• Title/Summary/Keyword: Line scanner

Search Result 141, Processing Time 0.033 seconds

The CIS Image Scanning System Realization with Illumination Control (조도제어를 적용한 CIS 이미지 스케닝시스템 구현에 관한 연구)

  • 김영빈;이영우;류광렬
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.277-279
    • /
    • 2003
  • The black and white image scanning system realization and design using illumination control on CIS(Contact Image Sensor) be amenable to recognize a papers, OMR and OCR sheet is proposed. The design technique is used CIS scanning sensor in fixing step motor and is optimized with DSP processor for image processing, and transfer input image data pare line in feeding a step unit to PC on the USB interface. The method of illumination control is that turn on and off of CIS lamp while scanning paper. The scanner system with optimal illumination enhanced PSNR 0.3% in scanning image.

  • PDF

Evaluation of Physical Characteristics of Discovery ST scanner Using NEMA NU2-2001 Standard (NEMA NU2-2001을 이용한 PET-CT 스캐너의 물리적 특성평가)

  • Lee, Byeong-Il
    • Journal of Integrative Natural Science
    • /
    • v.1 no.2
    • /
    • pp.79-83
    • /
    • 2008
  • As a new standard for performance measurement, NEMA NU2-2001 was presented recently. In this study, I investigated the spatial resolution, sensitivity, scatter fraction, and noise equivalent count ratio (NECR) in order to know the information of physical characteristics and system performance of GE discovery ST using this new standard. Bismuth germinate crystals ($6{\times}6$ array, $6.3mm{\times}6.3mm{\times}30mm$) were used in discovery ST (energy window:375-650 keV, coincidence window:11.7 nsec). To measure the sensitivity, five aluminum sleeves (Data Spectrum Corp., Chapel Hill, NC., USA, thickness:1.25 mm)-NEMA sensitivity phantom- filled with F-18 solution were used. Successive measurements in 2D and 3D acquisition mode were made with a line source at the center of transaxial field of view and 10 cm off from the center until the count was over 500,000. Spatial resolution was estimated using a point source (F-18, 0.1 mCi) at different locations in the FOV. Scatter fraction and NECR was tested using a NEMA scatter phantom. Dynamic data were acquired for 7 half-lives using F-18 solution. And true to background ratio was averaged at last three frames when the random rate was as small as ignorable for the calculation of scatter fraction. We anticipate this overall evaluated results could be used for the quality assurance and optimized image acquisition for clinical research.

  • PDF

Microfabricated Cell Chip for Cell-based in vitro Assay

  • Park, Je-Gyun;Kim, Tae-Han;Lee, Sang-Eun;Kim, Su-Hyeon;Yun, Gyu-Sik;Lee, Jeong-Geon
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.115-118
    • /
    • 2000
  • A microfabricated cell chip was developed to evaluate drug effect on mouse B16-F1 melanoma cell line. The cell chip system consists of 8-well culture cartridge incorporated with interdigitated array gold electrodes on each well, lock-in amplifier, 8-well cell scanner and computer as a system controller. Impedance of an electrode is increased according to adherent cell growth on the electrode surface. In order to verify investigated. The change of impedance was measured differentially between a control electrode containing only media and cell-cultured sample electrodes with time.

  • PDF

A Study on Development of Automobile Interior Parts through Al-Insert Injection Moulding (Al-Insert 사출성형을 이용한 자동차 내장재 부품 개발에 관한 연구)

  • Lho T.J.;Kim J.Y.;Kang D.J.;Kim J.H.;Kim G.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.170-175
    • /
    • 2005
  • Generally, Aluminum is superior to durability, light, and characteristics of the material are embossed luminant. So, these characteristics of aluminum will be used automobile interior parts by aluminum injection moulding. Especially, The external of Aluminum plate is engraved differing pattern by roller working. This working can use any longer and be seen gracefully. This is the reason why aluminum insert moulding is used. This feature of research can be characterized by simple process to customize aluminum sheet of blanking and forming process with internal parts of configuration if products are injected by aluminum sheet. Besides, to analysis completed Automobile interior parts to be concerned volumetric shrinkage, best gate location, fill time analysis and so on through the mold-flow before the aluminum insert moulding is worked.

