• Title/Summary/Keyword: Linear Region

Search Result 1,488, Processing Time 0.029 seconds

A Measurement of Kerma and Absorbed Dose in Photon Fields (Photon Beam에 대한 Kerma와 흡수선량의 측정)

  • Kim, Sung-Hee;Shin, Seung-Aea;Chu, Sung-Sil
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.77-82
    • /
    • 1986
  • Determination of the relation between the kerma(Kinetic Energy Released in Material) and the absorbed dose is one of the basic problems of dosimetry. Kerma and absorbed dose were measured for 6 MV X-ray from the high energy medical linear accelerator and $^{60}Co$ gamma-ray. The experimental results show that the absorbed dose in the transient equilibrium region practically coincide with the kerma in water and Al for $^{60}Co$. The maximum dose depths were $1.45g/cm^2$ for 6MV X-ray and $0.48g/cm^2\;for\;^{60}Co$ gamma-ray. The ratios of the absorbed dose at maximum build-up to the collision kerma at the surface, ($K^{att}$), were 0.949 for 6MV X-ray and 0.992 for $^{60}Co$ gamma-ray. No difference was found between water and Al when the standard field size was used. This results show that the dependence of $K^{att}$ on the material is very small.

  • PDF

Intra-night optical variability of AGN in COSMOS field

  • Kim, Joonho;Karouzos, Marios;Im, Myungshin;Kim, Dohyeong;Jun, Hyunsung;Lee, Joon Hyeop;Pallerola, Mar Mezcua
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.64.2-64.2
    • /
    • 2016
  • Optical variability is one way to probe the nature of the central engine of AGN at smaller linear scales and previous studies have shown that optical variability is more prevalent at longer timescales and at shorter wavelengths. Especially, intra-night variability can be explained through the damped random walk model but small samples and inhomogeneous data have made constraining this model hard. To understand the properties and physical mechanism of optical variability, we are performing the KMTNet Active Nuclei Variability Survey (KANVaS). Test data of KMTNet in the COSMOS field was obtained over 2 separate nights during 2015, in B, V, R, and I bands. Each night was composed of 5 and 9 epochs with ~30 min cadence. To find AGN in the COSMOS field, we applied multi-wavelength selection methods. Different selection methods means we are looking different region in unification model of AGN, and 100~120, 400~500, 50~100 number of AGN are detected in X-ray, mid-infrared, and radio selection of AGN, respectively. We performed image convolution to reflect seeing fluctuation, then differential photometry between the selected AGN and nearby stars to achieve photometric uncertainty ~0.01mag. We employed one of the standard time-series analysis tools to identify variable AGN, chi-square test. Preliminarily results indicate that intra-night variability is found for X-ray selected, Type1 AGN are 23.6%, 26.4%, 21.3% and 20.7% in the B, V, R, and I band, respectively. The majority of the identified variable AGN are classified as Type 1 AGN, with only a handful of Type 2 AGN showing evidence for variability. The work done so far confirms that there are type and wavelength dependence of intra-night optical variability of AGN.

  • PDF

A Study on the One Side Freezing /Thaw and Carbonation of Autoclaved Lightweight Concrete (경량기포콘크리트의 편면동결융해 및 탄산화에 관한 연구)

  • 노재성;황의환;홍성수;이범재
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.4
    • /
    • pp.149-156
    • /
    • 1995
  • The fracture process zone in concrete is a region ahead of a traction-free crack, in which two major mechanisms, microcracking and bridging, play important roles. The toughness due to bridging is dominant compared to toughness induced by microcracking, so that the bridging is dominani: mechanism governing the fracture process of concrete. Fracture mechanics does work for concrete provided that the fracture process zone is being considered, so that the development of model for the fracture process zone is most important to describe fracture phenomena in concrete. In this paper the bridging zone, which is a part of extended rnacrocrack with stresses transmitted by aggregates in concrete, is modelled by a Dugdale-Barenblatt type model with linear tension-softening curve. Two finite element techniques are shown for the analysis of progressive cracking in concrete based on the discrete crack approach: one with crack element, the other without crack element. The advantage of the technique with crack element is that it dees not need to update the mesh topology to follow the progressive cracking. Numerical results by the techniques are demonstrated.

