• Title/Summary/Keyword: List Mode

Search Result 68, Processing Time 0.021 seconds

Temporal Directmode for B Picture in H.264 / MPEG-4 AVC (H.264 / MPEG-4 AVC에서의 B 픽쳐를 위한 시간적 다이렉트 모드)

  • 전병문
    • Journal of Broadcast Engineering
    • /
    • v.7 no.4
    • /
    • pp.300-309
    • /
    • 2002
  • The object of this paper is to make temporal direct mode clear by providing a solution to the following problem : if the co-located block in the list 1 reference picture for direct mode has only the 1ist 1 motion vector or both the 1ist 0 and list 1 motion vectors, then which motion vector will be used for the direct mode motion vector calculation\ulcorner This paper also shows how to derive reference picture index and direct mode motion vector for each list in order to guarantee the high coding efficiency. when the co-located macroblock is in intra mode. Furthermore, the reasonable calculation methods for the direct mode motion vectors in the various cases are presented. Finally, experimental results show that the proposed temporal direct mode provides the comparable performance against the spatial direct mode. Therefore, the simulation proves that the proposed temporal direct mode is acceptable.

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

Efficient Inter Prediction Mode Decision Method for Fast Motion Estimation in High Efficiency Video Coding

  • Lee, Alex;Jun, Dongsan;Kim, Jongho;Choi, Jin Soo;Kim, Jinwoong
    • ETRI Journal
    • /
    • v.36 no.4
    • /
    • pp.528-536
    • /
    • 2014
  • High Efficiency Video Coding (HEVC) is the most recent video coding standard to achieve a higher coding performance than the previous H.264/AVC. In order to accomplish this improved coding performance, HEVC adopted several advanced coding tools; however, these cause heavy computational complexity. Similar to previous video coding standards, motion estimation (ME) of HEVC requires the most computational complexity; this is because ME is conducted for three inter prediction modes - namely, uniprediction in list 0, uniprediction in list 1, and biprediction. In this paper, we propose an efficient inter prediction mode (EIPM) decision method to reduce the complexity of ME. The proposed EIPM method computes the priority of all inter prediction modes and performs ME only on a selected inter prediction mode. Experimental results show that the proposed method reduces computational complexity arising from ME by up to 51.76% and achieves near similar coding performance compared to HEVC test model version 10.1.

A Method of Merge Candidate List Construction using an Alternative Merge Candidate (대체 병합 후보를 이용한 병합 후보 리스트 구성 기법)

  • Park, Do-Hyeon;Yoon, Yong-Uk;Do, Ji-Hoon;Kim, Jae-Gon
    • Journal of Broadcast Engineering
    • /
    • v.24 no.1
    • /
    • pp.41-47
    • /
    • 2019
  • Recently, enhanced methods on the inter merging have been being investigated in Versatile Video Coding (VVC) standardization which will be a next generation video coding standard with capability beyond the High Efficiency Video Coding (HEVC). If there is not enough motion information available in the neighboring blocks in the merge mode, zero motion candidate is inserted into the merge candidate list, which could make the coding efficiency decreased. In this paper, we propose an efficient method of constructing the merge mode candidate list to reduce the case that the zero motion is used as a candidate by generating an alternative merge candidate. Experimental results show that the proposed method gives the average BD-rate gain of 0.2% with the decoding time increase of 3% in the comparison with VTM 1.0.

A Design and Implementation of Control Application for Arduino Prime Smart Car

  • Park, Jin-Yang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.11
    • /
    • pp.59-64
    • /
    • 2016
  • In this paper, we design and implement an Application based on android platform, which can control arduino Prime Smart Car using Bluetooth communication. This Application consist of Bluetooth communication module, manual mode module, and line-tracer mode module. In the Bluetooth communication module, it checks the on/off status of Smartphone Bluetooth. If Bluetooth status is off, it activates Bluetooth, selects the corresponding device from Bluetooth device list, and connects with a pair. In order to reduce coding time, we implements Bluetooth communication using inherited class from android Bluetooth package. In the manual mode module, it implements six direction moving button and stop button, which can control arduino Prime Smart Car. In the line-tracer mode module, it implements Prime Smart Car with self-driving function using TCRT5000 sensor. And moving button and stop button is disabled.

