• 제목/요약/키워드: Line Scanning Analysis

검색결과 129건 처리시간 0.027초

화상처리기법을 이용한 변형율해석에 관한 연구 (A Study on the Strain Analysis by Image Processing Technique)

  • 백인환;신문교
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.32-45
    • /
    • 1988
  • The scanning moire method, in which the master grating is replaced by the scanning line of television camera and in which the moire pattern is obtained by thining out some scanning line, is discussed by the sampling theory. It is determined also by the sampling theory that relationship between the fringe pattern. The programs that analyze the strain by the scanning moire method have been developed. For the simulation model in which we are able to calculate analytically the distribution of strains, the scanning moire method is discussed. It is shown that the small strains and the large strains are analyzed from the same picture by the thinning out technique and that the accuracy of analysis is improved by change of the phase in the thinning out technique.

  • PDF

초고속 OCT응용을 위한 위상변조 광지연단 (Phase Modulation Optical Delay Line for Ultrafast OCT Application)

  • 황대석;이영우
    • 한국정보통신학회논문지
    • /
    • 제9권4호
    • /
    • pp.861-864
    • /
    • 2005
  • 광위상변조기를 이용하여 OCT용 초고속 광지연단을 설계하고 수치해석을 수행하였다. 수치해석은 electro-optic 위상 변조기에 1310nm, 10ps의 펄스폭을 갖는 레이저 광원을 적용하여 수행하였다. 수치해석결과로 500MHz의 변조 주파수일때 19ps의 시간 지연을 얻었으며, 이는 기존의 기계적 검출 방식(수십kHz)의 OCT장치에 비해 1000배이상 빠른 검출이 가능할 것으로 예상된다.

강판 종별 온도에 따른 산화 민감도 조사 (Investigation of Oxidation Sensitivity with Temperature of Steel Plate Type)

  • 김주한;이기만
    • 한국수소및신에너지학회논문집
    • /
    • 제30권5호
    • /
    • pp.455-464
    • /
    • 2019
  • Experiments were conducted to investigate the sensitivity of steel plate oxidation with temperature in a simulated furnace. Used steel plates were a general steel and a high tensile steel. Porous media burner (PM burner) used in model furnace was made for uniform temperature profile. The surrounding temperature was controlled by adjusting the flow rate of the mixture in the combustor. Oxide layer analysis was performed using SEM image analysis and EDS line scanning. Both steel sheets showed a tendency to increase the thickness of the steel sheet surface oxide layer as the temperature increases, and it was confirmed that the flaking phenomenon in surface oxidation layer appeared when the temperature was above a certain temperature.

모드형상분석을 위한 연속 스캐닝 레이저 도플러 진동측정기 (A Continuous Scanning Laser Doppler Vibrometer for Mode Shape Analysis)

  • 박기환;최지은;라종필;왕세명;경용수;김경석
    • 대한기계학회논문집A
    • /
    • 제27권5호
    • /
    • pp.734-741
    • /
    • 2003
  • This paper addresses the vibration mode shape Measurement technique utilizing a Continuous Scanning Laser Doppler Vibrometer (CSLDV). The continuous scanning capability is added to the conventional discrete Laser Doppler Vibrometer by reflecting the laser beams on the surface of the object using two oscillating mirrors. The bow scanning resulted from the proposed scanning method is eliminated by feedback control. The velocity output signal from the CSLDV is modulated to give the spatial velocity distribution in terms of coefficients which are obtained from the Fast Fourier Transformation of the time dependent velocity signal. Using the Chebyshev series from, the analysis of the vibration mode shape techniques for straight line scanning and 2 dimensional scanning are presented and discussed. The performance of the proposed SLDV is presented using the experimental results of the vibration mode shape of a cantilever and plate

Initial Experience of Patient-Specific QA for Wobbling and Line-Scanning Proton Therapy at Samsung Medical Center

