• Title/Summary/Keyword: Limit Error

Search Result 554, Processing Time 0.026 seconds

A Study on the Incident Angle Estimation Method of Target at Coherent Interference (상관성 간섭에서 표적의 입사각 추정 방법에 대한 연구)

  • Shin, Ho-Sub
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.5
    • /
    • pp.75-81
    • /
    • 2010
  • Adaptive array antenna system estimates target signal, as making a null pattern toward the interference signal. However, receiving a coherent interference signal at adaptive array antenna system, as target signal is regarded as interference signal, the performance of system rapidly decreases. The main beam does not direct an incidence direction of target signal due to sensitivity in directivity error. This paper proposes beamforming algorithm which combines high order limit condition and directivity error modify method. And it minimizes degree of freedom and decreases interference signal and directivity error using proposed algorithm. This paper compares and analyzes the performance of proposed algorithm and general algorithm using simulation. In this paper, the proposed algorithm correctly estimates an incident angle, but general algorithm occurs an error of about $0.8^{\circ}$.

A Dynamic Offset and Delay Differential Assembly Method for OBS Network

  • Sui Zhicheng;Xiao Shilin;Zeng Qingji
    • Journal of Communications and Networks
    • /
    • v.8 no.2
    • /
    • pp.234-240
    • /
    • 2006
  • We study the dynamic burst assembly based on traffic prediction and offset and delay differentiation in optical burst switching network. To improve existing burst assembly mechanism and build an adaptive flexible optical burst switching network, an approach called quality of service (QoS) based adaptive dynamic assembly (QADA) is proposed in this paper. QADA method takes into account current arrival traffic in prediction time adequately and performs adaptive dynamic assembly in limited burst assembly time (BAT) range. By the simulation of burst length error, the QADA method is proved better than the existing method and can achieve the small enough predictive error for real scenarios. Then the different dynamic ranges of BAT for four traffic classes are introduced to make delay differentiation. According to the limitation of BAT range, the burst assembly is classified into one-dimension limit and two-dimension limit. We draw a comparison between one-dimension and two-dimension limit with different prediction time under QoS based offset time and find that the one-dimensional approach offers better network performance, while the two-dimensional approach provides strict inter-class differentiation. Furthermore, the final simulation results in our network condition show that QADA can execute adaptive flexible burst assembly with dynamic BAT and achieve a latency reduction, delay fairness, and offset time QoS guarantee for different traffic classes.

Retransmission with Transmission Quantity Allocation for Energy Harvesting Wireless Sensor Networks

  • Gun-Hee Kim;Ikjune Yoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.6
    • /
    • pp.175-182
    • /
    • 2024
  • In wireless sensor networks, batteries limit lifespan, and heavy data transmission around the sink causes the hotspot problem. To address this, data collection amounts are allocated to child nodes to limit transmission. However, this approach has issues with nodes far from the sink having excessive energy and failing to transmit the allocated amount due to data transmission errors. This paper proposes a method to prevent sensor data loss through error recovery via retransmission. The method ensures that each node's retransmission volume stays within its allocated data amount and energy limits, using excess energy for error recovery. Simulations show that this technique effectively recovers data transmission errors, collects data, minimizes energy depletion around the sink, and increases data collection rates.

Improved block-wise MET for estimating vibration fields from the sensor

  • Jung, Byung Kyoo;Jeong, Weui Bong;Cho, Jinrae
    • Structural Engineering and Mechanics
    • /
    • v.64 no.3
    • /
    • pp.279-285
    • /
    • 2017
  • Modal expansion technique (MET) is a method to estimate the vibration fields of flexible structures by using eigenmodes of the structure and the signals of sensors. It is the useful method to estimate the vibration fields but has the truncation error since it only uses the limit number of the eigenmodes in the frequency of interest. Even though block-wise MET performed frequency block by block with different valid eigenmodes was developed, it still has the truncation error due to the absence of other eigenmodes. Thus, this paper suggested an improved block-wise modal expansion technique. The technique recovers the truncation errors in one frequency block by utilizing other eigenmodes existed in the other frequency blocks. It was applied for estimating the vibration fields of a cylindrical shell. The estimated results were compared to the vibration fields of the forced vibration analysis by using two indices: the root mean square error and parallelism between two vectors. These indices showed that the estimated vibration fields of the improved block-wise MET more accurately than those of the established METs. Especially, this method was outstanding for frequencies near the natural frequency of the highest eigenmode of each block. In other words, the suggested technique can estimate vibration fields more accurately by recovering the truncation errors of the established METs.

