• 제목/요약/키워드: Liquid sensor

검색결과 316건 처리시간 0.036초

디스플레이 패널에 집적이 가능한 적외선 포토센서 (Integrated IR Photo Sensor for Display Application)

  • 전호식;허양욱;이재표;한상윤;배병성
    • 한국정밀공학회지
    • /
    • 제29권11호
    • /
    • pp.1164-1169
    • /
    • 2012
  • This paper presents a study of an integrated infrared (IR) photo sensor for display application. We fabricated hydrogenated amorphous silicon thin film transistor (a-Si:H TFT) and hydrogenated amorphous silicon germanium thin film transistor (a-SiGe:H TFT) which were bottom gate structure. We investigated the dependence of a-SiGe:H TFT characteristics on incident wavelengths. We proposed photo sensor which responded to wavelengths of IR region. Proposed pixel circuit of photo sensor was consists of switch TFT and photo TFT, and one capacitor. We developed integrated photo sensor circuit and investigated the performance of the proposed sensor circuit according to the input wavelengths. The developed photo sensor circuit with a-SiGe:H TFT was suitable for IR.

디지털 현미경 홀로그래피 기법을 이용한 마이크로 액체 제트 유동에 관한 실험적 연구 (Experimental Study on the Characteristics of Micro Jet Flow Using Digital Microscopic Holography)

  • 이한얼;이재호;신원규
    • 한국가시화정보학회지
    • /
    • 제16권1호
    • /
    • pp.48-53
    • /
    • 2018
  • In this study, the effect of injection pressure on the column diameter and droplet velocity of liquid jet with the weakly turbulent Rayleigh-like breakup mode is experimentally studied using digital microscopic holography (DMH). The injection nozzle has the diameter of $50{\mu}m$ and injection pressure is varied from 0.1 to 0.4 MPa. When the micro liquid jet is injected into still air, the double-pulsed holograms was recorded on a CCD sensor and numerically reconstructed in order to obtain well focused images. In this study, the liquid column diameter from $50{\mu}m$ orifice nozzle is shown to be changed slightly but the droplet velocity is increased proportionally as the injection pressure is increased.

풍력발전기 블레이드 변형 측정을 위한 액체금속 스트레인 게이지 개발 (Development of Liquid Metal Strain Gauge for Measuring WT Blade's Deformation)

  • 박인겸;서영호;김병희
    • 한국정밀공학회지
    • /
    • 제32권3호
    • /
    • pp.307-314
    • /
    • 2015
  • In this paper, the embedding type novel liquid metal strain gauge was developed for measuring the deformation of wind turbine blades. In general, the conventional methods for the SHM have many disadvantages such as frequency distortion in FBG sensors, the low gauge factor and mechanical failures in strain gauges and extremely sophisticated filtering in AE sensors. However, the liquid metal filled in a pre-confined micro channel shows dramatic characteristics such as high sensitivity, flexibility and robustnes! s to environment. To adopt such a high feasibility of the liquid metal in flexible sensor applications, the EGaIn was introduced to make flexible liquid metal strain gauges for the SHM. A micro channeled flexible film fabricated by the several MEMS processes and the PDMS replication was filled with EGaIn and wire-connected. Lots of experiments were conducted to investigate the performance of the developed strain gauges and verify the feasibility to the actual wind turbine blades health monitoring.

고로 용융물 레벨 변화 추정을 위한 디지털 필터 설계 (The Design of Filter for Hearth Liquid Level Estimation in Blast Furnace)

  • 조내수;한무호;권우현;최연호
    • 센서학회지
    • /
    • 제21권1호
    • /
    • pp.75-81
    • /
    • 2012
  • Optimizing the tapping time of a blast furnace is important to a stable operation and life extension. To optimize the tapping time of the blast furnace, the location of Hearth Liquid Level should be recognized. There are several ways to measure the hearth liquid level in the blast furnace, such as Electromotive Force(EMF) measurement, pressure measurement by putting in nitrogen probe and manometry with strain gauge. In this paper, it will be discussed using strain gauge among the three methods. Conventional strain gauge must be revised periodically. Since, internal pressure, temperature of internal refractory material and wind pressure have effect on the strain gauge. However, static pressure value is required to compensate. To solve these problems, this paper suggests finding relationship between Hearth Liquid Level and strain gauge output, adding digital filter in strain gauge. Using the proposed method, it was possible to estimate the hearth liquid level and determine the appropriate tapping time. Usefulness of the proposed method through simulations and experimental results are confirmed.