  • Jo, Kwanghyun;Ahn, Sung Hwan;Chung, Kwangzoo;Cho, Sungkoo;Shin, Eun Hyuk;Park, Seyjoon;Hong, Chae-Seon;Kim, Dae-Hyun;Lee, Boram;Lee, Woojin;Choi, Doo Ho;Lim, Do Hoon;Pyo, Hong Ryull;Han, Youngyih
    • 한국의학물리학회지:의학물리
    • /
    • 제30권1호
    • /
    • pp.14-21
    • /
    • 2019
  • Purpose: To report the initial experience of patient-specific quality assurance (pQA) for the wobbling and line-scanning proton therapy at Samsung Medical Center. Materials and Methods: The pQA results of 89 wobbling treatments with 227 fields and 44 line-scanning treatments with 118 fields were analyzed from December 2015 to June 2016. For the wobbling method, proton range and spread-out Bragg peak (SOBP) width were verified. For the line-scanning method, output and two-dimensional dose distribution at multiple depths were verified by gamma analysis with 3%/3 mm criterion. Results: The average range difference was -0.44 mm with a standard deviation (SD) of 1.64 mm and 0.1 mm with an SD of 0.53 mm for the small and middle wobbling radii, respectively. For the line-scanning method, the output difference was within ${\pm}3%$. The gamma passing rates were over 95% with 3%/3 mm criterion for all depths. Conclusions: For the wobbling method, proton range and SOBP width were within the tolerance levels. For the line-scanning method, the output and two-dimensional dose distribution showed excellent agreement with the treatment plans.

자동 감마 증류탑 검사 장치를 위한 방사선 계측장치 설계 (Design of radiation detection circuit for gamma column scanning)

  • 김종범;정성희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.612-615
    • /
    • 2003
  • In this paper, a design of radiation detector for gamma column scanner is introduced. Distillation column is important unit in Petro-chemical industries, and its on-line diagnose is very important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose as gamma scanning. For this purpose radiation detection circuit, radiation source and mechanical system for moving source and detector are required. Conventional radiation detection circuit for this application is sensitive to electric noise because of interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using loop coil instead of slip ring to remove contact noise. Radiation detection system designed here for gamma scanning consist of BGO detector, high voltage circuit, PHA circuit and FSK modem. The BGO detector is used as radiation sensor, high voltage circuit and peak height analysis circuit is essential to process the signal generated from BGO detector. Micro controller convert measured data into ASCII data. FSK modem transmit ASCII data. Transmitted ASCH data is picked up in antenna coil and processed for combined function with mechanical system. This method gives good result by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  • PDF

반도성 ZnO 세라믹 입계에서 Si 원자 거동에 따른 열화기구 (The Degradation Mechanism with Si Atom's Behaviors in the Grainboundary of Semiconducting ZnO Ceramics)

  • 소순진;김영진;김응권;송민종;박춘배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.25-28
    • /
    • 2001
  • The objectives of this paper are to demonstrate the electrical degradation phenomena with Si atom's behaviors in the grainboundary of semiconducting ZnO ceramics. The ZnO ceramic devices used in this investigation were fabricated by standard ceramic techniques. Especially, $SiO_2$ were added to analyze the degradation characteristics with Si and sintered in oxygen ambient at $1300^{\circ}C$. The conditions of DC degradation test were $115{\pm}2^{\circ}C$ for 13h. Using XRD and SEM, the phase and microstructure of samples were analyzed respectively. E-J analysis was used to determine $\alpha$. Frequency analysis was accomplished to understand $R_g$ and $R_b$ at the equivalent circuit. Electrical stability improved as the amount of $SiO_2$ addition increased. This results were explain by the quantitative analysis and the line scanning method of EPMA.

