• 제목/요약/키워드: Lithium disilicate ceramic

검색결과 71건 처리시간 0.026초

심미보철 치료의 경향과 이해 : part 1. IPS e.max (Understanding and trends of esthetic treatment in prosthodontics : IPS e.max)

  • 강정인;허유리;이명선;손미경
    • 한국치위생학회지
    • /
    • 제14권4호
    • /
    • pp.447-452
    • /
    • 2014
  • With the increase of esthetic demands, most patients want to have restorations which are not only functional but also esthetic. For the esthetic restoration, many ceramic systems have been introduced and applied in dentistry. Among those ceramic restorations, IPS e.max system composed of lithium disilicate glass ceramic is one of the most commonly used systems because it has strength and esthetic characteristics. IPS e.max system is divided into IPS e.max Press and IPS e.max CAD according to the manufacturing methods. IPS e.max Press is fabricated through heat-pressed technique with ceramic ingot, which is very simple. The restorations which are made using IPS e.max system can apply to 3 units restoration for the anterior teeth and premolar, and single posterior tooth restoration. Cementation is one of the most important clinic procedure for the longevity of the restorations. All ceramics are bonded by resin cements, it is classified into three groups including adhesive, self-adhesive, and conventional. Variolink N, which is an adhesive resin cement and manufactured by same company with IPS e.max, is recommended for the bonding of IPS e.max restoration. Conventional and self-adhesive resin cement is also available. The aim of this review article is to provide the understanding of material properties, production procedure and clinical application of IPS e.max system.

Color changes of ceramic veneers following glazing with respect to their composition

  • Kim, Sung-Joon;Woo, Jae-Man;Jo, Chan Woo;Park, Ju-Hee;Kim, Soo Kyung;Kahm, Se Hoon
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.16-22
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare the translucency and color changes of ceramic laminate veneers of different composition following glazing process. MATERIALS AND METHODS. $10mm{\times}10mm$ square specimens of 0.6 mm and 1.0 mm thicknesses were fabricated with IPS e.max Press (EM) and IPS e.max ZirPress (ZP) (n=10 per group). The color coordinates (CIE $L^*$ $a^*$ $b^*$) of the specimens were recorded with a colorimeter before and after glazing. The color changes and translucency parameter (TP) were calculated. For the comparisons with the composition and thicknesses between the 'not glazed' and 'glazed' groups, statistical analyses were done through paired T-test, independent two-sample T-test, and multiple regression analysis using SPSS 18.0 (P<.05). RESULTS. The TP of 0.6 mm EM was higher than that of 0.6 mm ZP. Total color difference (${\Delta}E^*$) between bare and glazed specimens of 1.0 mm EM was greater than that of 1.0 mm ZP with statistical significance. Following glazing, specimens from all groups showed statistically significant amount of decrease in $L^*$ and $a^*$, and statistically significant increase in $b^*$. The result of multiple regression analysis of EM and ZP showed that ${\Delta}L^*$ improved ${\Delta}E^*$. CONCLUSION. Within the limitations of present study, we conclude that translucency and color of ceramic laminate veneers change significantly after glazing process, and the nature and amount of changes vary with different compositions.

도재층의 두께와 색이 도재수복물의 최종 색조에 미치는 영향 (THE INFLUENCE OF PORCELAIN LAYER THICKNESS AND COLOR ON THE FINAL SHADE OF CERAMIC RESTORATIONS)

