• Title/Summary/Keyword: Liquid Liquid Extraction

Search Result 1,075, Processing Time 0.03 seconds

Optimization of Extraction and Clarification Condition for Preparation of Liquid Extract Tea from Artificially Cultivated Phellinus linteus (인공재배 상황버섯 액상추출차 제조를 위한 최적추출 및 청징화 조건)

  • Song, Hyo-Nam;Oh, Se-Wook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.4
    • /
    • pp.636-641
    • /
    • 2002
  • Optimum extraction condition and clarification process were investigated to manufacture liquid extract tea using Phellinus linteus. Carbohydrates content in the raw Phellinus linteus was 80.9%. Major minerals were K, Ca, Fe and Na, but vitamin B$_1$, B$_2$, and C were not detected. The best extraction condition was 5% raw material at 10$0^{\circ}C$ within 3 hr. To clarify the extract, three methods of filtration with depth filter pad, centrifugation and addition of several filter aids were studied. Filtration with depth filter pad and centrifugation were highly effective on the clarification and the changes in the turbidity for 7 weeks at 4$0^{\circ}C$ were not occurred. The optimum clarification condition was centrifugation above 6,000 rpm or filtration with 8 ${\mu}{\textrm}{m}$ depth filter pad.

Determination of Ceftiofur Residues by Simple Solid Phase Extraction Coupled with Liquid Chromatography-Tandem Mass Spectrometry in Eel, Flatfish, and Shrimp

  • Kim, Joohye;Shin, Dasom;Kang, Hui-Seung;Lee, Eunhye;Choi, Soo Yeon;Lee, Hee-Seok;Cho, Byung-Hoon;Lee, Kang-Bong;Jeong, Jiyoon
    • Mass Spectrometry Letters
    • /
    • v.10 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • The aim of this study was conducted to develop an analytical method to determine the concentration of ceftiofur residue in eel, flatfish, and shrimp. For derivatization and extraction, the sample was hydrolyzed with dithioerythritol to produce desfuroylceftiofur, which was then derivatized by iodoacetamide to obtain desfuroylceftiofur acetamide. For purification, the process of solid phase extraction (Oasis HLB) was used. The target analytes were confirmed and quantified in $C_{18}$ column using liquid chromatography-tandem mass spectrometry with 0.1% formic acid in water (A) and 0.1% formic acid in acetonitrile (B) as the mobile phase. The linearity of the standard calibration curve was confirmed by a correlation coefficient, $r^2>0.99$. The limit of quantification for ceftiofur was 0.002 mg/kg; the accuracy (expressed as the average recoveries) was 80.6-105%; the precision (expressed as the coefficient of variation) was below 6.3% at 0.015, 0.03, and 0.06 mg/kg. The validated method demonstrated high accuracy and acceptable sensitivity to meet the Codex guideline requirements. The developed method was tested using market samples. As a results, ceftiofur was detected in one sample. Therefore, it can be applied to the analysis of ceftiofur residues in fishery products.

Quantitative analysis method for zingiber officinale water extract using high-performance liquid chromatography

  • Mohd S. Md Sarip;Nik M.A. Nik Daud;Mohd A. Mohd Zainudin;Lokman H. Ibrahim;Syahrul A. Saidi;Zuhaili Idham;Adilah Anuar
    • Advances in materials Research
    • /
    • v.13 no.3
    • /
    • pp.233-241
    • /
    • 2024
  • Quantitative analysis of the Zingiber Officinale sample using subcritical water extraction (SWE) was developed employing High-Performance Liquid Chromatography (HPLC) to bolster the advancement of this innovative green extraction process. This research focuses on three principal ginger bioactive compounds: 6-gingerol, 6-shagoal, and 10-gingerol. Various stages were undertaken to establish the quantitative analysis method, encompassing the optimisation of HPLC operating conditions and the formulation of standard calibration curves, yielding individual compound equations. A robust correlation within the calibration curve was achieved, exhibiting an r2 value of 0.9814 and an RSD of 5.00%. A simultaneous, swift, and dependable method was established with an injection time of 20 minutes and an 8-minute delay between injections, in contrast to the previous HPLC analysis requiring a 45-minute injection time for detecting and quantifying all components. Notably, no post-treatment was applied after the SWE process. This advancement allows for potential future online measurement of Zingiber Officinale bioactive compounds extracted using subcritical water extraction through this technology.

