• Title/Summary/Keyword: Lightweight concrete

Search Result 619, Processing Time 0.027 seconds

기포제 관점에서 경량기포 콘크리트의 개선방향에 관한 문헌적 연구 (Literature study on the improvement of lightweight concrete in perspective of foaming agent)

  • 최명인;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.141-142
    • /
    • 2015
  • This literature study is focused on the improvement of lightweight concrete in perspective of foaming agent. Lightweight concrete is the cured concrete as putting required amount of foaming agent to slurry which is a mixture of a certain amount of cement, sand, and water. It has lower density than general concrete, because foaming agent disintegrates numerous bubbles evenly and independently. Thus, it is capable of lightening the weight and great for sound absorption and insulation, In foreign countries, studies for structural lightweight concrete mainly of tunnel grouting and weight lightening of heavy structures are going along actively. Domestically, exterior panel and ALC blocks are alternatively used for flooring. Therefore, this research consider improvement of lightweight concrete in perspective of foaming agent with foundation study.

  • PDF

초기재령에서 보통골재 및 경량골재 콘크리트의 시간경과에 따른 초음파 속도 변화 (Ultrasonic Pulse Velocity of Normal Aggregate Concrete and Lightweight Aggregate Concrete at Early age According to Elapsed Time)

  • 김원창;최형길;남정수;김규용;이태규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.61-62
    • /
    • 2021
  • Because of the problem of increasing self-weight due to the enlargement and high-rise of buildings using normal aggregate concrete, the need for structural lightweight aggregate concrete increases. However, early strength prediction is required when placing structural lightweight aggregate concrete, but research is insufficient. In this study, the ultrasonic pulse velocity of normal aggregate concrete and lightweight aggregate concrete was measured at early age. As a result, the ultrasonic pulse velocity of lightweight aggregate concrete was lower than normal aggregate concrete according to elapsed time at early age.

  • PDF

폴리머 개질 경량콘크리트 일방향 부재의 휨 거동에 관한 실험적 연구 (Experimental Investigation of the Flexural Behavior of Polymer-modified Lightweight Aggregate Concrete One-Way Members)

  • 변은혁;김민숙;이영학;김희철
    • 한국전산구조공학회논문집
    • /
    • 제23권5호
    • /
    • pp.551-557
    • /
    • 2010
  • 본 연구는 경량콘크리트와 폴리머 개질 경량콘크리트 보에 있어 현행 최소허용철근변형률 기준의 타당성과 최외단 철근의 순인장 변형률에 따른 휨 거동 및 휨 성능을 평가하는 것에 그 목적이 있다. 크기와 형상이 동일한 8개의 시험체를 제작하여 콘크리트의 종류와 최외단 철근의 순인장 변형률을 변수로 실험을 수행하였으며, 이를 통해 순인장 변형률에 따른 경량콘크리트 보와 폴리머 개질 경량콘크리트 보의 강도와 연성의 변화를 분석하였다. 실험 결과 경량콘크리트 보와 폴리머 개질 경량콘크리트 보 모두에서 최외단 철근의 순인장 변형률이 증가할수록 시험체의 연성이 증가하였으며, 특히 최외단 철근의 순인장 변형률 0.005이상에서 보통 중량 콘크리트와 유사한 연성지수를 확보할 수 있었다.

인공경량골재의 입도에 따른 고강도 경량콘크리트의 강도변화에 대한 실험적 연구 (An Experimental Study for the Strength Variations of High-strength Lightweight Concrete According to Grain-size of Artificial Lightweight Aggregate)

  • 김성칠;박기찬;최형욱
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권5호
    • /
    • pp.209-217
    • /
    • 2011
  • 최근 구조물들이 대형화됨으로써 보통 콘크리트를 사용할 경우 강도 및 내구성에 비하여 중량이 크다는 결점으로 인해 콘크리트 구조물의 설계 및 시공의 안정에 제약을 주게 된다. 이러한 결점을 개선하기 위해서는 자중이 작고 강도가 큰 경량콘크리트가 요구되나, 국내에서는 실용화를 위한 연구가 아직 미비한 실정에 있다. 일반적으로 고온에서 소성시켜 제조된 인공골재는 골재가 팽창되어 내부에 무수한 기포를 가지게 된다. 따라서 골재의 크기에 따라 이들의 기포가 경량콘크리트 비중과 강도에 미치는 영향 연구가 필요하다. 본 연구에서는 국내에서 개발된 화력발전소 폐기물과 점토를 고온에서 소성, 팽창시켜 만든 인공경량골재의 입도별 배합설계를 실시하고 실험을 통하여 경량콘크리트의 비중 및 강도변화를 비교 고찰했다. 또한 경량콘크리트의 고강도 발현을 위한 인공경량골재의 최적 입도비를 제안하였다.

경량골재의 입도 변화에 따른 경량콘크리트의 물리적 특성 (Physical Properties of Lightweight Concrete by Grain Size of Lightweight Aggregate)

  • 이수형;권춘우;공태웅;이한백
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.255-256
    • /
    • 2010
  • 콘크리트의 자중 과대라는 문제점을 해결하기 위해 중국경량골재의 경량콘크리트에 대한 적용성을 입도별로 검토하여 중국경량골재의 효율적인 활용을 위한 참고자료로 제시하고자 한다.