  • 성동환;이임기;송진원;복원미;안승근;박찬운
    • 대한치과보철학회지
    • /
    • 제43권5호
    • /
    • pp.587-598
    • /
    • 2005
  • Statement of problem: Ceramic restorations should be made of porcelain layers of different opacity, shade, and thickness in order to provide a natural appearance. Lithium disilicate glass-ceramic system has superior color reproducibility, because it uses the ceramic ingot which is similar to teeth shade and uses the staining technique and layering technique. However, staining technique has a fault of discoloration. Also, porcelain is divided core and dentin layer, it is not enough to study about the influence of porcelain layer thickness and shade on the shade of ceramic restorations. Purpose: The purpose of this study was to evaluate the influence of porcelain layer thickness and color on the final shade of ceramic restorations. Materials and method: The CIE $L^*a^*b^*$(CIELAB) values of 72 assembled specimens, each consisting of 3 discs (enamel porcelain 0.2 mm/dentin porcelain -1.2, 0.9, 0.7, 0.5 or 0.3 mm/ceramic core -0.3, 0.5, 0.7, 0.9 or 1.2 mm, diameter is 1.0 mm) were evaluated with a spectrophotometer (Model Chromaview 300, Spectron Tech Co, Korea) for the shade A1, A2, A3 and A4. Distilled water (refractive index: 1.7) was used to attain optical contact between the layers. White, white gray, and white brown backgrounds were used to assess the influence of the background on the final shade. And the mean color difference value$({\Delta}E)$ was calculated. Results and conclusion: The results obtained from this study were as follows. 1. There was a significant correlation between the thickness ratio of the ceramic core/dentin porcelain system and $L^*,\;a^*\;and\;b^*$ values when the total thickness of specimen combination was smaller than 1.4 mm(P<0.05). 2. The specimen which the ceramic core thickness was more than 0.7 mm had the best masking effect against background colors. 3. The mean color difference value$({\Delta}E)$ is smaller than 2 $({\Delta}E<2)$ when the ceramic core thickness was larger than 0.7 mm and the total thickness of specimen was more than 1.4 mm.

심미수복을 위한 글라스-세라믹 재료의 치과 응용 (Dental application of glass-ceramic materials for aesthetic restoration)

  • 배태성
    • 대한치과의사협회지
    • /
    • 제58권7호
    • /
    • pp.435-442
    • /
    • 2020
  • 치과의사가 수복재료를 선택하고 환자에게 추천할 때는 수복할 치아 위치, 결손 정도, 환자의 심미적 요구도, 저작력, 나이, 경제적 여건 등 여러 가지의 요인을 고려한다. 그렇지만, 수복재료를 선택할 때의 일차적인 기준은 구강 내에서 기능 시 작용하는 교합력을 최우선으로 고려해야 한다. 미국 국립보건원(NIH) 지원으로 조사된 연구 결과에 의하면, 전치부 수복재료로서는 리튬 디실리케이트계 글라스-세라믹이 54%, layered zirconia가 17%, 루사이트 강화 글라스-세라믹이 13% 순을 보여, 전치부 수복재료로서 리튬 디실리케이트계 글라스-세라믹이 가장 많이 사용었다. 또한 구치부 수복재료로서는 단일구조 지르코니아가 32%, 금속-세라믹이 31%, 리튬 디실리케이트계 글라스-세라믹이 21% 순을 나타냈다. 세라믹 수복 재료의 특성을 살펴보면, 단일구조 지르코니아는 강도는 높지만 명도가 높고 저온열화로 인한 강도 저하가 일어날 수 있다. layered zirconia는 심미성은 우수하지만 강도가 낮은 비니어 세라믹의 칩핑과 박리가 문제가 되고 있다. 리튬 디실리케이트계 글라스-세라믹은 심미성은 우수하지만 지르코니아에 비해 강도가 낮으므로 구치부에 적용 시 파절이 일어날 위험성이 있다. 루사이트계 글라스-세라믹은 심미성은 우수하지만 기본적으로 강도가 낮기 때문에 전치부에 한정하여 적용한다. 세라믹 크라운이 구치부 교합력에 저항하기 위해서는 350 MPa 이상의 굴곡강도를 가져야 한다. 리튬 디실리케이트계 글라스-세라믹은 광투과성이 양호한 심미성이 있는 재료이므로 비니어 없이 전치부에 적용할 수 있고, 굴곡강도가 400 MPa 이상이므로 구치부 교합력에 저항할 수 있고, HF에 의한 산부식과 실란(silane) 처리가 가능하므로 레진과 강한 결합력을 얻을 수 있고, 또한 포세린에 비해 대합치의 마모가 적다. 이러한 점들을 고려하면 리튬 디실리케이트계 글라스-세라믹 재료는 전구치부의 단일치 수복에 적합한 성질을 갖고 있음을 알수 있다. 그렇지만 그의 임상 응용이 더욱 증가하기 위해서는 이들 재료에 대한 보다 많은 연구와 이해가 필요하리라고 생각된다.