Analysis of PAHs (polycyclic aromatic hydrocarbons) in Ground Coffee Using GC-tandem Mass Spectrometry and Estimation of Daily Dose (GC-tandem mass spectrometry를 이용한 분쇄원두커피 중 PAHs(polycyclic aromatic hydrocarbons) 분석법 연구 및 인체노출량 평가)

  • Jung, So-Young;Park, Ju-Sung;Son, Yeo-Joon;Choi, Su-Jeong;Lee, Yun-Jeong;Kim, Mi-Sun;Park, So-Hyun;Lee, Sang-Me;Chae, Young-Zoo
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.544-552
    • /
    • 2011
  • The purpose of this study was to develop an analytical method for determining 15 polycyclic aromatic hydrocarbons (PAHs) of EU priority using gas chromatography (GC)-tandem mass spectrometry (MS). The PAHs in ground coffee were analyzed after being extracted using methods such as saponification-liquid-liquid extraction, Soxhlet extraction, and solid-liquid extraction. The solid-liquid extraction method showed the greatest repeatability and most efficient reduction of the matrix effect. GC-tandem MS for the quantification of the 15 PAHs showed better resolution and lower limit of detections (LODs) than GC-MS-selected ion monitoring (SIM) and high performance liquid chromatography with fluorescence detector. LODs of this method for the ground coffee types were 0.002-0.1 ${\mu}g/kg$ and limit of quantifications (LOQs) were 0.006-0.2 ${\mu}g/kg$ The recoveries ranged from 52.6 to 93.3%. Forty-six commercial types of ground coffee were analyzed to determine their PAHs contamination levels. PAHs concentration ranged from ND to 5.988 ${\mu}g/kg$. This study was conducted with toxicity equivalence factors, the U.S. EPA recommendation to identify dietary risks for PAHs in different types of coffee. The estimated average daily dose of PAHs was $5.24{\times}10^{-8}$ mg/kg body weight/day.

Properties of Black Walnut hull Extracts with Extractive Conditions (추출조건에 따른 호두외피추출물의 특성)

  • Kim, Ho-Jung
    • Fashion & Textile Research Journal
    • /
    • v.8 no.4
    • /
    • pp.465-470
    • /
    • 2006
  • Walnut hull is a by-product from the Walnut tree, used as natural dyestuff from ancient times. This study was done to examine the effects of extractive conditions on the properties of walnut hull extracts for making efficient use of the walnut hull as a natural colorant. Aqueous extracts of walnut hull were prepared at various extractive concentration, temperature and time. Then they were characterized using UV-Vis. Spectrophotometer, FT-IR Spectrometer, Prep Liquid Chromatography, and Energy dispersive X-ray spectrometer. The aqueous extracts have two absorbency peaks of UV-Vis. Spectrum, shoulder type peak in the range of 270-280 nm and broad type band around 420 nm. Intensity of absorbency is increased with increase of extraction concentration and time. However, Boiling temperature extraction method showed the most efficiency of all. Intensity of absorbency is also affected by extraction pH. The Prep LC examined two kinds of isolated colorant with different molecular weight. FT-IR spectra of hull extracts showed an absorption band around $3400cm^{-1}$, the peaks at $1700-1600cm^{-1}$, which are characteristic of aromatic compounds with unsaturated ketone and benzene ring. It showed that the extraction contained some mineral ions, such as K, Ca, Si, Mg.

Solid-Phase Extraction of Curcuminoid from Turmeric Using Physical Process Method (물리적 가공법을 이용한 강황으로부터 Curcuminoid의 고체상추출)

  • Lee, Kwang-Jin;Yang, Hye-Jin;Jeong, Sang-Won;Ma, Jin-Yeul
    • Korean Journal of Pharmacognosy
    • /
    • v.43 no.3
    • /
    • pp.250-256
    • /
    • 2012
  • In order to extract the curcuminoid such as curcumin, demethoxycurcumin (DMC), and bisdemethoxycurcumin (BDMC) in turmeric (Curcuma longa), solvent extraction methods (dipping and ultrasonic extraction method) and solid-phase extraction (SPE) were used. RP-HPLC (reverse-phase high-performance liquid chromatography) and TLC (thin-layer chromatography) were used for identification and analysis the three curcuminoid. From the experimental results, it is evident that the percentage of curcuminoid extracted from turmeric by ultrasonic extraction method was higher than dipping method. The percentage of curcumin extracted from turmeric by pure methanol was higher than any aqueous methanolic composition. Moreover, the total peak area of three curcuminoid was above 92% in RP-HPLC using solid-phase extraction. These results will form a database for investigating the constituents of natural products and the resources of pharmaceutical, nutrition, and cosmetic products.

Solid-Phase Extraction of Caffeine and Catechin Compounds from Green Tea by Caffeine Molecular Imprinted Polymer

  • Jin, Yinzhe;Row, Kyung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.2
    • /
    • pp.276-280
    • /
    • 2007
  • In this work, caffeine and some catechin compounds + C, EC, EGC, and EGCG were extracted from green tea by using molecular imprinted polymers (MIP) as sorbent materials in a solid-phase extraction (SPE) process known as MISPE (molecular imprinted solid-phase extraction). For synthesis of MIP, caffeine was employed as the template, MAA as the monomer, EGDMA as the crosslinker, and AIBN as the initiator. A solution of caffeine (0.2 mg/mL in methanol) was utilized in the solid extraction cartridges following loading, washing, and elution procedures with acetonitrile, methanol, and methanol-acetic acid (90/10, %v/v) as the solvents, respectively. This solid-phase extraction protocol was applied for the extraction of caffeine and some catechin compounds from green tea. A comparison was made between the results obtained with the MIP cartridges and a traditional C18 reversed-phase cartridge. It was thereupon found that the recovery of caffeine by the MIPbased sorbent used in this work was almost two and four times greater than that by a commercially available C18 material. A quantitative analysis was conducted by high performance liquid chromatography (HPLC) using a C18 column (5 μm, 250 × 4.6 mm) with methanol/water (40/60, %v/v) as the mobile phase at a flow rate of 0.5 mL/min.

