• 제목/요약/키워드: Lightning protection

검색결과 252건 처리시간 0.028초

복합재 주익 무인항공기의 낙뢰보호 설계와 피격영역 해석 (Protection Design and Lightning Zone Analysis for Unmanned Aerial Vehicle with Composite Wings)

  • 우희채;김용태
    • 한국군사과학기술학회지
    • /
    • 제26권3호
    • /
    • pp.302-312
    • /
    • 2023
  • This paper describes the analysis of lightning strike zoning, the indirect lightning data simulation and the protection design for lightning indirect effects of equipment by lightning strike for unmanned aircraft consisting of composite wings. Through the analysis of lightning strike zoning according to the external shape of unmanned aerial vehicles, the structure areas that should be protected during lightning strike is derived, and the protection requirements of lightning indirect effects for flight critical equipments and equipment that must be operated upon lightning strike was derived. Lightning protection levels according to the location of mounting equipment and surrounding structure materials for each equipment was derived, and the protection design of the unmanned aerial vehicle with composite structures was also proposed from direct effect of lightning. Later, the lightning protection technology will be verified by the ground test of lightning direct and indirect effects.

일반형이 아닌 피뢰침의 설치 실태에 대한 통계적 조사 (Statistics on the Present Status of Installations of Non-conventional Lightning Rods)

  • 이복희;이석연;이수봉;백영환;이규선;김동성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.347-350
    • /
    • 2006
  • The conception of early streamers is in sufficient and inadequate as a parameter for the determination of any advantage of early streamer emission(ESE) lightning rods versus ordinary lightning rods. Thus, standards for many other national and international lightning protection as well as KS C IEC 61024-1 do not take ESE lightning rods, charge dissipation systems or non-conventional lightning rods. Unfortunately, many non-conventional lightning rods such as ESE lightning rods and charge dissipation systems in Korea are increasingly used in lightning protection of structures including explosive manufacturing buildings, electric generating, transmission and distribution systems. This study attempts to make aware of no advantage of ESE rods and other non-conventional lightning protection systems and to investigate the present status of installations of ESE lightning rods.

  • PDF

높이 20미터 미만인 구조물의 낙뢰리스크 평가 (Lightning Risk Assessment for Structures Lower than 20m High)

  • 이주철;김기현;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.21-27
    • /
    • 2012
  • Korean Industrial Standards for lightning protection system complies with IEC standards. However, the standards are applicable only to buildings and structures more than 20 meters in high. Therefore, it is necessary to determine whether lightning protection system should be installed on structures lower than 20 meters high. This paper proposes an efficient method of assessing risk against lightning of structures lower than 20 meters high. The method suggests simplified lightning protection system and provides selecting an appropriate protection level. The suggested method assumes that structure under assessment has no lightning protection system and there is no person around the structure at the moment of lightning stroke. A simplified method of assessing the risk to human within the structure is developed by adopting the general assessment factor. The selection of a protection level is possible by comparing tolerable risk with physical damage risk caused by a direct lightning. Finally, this paper gives ways to establish surge protection measures when a structure with lightning risk is within a radius of 2km from the assessed structure even if this structure requires no lightning protection system.

풍력발전기의 낙뢰피해 대책 검토 및 적용방안 (An Application Method and Review of Lightning Protection for Wind Turbines)

  • 한지훈;고경남;허종철
    • 동력기계공학회지
    • /
    • 제19권2호
    • /
    • pp.5-14
    • /
    • 2015
  • This investigation presents reviews of many research results on lightning damage to wind turbines and lightning protection strategies from IEC Standard, Europe, USA, Japan and Korea. There have been few studies on lightning protection of wind turbines in Korea, while various investigations have been performed in the other countries. It is necessary to apply some good lightning protection strategies of IEC Standard and the other countries to Korea. Those are as follows: The guideline for lightning protection of wind turbines should be established based on IEC Standards. It needs to be carried out both development of software and experimental studies for understanding the types of lightning damage to wind turbines and compiling the database. In order to minimize the lightning damage to wind turbines, it is a key factor for wind farm owners and researchers to provide the information about the damage cases and wind farm operation technique.

