Development of Surface Acoustic Wave Sensor for Viscosity Measurement of Low Viscose Liquid Using Love Wave (Love파를 이용한 저점성 유체 점도 측정용 표면 탄성파 센서 개발)

  • Lee, Sang-Dae;Kim, Ki-Bok;Lee, Dae-Su
    • Journal of Biosystems Engineering
    • /
    • v.33 no.4
    • /
    • pp.282-287
    • /
    • 2008
  • Love wave is one of the shear horizontal waves and it can propagate between two layers in liquid without energy loss. The SAW (surface acoustic wave) sensor using Love wave is very useful for real time measurement of the viscosity of liquid with high sensitivity. In this study, the 77 MHz and 155 MHz Love wave SAW sensors were fabricated and use to measure the viscosity of low viscous liquid. To generate the surface acoustic wave, the inter-digital transducers were fabricated on the quartz crystal wafer. In order to obtain the optimal thickness of the coating film (novolac photoresist) generating the Love wave on the surface of SAW device, theoretical calculation was performed. The performances of fabricated Love wave SAW sensors were tested. As test liquid, pure water and glycerol solutions having different concentrations were used. Since the determination coefficients of the regression equations for measuring the viscosity of liquid are greater than 0.98, the developed Love wave SAW sensors in this study will be very useful for precise measurement of viscosity of liquid.

The tilt angle detection using the piezoelectricity acceleration sensor (피에조 가속도 센서를 이용한 기울기 각도 검출)

  • Kim, Jin-Seok;Cho, Young-Jin;Kim, Young-Tark
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.946-949
    • /
    • 2004
  • It is necessary to detect the tilt angle for control or monitoring of various systems such as ship, aircraft recreation facilities etc as well as bridge or building systems. However the electronic liquid charge type tilt sensor which is one of typical tilt sensor has many problems. Those are remarkably slow response time and limited mounting condition because or liquid viscosity coefficient and inertia etc. In this study we propose a tilt angle instrumentation method using piezoelectricity acceleration sensor. The method can he applied on moving mount We verified the validity of the method through experiment.

  • PDF

Development of Smart Cargo Level Sensors Including Diagnostics Function for Liquid Cargo Ships (액체운반용 선박을 위한 진단기능을 가지는 스마트 카고 센서 개발)

  • Bae, Hyeon;Kim, Youn-Tai;Park, Dae-Hoon;Kim, Sung-Shin;Choi, Moon-Ho;Jang, Yong-Suk
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.3
    • /
    • pp.341-346
    • /
    • 2008
  • This paper is to develop a monitoring system with diagnosis for smart cargo sensors that is for management and maintenance of the liquid cargo ships. The main goal of the system is to achieve the total automation system of the cargo sensor. By this study, the active smart sensor for the liquid cargo ships is designed and developed that guarantees high-confidence, stability, and durability. The proposed system consists of a monitoring part of the steam pressure, high-level monitoring, over flowing monitoring, gas monitoring, and tank temperature monitoring. The signals transferred from each unit system are used for sensor diagnosis based on confidence and accuracy. Finally, in this study, the total supervisory monitoring system is developed to maintain and manage the cargo effectively based on fault diagnosis and prognosis of the each sensor system.

An Amperometric Proton Selective Sensor with an Elliptic Microhole Liquid/Gel Interface for Vitamin-C Quantification

  • Faisal, Shaikh Nayeem;Hossain, Md. Mokarrom;Lee, Hye-Jin
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.2
    • /
    • pp.121-126
    • /
    • 2010
  • An amperometric ascorbic acid selective sensor utilizing the transfer reaction of proton liberated from the dissociation of ascorbic acid in aqueous solution across an elliptic micro-hole water/organic gel interface is demonstrated. This redox inactive sensing platform offers an alternative way for the detection of ascorbic acid to avoid a fouling effect which is one of the major concerns in redox based sensing systems. The detection principle is simply measuring the current change with respect to the assisted transfer of protons by a proton selective ionophore (e.g., ETH 1778) across the micro-hole interface between the water and the polyvinylchloride-2-nitrophenyloctylether gel phase. The assisted transfer reaction of protons generated from ascorbic acid across the polarized micro-hole interface was first characterized using cyclic voltammetry. An improved sensitivity for the quantitative analysis of ascorbic acid was achieved using differential pulse stripping voltammetry with a linear response ranging from 1 to $100\;{\mu}M$ concentrations of ascorbic acid. As a demonstration, the developed sensor was applied for analyzing the content of vitamin-C in different types of commercial pharmaceutical tablets and syrups, and a satisfactory recovery from these samples were also obtained.

Imaging the Enzymatic Reaction of Urease Using Liquid Crystal-Based pH Sensor

  • Hu, Qiong-Zheng;Jang, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.12
    • /
    • pp.4377-4381
    • /
    • 2011
  • In this study, real-time and label-free methods for monitoring the enzymatic reaction of urease, which releases ammonia through the hydrolysis of urea in an aqueous solution, were developed using a liquid crystal (LC)-based pH sensor. Nematic liquid crystal 4-cyano-4'-pentylbiphenyl (5CB), doped with 4'-pentyl-biphenyl-4-carboxylic acid (PBA), exhibited a shift in optical appearance from bright to dark when it was in contact with ammonia generated from the enzymatic reaction between urease and urea. This optical change was attributed to the anchoring transitions of LCs caused by hydrophobic interactions between the tails of deprotonted PBA ($PBA^-$) molecules and the LCs at the aqueous/LC interface. This novel technique holds great promise for the sensitive detection of urease along with its substrates and inhibitors.

