• Title/Summary/Keyword: Lighting Economic Evaluation

Search Result 16, Processing Time 0.022 seconds

Development of Economic Evaluation of Indoor Lighting System (실내 조명시스템의 경제성 평가법 개발)

  • Cho, Sook-Hyun;Lee, Min-Wook;Choi, Hyeon-Seok;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • An economic evaluation is required to reduce the cost of energy and lighting in the design of interior lighting. WEELS2011 is developed as a method of economic evaluation for LED lighting systems. Economic evaluation for fluorescent and LED lightings and after applying rebate to LED system is conducted using WEELS2011. The utilization and analysis of WEELS2011 are suggested for the reduction of energy and lighting cost.

Economic Evaluation of LED Luminaires for Tunnel Interior Zones

  • Cho, Sook-Hyun;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.7-13
    • /
    • 2013
  • There has been a need for the systematic evaluation of the economic efficiency between conventional fluorescent lamp lighting systems that have been used in tunnels and LED lighting systems. This study has evaluated basic tunnel lighting between the conventional fluorescent lighting systems and the LED lighting system using the evaluation tool of tunnel lighting by Life Cycle Cost (LCC) and using the economic efficiency evaluation method. In addition, the unit discount rate of the LED lighting system and the estimated increase in the price of electricity have made the estimated cost of LCC the same if two luminaires were used in the basic part of the tunnel.

A Study on the Workship Special Light Installation Case (종교시설 특수예배조명 설치 사례연구)

  • Lee, Jang-Weon;Lee, Kyung-Han;Kwon, Hyeok-Hwan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.1 no.1
    • /
    • pp.87-90
    • /
    • 2015
  • Find out about the Status and future direction of the latest special lighting, through the installation of special lighting for worship practices used in religious institutions. by applying the LED installation practices, Looked for in the past with other functional features. When replacing halogen lighting with LED lighting, According to the illumination economic evaluation, Confirmed, to be an approximately 25% reduction in the applicable. with functional factors of LED luminaires the feed will be applied more in the future.

A Study on Economic Evaluation of FPL 45[W] Lamp and Ballast to Demand Side Management (FPL45[W]램프, 안정키의 전력수요관리를 위한 경제성 평가 연구)

  • Im, Song-Kug;Cho, Hyun-Kyung;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.101-107
    • /
    • 2009
  • The energy efficiency of existing lighting appliances has continuously been improving due to the government aid such as rebate programs and information of energy saving, etc. However, the usage pattern of lighting appliance at this moment has more been increasing higher illumination and indirect lighting method according that the taste of customers has changed variously. This paper estimates the economic evaluation and simulation for FPL45[W] lamp & ballast instead of FPL55 lamp & ballast in order to study the governmental support to demand side management.

A New Economic Evaluation for Demand-Side Resource using Lighting Dimming Control for the Electricity Suppliers in Competitive Electricity Markets (조광제어를 활용한 전력판매회사 관점의 수요관리자원에 대한 새로운 가치평가 연구)

  • Kim, Jin-Ho;Kim, Seong-Cheol;Nom, Young-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.8-15
    • /
    • 2009
  • In this paper, a new demand-side evaluation for the technical potential of lighting dimming control and its applications in electricity markets have been presented. The California standard practice test has been widely used to estimate the economic value of demand-side resources. However, as the advent of deregulation and restructuring of power industry, the California test has been facing some limitations to adopt in the new market environments. In particular the conventional DC test is appropriate for the traditional vertically integrated utility, not for the restructured unbundled utility. Thus, this paper presents a new method to evaluate the economic value of demand-side resource, especially of controllable lighting dimming resource in terms of the energy service provider in market environments. We, therefore, first estimate the technical potential of the lighting dimming control and evaluate the value of the lighting dimming control based on the Korean electricity market data in 2006. The study result shows that the lighting dimming control is a cost effective option for the energy service provider.

A Study on Railroad Vehicle Lighting Environment (철도차량 조명 환경 연구)

  • Kang, Og-Goo;Jang, Woojin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.178-182
    • /
    • 2014
  • This paper investigates the lighting environment of railway system which are mainly used in KTX, Saemaul and Mugunghwa. When lighting used in KTX such as fluorescent lamp and incandescence is being replaced with LED lamp, illumination load of each railroad vehicle has been compared. The comparison result shows that the reduction of power consumption is 43.34% before and after the change. Also it has been performed the economic evaluation.