Adaptive mesh refinement for 3-D hexahedral element mesh by iterative inserting zero-thickness element layers (무두께 요소층을 이용한 육면체 격자의 반복적 적응 격자 세분)

  • Park C. H.;Yang D. Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.79-82
    • /
    • 2004
  • In this study, a new refinement technique for 3-dimensional hexahedral element mesh is proposed, which is aimed at the control of mesh density. With the proposed scheme the mesh is refined adaptively to the elemental error which is estimated by 'a posteriori' error estimator based on the energy norm. A desired accuracy of an analysis i.e. a limit of error defines the new desired mesh density map on the current mesh. To obtain the desired mesh density, the refinement procedure is repeated iteratively until no more elements to be refined exist. In the algorithm, at first the regions of mesh to be refined are defined and, then, the zero-thickness element layers are inserted into the interfaces between the regions. All the meshes in the regions, in which the zero-thickness layers are inserted, are to be regularized in order to improve the shape of the slender elements on the interfaces. This algorithm is tested on a simple shape of 2-d quadrilateral element mesh and 3-d hexahedral element mesh. A numerical example of elastic deformation of a plate with a hole shows the effectiveness of the proposed refinement scheme.

  • PDF

Track-following Control for Disk Surface Defect of Optical Disk Drive Systems. (광디스크 드라이브의 디스크 표면 결함에 대한 트래킹 제어)

  • Lee, Joon-Seong;Jeong, Dong-Seul;Chung, Chung-Choo
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.223-228
    • /
    • 2005
  • In oprical disk drives, surface defects on a disk distort tracking error signal and disturb a precision tracking control.. A conventional method against disk defect is held the tracking control signal when a defective portion is detected. However, if the defective portion is getting longer, objective lens will get away from following track. In order to keep the postion of spot from following track, the servo system must predict tracking error and control the object lens in the defective portion. A tracking control system for optical disk drives was proposed recently based on both Coprime Factorization(CF) and Zero Phase Erro. Tracking(ZPET) control. The system was proposed for overcome the limit of previously tracking error. But there were no research about the method against the defective portion. This paper proposes a new and simple ZPET construct. as a new method against the defective portion. From experimental results, we have proved that proposed method improves the performance against the defective portion, decreases the uncertainty of a model, and requires less memory than the previously proposed method.

  • PDF

Volatility analysis and Prediction Based on ARMA-GARCH-typeModels: Evidence from the Chinese Gold Futures Market (ARMA-GARCH 모형에 의한 중국 금 선물 시장 가격 변동에 대한 분석 및 예측)

  • Meng-Hua Li;Sok-Tae Kim
    • Korea Trade Review
    • /
    • v.47 no.3
    • /
    • pp.211-232
    • /
    • 2022
  • Due to the impact of the public health event COVID-19 epidemic, the Chinese futures market showed "Black Swan". This has brought the unpredictable into the economic environment with many commodities falling by the daily limit, while gold performed well and closed in the sunshine(Yan-Li and Rui Qian-Wang, 2020). Volatility is integral part of financial market. As an emerging market and a special precious metal, it is important to forecast return of gold futures price. This study selected data of the SHFE gold futures returns and conducted an empirical analysis based on the generalised autoregressive conditional heteroskedasticity (GARCH)-type model. Comparing the statistics of AIC, SC and H-QC, ARMA (12,9) model was selected as the best model. But serial correlation in the squared returns suggests conditional heteroskedasticity. Next part we established the autoregressive moving average ARMA-GARCH-type model to analysis whether Volatility Clustering and the leverage effect exist in the Chinese gold futures market. we consider three different distributions of innovation to explain fat-tailed features of financial returns. Additionally, the error degree and prediction results of different models were evaluated in terms of mean squared error (MSE), mean absolute error (MAE), Theil inequality coefficient(TIC) and root mean-squared error (RMSE). The results show that the ARMA(12,9)-TGARCH(2,2) model under Student's t-distribution outperforms other models when predicting the Chinese gold futures return series.