  • PDF

Empress 2 도재의 두께에 따른 파절강도에 관한 연구 (INFLUENCE OF THICKNESS OF EMPRESS 2 CERAMIC ON FRACTURE STRENGTH)

  • 고정우;양재호;이선형
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.446-460
    • /
    • 2000
  • All-ceramic restorations have had a more limited life expectancy than metal ceramic crowns be-cause of their lower strength. The relatively lower strength has limited the use of all-ceramic crowns to the areas where occlusal loads are lower Therefore many researches have been done to increase the strength of all-ceramic crowns. IPS Empress 2 is a new type of lithium disilicate glass-ceramic with enhanced physical characteristics which has been in use clinically since 1998. Previous researches reported that the flexural strength of all-ceramic material was greater than 300 MPa, and all-ceramic crowns can be used in staining or layering technique. The objective of this study was to investigate the influence of the thickness of IPS Empress 2 ceramic on fracture strength. Both staining technique and layering technique was investigated. Vita VMK was used as control. For all three groups, five specimens each of 0.8mm, 1.0mm, 1.4mm, 1.8mm, and 2.2mm thick-ness (a total of 75 specimens) were prepared. Control group : Vita VMK Porcelain specimens were prepared with dentine ceramic and liquid glazing was done. Group I : IPS Empress 2 were prepared with staining technique and stained twice and glazed once. Group II : IPS Empress 2 were prepared with layering technique and glazed after wash firing. The thickness and diameter of the specimen were measured and controlled after specimen preparation. Biaxial Flexure Test (ASTM Standard F394-78) was adopted as this test method produces results least affected by the edge condition of the specimens. Fracture strength was measured with Instron Universal Testing Machine. Conclusions are as follow : 1. The fracture strength was increase in order of control group, test group I, test group II. 2. Fracture strength of the group I (Empress 2 Staining) was 65.54 N in 0.8mm, 155.2 N in 1.0mm, 233.5 N in 1.4mm, 434.5 N in 1.8mm, and 600.1 N in 2.2mm. 3. Fracture strength of the group II (Empress 2 Layering) was 190.0 N in 0.8mm, 283.5 N in 1.0mm. 437.2 N in 1.4mm, 732.0 N in 1.8mm, and 1115.0 N in 2.2mm. 4. No statistical difference was found in flexural strengths according to thickness in a specified group(p>0.05).

  • PDF

적층가공방식을 이용한 열가압 세라믹 라미네이트 비니어의 적합도: 3차원 분석 (Fitness of heat - pressed ceramic laminate veneer using additive manufacturing process: 3 Dimensional analysis)

  • 강신영;이하나;김어빈;이경은;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제39권3호
    • /
    • pp.137-143
    • /
    • 2017
  • Purpose: The purpose of this study is to analyze the fitness of heat - pressed ceramic laminate veneers fabricated using the additive manufacturing. Methods: Impression was replicated by using light body silicone and heavy body silicone on the custom tray, and it was fabricated using Type IV Stone. The test specimens were prepared by using a dental scanner, a laminating veneer using a dental design program, and a specimen with a 3D printer. The control specimens were prepared by the lost wax technique and heat - pressed to fabricate the specimens. The data of the specimens were measured by the RMS value of the internal fitness a using a 3-dimensional measurement program. Results: The Stereolithography laminate veneer group was measured at $78.10(4.09){\mu}m$ and the LWV group was measured at $31.50(5.10){\mu}m$. There is a significant difference between the two groups (p<0.001) Conclusion : Evaluation of fitness laminate veneers was fabricated by additive manufacturing showed the difference statistically significantly and clinically acceptable result.