Preparation and Characterization of Opacified Silica Aerogels Doped by TiO$_2$ (TiO$_2$ 첨가에 의한 불투명한 실리카 에어로겔의 합성 및 특성화)

  • 손봉희;현상훈
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.2
    • /
    • pp.159-166
    • /
    • 1999
  • The physical properties and microstructural changes with heat-treatment of opacified silica aerogels doped by TiO2 were investigated. Monolithic SiO2-TiO2 aerogels were prepared by supercritical drying (25$0^{\circ}C$, 1250 psig) of wet gel obtained by adding titanium isopropoxide to prehydrolyzed TEOS-isopropanol solutions. The density and the porosity of SiO2-10 mol% TiO2 aerogels were 0.23 g/㎤ and 90%, respectively. During supercritical drying, the linear shrinkage of aerogels increased with increase in the titanium content an TiO2 was transformed to the anatase phase as well as particls agglomerates led to TiO2 clusters of 100~800 nm dispersed homogeneoulsy in the silica matrix. The IR transmittance of opacified silica aerogels was very low in the region of wavelengths below 8 ${\mu}{\textrm}{m}$ compared with pure silica aerogels and SiO2-TiO2 aerogels showed the high thermal stability of microstructures up to $600^{\circ}C$.

  • PDF

Anatomical Review of Lateral Upper Arm Flap for the Oral and Maxillofacial Reconstruction (구강악안면재건을 위한 외측상완피판의 해부학적 고찰)

  • Seo, Mi Hyun;Kim, Soung Min;Kang, Ji Young;Myoung, Hoon;Lee, Jong Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.4
    • /
    • pp.286-292
    • /
    • 2012
  • The lateral upper arm flap (LUAF) was initially described by in 1982 by Song et al. as a simple skin flap, addressing the availability of cutaneous nerves for anastomoses. Katsaros et al., reported the use of a lateral upper arm skin flap, but also considered using it as a composite graft. The LUAF for the oral and maxillofacial reconstruction has several advantages over other flaps, such as constant anatomy, good color match and texture, thin design and plasticity. There is no functional limitation in the donor arm, such as strength and extension, and donor defects can be closed primarily with a linear scar, even when a flap of up to 8 cm in width is taken. For a better understanding of LUAF as a routine reconstructive option in moderate defect of maxillofacial region, the constant anatomical findings must be learned and memorized by young doctors during the specialized training course for the Korean national board of oral and maxillofacial surgery. This article review the anatomical basis of LUAF with Korean language.

The Statistically and Economically Significant Clustering Method for Economic Clusters in an Urban Region (통계적 및 경제적 유의성을 가진 경제 클러스터 탐식방법에 대한 연구)

  • Shin Jungyeop
    • Journal of the Korean Geographical Society
    • /
    • v.40 no.2 s.107
    • /
    • pp.187-201
    • /
    • 2005
  • With the trend of urban polynucleation, the issue of detecting economic clusters or urban employment centers has been considered as crucial. However, the prior researches had some limitations in detecting economic clusters in the empirical analysis: i.e. inherent inefficiency of density-based clustering methods, difficulty in detecting linear types of spatial clusters and lacks of consideration of economic significance. The purpose of this paper is to propose the clustering method with the procedure of testing statistical and economic significance named as VCEC (Variable Clumping method for Economic Clusters) and to apply it to a case analysis of Erie County, New York, in order to test its validity. By applying a search radius and a total employment as an economic threshold, 'the both statistically and economically significant clusters' were detected in the Erie County, and proved to be efficient.

Shear Behavior Prediction of Reinforced Concrete Columns Using Transformation Angle Truss Model (변환각 트러스 모델에 의한 철근콘크리트 기둥의 전단거동 예측)

  • Kim Sang-Woo;Chai Hyee-Dae;Lee Jung-Yoon;Lee Bum-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.435-444
    • /
    • 2005
  • This paper predicted the shear behavior of reinforced concrete columns using Transformation Angle Truss Model (TATM) considered the effects of bending moment and axial force. Nine columns with various shear span- to-depth ratios and axial force ratios were tested to verify the theoretical results obtained from TATM. Fine linear displacement transducers (LVDT) were attached to a side of the column near the shear critical region to measure the curvature, the longitudinal and transverse axial deformations, and the shear deformation of the column. The test was terminated when the value of the applied load dropped to about $85\%$ of the maximum-recorded load in the post-peak descending branch. All the columns were failed in shear before yielding of the flexural steel. The shear strength and the stiffness of the columns increased, as the axial force increased and the shear span-to-depth ratio decreased. Shear stress-shear strain and shear stress-strain of shear reinforcement curves obtained from TATM were agreed well with the test results in comparison to other truss models (MCFT, RA-STM, and FA-STM).