Detection Limit of a NaI(Tl) Survey Meter to Measure 131I Accumulation in Thyroid Glands of Children after a Nuclear Power Plant Accident

  • Takahiro Kitajima;Michiaki Kai
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.3
    • /
    • pp.131-143
    • /
    • 2023
  • Background: This study examined the detection limit of thyroid screening monitoring conducted at the time of the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident in 2011 using a Monte Carlo simulation. Materials and Methods: We calculated the detection limit of a NaI(Tl) survey meter to measure 131I accumulation in the thyroid gland of children. Mathematical phantoms of 1- and 5-year-old children were developed in the simulation of the Particle and Heavy Ion Transport code System code. Contamination of the body surface with eight radionuclides found after the FDNPP accident was assumed to have been deposited on the neck and shoulder area. Results and Discussion: The detection limit was calculated as a function of ambient dose rate. In the case of 40 Bq/cm2 contamination on the body surface of the neck, the present simulations showed that residual thyroid radioactivity corresponding to thyroid dose of 100 mSv can be detected within 21 days after intake at the ambient dose rate of 0.2 µSv/hr and within 11 days in the case of 2.0 µSv/hr. When a time constant of 10 seconds was used at the dose rate of 0.2 µSv/hr, the estimated survey meter output error was 5%. Evaluation of the effect of individual differences in the location of the thyroid gland confirmed that the measured value would decrease by approximately 6% for a height difference of ±1 cm and increase by approximately 65% for a depth of 1 cm. Conclusion: In the event of a nuclear disaster, simple measurements carried out using a NaI(Tl) scintillation survey meter remain effective for assessing 131I intake. However, it should be noted that the presence of short-half-life radioactive materials on the body surface affects the detection limit.

The NAND Type Flash EEPROM Using the Scaled SONOSFET (Scaled SONOSFET를 이용한 NAND형 Flash EEPROM)

  • 김주연;권준오;김병철;서광열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.145-150
    • /
    • 1998
  • 8$\times$8 bit scaled SONOSFET NAND type flash EEPROM that shows better characteristics on cell density and endurance than NOR type have been designed and its electrical characteristics are verified with computer aided simulation. For the simulation, the spice model parameter was extracted from the sealed down SONOSFET that was fabricated by $1.5mutextrm{m}$ topological design rule. To improve the endurance of the device, the EEPROM design to have modified Fowler-Nordheim tunneling through the whole channel area in Write/Erase operation. As a result, it operates Write/Erase operation at low current, and has been proven Its good endurance. The NAND type flash EEPROM, which has upper limit of V$_{th}$, has the upper limit of V$_{th}$ as 4.5V. It is better than that of floating gate as 4V. And a EEPROM using the SONOSFET without scaling (65$\AA$-l65$\AA$-35$\AA$), was also designed and its characteristics have been compared. It has more possibliity of error from the V$_{th}$ upper limit as 4V, and takes more time for Read operation due to low current. As a consequence, it is proven that scaled down SONOSFET is more pertinent than existing floating gate or SONOSFET without scaling for the NAND type flash EEPROM.EPROM.

  • PDF

The Accuracy of Prescriptions Using a Computerized Chemotherapy Order System (항암화학요법 처방전산 시스템에 의한 처방 정확도에 관한 연구)

  • Kim, Jung-Tae;Lee, Jae-Hwan;Shin, Hyun-Taek
    • Korean Journal of Clinical Pharmacy
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • A computerized chemotherapy order system (CCOS) was developed to improve the accuracy and efficiency of prescriptions for pharmacy medication scheduling at a teaching hospital, Asan Medical Center, Seoul, Korea. We evaluated the system by comparing prescriptions before and after the implementation of the system and by analyzing the effects of the system on dosing accuracy (only against 5-FU), prescription change, overdoses above maximum limit and medication disposal in non computerized program group (control group) and CCOS group. In terms of dosing accuracy, prescription error rate (%) was significantly decreased in CCOS groups compared with the control group. The rate of prescription changes was also significantly decreased in CCOS groups. Regarding overdoses above maximum limit, we found that there was no prescription order exceeding the dosage limit in CCOS groups in contrast to significant overdoses in control group. In terms of medication disposal, there was no significant difference between 2 groups. We suggest that the computerized chemotherapy order system for chemotherapy may bean important and useful tool for minimizing prescribing errors in the hospitals.

  • PDF