A study on Economic Evaluation of the Theater Stage Lighting System Using LED (공연장 LED 조명시스템 구성의 경제성 평가에 관한 연구)

  • Lee, Kwong-Mo;An, Kyong-Sok;Gu, Seung-Hwan;Han, Hak-Soo;Choi, Sung-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.43-53
    • /
    • 2015
  • This study analyzes economic feasibility of the LED lighting system compare to the halogen. To evaluate economic feasibility of the LED devices, we analyzed the size of theater, current value of the lighting devices in kinds, annual cost and annual cost according to the surface in case of designing stage lighting system with LED using WEELS 2011. Also, to compare energy consumption, we analyzed consumption and amount of electric energy by the surface and the amount of CO2 emission. Data showed that annual cost of the LED devices are highly inexpensive than halogen and now the value is of great. However initial cost of the equipment 200% higher than halogen. Though LED devices are expensive in startup setting, the value of utilization factor is large and depreciation years of LED(30years) are longer than halogen(2years). Therefore, annual cost of LED can make up the minus. Consider the tendency of reducing price of LED devices, we can assume that annual cost of the LED will be lower than halogen devices. Further, in 3years the expense of LED and halogen is reversed.

Feasibility Study on Retrofitting Lighting and Heat Source Equipments in Office Buildings (사무소건물 조명기기와 열원기기의 고효율기기로의 교체에 관한 경제성 검토)

  • Lee, Chul-goo;Kim, Jong-dae;Im, Tae-soon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.2
    • /
    • pp.13-18
    • /
    • 2016
  • Energy saving has been main concern, thus government supporting policies which are based on Fundamentals of Low-carbon Green Growth Act', 'Green Building Support Act, have been prepared in Korea. The objective of this study is to estimate energy conservation effectiveness and economic advantage assuming that lighting equipments and heat source equipments would be retrofitted. Office building, which has total floor area of $30,000m^2$, was a subject of this study. From the estimations, electric rate will be decreased by 62,886,000 won per year due to lighting equipments retrofit, and gas rate will be decreased 11,141,000 won or 17,332,000 won per year due to heat source equipments retrofit (in case of COP 1.2 or 1.5). Payback period of each case that are calculated by energy saving cost and retrofit cost are estimated 27.9 year, 38.6 year and 29.2 year, thus economic supporting policies is necessary for effective energy saving in buildings. Meanwhile payback period of heat source equipment for new building is estimated 6.1 year and 8.3 year.

Investigation and Economic Evaluation of Tunnel Lighting Installation for Each Light Source (광원의 종류에 따른 터널조명 설비의 실태조사 및 경제성 평가)

  • Kim, Gi-Hoon;Lee, Chang-Mo;Sim, Sang-Man;Jeong, Jong-Chul;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.93-99
    • /
    • 2001
  • 광원별로 형광등 32W 3등을 사용한 터널과 고압나트륨 램프 100W를 사용한 터널, 그리고 저압나트륨 램프 36W와 91W를 혼용한 터널의 조도 및 휘도를 측정한 결과 조도 및 휘도의 균제도는 3 가지 광원이 모두 거의 일치하였으나, 평균 조도와 정균 휘도값에 있어서 저압나트륨 램프를 사용한 터널이 절반 수준이 되는 차이를 보였다. 또한 경제성 평가 도구인 WEELS를 이용하여 터널의 길이를 300[m], 터널 폭을 10.7[m]로 일정하게 하여 경제성을 평가한 결과, 연간 비용에 있어서 고압나트륨 100W가 비용이 가장 켰고, 그 다음이 형광등 32W 3등용, 그 다음이 저압나트륨(36W+91W)이었지만 그 값은 근소한 차이였다.

  • PDF

Transient Analysis and Evaluation of 345kV Combined Transmission Line Connected with GIL (345kV급 GIL이 연계된 혼합송전선로의 뇌서지해석 및 평가)

  • Jang, Hwa-Youn;Lee, Jong-Beom;Kim, Yong-Kap;Jung, Chae-Kyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1949-1955
    • /
    • 2010
  • This paper describes the characteristic and effectiveness of combined GIL transmission line through lightning surge analysis. In addition the XLPE cable is analyzed in the same condition to compare with GIL. Lighting surge analysis is carried out by EMTP/ATP-Draw to obtain overvoltage of GIL and XLPE cable at service-point and load-out area of underground line. Propagation velocity is calculated in combined transmission lines with GIL and XLPE cable. The overvoltage is also analyzed on GIL and XLPE cable with or without arrester operation. The Analysis results show that overvoltage of GIL is occurred higher than XLPE cable at the same condition. Therefore it is evaluated that the application of GIL at the field should be considered cautiously when more detailed transient analysis, another electrical testes and economic evaluations are implemented.