을 통해서는 각종 철근보강에 따른 실험체의 압축성능을 확인하였고, 무보강 실험체가 강연선 인장강도의 1.64배까지 저항할 수 있다는 결과를 얻었다.

토목섬유보강 성토지지말뚝시스템에서의 하중전이 효과에 관한 모형실험 (Laboratory Model Tests on the Load Transfer in Geosynthetic-Reinforced and Pile-Supported Embankment System)

  • 홍원표;이재호
    • 한국지반신소재학회논문집
    • /
    • 제9권3호
    • /
    • pp.9-18
    • /
    • 2010
  • 토목섬유보강 성토지지말뚝시스템에서의 하중전이 특성을 규명하기 위하여 일련의 모형실험을 실시하였다. 모형토조에 단독캡 말뚝을 설치하고, 토목섬유를 포설한 후 성토를 실시하였다. 연약지반 대체재료로서 스펀지고무를 사용하였다. 실험결과 성토지지말뚝시스템의 효율은 일정한 말뚝간격비에서는 성토고가 증가할수록 비선형적으로 증가하여 이후 일정한 값에 수렴하는 경향을 나타내었다. 또한 성토고가 일정한 조건에서는 말뚝간격비가 증가할수록 효율의 크기는 감소하였다. 토목섬유를 보강한 경우, 무보강시와 비교하여 말뚝으로 전이되는 하중이 증가하는 것으로 나타났다. 이는 토목섬유의 보강이 연약지반의 거동을 억지하는데 효과가 있음을 나타내는 것이다. 결국 토목섬유보강 성토지지말뚝시스템에서의 하중전이 특성은 말뚝캡 설치간격, 성토고, 지반의 강도정수 및 토목섬유 강성 등에 복합적으로 영향을 받음을 알 수 있다.

  • PDF

2,400 MPa 강연선용 포스트텐션 정착구의 하중전달성능 (The Load Transfer Performance of Post-tension Anchorage with 2,400 MPa Strands)

  • 김선우;노병철;임정훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.63-71
    • /
    • 2018
  • 인장강도가 2,400 MPa인 강연선이 개발되어 콘크리트구조기준 및 KS 규격에 반영되었다. 고강도 프리스트레스트 강연선이 구조물에 적용되기 위해서는 그에 적합한 정착시스템이 함께 사용되어야 한다. 최근에 2,400 MPa 강연선 적용을 위한 포스트텐션 정착구의 개발이 진행되어왔으나, 성능평가에 대한 연구가 미비한 실정이다. 따라서 본 연구에서는 2,400 MPa 강연선을 적용한 포스트텐션 정착구 중 가장 활용도가 높은 9 가닥, 15 가닥, 19 가닥 정착구에 대하여 PTI의 Anchorage Design Zone에 의한 국소구역 구조검토를 실시하였고, ETAG013 및 KCI-PS101에 의한 하중전달성능평가를 수행하였다. 또한 비선형 수치해석을 통해 시험의 적절성을 분석하였다. 그 결과, 2,400 MPa 정착구는 국소구역의 구조성능을 만족하고, 하중전달성능 조건을 만족하는 것으로 나타났다.