• Title/Summary/Keyword: Load Power Factor

Search Result 845, Processing Time 0.032 seconds

A Study on ZVT Boost Converter Using a ZCS Auxiliary Circuit (ZCS 보조회로를 이용한 ZVT Boost 컨버터에 관한 연구)

  • Ryu D.K.;Lee W.S.;Choi T.Y.;Seo M.S.;Won C,Y.;Kim Y.R.
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.129-132
    • /
    • 2001
  • Recently, a ZVT boost converter is embedded in a power factor correction system. The control circuit of the converter assures soft-switching for all the MOSFETs and load regulation. The PFC system contains additional control circuits which assure the input voltage in a sinusoidal form and feed-forward line voltage regulation. In this paper, a soft switching boost converter with zero-voltage transition(ZVT) main switch using zero-current switching(ZCS) auxiliary switch is proposed. Operating intervals of the converter are persented and analyzed. The proposed results show that the main switch maintains UT while auxiliary switch retains ZCS for the complete specified line and load conditions.

  • PDF

The High Performance of a Output Voltage in 3-phase PWM Converter (3상 PWM 콘버어터의 출력전압 속응제어)

  • Yong, Hong-Taek;Cho, Sun-Bong;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.992-994
    • /
    • 1992
  • Diode rectifier has many low order harmonics in line currents. So, power factor of input side is relatively low. Recently, PWM conveters have been actively studied in order to reduce the harmonics. This paper describes a voltage source PWM rectifier with feed-forward compensation of instantaneous load power. By adding feed-forward compensation to dc link voltage control loop, the fluctuation of dc link voltage at a sudden load change can be considerably suppressed. Simulation based on analytical approach Was performed and the results of it showed a good agreement with theory.

  • PDF

A Method of Determining B-coefficient Applying VDLM/LRDA (전압의존형 부하모델과 손실재분배 알고리즘을 적용한 B계수 산정법)

  • Chae, Myung-Suk;Lee, Myung-Hwan;Kim, Byung-Seop;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1183-1185
    • /
    • 1999
  • The basic purpose of economic dispatch problem is that minimize fuel cost with inequality constraint of generator output. To solve this problem it is very important to express power loss equation that have quadratic function of generator output power included B-coefficient. This Paper presents a method in determining B-coefficient by use A-matrix that is calculated by loss re-distribution algorithm (LRDA) considering voltage dependent load model (VDLM)s. The Proposed algorithm is tested with IEEE 6 bus sample system, which shows the result in each cases by the change of load component factor.

  • PDF

Analysis of the Unbalance of DC Link Voltage in 12-step Inverter with 2-Phase Chopper Preregulator (2상 쵸퍼 Preregulator를 갖는 12-step 인버터에서의 DC Link단 전압 불평형 해석)

  • Nho, Eui-Cheol;Kim, In-Dong
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.258-260
    • /
    • 1995
  • This paper deals with the voltage unbalance of DC link voltage in series connected two 6-step inverters with double chopper preregulator. Each output of the 6-step inverter is connected to each transformer. The secondary windings of one of the transformers is zig-zag connected and the other star connected. The secondary terminals of the two transformers are series connected which makes 12-step output voltage waveform. In this case, the characteristics of the two transformers are rather different each other. The difference results in the voltage unbalance of the two 6-step inverter input capacitor voltages which make the DC link voltage. The degree of the voltage unbalance is analysied with the variations of load power, load power factor and % impedance of the transformer.

  • PDF

Simulation of Phase Unbalance and Power Factor Correction System (비상용발전기의 상불평형 및 역율보상기 시뮬레이션)

  • Shin, B.C.;Song, E.H.;Jeong, C.Y.;Kan, Y.;Cho, J.G.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.419-421
    • /
    • 1997
  • Three-phase system has many problems because of the unbalance load. So we propose two control algorithms using active power filter to dissolve these problems. One is three-leg inverter topology in which ac neutral line is connected directly to the midpoint of two series dc capacitors. The other is four-leg inverter topology in which ac neutral line is provided through a fourth leg. The three-phase unbalance is considered by connecting the load to one-phase. It is show that the proposed control algorithms give good performances.

