• Title/Summary/Keyword: Lighting Pollution

Search Result 59, Processing Time 0.019 seconds

Light Pollution of Outdoor Lighting in Mokpo-si (건강한 야간환경 조성을 위한 목포시 옥외조명의 빛공해 평가)

  • Kong, Hyo Joo;Lee, Jin Seoung;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.45-50
    • /
    • 2009
  • Nowadays, the lighting of urban nightscape has become important for improvement in city. Lighting the outdoor is different that lighting an interior. Outdoor lighting designs should be designed to minimize glare, light trespass, light clutter and energy conservation to avoid light pollution. Mokpo city launched into a large scale project of the city beautification using outdoor lighting. However, outcomes of outdoor lighting project have faced strong opposition from environmental groups. This study aims to analyze the light pollution of outdoor lighting in Mokpo-si for creating a health night environment. The Radiant Imaging Prometric-1400 was used to measure the luminance of Yudal Mountain, Goha Island and Luminarie Street. The result showed that the all the outdoor lighting produce light pollution and some places like mountain and island did not need a lot of lighting all the time.

Analyze the Results of Lighting Type Change and Rroposal of Power Density per Unit Area for Light Pollution Control of Channel-letter Type Advertisement Lighting (채널레터형 광고조명의 빛공해 관리를 위한 조명방식 개선효과 분석 및 단위면적당 소비전력(W/㎡) 제한 방법 제안)

  • Yoo, Seongsik;Kim, Hyun-Ji;Kim, Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.759-766
    • /
    • 2018
  • Although the Act on the Prevention of Light Pollution Due to Artificial Lighting has been enforced since 2013, the area of advertisement lighting has made slow progress in solving the problems of light pollution. This paper first investigated institutional problems by analyzing domestic laws and regulations relating to the light pollution of advertisement lighting, and investigated and analyzed methods for reducing light pollution that were applied in overseas countries. Then, problems of light pollution were analyzed by conducting a research on the actual status of advertisement lightings installed in South Korea and applying various methods for reducing light pollution, and advertisement lighting using LED was recommended. As a method for reducing light pollution that can be applied to the process of manufacturing channel letter-type advertisement lights, power consumption per unit area ($W/m^2$) was proposed, and $100W/m^2$ was recommended as a value currently suitable for South Korea.

A Study on the Control Standards and an Environmental Lighting Zone-Setting method for Making Light Pollution Management (빛공해 방지를 위한 관리기준 및 조명환경관리구역 설정 방안에 관한 연구)

  • Kim, Ki-Tae;Oh, Min-Seok;Kim, Hway-Suh
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.27-33
    • /
    • 2011
  • This study aims to suggest some problems, which occur when environmental lighting zone is set by use-zone only, by comparing and analyzing the artificial illumination luminance. In addition, this study aims to review the control standards of light pollution and to suggest a practical environmental lighting zone-setting method. I checked out the standards of average surface luminance and luminance contrast as for light pollution management. In addition, I did some research on evaluation of light pollution on surroundings based on investigation of use-environment as for lighting environment setting method.

Calculation and Regulation Proposal of Light Pollution from Road Lightings (도로조명의 빛공해 계산 및 규제안 제안)

  • Cho, Sook-Hyun;Lee, Min-Wook;Choi, Hyeon-Seok;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.21-26
    • /
    • 2011
  • This is a study to establish regulations against light pollution for lighting on roads. Many kinds of light pollution by luminaire on roads was calculated and analyzed by applying the classification method of luminaires(Cut-off classification of IDA-IESNA, BUG Rating Classification) and the calculation method of Upward Lighting Ratio of CIE among measures to prevent light pollution that international lighting organizations suggest. As a result of the analysis, it was found that the regulation by Cutoff of IESNA and ULR classification of CIE could be one for scattered light of light pollution compared to BUG classification but is not sufficient for the regulation of light tresspass or glare. BUG classification by each lighting zone was suggested as threshold value of the light pollution regulation considering domestic conditions.

Effects of LED Lamps for Replacement of Metal Halide Lamp in Roadway Lighting Environment (LED램프와 메탈램프가 도로조명환경에 미치는 특성 비교평가)

  • Lee, Myung Gi;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.47-52
    • /
    • 2013
  • The problems of light pollution first became an issue in the 1970s when astronomers identified the degradation of the night sky due to the increase in lighting associated with development and growth. As more impacts to the environment by lighting have been identified, many attempts have been made for reducing light pollutions. To prevent light pollution and increase energy efficiency, Seoul Metropolitan Government(SMG) replaced metal halide road lighting to LED luminaire in four arterial highway in Seoul. The present study compared the lighting characteristics of metal halide and LED luminaire in terms of Korea Standard for road lighting(KS A 3701) and BUG rating from Illuminating Engineering Society of North America(IESNA). The results showed that LED luminaire increased road surface luminance up to 2 times in average compared to the metal halide environment. Also, LED luminaire reduced the glare value by 2 times and luminous flux over 50% than the metal halide luminaire. In comparison with the BUG ratings, LED luminaire rated 1 degree lower for the backlight ratings and 3-4 degrees lower for the uplight ratings. The measured values testified that the LED luminaire is effective for roadway lighting and light pollution reduction.