Influence of polishing systems on roughness and color change of two dental ceramics

  • Maciel, Lucas Campagnaro;Silva, Carlos Frederico Bettcher;de Jesus, Ricardo Huver;da Silva Concilio, Lais Regiane;Kano, Stefania Carvalho;Xible, Anuar Antonio
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권4호
    • /
    • pp.215-222
    • /
    • 2019
  • PURPOSE. To evaluate the polishing effect on roughness and color change of pressed and layering ceramics after immersion in coffee solution. MATERIALS AND METHODS. 88 ceramic discs ($1.0mm{\times}10.0mm$) were manufactured - 44 nano-fluorapatite layering ceramics (IPS e.max Ceram. Group C) and 44 pressed lithium disilicate ceramic discs (IPS e. max Press - Group P). Each group was divided into 4 subgroups according to surface treatments: (G) Glaze, (S) Shofu polishing system (Shofu Inc.), (E) Edenta AG polishing System, (KG) $30-{\mu}m$ diamond granulation tip. Surface roughness (Ra) and color change (${\Delta}E$) measurings after the surface treatments were performed, before and 12 days after the immersion in coffee solution. A samples' qualitative analysis was conducted with a scanning electron microscopy (SEM). Data were statistically-treated with one-way-ANOVA and Duncan's tests, apart from paired t-test and Pearson's correlation test (${\alpha}=5%$). RESULTS. The decrescent order, both for surface roughness (Ra) and ${\Delta}E$ for both ceramics were: KG > E > S > G (P<.05). With exception for PG and CG subgroups, which did not present statistical difference between them, all other pressed ceramics subgroups presented smaller Ra values and greater ${\Delta}E$ values than the layering ceramics subgroups (P<.05). CONCLUSION. Although mechanical polishing systems presented intermediate Ra values, their colors were considered clinically acceptable. There is a strong correlation between the surface roughness and the color change of tested ceramics.

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF EMPRESS 2 CERAMIC AND TARGIS-VECTRIS CROWN

  • Cha Young-Joo;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.599-610
    • /
    • 2001
  • Due to an increasing interest in esthetics and concerns about toxic and allergic reactions to certain alloys, patients and dentists have been looking for metal-free tooth-colored restorations. Recent improvement in technology of new all-ceramic materials and composite materials has broadened the options for esthetic single crown restorations. The aim of this investigation was to study the fracture strength of the metal-free posterior single crowns fabricated using two recently introduced systems, Empress 2 ceramic and Targis-Vectris. Forty premolar-shaped stainless steel dies with the 1mm-wide circumferential shoulder were prepared. Ten cylindrical crowns having a diameter of 8.0mm and total height of 7.5mm were fabricated for each crown system respectively(PFM, Empress staining technique, Empress 2 layering technique, and Targis- Vectris). The crowns were filled with cement and placed on the stainless steel dies with firm finger pressure. The crowns were then stored in distilled water at room temperature for 24 hours before testing. The crowns were tested for fracture strength in an Instron universal testing machine (Instron 6022). With a crosshead speed of 1mm/min the center of the occlusal surface of the crown was loaded using a 4-mm-diameter stainless steel ball until fracture occurred. The fracture surfaces of the crowns were gold coated and examined using scanning electron microscopy(Jeol JSM-840 Joel Ltd., Akishima, Tokyo, Japan). Within the parameters of this study the following conclusions were drawn: 1. The mean fracture strength for PFM crowns was 5829(${\pm}906$)N; for Empress staining technique the fracture strength was 1697(${\pm}604$)N; for Empress 2 Layering technique the fracture strength was 1781N(${\pm}400$)N, and the fracture strength for Targis- Vectris was 3093(${\pm}475$)N. 2. The fracture strength of the PFM crowns was significantly higher than that of the Empress 2 and the Targis-Vectris crowns (P<0.05). 3. The fracture strength of the Targis-Vectris crowns was significantly higher than that of the Empress 2 crowns (P<0.05). 4. No statistical difference was found when Empress staining technique was compared with Empress 2 layering technique. 5. The SEM image of fracture surface of Empress 2 crown showed a very dense microstructure of the lithium disilicate crystals and the SEM image of fracture surface of Targis-Vectris crown showed indentations of Vectris and some fibers tom off from Vectris.