  • PDF

Implementation of Indoor Localization System

  • Ryu, Dong-Wan;Kim, Sun-Hyung;Jeong, Dong-Gyu
    • International journal of advanced smart convergence
    • /
    • v.8 no.3
    • /
    • pp.54-60
    • /
    • 2019
  • In this paper, a localization system for indoor objects is proposed. The proposed system consists of Beacons, LED Cells, Main Cell Controller (MCC), and Display. A Beacon is attached at each indoor object, and each LED cell has Beacon Scanner and VLC Transmitter. The Visual Light Communications (VLC) and Power Line Communications (PLC) methods are used to communicate the signals for localization of indoor objects. And the proposed system is designed, and implemented as a prototype. To certify that our propose d system can exactly localize a given indoor object, we take test for the implemented system as a p rototype. Here the location of the given indoor object is known. Test is done in two ways. The first is to check the operation of the detail of the system, and the second is the position recognition of i ndoor object. The second is the test of the implemented system to correctly detect the location of the indoor object with Beacon, while the object with Beacon is moved from location C to A. The experimental result shows that the system is exactly detect the moving locations. The system has the advantages of using previously installed power lines, and it does not need to use LAN lines or optical cables. The proposed system is usefully applied to indoor object localization area.

Study on the PET image quality according to various scintillation detectors based on the Monte Carlo simulation

  • Eunsoo Kim;Chanrok Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.129-132
    • /
    • 2023
  • Purpose: Positron emisson tomography (PET) is a crucial medical imaging scanner for the detection of cancer lesions. In order to maintain the improved image quality, it is crucial to apply detectors of superior performance. Therefore, the purpose of this study was to compare PET image quality using Monte Carlo simulation based on the detector materials of BGO, LSO, and LuAP. Materials and Methods: The Geant4 Application for Tomographic Emission (GATE) was used to design the PET detector. Scintillations with BGO, LSO and LuAP were modelled, with a size of 3.95 × 5.3 mm2 (width × height) and 25.0 mm (thickness). The PET detector consisted of 34 blocks per ring and a total of 4 rings. A line source of 1 MBq was modelled and acquired with a radius of 1 mm and length of 20 mm for 20 seconds. The acquired image was reconstructed maximum likelihood expectation maximization with 2 iteration and 10 subsets. The count comparison was carried out. Results and Discussion: The highest true, random, and scatter counts were obtained from the BGO scintillation detector compared to LSO and LuAP. Conclusion: The BGO scintillation detector material indicated excellent performance in terms of detection of gamma rays from emitted PET phantom.

A Study on Optical Coherence Tomography System by Using the Optical Fiber (광섬유를 이용한 광영상단층촬영기 제작에 관한 연구)

  • 양승국;박양하;장원석;오상기;이석정;김기문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.34-40
    • /
    • 2004
  • In this paper, we have studied the OCT(Optical Coherence Tomography) system which has been advantages of high resolution, 2-D cross-sectional images, low cost and small size configuration. The characteristics of light source determine the resolution and coherence length. The light source has a commercial SLD with a central wavelength of 1,285 ill11, 35.3 nm(FWHM). The optical delay line is necessary to make equal with the optical path length to scattered light or reflected light from a sample. In order to make equal the optical path length, the stage that is attached to a reference mirror is controled by a step motor. And the interferometer is configured with the Michelson interferometer by using a single mode fiber, and the scanner can be focused on the sample by using a reference ann Also, the 2-dimension cross-sectional images were measured with scanning the transverse direction of the sample by using a step motor. After detecting the internal signal of lateral direction, a scanner is moved to obtain the cross-sectional image of 2-dimension by using step motor. A photodiode, which has high detection sensitivity and excellent noise characteristics has been used. The detected small signal has a noise and interference. After filtering and amplifying the signal, the output signal is demodulated the waveform And then, a cross-sectional image is seen through converting this signal into a digitalized signal by using an AID converter. The resolution of the sample is about 30${\mu}{\textrm}{m}$, which corresponds to the theoretical resolution. Also, the cross-sectional images of onion cells were measured in real time scheme.

