• 제목/요약/키워드: Live-line

검색결과 246건 처리시간 0.027초

전력선 통신 기반 HD급 미디어 전송 시스템 설계 및 성능 분석 (System Design of High-Definition Media Transceiver based on Power Line Communication and Its Performance Analysis)

  • 김지형;김관웅;김용갑
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.192-196
    • /
    • 2010
  • Due to a development of a modem technology as Power Line Communication(PLC) over 200 Mbps, the high-speed multi-media data trasmission could be currently possible. The strength of the PLC has no more additional wiring work. PLC has also possible to high quality data transmission with currently electrical cable. It has a various strong point campare with existing wire and wireless communication technologies. In This paper we develop a high quality media transmitter-receiver based on merging the HomePlug AV, which is 200 Mbps class PLC technology and HDMI Interface technology. The video function was used for the VEDEO TEST GENERATOR in order to a property valuation. Smart Live 6 software were used for the assessment of audio property. As the result of measurement of the HD class images by capturing from the receiver of the PLC, the quality of images couldn't be confirm any deterioration, which has compared with original reflections. In case of audio part as the result of confirmation of the Phase, Magnitude, it has been confirmed that over 90% of nomal transmition and receiving of acoustic signal. It can be possible to have HD class Media service through the PLC.

Voltage Measurement Accuracy Assessment System for Distribution Equipment of Smart Distribution Network

  • Cho, Jintae;Kwon, Seong-chul;Kim, Jae-Han;Won, Jong-Nam;Cho, Seong-Soo;Kim, Juyong
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1328-1334
    • /
    • 2015
  • A new system for evaluating the voltage management errors of distribution equipment is presented in this paper. The main concept of the new system is to use real distribution live-line voltage to evaluate and correct the voltage measurement data from distribution equipment. This new approach is suitable for a new Distribution Management System (DMS) which has been developed for a distribution power system due to the connection of distributed generation growth. The data from distribution equipment that is installed at distribution lines must be accurate for the performance of the DMS. The proposed system is expected to provide a solution for voltage measurement accuracy assessment for the reliable and efficient operation of the DMS. An experimental study on actual distribution equipment verifies that this voltage measurement accuracy assessment system can assess and calibrate the voltage measurement data from distribution equipment installed at the distribution line.

반조절성 교합기의 심미적 기준 평면에 관한 연구 (DETERMINATION OF ESTHETIC REFERENCE PLANE FOR SEMI-ADJUSTABLE ARTICULATORS)

  • 황희성;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.448-456
    • /
    • 1996
  • The purpose of this study is to evaluate suitable anterior reference point similar to esthetic reference plane of the patient while transferring the suitable facebow. So those who live in Pusan with the normal occlusal relationship were chosen as subjects. The esthetic reference planes determined by the participants themselves and the superior reference line (anterior reference point) in Hanau & Denar articulator were compared with F-H plane in the standard lateral cephalogram. The results were as follows. 1. The angle between the esthetic reference plane and F-H plane was $2.81{\pm}5.7^{\circ}$. 2. The reference line, 43mm from Beyron point to the edge of the upper incisor, was the reference plane that had the closest paralleled relationship with the esthetic reference plane. 3. Transferring with ear piece type face-bow, the anterior reference point that showed the esthetic reference plane was 17mm below orbitale or 43mm above, the edge of the upper incisor.

  • PDF

세포 염색 방법을 이용한 결핵균 감수성 검사법 (Trial for Drug Susceptibility Testing of Mycobacterium tuberculosis with Live and Dead Cell Differentiation)