  • PDF

Development of Two-Dimensional Scanning Videokymography for Analysis of Vocal Fold Vibration

  • Wang, Soo-Geun;Lee, Byung-Joo;Lee, Jin-Choon;Lim, Yun-Sung;Park, Young Min;Park, Hee-June;Roh, Jung-Hoon;Jeon, Gye-Rok;Kwon, Soon-Bok;Shin, Bum-Joo
    • 대한후두음성언어의학회지
    • /
    • 제24권2호
    • /
    • pp.107-111
    • /
    • 2013
  • Objectives : We developed two-dimensional (2D) scanning videokyomography to evaluate the mucosal wave of whole vocal cords in real time to overcome the limit of preexisting stroboscopy and line scanning videokymography which could not evaluate it. Methods : We implemented a continuous light source with high brightness, a high-definition CMOS camera, and capture board for saving the data. We created the software program to analyze the image data from the system. The test of the functionality of the 2D scanning videokymography camera was performed in one of the authors (P.H.J 32 years old male). Vocal cord images were obtained during normal phonation and falsetto phonation. Images were obtained also during cough, diplophonia. Results : The system made it possible to measure objective parameters, including fundamental frequency, amplitude, regularity, mucosal wave, and phase difference, medial and lateral peak, opening versus closing duration related to vocal fold vibration. Simultaneously, it enabled analysis of the whole mucosal wave of the entire vocal fold in real time. 2D scanning videokymography was also effective for evaluating the dynamic status of the vocal fold when the subject phonated aperiodic voice. Conclusion : In conclusion, 2D scanning videokymography can support the analysis of the whole mucosal wave of the entire vocal cord with objective vocal parameters, overcoming the limitations of stroboscopy and previous line scanning videokymography techniques.

  • PDF

저온 주사 레이저 및 홀소자 현미경을 이용한 GdBCO와 YBCO 초전도 선재의 국소적 특성 분석 (Analysis of the Local Properties in GdBCO and YBCO Coated Conductors using Low-temperature Scanning Laser and Hall Probe Microscopy)

  • 박상국;이형철
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.169-177
    • /
    • 2012
  • Distribution of the local properties in GdBCO and YBCO coated conductors was investigated using Low-temperature Scanning Laser and Hall Probe Microscopy (LTSLHPM). We prepared GdBCO and YBCO coated conductors to study the spatial distribution of the current density in a single bridge. Inhomogeneity of the ${T_c}^{max}$ in the bridge was analyzed from experimental results of Scanning Laser Microscopy (SLM) near the superconducting transition. The local transport and screening current in the bridge were also investigated using Scanning Hall Probe Microscopy (SHPM). A series of line scans of SLM of the GdBCO and YBCO sample showed that lines with more inhomogeneous distributions of ${\delta}V$ had more inhomogeneous distributions of ${T_c}^{max}$. The defect of the superconducting layer of the GdBCO sample caused by damage to the substrate affected the current flow. And we could analyze the redistribution of the current density using SLM and SHPM.

Wavelet Analysis to Real-Time Fabric Defects Detection in Weaving processes

  • Kim, Sung-Shin;Bae, Hyeon;Jung, Jae-Ryong;Vachtsevanos, George J.
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제2권1호
    • /
    • pp.89-93
    • /
    • 2002
  • This paper introduces a vision-based on-line fabric inspection methodology of woven textile fabrics. Current procedure for determination of fabric defects in the textile industry is performed by human in the off-line stage. The advantage of the on-line inspection system is not only defect detection and identification, but also 벼ality improvement by a feedback control loop to adjust set-points. The proposed inspection system consists of hardware and software components. The hardware components consist of CCD array cameras, a frame grabber and appropriate illumination. The software routines capitalize upon vertical and horizontal scanning algorithms characteristic of a particular deflect. The signal to noise ratio (SNR) calculation based on the results of the wavelet transform is performed to measure any deflects. The defect declaration is carried out employing SNR and scanning methods. Test results from different types of defect and different style of fabric demonstrate the effectiveness of the proposed inspection system.