Optimization of an extraction method for the simultaneous quantification of six active compounds in the aril part of Orostachys japonicus using HPLC-UV

  • Gao, Dan;Kim, Jin Hyeok;Cho, Chong Woon;Yang, Seo Young;Kim, Young Ho;Kim, Hyung Min;Kang, Jong Seong
    • Analytical Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.153-159
    • /
    • 2021
  • In this study, we describe the development of a new high-performance liquid chromatography (HPLC) method for the simultaneous analysis of six bioactive compounds (including gallic acid, epicatechin 3-gallate, quercitrin, afzelin, quercetin, and kaempferol) from Orostachys japonicus. The extraction method was investigated and optimization of the extraction time (min), solvent composition (%), and solvent to material ratio were conducted. As a result, 30 min extraction with 50% methanol and 40:1 mL/g of solvent: material ratio achieved the highest extraction efficiency with a yield of 3.32 mg/g. Furthermore, the developed HPLC method was validated and the correlation coefficient (R) values were within the satisfactory range of 0.9995-0.9999 over the linearity range of 1.53-417 ㎍/mL. The limit of detection and limit of quantification for the six active components were between 0.03-0.08 ㎍/mL and 0.08-0.26 ㎍/mL, respectively. With these newly optimized and developed methods, four batches of O. japonicus were analyzed to confirm the high extraction efficiency of the method and the feasibility of an application.

Extraction Behavior of Am(III) and Eu(III) From Nitric Acid Using Room Temperature Ionic Liquid (질산용액으로부터 이온성 액체를 이용한 Am(III)과 Eu(III)의 추출 거동)

  • Kim, Ik-Soo;Chung, Dong-Yong;Lee, Keun-Young;Lee, Eil-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.347-357
    • /
    • 2018
  • The applicability of room temperature ionic liquids (RTILs), 1-alkyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([$C_nmim$] [$Tf_2N$]), was investigated for the extraction of Am(III) and Eu(III) from nitric acid using n-octyl(phenyl)-N,N-diisobutyl carbamoylmethyl phosphine oxide (CMPO) and tri-n-butylphosphate (TBP) as extractants. The distribution ratios of Am(III) and Eu(III) in CMPO-TBP/[$C_nmim$][$Tf_2N$] were measured as a function of various parameters such as the concentrations of nitric acid, CMPO, and TBP. The results were compared with those obtained in CMPO-TBP/n-dodecane (n-DD). With comparable concentrations of the extractants, the distribution ratios obtained with RTILs were much higher than those obtained with n-DD. It was observed that the extraction efficiency was less for Eu(III) than for Am(III). The extraction of Am(III) and Eu(III) decreased with increases in the feed acidity for all three RTILs. The results suggest that the extraction of Am(III) and Eu(III) by CMPO in RTILs from nitric acid proceeds through the cation-exchange mechanism. The distribution ratios of Am(III) and Eu(III) increased with increases in the concentration of CMPO for all three RTILs. A linear regression analysis of the extraction data resulted in a straight line with a slope of about 3, suggesting the involvement of 3 molecules of CMPO during the extraction process.

A study of analytical method for Benzo[a]pyrene in edible oils (식용유지 중 벤조피렌 분석법 비교 연구)

  • Min-Jeong Kim;jun-Young Park;Min-Ju Kim;Eun-Young Jo;Mi-Young Park;Nan-Sook Han;Sook-Nam Hwang
    • Analytical Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.291-299
    • /
    • 2023
  • The benzo[a]pyrene in edible oils is extracted using methods such as Liquid-liquid, soxhlet and ultrasound-assisted extraction. However these extraction methods have significant drawbacks, such as long extraction time and large amount of solvent usage. To overcome these drawbacks, this study attempted to improve the current complex benzo[a]pyrene analysis method by applying the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method that can be analyzed in a simple and short time. The QuEChERS method applied in this study includes extraction of benzo[a]pyrene into n-hexane saturated acetonitrile and n-hexane. After extraction and distribution using magnesium sulfate and sodium chloride, benzo[a]pyrene is analyzed by liquid chromatography with fluorescence detector (LC/FLR). As a result of method validation of the new method, the limit of detection (LOD) and quantification (LOQ) were 0.02 ㎍/kg and 0.05 ㎍/kg, respectively. The calibration curves were constructed using five levels (0.1~10 ㎍/kg) and coefficient (R2) was above 0.99. Mean recovery ratio was ranged from 74.5 to 79.3 % with a relative standard deviation (RSD) between 0.52 to 1.58 %. The accuracy and precision were 72.6~79.4 % and 0.14~7.20 %, respectively. All results satisfied the criteria ranges requested in the Food Safety Evaluation Department guidelines (2016) and AOAC official method of analysis (2023). Therefore, the analysis method presented in this study was a relatively simple pretreatment method compared to the existing analysis method, which reduced the analysis time and solvent use to 92 % and 96 %, respectively.