Performance Characteristics of MicroPET R4 Scanner for Small Animal Imaging (소동물 영상을 위한 MicroPET R4스캐너의 특성평가)

  • Lee, Byeong-Il;Lee, Jae-Sung;Kim, Jin-Su;Lee, Dong-Soo;Choi, Chang-Un;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Purpose: Dedicated animal PET is useful equipment for the study of new PET tracer. recently, microPET R4 was installed in the Korea institute of radiology and medical science. In this study, we measured the characteristics of scanner. Materials and methods: Resolution was measured using a line source (F-18:65 ${\mu}Ci$, inner diameter: 0.5 mm). The line source was put in the axial direction and was moved from the center of field of view to outside with 1 mm interval. PET images were reconstructed using a filtered back-protection and ordered subset expectation maximization. line source (16.5 ${\mu}Ci$, 78 mm) was put on the tenter of axial direction to measure the sensitivity when the deadtime was under 1%. Images were acquired during 4 minutes respectively from center to 39 mm outward. Delayed count was subtracted from total count and then decay was corrected for the calculation of sensitivity. Noise equivalent count ratio and scatter fraction were calculated using cylindrical phantom. Results: Spatial resolution of reconstructed image using filtered back-projection was 1.86 mm(radial), 1.95 mm(tangential), 1.95 mm(axial) in the tenter of field of view, and 2.54 mm, 2.8 mm, 1.61 mm in 2 cm away from the center respectively. Sensitivity was 2.36% at the center of transaxial field of view. Scatter fraction was 20%. Maximal noise equivalent count ratio was 66.4 kcps at 242 kBq/mL. Small animal images were acquired for confirmation of performance. Conclusion: Performance characteristics of microPET R4 were similar with reported value. So this will be a useful tool for small animal imaging.

Classification of Upper Body Somatotypes according to the Age Group : Using 3D-Body Scan Data

  • Na, Hyun-Shin
    • International Journal of Costume and Fashion
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 2005
  • Two hundreds of female aged 19 years old and up were recruited to evaluate the postural changes and bilateral variation of asymmetry over age. To find out the differences among the age group, subjects were classified into 5 groups, early young age(19-29), late young age(30-39), early middle age(40-49), late middle age(50-59), and old age(60-). 35 body measurements were taken by the 3-D body scanner which allowed us to take measurements which cannot be measured using traditional methods, including the shape of a cross section, slice area surface are, and volume. Bilateral variations were observed as a function of age; Depth of scapular point level, scapular point to center back, and blade angle. Postural change of anterior cervical angle, upper anterior thoracic angle, upper posterior thoracic angle, posterior cervical angle, and center back/center front ratio were also exhibited. In each measurements, subjects were classified into normal, and abnormal group. Percentiles of abnormal in shoulder line angle, blade angle, neck point $\∼$ acromial point $\∼$ scapular point, posterior cervical angle, and upper posterior thoracic angle were increased over age group. The upper body of lateral view was classified into 3 types of posture based on the previous research; straight, erect(leaning back), and stooped(bent forward). The percentiles of subjects who have straight postures were decreased as a function of age, but those of stooped postures were increased. Subjects who have erect postures did not so. The stooped posture group shows the big cervical fossa angle, anterior cervical angle, posterior cervical angle, upper posterior thoracic angle, and the small upper anterior thoracic angle comparing to the straight and erect posture group. These results could be apply for clothing construction reflecting the changes in back, shoulder, neck, and the bilateral asymmetry according to the target age group.

An Assessment of Image Analysis of Longitudinal Bone Changes (시간경과에 따른 골변화의 영상 분석에 관한 연구)

  • Kim Young-Jin;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.73-86
    • /
    • 1997
  • This study was performed to assess the analyzing methods developed to detect clinically and quantitatively longitudinal bone changes. Through preliminary experiment, accuracy of Cu-Eq value conversion to the mass of HA was examined. For main experiment, 15 intraoral radiograms taken at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture in extracted sites of 3 cases were used. We took the radiograms with copper step wedge as test object and HA phantom X -ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner into computer were digitized and analyzed by NIH image program. The stability of the copper equivalent transformation and the usefulness of two analyzing methods by ROI and Reslice were examined. Obtained results as follows: 1) On the Cu equivalent images, the coefficient of variation in the measurement of Cu-Eq. value of ROI ranged from 0.05 to 0.24 and showed high reproducibility. 2) All results obtained by resliced contiguous image were coincident with those obtained from the assessment by ROI and formation of plot profile. 3) On the stacked and resliced image at the line of interest, we could analyze directly and quantitatively the longitudinal changes at several portions by plot profile and qualitatively by surface plot. 4) Implant area showed marked resorption till 2 weeks after implantation and showed significant increase in Cu-Eq. value at 6th week(p<0.01) and periapical area showed increase in Cu-Eq. value at 6th week compared to after-operation's.

  • PDF