기생 인덕턴스를 고려한 항공기 탑재장비의 간접낙뢰 보호회로 설계 (Design of Lightning Induced Transient Protection Circuit for Avionics Equipment Considering Parasitic Inductance)

  • 심용기;조성진;김성훈;박준현;한종표
    • 한국항행학회논문지
    • /
    • 제21권5호
    • /
    • pp.459-465
    • /
    • 2017
  • 본 논문에서는 간접낙뢰로 인한 항공기 탑재 장비의 손상을 방지하기 위한 간접낙뢰 보호회로의 설계시 고려해야 하는 사항들을 설명한다. 낙뢰로부터 유도된 서지 전압은 항공기 전기 전자장비의 기능 장애나 손상을 가져오는데 이것을 낙뢰의 간접영향이라 한다. 이러한 항공기의 낙뢰 간접영향으로부터 항공전자 장비를 보호하기 위해서는 항공기에 가해진 낙뢰로 인한 영향성을 분석하고 이에 따른 보호 설계를 각각의 장비에 적용한다. 설계된 간접낙뢰 보호회로는 PCB와 TVS다이오드에 기생하는 인덕턴스로 인해 의도치 않은 결과를 가져올 수 있다. 본 논문에서는 간접낙뢰 보호회로를 구성하는 요소들에 기생하는 인덕턴스를 고려한 보호회로 설계 방법을 소개한다. 또한 설계된 보호회로의 유효성 확인을 위해 수행한 낙뢰 간접영향 검증시험 결과를 보인다.

Study on Enhancing Lightning Protection Scheme of Catenary in Subway Viaduct Section

  • Li, Rui-Fang;Chen, Kui;Chen, Li-Sheng;Cao, Xiao-Bin;Wu, Guang-Ning;Zhang, Xue-Qin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.950-958
    • /
    • 2017
  • Viaduct increases the height of subway catenary, namely magnifies lightning attraction scope that lead to higher possibility of suffering lightning stroke. Therefore, it is necessary to analyze performance of lightning striking to catenary of subway in viaduct section and propose an improving lightning protection scheme. In this paper, using ATP-EMTP simulation software to establish an associated model to evaluate lightning withstand level of catenary with existing lightning protection schemes including arrester and grounding point, an improving lightning protection scheme is proposed - every pillar ground earth and arresters are installed with some installing spacing between 200m to 400m based on lightning damage degree and reliability requirements - according to analyzing results: while lightning withstand level is lowest for lightning striking to the neutral pillar, lightning withstand level is greatest for lightning striking to the both-ends pillar that arrester and grounding point are both installed; grounding point could obviously improve lightning withstand level for lightning striking to ground wire while arrester could obviously improve the lightning withstand level for lightning striking to catenary; every pillar ground earth could enhance the lowest lightning withstanding level up to 2.5 times than of that pillar ground earth across every 200m.

건축물의 낙뢰보호를 위한 HEC(Hybrid ESE-Conductor) 방식에 관한 연구 (A Study on the HEC(Hybrid ESE-Conductor) Method for Lightning Protection of Buildings)