전기 절연유 열화진단을 위한 3-단자식 전기용량 센서 개발 및 진단특성 평가 (Development and Evaluation of 3-terminal Type Capacitive Sensor for the Diagnosis of Electrical Insulating Oil)

  • 김주한;한상옥
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.476-482
    • /
    • 2009
  • This paper describes the development of capacitive sensor for the diagnosis of liquid dielectrics, which is widely used as the electrical insulating oil of transformer, circuit breaker, cable and etc. To survey the dielectric properties of the virgin and aged electrical insulating oils, we utilized the highly precise measuring system, using the principle of cross capacitance. The measured properties were used to determine the design factors of the sensor. Then the factors were optimized with the help of computational analysis. To evaluate diagnosis by the sensor, we performed accelerated thermal aging test about electrical insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor. And to evaluate the hysteresis characteristics with the change of temperature, we constructed a testing system, which was composed with vacuum drying oven, oil chamber and measuring instruments, such as LCR meter, MUX and so forth. Through the results of this investigation, we confirmed the superior characteristics of the newly developed sensor.

PVC 및 GC물질의 혼합액을 코팅한 QCM가스센서의 센싱 및 열화특성 (Sensing and Degradation Properties in the QCM Gas Sensor Coated with the PVC and GC Blended Liquid)

  • 장경욱;김명호;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.483-486
    • /
    • 2000
  • In the recognition of the gases using the quartz crystal rnicrobalance (QCM) coated with the film materials, it is important to obtain the recognition ability of gases, and the stability of film coated above the QCM. Especially, the thickness of film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing chararcteristics of film is changed with these. In this paper, we coated the lipid GC materials varing with the blended amount of PVC(Po1y Vinyl Chloride) and solution (Tetra Hydrofan:THF) above QCM to obtain the stability of lipid PC film. QCM gas sensors coated with film materials were measured the frequency change in the chamber of stationary gas sensing system injected 1-hexane, ethyl acetate, ethanol and benzene of 20.4 respectively. Also, we measured the degradation characteristics of QCM gas sensor to show the properties of stability.

  • PDF

개방형 우물 구조를 이용한 마이크로머신형 pH 센서 (Micromachined pH Sensor Using Open Well Structures)

  • 김흥락;김영덕;정우철;김광일;김동수
    • 비파괴검사학회지
    • /
    • 제22권4호
    • /
    • pp.347-353
    • /
    • 2002
  • 수용액에 포함된 수소이온$(H^+)$의 농도를 측정하는 유리 전극형 수소이용 농도(pH) 센서의 기본 구조를 bulk micromachining 기술로 구현하여 소형의 pH 센서를 제작하였다. 박막 증착이 가능한 경사 식각으로 개방된 2개의 기본 구조물을 형성하고, 일정 전위를 유지하기 위한 기준전극은 식각된 구조물 경사면에 박막형 Ag/AgCl으로 확보하였다. $H^+$과 교환 반응으로 전위를 발생시키는 감응부는 Na이 20%이상 포함된 glass로 $100{\mu}m$ 내외로 미세 연마하여 기본 구조물에 접합하여 완성하였다. 또한 외부 용액과 기준 용액의 혼합을 방지하면서 전류 도통 역할을 하는 액간 접촉부는 $50{\mu}m{\times}50{\mu}m$ 크기의 Si 이방성 식각 부분에 한천을 삽입하고 난 다음 기존의 구조물에 접합하여 형성하였다. 각 구조물을 완성한 다음 2M 농도의 KCI 기준 용액을 구조물에 채우고, 상용 에폭시로 센서 구조물을 밀봉하여 센서를 완성하였다. 제작된 pH 센서들은 표준 pH 용액에 대하여 약 90mV/pH의 전위값이 측정되었다.

