• Title/Summary/Keyword: Line source method

Search Result 514, Processing Time 0.028 seconds

Harmonic Characteristic Analysis of a Modified Trapezoidal PWM Inverter (Modified Trapezoidal PWM 인버터 고조파 특성 해석)

  • 조우성;김인동;노의철;김만고;전성즙;조철제;문성득
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.256-259
    • /
    • 1999
  • A new PWM method for voltage source inverters is described. The switching instants determination of the proposed PWM scheme is simple. Therefore, hardware implementation with a microprocessor system is easy and high frequency operation of an inverter can be obtained. The maximum line-to-line output voltage of 3-phase inverter with the proposed scheme is larger than that of the SPWM inverter under a linear modulation region. Principle of the proposed PWM method is described and harmonic characteristic analysis is carried out.

  • PDF

PD Monitoring of Transformer Using UHF Technique (UHF 기술을 응용한 전력용 변압기의 PD 모니터링)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2116-2117
    • /
    • 2008
  • This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

DIRECT FREQUENCY REPRESENTATION OF PULSE PATTERNS FOR CONTROLLED VOLTAGE SOURCE INVERTERS

  • Oleschuk, Valentin;Bose, Bimal K.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.165-170
    • /
    • 1998
  • The paper describes developed method of feedforward digital modulation of line-to-line voltage of 3-phase inverter for drive application. It is based on representation of parameters of output voltage of inverter in function of operating frequency of drive system. Pure algebraic control laws and big computational simplicity characterize this scheme of modulation. It has been presented results of simulation of adjustable drive systems with the method of pulse-width modulation described.

  • PDF

Identification of Noise Source from Main Steam Line in Power Plant (발전소 주증기 배관 소음 발생 원인 규명)

  • Sohn, M.S.;Lee, J.S.;Lee, S.K.;Lee, W.R.;Lee, S.K.
    • Journal of Power System Engineering
    • /
    • v.7 no.3
    • /
    • pp.23-28
    • /
    • 2003
  • In heavy nuclear power plant, high energy through main steam line is provided to turbine that generate the electric power. Since plant had generated power, high noise has been occurred. Noise make equipments and work environment worse. For finding out the location and the cause of making noise, noise was measured along main steam line at open/close test of Main Steam Isolation Valve (MSIV hereafter). As the result, it was identified that the vortex shedding in the cavity of MSIV is main noise source. The profile change of MSIV seat ring was proposed as the method of noise reduction. After filletting MSIV seat ring, the noise level reduced $10{\sim}20dB$ compared before the change of profile.

  • PDF

Coincidence summing correction for a voluminous 152Eu source

  • Yoon, Eun Taek;Kang, Min Young;Kim, In Jung;Sun, Gwang Min;Choi, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1266-1270
    • /
    • 2020
  • A code is developed to correct for the coincidence summing effect in detecting a voluminous gamma source, and this code is applied to a152Eu standard source as a test case. The source is 1000 mL of liquid in a cylindrical shape. To calculate the coincidence summing effect, the cylindrical source is considered as 10(radial) × 8(height) sectional sources. For each sectional source, the peak efficiency and total efficiency are obtained by Monte Carlo simulation at each energy for 10 energies between 50 keV and 2000 keV. The efficiencies of each sector are then expressed as polynomials of gamma energy. To calculate the correction coefficients for the coincidence summing effect, the KORSUM code is used after modification. The magnitudes of correction are 4%-17% for the standard 152Eu source measured in this study. The relative deviation of 4.7% before the coincidence correction is reduced to 0.8% after the correction is applied to the efficiency based on the measured gamma line. Hence, this study has shown that a new method has been developed that is applicable for correcting the coincidence effect in a voluminous source, and the method is applied to the measured data of a standard 152Eu cylinder source.