  • 김동진;김영선;이기식
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.146-152
    • /
    • 2008
  • The frequency of lightning is increased due to improbable weather condition and global wanning. This phenomenon increases economical damage as well as human damage. Advanced countries like europe and north america have applied the facility standard of lightning by accumulating a store of quantitative data about lightning research. Lightning facility is composed of the lightning accepting part for induction lightning, ground connected electrode which conducts lightning current. The lightning accepting part is composed of normal rod, horizontal conductor, ESE lightning rod. Moreover, lightning accepting part is taken to use by the method of protection. This paper suggests HEC(Hybrid ESE-Conductor) method which mixes horizontal conductor and ESE lightning rod. This is also discovered by experiment that the starting point of corona discharge current is low, so it is efficient for lightning protection comparing with other methods. Moreover, distribution of electric field is analyzed qualitatively by finite element method. It also results in the relation of the starting point of corona discharge current. Corona discharge current makes minute current about some ${\mu}A$ between the electrodes by the strength of electric field. Also it occurs insulation destruction of gas, and it is developed to the shape of streamer by increase of the strength of electric field. We can find that the initial occurrence of streamer and contact probability of lightning can have advantage after researching the starting point of corona discharge current and discharge current of lightning striking point. This research demonstrates that the suggested HEC method is economically competitive as a lightning protection facility, and it takes a capably perfect role.

A Novel Approved Mathematical Equation for Lightning Protection Angle

  • Singhasathein, Arnon;Rungseevijitprapa, Weerapun;Pruksanubal, Aphibal
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.1021-1029
    • /
    • 2018
  • During the past few decades, the lightning protection angle (${\alpha}$) has been proposed through several technical matters, namely graphical technique, numerical data and mathematical equation respectively. Nevertheless, these techniques are very complicated, and are difficult to utilize because they also contain several constraints practically. Hence, this paper proposes a novel equation of the lightning protection angle, which is a simple correlation, concise and easy to be implemented. Furthermore, the reliable result of this equation can confirm accuracy through comparative analysis with all previous techniques. As a result, these solutions are altogether equivalent. This novel equation can analyze the lightning protection angle of the vertical air termination system installed at the vertex of the royal pagoda in a Khema-pirataram temple which is at high risk due to lightning flashes.

철도신호설비용 낙뢰방호장치의 건설 (Construction of Lightning Protection System for Railway Signaling Equipments)

  • 최규형;서석철;최세완
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1193-1198
    • /
    • 2004
  • This paper describes the lightning protection system for railway signaling equipments installed at subway car depots in Seoul metropolitan Rapid Transit Cooperation. Several measures for improving lightning protection performance are adopted; newly organized grounding system for neutral line of power system, rolling method to minimize damages induced by direct lightning strike, new measures to reduce voltage differences between the signaling equipments and the ground, and improvement of grounding system. The proposed system has greatly reduced the grounding resistance and also the voltage difference between the signaling equipments and the ground, and has prevented the accident related with lightning surges since it was installed. The proposed approach can be viewed as a useful alternative of dealing with lightning protection for railway signaling equipments.

  • PDF

항공기 탑재 컴퓨터용 간접낙뢰 보호장치 개발 및 검증 (Development and Verification of Lightning Induced Transient Protection Device for Avionics Computer)

  • 심용기;안태식;박준현;한종표;양서희
    • 한국항행학회논문지
    • /
    • 제19권5호
    • /
    • pp.395-402
    • /
    • 2015
  • 본 논문에서는 간접낙뢰로 인한 항공기 탑재 컴퓨터의 손상을 보호하기 위한 간접낙뢰 보호장치의 설계 내용 및 시험 과정을 소개한다. 낙뢰로부터 유도된 서지 전압은 항공기 전기 전자장비의 기능 장애나 손상을 가져오는데 이것을 낙뢰의 간접영향이라 한다. 이러한 항공기의 낙뢰 간접영향으로부터 항공전자 장비를 보호하기 위해서는 항공기에 가해진 낙뢰로 인한 영향성을 분석하고 이에 따른 보호 설계를 각각의 장비에 적용한다. 본 논문에서는 보호대상 장비의 간접낙뢰로 인한 손상을 방지하기 위하여 수행한 RTCA DO-160G Section22의 카테고리 분석과 선정을 통한 간접낙뢰 수준 결정, 선정된 레벨에 따른 보호회로 설계 방법을 소개한다. 또한 설계된 보호회로의 유효성 확인을 위해 수행한 낙뢰 간접영향 검증시험 결과를 보인다.