An Evaluations of Light Pollution on Roadway Lighting (도로조명의 광해 평가)

  • Cho, Sook-Hyun;Lee, Min-Wook;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.1-7
    • /
    • 2010
  • Outdoor lighting have been controlled by laws and regulations instituted in accordance with each country's situations because lights are also considered as one of pollutions at the view of environmental pollutions and energy saving. Thus, in this paper, we suggest the calculation method and regulations of light pollution suitable for domestic by comparing and analyzing various types of road lighting luminaires based on the calculation method of light pollution accepted internationally.

A Study on Making Upward Lighting Ratio Regulation for Lighting Zone Based on the Light Distribution of Streetlight Site Survey (가로등 배광의 실태조사를 통한 조명환경관리구역별 상향광속률 기준 마련을 위한 연구)

  • Lee, Young-Jin;Seo, Young-Seok;Oh, Min-Seok;Kim, Hway-Suh
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.9-15
    • /
    • 2012
  • There have been light pollution standards just for architectural lighting and sign in the "Light Pollution Abatement Law" so far. However, both of them regulate only one of the three main light pollution elements-"Glare". Therefore, it is imperative to do research on the other two light pollution elements-"Upward" and "Light Trespass" and make proper restriction. Subsequently, this study focuses on the upward light from the street light and suggests its analysis method. Eventually, this study aims to make viable management which is suitable for the nation and, in addition, to suggest appropriate level of restriction to "Light Pollution Abatement Law" by doing site survey.

Research on Effect of Installing light shield of Existing Security Lights for Preventive Measures for Light Pollution (빛공해 방지 대책을 위한 기존 보안등기구의 차광판 설치 효과 연구)

  • Han, Seung-Hun;Gu, Jin-Hoi;Lee, Yoon-Gyeong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.7-13
    • /
    • 2014
  • As issues on light pollution is being raised recently, movements to prevent light pollution is being implemented by each local government, such as by enforcing the Light Pollution Act from February 2013, in order to require compliance with the light-emitting permission level of existing lighting facilities. However, despite the regulations, no specific measures on products are being prepared. Thus, this Research has designed a light shield as a measure to minimize the burden of the effectiveness and time required for development and the burden of the cost necessary to re-install existing light facilities in its entirety and reviewed the effect of the measure through the BUG ratings.

Light Pollution Survey of Outdoor Lighting in Shopping Complex (쇼핑용 복합빌딩의 옥외조명으로 인한 광공해발생 실태조사)

  • Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.16-26
    • /
    • 2004
  • As the importance of outdoor lighting become more widely recognized, outdoor lighting has been installed in many buildings, plazas, landscape, and historical monuments in Korea, Outdoor lighting on showing complex, in particular, express its values as local landmarks. However, the excessive outdoor lighting in the large-scale shopping complex tends to cause light pollution. Many advanced countries are trying to create a comfortable lighting environment by the guidlines and regulations on outdoor lighting to prevent light pollution. For this research backgrounds, the light pollution of three showing complexes in Seoul have been investigated. For the purpose, luminance of building facade, horizontal illuminance, and vertical illuminance were measured with proper measurement instruments and compared the results with the CIE recommendations. The results of the study are as follows. As no cut-off luminaries are currently installed on pedestrian walks, some glare were occured partially. It also shows that the luminance of building facades are high to improve the degree of public awareness of buildings and advertisements. In other words, the luminance of the building facade, when compared with that of the CIE recommendations, is twice as high and the vatical illuminance of pedestrian walks is far higher than that of the CIE recommendations, which proves the existence of light pollution. As Korea has not yet provided proper regulations or guidelines for the control of light pollution, it is necessary to make appropriate codes for it.

A Study on the Luminance Measuring Method and Regional Measured Results for Outdoor Signboards with Lighting Considering Light Pollution (빛공해를 고려한 옥외발광광고물의 휘도측정법 연구 및 지역별 측정결과)

  • Kim, Hyun-Ji;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.10
    • /
    • pp.1-8
    • /
    • 2012
  • To suggest lighting regulations to prevent light pollution, domestic and international standards were analyzed and the luminance of outdoor signboards of main street at night was measured. In addition, to regulate the methods of luminance measurement, experiments on the measuring distance and direction from the signboards were conducted. The regulations were set as maximum luminance for outdoor signboard lightings of channel letter type, and limitations were suggested on each of the four lighting zones.