FMEA Measures for Service Failure Management (서비스 실패 관리를 위한 FMEA 이용 방안)

  • Kim, Hyun Jung;An, Qin Rui;Kim, Soo Wook
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.1
    • /
    • pp.43-61
    • /
    • 2014
  • Purpose: This study identifies preventive measures for VOC management by analyzing the causes and effects of factors that contribute to high risk service failure using FMEA on KORAIL VOC data. Methods: Two research methods were used. First, a Risk Priority Number (RPN) was assigned to each KORAIL VOC based on Failure Mode and Effect Analysis (FMEA). Second, multiple regression analysis was run with RPN factors that include severity, occurrence, and detection as the independent variables and customer dissatisfaction as the dependent variable. Results: Multiple regression analysis showed that RPN factors including severity, occurrence, and detection had significantly positive relationship with customer dissatisfaction. Based on these results, an FMEA was performed on VOC categories with high RPN for railroad stations including platform, ticketing, ticket verification, parking, and escalator, and VOC categories with high RPN for trains including entrance doors, cafes, air quality, announcement, and ticket verification. Conclusion: This study has practical implications to service failure management. A priority order using FMEA was established for the list of customer dissatisfactions that should be addressed to actively manage service failure, and strategies for tackling this priority list are offered.

Evaluation about a Usefulness of ECG-Gated Scan on 13N-ammonia PET (13N-ammonia 심장 PET 검사에서 ECG gated scan의 유용성 평가)

  • Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.20-23
    • /
    • 2016
  • Purpose Because of heart movement, PET image of heart is very blur. So, PET scan gated with ECG is necessary to improve a spatial resolution of heart PET image. In this study, we will evaluate a image quality of both gated $^{13}N-ammonia$ PET scan and non-gated one. Materials and Methods Before start a heart PET, we attached a ECG electrode on patients (n = 5, $aged=54{\pm}17$). And we started a list mode PET scan that used by a mCT40 PET/CT (siemens, germany) during 10 minute, injected $^{13}N-ammonia$ ($378{\pm}50MBq$) to a patients at same time. By using this list mode data, we reconstructed both gated PET image and non-gated PET image. Then we analysed a profiles of those images, performed a blind test, and subtracted a gated image on non-gated image. Results FWHM of a gated image is improved about 23% and there is a differency count distribution at a subtracted image from non-gated image to a gated image. But in case of blind test, everybody select the gated image as a better quality among each images. Conclusion As a result, we can find that image quality will improve by using gated PET scan. In additional, we can calculate a EF valve, apply QGS, QPS of PET. Therefore, the gated PET scan help improving an accuracy, applying a more information for a diagnosis.

  • PDF

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF

A security problem and its solution in Ipsec (IPsec의 보안상 문제점과 해결방안)

  • Kim, Jung-Hyun;Won, You-Jip;Im, Eul-Gyu
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.37-38
    • /
    • 2006
  • In this paper, we describe a security problem of IPsec. And we propose a solution for this problem. The problem is a fragility of IPsec Gateway which is used in tunnel mode. The role of IPsec Gateway is encrypting or decrypting IPsec packets. Because of the role of IPsec Gateway, IPsec Gateway suffers overhead for decrypting numerous packets. Adversaries can easily attack IPsec Gateway using a DDoS attack. To solve this problem, we propose the "Priority based Random Packet Drop" method. In this method, the white list which is a list of normal users is created. After that, according to the frequency of uses, the method marks priorities of random drops to the white list. If anomalous traffic appeared, this method will drop many packets which consist of anomalous traffic. In simple experiment, we show our solution is proper to defend IPsec Gateway. For this experiment, we use empirical backbone traffic which includes DoS attacks.

  • PDF

Failure Mode Effective Analysis for selection of Single Point Vulnerability in New type Nuclear Power Plant (신규노형 원전의 발전정지유발기기 선정을 위한 고장모드영향분석)

  • Hyun, Jin Woo;Yeam, Dong Un
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • For decreasing an unexpected shutdown of Nuclear Power Plants, Korea Hydro & Nuclear Power co.(KHNP) has developed Single Point Vulnerability(SPV) of NPPs since 2008. SPV is the equipment that cause reactor shutdown & turbine trip or more than 50% power rundown due to its malfunction. New type Nuclear Power Plants need to develop the SPV list, so performed the SPV selection for about 1 year. To develop this, Failure Mode Effect Analysis(FMEA) methods are used. As results of FMEA analysis, about 700 equipment are selected as SPV. Thereafter those are going to be applied to new type Nuclear Power Plants to enhance equipment reliability.