가솔린 송유관에서의 수액적 거동 특성 (Characteristics of Water Droplets in Gasoline Pipe Flow)

  • 김정헌;김승규;배충식;신동현
    • 한국분무공학회지
    • /
    • 제6권1호
    • /
    • pp.18-24
    • /
    • 2001
  • Liquid fossil fuel contaminated by water can cause trouble in the combustion processes and affect the endurance of a combustion system. Using an optical sensor to monitor the water content instantaneously in a fuel pipeline is an effective means of controlling the fuel quality in a combustion system. In two component liquid flows of oil and water, the flow pattern and characteristics of water droplets are changed with various flow conditions. Additionally, the light scattering of the optical sensor measuring the water content is also dependent on the flow patterns and droplet characteristics. Therefore, it is important to investigate the detailed behavior of water droplets in the pipeline of the fuel transportation system. In this study, the flow patterns and characteristics of water droplets in the turbulent pipe flow of two component liquids of gasoline and water were investigated using optical measurements. The dispersion of water droplets in the gasoline flow was visualized, and the size and velocity distributions of water droplets were simultaneously measured by the phase Doppler technique. The Reynolds number of the gasoline pipe flow varied in the range of $4{\times}10^{4}\;to\;1{\times}10^{3}$, and the water content varied in the range of 50 ppm to 300 ppm. The water droplets were spherical and dispersed homogeneously in all variables of this experiment. The velocity of water droplets was not dependent on the droplet size and the mean velocity of droplets was equal to that of the gasoline flow. The mean diameter of water droplets decreased and the number density increased with the Reynolds number of the gasoline flow.

  • PDF

Thermo-optic Characteristics of Micro-structured Optical Fiber Infiltrated with Mixture Liquids

  • Wang, Ran;Wang, Yuye;Miao, Yinping;Lu, Ying;Luan, Nannan;Hao, Congjing;Duan, Liangcheng;Yuan, Cai;Yao, Jianquan
    • Journal of the Optical Society of Korea
    • /
    • 제17권3호
    • /
    • pp.231-236
    • /
    • 2013
  • We present both theoretically and experimentally the thermo-optic characteristics of micro-structured optical fiber (MOF) filled with mixed liquid. The performance of MOF depends on the efficient interaction between the fundamental mode of the transmitted light wave and the tunable thermo-optic materials in the cladding. The numerical simulation indicates that the confinement loss of MOF presents higher temperature dependence with higher air-filling ratios $d/{\Lambda}$, longer incident wavelength and fewer air holes in the cladding. For the 4cm liquid-filled grapefruit MOF, we demonstrate from experiments that different proportions of solutions lead to tunable temperature sensitive ranges. The insertion loss and the extinction ratio are 3~4 dB and approximate 20 dB, respectively. The proposed liquid-filling MOF will be developed as thermo-optic sensor, attenuator or optical switch with the advantages of simple structure, compact configuration and easy fabrication.

헤테로코어형 광파이버 압력센서개발을 위한 기초연구 (A Basic Study on Development of the Hetero-core Type Fiber Optic Pressure Sensor)

  • 김영복
    • 유공압시스템학회논문집
    • /
    • 제7권2호
    • /
    • pp.1-6
    • /
    • 2010
  • A new type fiber optic sensing system has been developed as a commercially available standard using the technique of hetero-core spliced fiber optic sensor, for the purposes of monitoring large scaled structures, preserving natural environments and measuring physical phenomenons. The sensing system has been tested and evaluated in a possible outdoor condition in view of the full scaled operation at actual sites to be monitored. Additionally, the developed system in this work conveniently provides us with various options of sensor modules intended to measure such physical quantities as displacement, distortion, pressure, binary states and liquid adhesion. The experiment study has been performed to examine the performance to a pseudo-cracking experiment in the outdoor situation, and to clarify temperature influences to the system in terms of the coupling of optical connectors and the OTDR stability. It has been verified that the sensing system is robust to the temperature change ranging from the general condition to the hard condition. Especially, in this study, the specification and performances of the pressure sensor have been demonstrated to show the capability of inspecting various physical quantities.

  • PDF