  • 류성원;김현호;방문남;박영길;박순희;심영수;강성만;배길한
    • Tuberculosis and Respiratory Diseases
    • /
    • 제56권3호
    • /
    • pp.261-268
    • /
    • 2004
  • 연구배경 : 결핵치료에서 어려움을 주는 가장 중요한 요인의 하나가 약제 내성균에 감염된 경우이다. 근래 다제내성 결핵균의 증가는 신속한 결핵균 감수성검사방법 개발에 대한 필요성을 더욱 증가시키고 있다. 활발하게 개발이 진행되고 있는 분자생물학적 기법들도 신속한 내성여부의 구분에 많은 도움을 주고 있지만, 아직까지는 검사약제가 제한되어 있고 보완할 점들이 많이 남아있다. 따라서 저자들은 결핵균 세포 염색 방법에 의해 생균과 사균을 구분할 수 있는 신속하고도 정확한 결핵균 약제 감수성 검사 방법을 검토하여 보았다. 방 법 : 본 연구의 대상으로 대표적인 4가지 항결핵 약제(Isoniazid, Rifampicin, Streptomycin, Ethambutol)에 모두 내성인 임상분리 결핵균 20 균주와 모든 약제에 감수성인 임상분리 결핵균 20 균주를 사용하였다. 약제감수성검사시의 최소 희석배수였던 MacFarland #1 탁도로부터 10배 희석한 결핵균액을 7H9 배양액 $30m{\ell}$에 접종한 후 $37^{\circ}C$에서 24시간 배양한 다음, 핵산 염색액인 Syto 9 (MolecularProbes, USA)과 세포질 염색액인 프로피디움(propidium iodide, $C_{27}H_{34}I_2N_4$)을 결핵균과 잘 섞은 후 실온의 암소에서 15 분간 방치한 후 슬라이드에 $5{\mu}{\ell}$씩 점적하여 형광 현미경으로 관찰하였다. 결 과 : 실험에 사용한 약제내성 결핵균은 4가지의 항결핵약제의 각 농도가 함유된 7H9 배양액에서 사멸하지 않고 생존하고 있음을 형광 현미경상에서 확인 할 수 있었다. 프로피디움(propidium iodide)은 살아있는 세균의 경우 세포핵은 염색시키지 못하고 세포질만 염색함으로써 살아있는 결핵균은 형광현미경 시야에서 녹색을 띄게 되고, 세포의 핵산을 염색시키는 Syto 9 은 사멸한 세포의 세포질을 통과하여 결핵 약제에 감수성인 결핵균의 세포핵을 염색시켜 형광 현미경 시야에서 붉은 색으로 관찰 되었다. 결 론 : Acridin (Syto9)과 propidium 성분을 이용하여 세포를 형광 염색시켜 세포의 사멸 및 생육을 판단하는 방법을 결핵균 약제감수성검사에 적용한 결과, 간편하고도 신속하게 24시간 이내에 내성균과 감수성균을 구분할 수 있었다. 생균과 사균 세포의 판별법으로 기존의 결핵균 감수성 방법을 대체하기 위해서는 형광현미경을 비롯한 실험실 장비와 숙련된 검사자가 필요하지만, 배양된 균으로 검사하는 데만 4주 이상 소요되는 기존의 결핵균 감수성 검사 방법을 대체할 수 있는 매우 저렴하고도 간편한 검사방법으로 판단되었다.

Calcium수송기전에 미치는 Carbachol의 영향 (Calcium Movement in Carbachol-stimulated Cell-line)

  • 이종화
    • 대한약리학회지
    • /
    • 제31권3호
    • /
    • pp.355-363
    • /
    • 1995
  • Calcium수송에 대한 기전을 추구하기위하여, carbachol을 사용하여 ml muscarinic receptor-transfected RBL-2H3 cell-line에서 다음과 같은 실험결과를 얻었기에 이에 보고한다. 1) Carbachol의 투여로 이들 cell-line에서 $Ca^{2+}$ influx가 농도에 따라 증가하였고, hexosaminidase 분비양도 의의있게 증가하였다. 2) Atropine 투여로 Carbachol의 상승작용이 의의있게 억제되었다. 3) 수종의 금속양이온을 투여하여 carbachol의 $Ca^{2+}$수송에 대한 영향을 관찰한 바, 이들 금속이온들은 $Ca^{2+}$의 influx를 의의있게 억제하였다. 4) PMA(20 nM) 투여로 carbachol의 hexosaminidase의 분비는 억제되지 못했지만 $Ca^{2+}$ influx는 억제되었다. 5) PTx $(0.2\;{\mu}g/ml)$ 투여로 carbachol의 hexosaminidase 분비가 의의있게 억제되었다. 위의 결과로 미루어 보아, 이 세포의 muscarinic receptor가 calcium channel을 통한 calcium수송에 매우 중요한 영향을 나타내는데, 이들 calcium ion channel은 적어도 두 종류가 존재하며, 하나는G-protein-dependent calcium channel에 의하며, 다른 하나는 G-protein-independent calcium channel에 대한 작용에 의한 것으로 생각된다. 또한 이 calcium channel들은 2가 또는 3가의 다른 금속 ion들에 의하여 calcium수송이 억제된다.