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

Implementation of Sensor Controller and Monitering System Using Film Type (필름형 센서를 이용한 센서 제어기 및 모니터링 시스템 구현)

  • Park, No-Jin;Lee, Ho-Woong;Yu, Hong-Kyeun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.1
    • /
    • pp.51-57
    • /
    • 2013
  • Leak detection, the system is controlled by humanity's precious water resources, prepare for natural disasters and prevent damage to buildings and various industrial facilities. Especially because it causes serious environmental pollution, chemicals or oil spills, leak detection of various liquid(oil, water), the point at which the liquid leak is detected early on, and minimize environmental pollution, prevent damage of the equipment due to the leak, and the country's precious water resources to be used safely. In this paper, we solve these problems by using specialized film sensor, any person who is not a skilled technician, equipment or walls anywhere can be easily installed. also reduce unnecessary circuit, If film sensor is connected to operate, have a big competitive price, the detection of liquid and the surrounding environment according to, the sensor film that can set the sensitivity control, and monitoring system was implemented.

A Study on the Tank Liquid-Level Monitoring Sensor Systems for Large Scaled Vessels (대형선박의 액체 탱크용 수위 모니터링 센서 시스템 연구)

  • Sohn, Kyung-Rak;Kim, Jin-Wook;Cho, Seok-Je;Shim, Joon-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.330-335
    • /
    • 2009
  • A fiber-optic liquid level sensor based on bending cantilever beam has been proposed. A fiber Bragg grating(FBG) embedded in the cantilever beam is used to sensing elements. The basic concept is elongation and constriction of the FBG corresponding to the liquid level variation. The best FBG position on the cantilever for obtaining the high sensitivity was 4 cm from the fixing point. When the liquid level moves up and down vertically, the Bragg wavelength is linearly shifted. But, the wavelength sensitivity of the FBG installed on the upper side of cantilever was four times better than that of the FBG equipped in the lateral side due to the difference of unit strain applied to the FBG. Intensity demodulation using the low-cost edge filter is used to interrogate the Bragg wavelength through converting the wavelength signals into the optical intensity ones. Experiment results show that the electrical output is exponentially proportional to the liquid level. But, it should be overcome for applying to the ships.

Automated Verification of Livestock Manure Transfer Management System Handover Document using Gradient Boosting (Gradient Boosting을 이용한 가축분뇨 인계관리시스템 인계서 자동 검증)

  • Jonghwi Hwang;Hwakyung Kim;Jaehak Ryu;Taeho Kim;Yongtae Shin
    • Journal of Information Technology Services
    • /
    • v.22 no.4
    • /
    • pp.97-110
    • /
    • 2023
  • In this study, we propose a technique to automatically generate transfer documents using sensor data from livestock manure transfer systems. The research involves analyzing sensor data and applying machine learning techniques to derive optimized outcomes for livestock manure transfer documents. By comparing and contrasting with existing documents, we present a method for automatic document generation. Specifically, we propose the utilization of Gradient Boosting, a machine learning algorithm. The objective of this research is to enhance the efficiency of livestock manure and liquid byproduct management. Currently, stakeholders including producers, transporters, and processors manually input data into the livestock manure transfer management system during the disposal of manure and liquid byproducts. This manual process consumes additional labor, leads to data inconsistency, and complicates the management of distribution and treatment. Therefore, the aim of this study is to leverage data to automatically generate transfer documents, thereby increasing the efficiency of livestock manure and liquid byproduct management. By utilizing sensor data from livestock manure and liquid byproduct transport vehicles and employing machine learning algorithms, we establish a system that automates the validation of transfer documents, reducing the burden on producers, transporters, and processors. This efficient management system is anticipated to create a transparent environment for the distribution and treatment of livestock manure and liquid byproducts.

Enhanced Adhesion and Transmittance Uniformity in Laminated Polymer-Dispersed Liquid Crystal Films

  • Yoo, Seong-Hyeon;Park, Min-Kyu;Park, Ji-Sub;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.753-761
    • /
    • 2014
  • We propose a two-step UV irradiation procedure to fabricate polymer-dispersed liquid crystal (PDLC) films by lamination. During the first UV treatment, before lamination, the UV-curable monomers coated on one film substrate are solidified through photo-polymerization as the phase separation between the liquid crystals and the monomers. Introducing an adhesion-enhancement layer on the other plastic substrate and controlling the UV irradiation conditions ensure that UV-induced cross-linkable functional groups remain on the surfaces of the photo-polymerized layers. Thereby, the adhesion stability between the top and bottom films is much improved during a second (post-lamination) UV treatment by further UV-induced cross-linking at the interface. Because the adhesion-enhancement and PDLC layers prepared by the bar-coating process are solidified before lamination, the PDLC droplet distribution and the cell gap between the two plastic substrates remain uniform under the lamination pressure. This ensures that the voltage-controlled light transmittance is uniform across the entire sample.