EQUIVALENT DOSE FROM SECONDARY NEUTRONS AND SCATTER PHOTONS IN ADVANCE RADIATION THERAPY TECHNIQUES WITH 15 MV PHOTON BEAMS

  • Ayuthaya, Isra Israngkul Na;Suriyapee, Sivalee;Pengvanich, Phongpheath
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.147-154
    • /
    • 2015
  • The scatter photons and photoneutrons from high energy photon beams (more than 10 MV) will increase the undesired dose to the patient and the staff working in linear accelerator room. This undesired dose which is found at out-of-field area can increase the probability of secondary malignancy. The purpose of this study is to determine the equivalent dose of scatter photons and neutrons generated by 3 different treatment techniques: 3D-conformal, intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). The measurement was performed using two types of the optically stimulation luminescence detectors (OSL and OSLN) in the Alderson Rando phantom that was irradiated by 3 different treatment techniques following the actual prostate cancer treatment plans. The scatter photon and neutron equivalent dose were compared among the 3 treatments techniques at the surface in the out-of-field area and the critical organs. Maximum equivalent dose of scatter photons and neutrons was found when using the IMRT technique. The scatter neutrons showed average equivalent doses of 0.26, 0.63 and $0.31mSv{\cdot}Gy^{-1}$ at abdominal surface region which was 20 cm from isocenter for 3D, IMRT and VMAT, respectively. The scattered photons equivalent doses were 6.94, 10.17 and $6.56mSv{\cdot}Gy^{-1}$ for 3D, IMRT and VMAT, respectively. For the 5 organ dose measurements, the scattered neutron and photon equivalent doses in out of field from the IMRT plan were highest. The result revealed that the scatter equivalent doses for neutron and photon were higher for IMRT. So the suitable treatment techniques should be selected to benefit the patient and the treatment room staff.

Properties of Low Operating Voltage MFS Devices Using Ferroelectric $LiNbO_3$ Film ($LiNbO_3$ 강유전체 박막을 이용한 저전압용 MFS 디바이스의 특징)

  • Kim, Kwang-Ho;Jung, Soon-Won;Kim, Chae-Gyu
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.11
    • /
    • pp.27-32
    • /
    • 1999
  • Metal-ferroelectric-semiconductor devices by susing rapid thermal annealed $LiNbO_3/Si$(100) structures were fabricated and demonstrated nonvolatile memory operations. The estimated field-effect electron mobility and transconductance on a linear region of the fabricated FET were about $600cm^2/V{\cdot}s$ and 0.16mS/mm, respectively. The ID-VG characteristics of MFSFET's showed a hysteresis loop due to the ferroelectric nature of the $LiNbO_3 films. The drain current of the on state was more than 4 orders of magnitude larger than the off state current at the same read gate voltage of 0.5V, which means the memory operation of the MFSFET. A write voltage as low as ${\pm}3V$, which is applicable to low power integrated circuits, was used for polarization reversal. The ferroelectric capacitors showed no polarization degradation up to $10^{10}$ switching cycles with the application of symmetric bipolar voltage pulse (peak-to-peak 6V, 50% duty cycle) of 500kHz.

  • PDF

Effect of different lateral occlusion schemes on peri-implant strain: A laboratory study

  • Lo, Jennifer;Abduo, Jaafar;Palamara, Joseph
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.45-51
    • /
    • 2017
  • PURPOSE. This study aims to investigate the effects of four different lateral occlusion schemes and different excursions on peri-implant strains of a maxillary canine implant. MATERIALS AND METHODS. Four metal crowns with different occlusion schemes were attached to an implant in the maxillary canine region of a resin model. The included schemes were canine-guided (CG) occlusion, group function (GF) occlusion, long centric (LC) occlusion, and implant-protected (IP) occlusion. Each crown was loaded in three sites that correspond to maximal intercuspation (MI), 1 mm excursion, and 2 mm excursion. A load of 140 N was applied on each site and was repeated 10 times. The peri-implant strain was recorded by a rosette strain gauge that was attached on the resin model buccal to the implant. For each loading condition, the maximum shear strain value was calculated. RESULTS. The different schemes and excursive positions had impact on the peri-implant strains. At MI and 1 mm positions, the GF had the least strains, followed by IP, CG, and LC. At 2 mm, the least strains were associated with GF, followed by CG, LC, and IP. However, regardless of the occlusion scheme, as the excursion increases, a linear increase of peri-implant strains was detected. CONCLUSION. The peri-implant strain is susceptible to occlusal factors. The eccentric location appears to be more influential on peri-implant strains than the occlusion scheme. Therefore, adopting an occlusion scheme that can reduce the occurrence of occlusal contacts laterally may be beneficial in reducing peri-implant strains.