  • PDF

22.9kV 다중 접지 지중 전력 케이블의 가압 상태 진단에 관한 기초 연구 (A Study on Diagnosis of The Energized Status of 22.9kV Multigrounded Underground Power Cable)

  • 김창교;홍진수;정영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권10호
    • /
    • pp.699-703
    • /
    • 1999
  • An experimental study to identify the energized status of the 22.9kV underground power cable by the detection of vibration has been performed. We have derived that there exists vibration at double the line frequency in live cables by electromagnetic force. The relative amplitudes of the cable vibration according to the energized status of the cable were calculated by computer simulation. The cable vibration can also be picked up by accelerometer. A prototype was tested on the underground distribution system in Chonan substation, KEPCO. Comparison between simulation results and field test results was performed. The results showed that the energized status of the calble can be identified by measuring the vibration of the cable using accelerometer.

  • PDF

도로교 콘크리트 바닥판의 합리적인 수명 평가 및 예측시스템 개발 (Development of Probabilistic Prediction System for Remaining Life of Reinforced Concrete Bridge Decks)

  • 오병환;최영철;이준혁
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.637-640
    • /
    • 2002
  • The deterioration of RC deck slabs has been a serious problem and high portion of budget has been a spent for repair and strengthening of deck slab. The concrete deck slabs are subject to direct application of vehicle loading and accumulation of fatigue damage. Besides, various environmental causes. In this paper, an probabilistic study is carried out to predict exact load effects and structural capacity of deck slab during its service life, and estimate an appropriate remaining life of deck slab. To achieve this purpose the live load model is developed using by influence line including deterioration of deck slab, and deterioration model of bridge deck slab is developed. In addition, the fatigue life of reinforced concrete deck slabs considering corrosion of reinforcement are estimated based on experimental formula. This study will help rational decisions for the management and repair of reinforced concrete deck slabs.

  • PDF

전력선통신 기반 A/V 신호 송수신기 설계 및 특성분석

  • 김지형;김용갑
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.285-285
    • /
    • 2009
  • Due to a development of a modem technology as Power Line Communication(PLC) over 200 Mbps, the high-speed multi-media data trasmission could be currently possible. In This paper we develop a high quality media transmitter-receiver based on merging the HomePlug AV, which is 200 Mbps class PLC technology and HDMI Interface technology. Smart Live 6 software were used for the assessment of audio property. As the result of measurement of the HD class images by capturing from the receiver of the PLC, the quality of images couldn't be confirm any deterioration, which has compared with original reflections. In case of audio part as the result of confirmation of the Phase, Magnitude, it has been confirmed that over 90% of nomal transmition and receiving of acoustic signal.

  • PDF

Interactive Technology Education at Pusan National University

  • Park, Sang-Joo;Yoon, Joong-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1195-1200
    • /
    • 2004
  • We introduce an introductory engineering education course for engineering majors and non-engineering majors. This course does not require any previous knowledge and experience on engineering. It requires strong curiosities and imaginations on current and future society we live in, where technology is inseparable ingredient. Course encourages attendees to explore fundamental issues of engineering: what is proper technology and what are proper ways of exercising engineering, issues dealt in soft engineering. Since course topics cover many aspects of technology, traditional learning methods fail to be successful and efficient. Various efficient learning methods have been proposed and implemented. We utilize various interactive tangible media, which include simulated thought experiments and physical media experiences. About 20 episodes in short film format are produced based on scenario written according to related issues selected. Physical media like interactive robots are introduced for attendees' stimulated experiences. We summarize our exciting experiments on interactive teaching experiences at Pusan National University which include on/off-line interactions, assignments, projects, and evaluations.

  • PDF

실내디자인 요소와 낙상에 대한 노인들의 인지에 관한 연구 (The Perception of Interior Design Factors Related to Risk of Falls among Elderly)

  • 박희진
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2000년도 학술발표대회논문집
    • /
    • pp.131-136
    • /
    • 2000
  • The purpose of this study is to identify the perceptual differences among independent elderly relative. to falls risk associated with specified environmental design factors. The sample consisted of 135 independent elderly who live in Ulsan. The data were collected by utilizing questionnaire which included demographic information, and environmental design assessments accompanied by line drawings. The data were analyzed by using SAS program. The major findings were as follows: (1) There were 35(25.9%) elderly experienced fall(s) within one year and about half of the fallers fell more than once. (2) The elderly perceived lighting is the most hazardous interior design factor related to increased risk of falls. (3) There was a significant difference among age groups on perception of lighting as interior design factors and the elderly perceived differently floor as interior design factors by their perceived health status.