  • PDF

Failure of lightweight aggregate concrete-filled steel tubular columns

  • Ghannam, Shehdeh;Jawad, Yahia Abdel;Hunaiti, Yasser
    • Steel and Composite Structures
    • /
    • 제4권1호
    • /
    • pp.1-8
    • /
    • 2004
  • Tests on steel tubular columns of square, rectangular and circular section filled with normal and lightweight aggregate concrete were conducted to investigate the failure modes of such composite columns. Thirty-six full scale columns filled with lightweight and normal weight aggregate concrete, eighteen specimens for each, were tested under axial loads. Nine hollow steel sections of similar specimens were also tested and results were compared to those of filled sections. The test results were illustrated by a number of load-deflection and axial deformation curves. The results showed that both types of filled columns failed due to overall buckling, while hollow steel columns failed due to bulging at their ends (local buckling). According to the above-mentioned results, and due to low specific gravity and thermal conductivity of the lightweight concrete the further interest should be concentrated in replacing the normal concrete by the lightweight aggregate concrete.

광물성 기포제를 이용한 경량기포콘크리트의 물리적성질에 관한 실험적 연구 (A Experimental Study on the Physical properties of Lightweight Foamed Concrete Using Mineral Foam Agent)

  • 유제준;이한승;배규웅;이상섭;연규봉
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.49-52
    • /
    • 2003
  • The objective of this study the mechanical characteristics of prefoamed lightweight foamed concrete using the mineral foam agent which has high lightness, and strength. The compressive strength of lightweight foamed concrete using mineral foam agent are about 2 times degree high those the of lightweight foamed concrete using vegetable foam agent. Lightweight foamed concrete was able to obtain the result of 50kg/㎠ or more compressive strength, when was unit weight 0.8t/㎡. In the case of the same unit weight of concrete, it is influenced by w/c of foam agent ratio. The paper present extensive data on characteristics of compressive strength of the concrete manufatured with the different factors in mix design and also present optimum mix proportion.

  • PDF

광물성 기포제를 이용한 경량기포콘크리트의 물리적성질에 관한 실험적 연구 (A Experimental Study on the Physical properties of Lightweight Foamed Concrete Using Mineral Foam Agent)

  • 유제준;이한승;배규웅;이상섭;연규봉
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.49.1-52
    • /
    • 2003
  • The objective of this study the mechanical characteristics of preformed lightweight foamed concrete using the mineral foam agent which has high lightness, and strength. The compressive strength of lightweight foamed concrete using mineral foam agent are about 2 times degree high those the of lightweight foamed concrete using vegetable foam agent. Lightweight foamed concrete was able to obtain the result of 50kg/$\textrm{m}^3$ or more compressive strength, when was unit weight 0.8t/$\textrm{m}^3$. In the can of the same unit weight of concrete, it is influenced by w/c of loan agent ratio. The paper present extensive data on characteristics of compressive strength of the concrete manufactured with the different factors in mix design and also present optimum mix proportion.

  • PDF

덱크플레이트를 사용한 경량콘크리트 슬래브와 철골보의 합성보에서 쉬어코넥터의 내력에 관한 연구 (A Study on Strength of shear Connectors in Composite Beams of Steel and Lightweight Concrete Slabs with Deck Plate)

  • 김종식;박성무
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.293-298
    • /
    • 1995
  • The strength of shear connectors embedded in lightweight concrete slab with deck plate is influenced by various factors of deck plate, shear conncetor and concrete. Generally, it is reported that the strength of shear connector in lightweight concrete decreases in comparison with that in normal concrete. So this paper is to use compressive strength of lilghtweight concrete, width-height ratio of deck plate, and cross sectional area of shear conncetor as variables, to evaluate the strength of shear conncetors in composite beam of steel and lilghtweight concrete slabs with deck plate, and then to suggest the reasonable strength equation by comparing the push-out test results with establixhed strength formula. As the result of 24 specimens test, in case of lightweight concrete slab with deck plate, it has showed that in the same strength, the strength of shear connector decreased about 10~20% in comparison with that in normal concrete. In spite of lightweight concrete, the test results were closely approached the established strength formula of shear connector using Fisher's reduction coefficient.

  • PDF

경량콘크리트와 GFRP 보강근의 부착 특성 (Bond Characteristic Between Lightweight Concrete and GFRP Bar)

  • 손병락;김명식;김충호;장희석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권6호
    • /
    • pp.112-121
    • /
    • 2013
  • FRP 보강근을 사용한 경량콘크리트 구조체는 부식방지 및 자중감소의 효과를 동시에 기할 수 있는 이점이 있어서 추후 그 활용이 기대될 수 있다. 그러나 경량콘크리트와 FRP 보강근을 사용하여 보강근의 내부슬립 없이 외력에 저항할 수 있는 구조체를 만들기 위해서는 경량콘크리트와 FRP 보강근 사이의 부착특성을 파악하는 것이 대단히 중요하다. 그동안 보통콘크리트와 FRP 보강근 사이의 부착거동에 대하여는 많은 연구가 있어 왔으나 경량콘크리트와 FRP 보강근 사이의 부착거동에 대하여는 현재까지 연구결과가 대단히 부족한 실정이다. 따라서 본 연구에서는 경량콘크리트와 보강근 표면에 나선형태의 이형을 갖는 GFRP 보강근 사이의 부착특성을 조사하였다. 비교목적으로 보강근 종류, 콘크리트 종류, 경량콘크리트 강도종류의 실험변수를 고려하여 인발실험체들을 제작하고 실험을 행하였다. 실험분석 결과, 보통콘크리트와 철근을 사용한 실험체의 부착강도를 1.0으로 하였을 때 경량콘크리트와 나선형태의 이형을 갖는 GFRP 보강근을 사용한 실험체의 부착강도는 0.49로 나타났다.