  • PDF

금속선 강화에 따른 열 가압 도재의 파절저항 (The fracture resistance of heat pressed ceramics with wire reinforcement)

  • 조득원;동진근;오상천;김유리
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.191-198
    • /
    • 2009
  • 연구목적: 본 연구는 높은 심미성을 나타내지만 낮은 파절 강도로 인하여 구치부에서의 사용이 제한되고 있는 전부도재 고정성 국소의치의 파절강도를 증가시키기 위한 방법으로, 취성 재료인 도재에 인장강도가 높은 금속선을 삽입하고 물리적, 기계적 성질을 알아보고자 하였다. 연구 재료 및 방법: lithium disilicate(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Lichtenstein)와 0.41 mm 직경의 Ni-Cr 금속선(Alfa Aesar, Johnson Matthey Company, USA)을 사용하여, 금속선의 수와 배열을 달리한 4개의 실험군 시편을 제작하였다. 모든 시편은 폭 4 mm, 두께 2 mm, 길이 15 mm의 직육면체로 제작하였다. 실험군 1, 2, 3은 각각 한 가닥, 두 가닥, 세 가닥의 금속선을 도재 시편의 장축을 따라 배열하였으며, 실험군 4는 세 가닥의 금속선을 도재 시편의 장축에, 다섯 가닥의 금속선을 도재 시편의 횡축에 배열하였다. 대조군에는 금속선을 삽입하지 않았으며, 대조군 및 각각의 실험군의 시편은 각 군당 12개로 하였다. 결과: 만능 시험기(Z020, Zwick, Germany)를 이용하여 파절시점까지 하중을 가한 후, 굴곡계수, 굴곡강도, 파절시점까지의 변형률, 파괴인성을 측정하였다. 파절된 시편의 도재와 금속선의 계면을 횡절단 및 연마하여 주사전자현미경(JSM-6360, JEOL, Japan)으로 100배상에서 관찰하였다. 결과는 다음과 같다. 1. 도재에 금속선을 삽입한 결과, 금속선을 삽입하지 않은 대조군에 비해 통계적 유의성 있는 굴곡계수 및 굴곡강도의 변화는 관찰할 수 없었으나, 변형률의 유의성 있는 증가(P<.001)를 관찰할 수 있었다. 2. 금속선을 삽입한 시편의 파절 양상은 하중점 부위에서 도재만 파절되는 양상을 나타내었다. 3. 금속선을 삽입한 도재의 파절된 시편을 횡절단 및 종절단하여 100 배상에서 주사전자현미경으로 촬영한 결과, 하중 시 도재의 파절 원인이 될 수 있는 도재 내부의 기포는 관찰되지 않았으며, 도재와 금속선 사이의 gap도 관찰되지 않았다. 결론: 금속선 삽입의 결과, 취성 재료인 도재의 통계적으로 유의성 있는 변형률의 증가를 관찰할 수 있었다. 그러나 구치부에서 금속선 강화 도재의 사용을 위해서는 굴곡계수 및 굴곡강도의 향상이 필요하다. 이를 위해서는 추가적 연구가 필요하다.