  • PDF

THE EFFECTIVE VOLTAGE CONTROL SCHEME OF THE INVERTER FOR A STATIC POWER SUPPLY

  • Kim, Byoungjin;Song, Youngsin;Ji, Myoungku;Lee, Jongha;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.336-340
    • /
    • 1998
  • In this paper, an effective control scheme of a single phase UPS inverter is proposed to have no steady state error of the output voltage and the fast response for the load request. The cosine wave tranfer function is proposed to control the output voltage. This controller clearly removes errors of magnitude and phase both in the steady state. On the other hand, a current controller is proposed to reduce the transient time of the voltage control and to improve the bad distorted factor of the output voltage waveform by the load fluctuation and the presences of nonlinear parameters in the plant. The current controller is designed parallel to the voltage controller and performs separately from it.

  • PDF

A Design of Fuzzy Precompensated PID Controller for Load Frequency Control of Power System using Genetic Algorithm (유전 알고리즘을 이용한 전력계통의 부하주파수 제어를 위한 퍼지 전 보상 PID 제어기 설계)

  • Chung, Mun-Kyu;Wang, Yong-Peel;Lee, Jeong-Phil;Chung, Hyeng-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.153-156
    • /
    • 1999
  • In this paper, we design a GA-fuzzy precompensated PID controller for the load frequency control of two-area interconnected power system. Here, a fuzzy precompensated PID controller is designed as a fuzzy logic-based precompensation approach for PID controller. This scheme is easily implemented simply by adding a fuzzy precompensator to an existing PID controller. And we optimize the fuzzy precompensator with a genetic algorithm for complements the demerit such as the difficulty of the component selection of fuzzy controller, namely, scaling factor membership function and control rules.

  • PDF

A Study on Preventing Transient Phenomena Due to Capacitor Switching in Distribution System involving Distributed Generation System (분산전원이 도입된 배전계통에서 커패시터 스위칭에 의한 과도현상 방지에 대한 연구)

  • Lee, D.G.;Hwang, J.S.;Ju, Y.H.;Kim, J.E.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.10-12
    • /
    • 2001
  • This paper presents a study of transient overvoltages caused by capacitor switching on the utility distribution system. Capacitor banks used for power factor correction and voltage regulation can improve efficiency of the power system. But transient voltages due to capacitor switching on the utility system affect the sensitive customer load equipments. If Distributed Generation System (DGS) is involved in the system, the problems become more serious. In this paper, effect of transient voltages at the customer load created by utility capacitor switching is analyzed by simulations Solutions to this problem are presented.

  • PDF

THREE LEVEL SINGLE-PHASE SINGLE STAGE AC/DC RESONANT CONVERTER WITH A WIDE OUTPUT OPERATING VOLTAGE RANGE (넓은 출력 전압제어범위를 갖는 3레벨 단상 단일전력단 AC/DC 컨버터)

  • Marius, Takongmo;Lee, G.W;Kim, M.J;Kim, E.S
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.434-435
    • /
    • 2018
  • In this paper, a single-phase single-stage three-level AC/DC converter with a wide controllable output voltage is presented. It integrates a PFC converter and a three level DC/DC converter into one. The proposed converter operates at a fixed frequency and provides a wide controllable output voltage ($200V_{dc}-430V_{dc}$) with high efficiencies over a wide load range. In addition, the input boost inductors operate in a discontinuous mode to improve the input power factor. Moreover, all the switching devices operate with ZVS, and the converter's THD is small especially at full load. The feasibility of the proposed converter is verified with experimental results of a 1.5kW prototype.

  • PDF

Receving-end's power factor improvement and harmonic current filtering useing the private-substion STATCOM (자가변전설비용 STATCOM의 수전단 역률개선과 고조파 전류 필터링)

  • Oh, Young-Woong;Lee, Eun-Woong;Lim, Su-Saeng;Kim, Seok-Gon;Lee, Seung-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.79-81
    • /
    • 1998
  • STATCOM can compensate industrial load's reactive power and filter the harmonic of nonlinear load's with the rapid dynamic response. In this paper, STATCOM is modelled to synchronous rotating coordinate by circuit dq transformation, and space vector PWM method is applied for broad voltage modulation. Also predict current controller is used for harmonic current filtering.

  • PDF