Investigation for Multi-bit per Cell on the CSL-NOR Type SONOS Flash Memories (CSL-NOR형 SONOS 플래시 메모리의 멀티비트 적용에 관한 연구)

  • Kim Joo-Yeon;An Ho-Myoung;Lee Myung-Shik;Kim Byung-Cheul;Seo Kwang-Yell
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.3
    • /
    • pp.193-198
    • /
    • 2005
  • NOR type flash 32 ${\times}$ 32 way are fabricated by using the typical 0.35 ${\mu}{\textrm}{m}$ CMOS process. The structure of array is the NOR type with common source line. In this paper, optimized program and erase voltage conditions are presented to realize multi-bit per cell at the CSL-NOR array. These are considered selectivity of selected bit and disturbances of unselected bits. Retention characteristics of locally trapped-charges in the nitride layer are investigated. The lateral diffusion and vertical detrapping to the tunneling oxide of locally trapped charges as a function of retention time are investigated by using the charge pumping method. The results are directly shown by change of the trapped-charges quantities.

A Study on the High Integrated 1TC SONOS flash Memory (고집적화된 1TC SONOS 플래시 메모리에 관한 연구)

  • 김주연;김병철;서광열
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.5
    • /
    • pp.372-377
    • /
    • 2003
  • To realize a high integrated flash memory utilizing SONOS memory devices, the NOR type ITC(one Transistor Cell) SONOS flash arrays are fabricated and characterized. This SONOS flash arrays with the common source lines are designed and fabricated by conventional 0.35$\mu\textrm{m}$ CMOS process. The thickness of ONO for memory cells is tunnel oxide of 34${\AA}$, nitride of 73${\AA}$ and blocking oxide of 34${\AA}$ . To investigate operating characteristics, CHEI(Channel Hot Electron Injection) method and bit line method are selected as the program and 4he erase operation, respectively. The disturbance characteristics ,according to the program/erase/read cycling are also examined. The degradation characteristics are investigated and then the reliability of SONOS flash memory is guaranteed.

Identification of OH emission lines from IGRINS sky spectra and improved sky subtraction method

  • Lee, Jae-Joon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.72.2-72.2
    • /
    • 2019
  • The hydroxyl radical (OH) sky emission lines arise from the Earth's mesosphere, and they serve as a major source of the sky background in the infrared. With IGRINS, the observed line strength show non-negligible variation even within a few minutes of time scale, making its subtraction difficult. Toward the aim better sky subtraction in the IGRINS pipeline, we present 1) improved identification of sky lines in H and K band and 2) improved method of subtracting sky background. Using the recent line list of Brooke et al. (2015), we have detected ~500 OH doublets from upper vibrational level between 2 and 9 and maximum upper J level of 25. In particular, we found that a significant fraction of unidentified lines reported by Oliva et al. (2015) are indeed OH lines resulting from transitions between different F levels. With the extended line identification, we present an improved method of sky subtraction. The method, based on the method of Noll et al. (2014), empirically accounts non-LTE level population of OH molecules.

  • PDF

Joint Aspect Inspecting System Using Image Processing (영상처리를 통한 접합면 검사 시스템)

  • Kang, Won-Chan;Kim, Young-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • In this paper, we present the new method for joint aspect inspecting system. We use the image processing and laser maker for light source. We can find the matrial joint status through processing the line pattern which is made by laser maker. To get the line pattern, in first, we did the preprocess of threshold. If the shape of line had over two segments, then the joint status is abnormal. We show our system efficency by experiment on tire facility.

A Study on Fire Investigation Technique For Single Line to Ground Faults in Distribution Line Using EMTP Simulation (EMTP 시뮬레이션을 통한 배전선로의 1선 지락 사고시 화재 조사 기법에 관한 연구)

  • Yoo, Jeong Hyun;Kim, Hie Sik;Lee, Hoon Gi;Cho, Yong Sun
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.21-26
    • /
    • 2018
  • Approximately 20% of the total fire is electrical fire, and electrical energy is a potential source of heat. Large-scale fault currents that occur during a line ground fault flow into electric utility poles, electric power equipment, or electric appliances of the customer, and cause simultaneous electrical fire. In this paper, we investigated the possibility of fire through the change of fault current flowing in faulty and sound feeder in case of 1 line ground fault in 22.9 kV distribution line. We propose a fire investigation analysis method for simultaneous multiple electrical fire such as evidence analysis method, and fault current occurrence confirmation method in case of fire accident by analyzing the fault current occurring in the ground fault in the distribution line using EMTP, electric power system analysis program.