• Title/Summary/Keyword: Light-weight concrete

Search Result 274, Processing Time 0.022 seconds

Study on Characteristics of Lightweight Aggregate Concrete as Types of Lightweight Aggregate (경량골재 종류 변화에 따른 경량콘크리트의 특성 연구)

  • Park, Dae-Oh;Sa, Soon-Heon;Ji, Suk-Won;Choi, Soo-Kyung;Yoo, Taek-Dong;Seo, Chee-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.67-70
    • /
    • 2007
  • As construction industry is requiring competitive power and technique in national construction market with rapid fluctuation of construction environment and development, requirements upgrading performance in construction materials are increasing. But, national lightweight aggregate and lightweight concrete's inappropriateness when produced are also increasing. And there are not international standard of aggregates in using these construction materials because standards and characteristics of aggregate in each countries are different. Therefore, in this study, lightweight aggregate acquired due to wide range of use is tested and mixed for concrete to gain practicality and set the authorized manual in international. Also, basic data will be proposed to set a standard for concrete by analyzing lightweight aggregate characteristics. When lightweight aggregate absorptivity is high, concrete shows low strength and when it's density is low, concrete shows low weight of unit volume. Furthermore, compressive strength of lightweight aggregate is steep in first and longtime material age is tendency to cause low strength increasing rate.

  • PDF

An Experimental Study on the Strength Properties of Flowing Lightweight Aggregate Concrete with Age (재령에 따른 고유동 경량골재콘크리트의 강도특성에 관한 실험적 연구)

  • Jeon, Hyun-Kyu;Yoo, Taek-Dong;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.4
    • /
    • pp.186-193
    • /
    • 1998
  • The purpose of this research is to seek properties of flowing light-weight aggregate concrete and possibility of application. The experimental analysis results by using light-weight aggregate and industrial waste such flyash, furnace slag are as follow. 1) The research shows that flowing light-weight aggregate concrete of slump 23~27cm, slump flow 58~69 cm is possible, but material segregation is appeared above slump 26.5cm and slump flow 65 cm. 2) If mixing ratio of flyash is increase, strength deterioration is about 25 % in early age. It showed that effectiveness of long time strength improvement because strength manifestation ratio is above 95% in a long term. 3) This research showed possibility of substitution of blast furnace slag because strength deterioration by using mixing of furnace slag was appeared small deterioration range as below 10 %. 4) Each experimental compressive strength ratios were 77 %(1st week), 86 %(2nd week), 109 %(8th week), 115 %(13th week), 125 % (26th week) on the basis of 28 days. If mixing ratio of flyash is increase, long term strength increase ratio is improved.

  • PDF

A Study on shrinkage of High Strength Lightweight Concrete using by-products (산업부산물을 활용한 고강도경량 콘크리트 건조수축 특성연구)

  • 장주영;윤요현;이승조;박정민;김태곤;김화중
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.36-39
    • /
    • 2003
  • In this study, we made the high strength light weight concrete which was composed of the garnet minute powder to be the industry by-product in the YoungJoo region and the artificial light weight aggregate which the high temperature(1100℃) plastic process. The characteristic of the autogenous shrinkage had been considered about strength characteristic and the age passage In the following addition: The concrete's each unit quantity was determined 145,160,175㎏f/㎥.w/b and s/a was determined 30%, 43%, 45%. the each garnet's substitution ratio was determined 0, 10%. In this results, the compressive strength appeared greatly as the unit joining discretion grew bigger. The autogenous shrinkage ratio was increased rapidly until 7th day but it was reduced after 7th day regardless of the mixed factor. The autogenous shrinkage ratio which follows the change of the unit quantity and s/a increased together as the unit quantity and the s/a increases.

  • PDF

A Study on The Quality Control of Pre-absorbed Water Light-weight Aggregate Concrete (경량콘크리트 제조를 위한 경량골재 사전흡수수 품질관리방안)

  • Lim, Sang-Jun;Lee, Han-Woo;Lee, Byung-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.199-200
    • /
    • 2011
  • Absorption of lightweight aggregate affects the properties of fresh and hardened concrete, so care must be taken. In this study, according to KS F 2533 absorption is measured to aggregate size, submerged time, holding time and practically ways to maintain a constant absorption was to seek. The findings for quality control of the lightweight aggregate concrete mixture is saturation of the surface-dry aggregate humidity 100% after 24 hours immersion in the environment has been stored for more than two days to absorb the state was able to define. Dry density at the surface of the lightweight aggregate and lightweight concrete mix design and placement is possible for it to apply.

  • PDF

The Advanced Composite Sandwich Panels for Light Weight of Road Structures (도로구조물 경량화를 위한 복합재료 샌드위치 패널에 관한 연구)

  • Han, Bong Koo
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.1-8
    • /
    • 2014
  • PURPOSES : The purpose of this paper is to demonstrate to the practicing engineers, how to apply the advanced composite materials theory to the road structures. For general construction material used, there is certain theoretical limit in sizes. For super road structure construction, the reduction in panel weight is the first step to take in order to break such size limits. METHODS : For a typical road structures panel, both concrete and advanced composite sandwich panels are considered. The concrete panel is treated as a special orthotropic plate. RESULTS : All types of advanced composite sandwich panels are considered as a self-weights less than one tenth of that of concrete panel. The concrete panel is treated as a special orthotropic plate to obtain more accurate result. CONCLUSIONS : Advanced composite sandwich panels are considered as a self-weights less than one tenth (10%) of that of concrete panel, with deflections less than that of the concrete panel. This conclusion gives good guide line for design of the light weight of road structures.

A Study on the Sound Absorption Properties of Sound Absorption Block using by Artificial Light Weight Aggregate (인공경량골재를 이용한 철도 흡음블록의 흡음특성에 관한 연구)

  • Kang, Duck-Man;Seo, Jae-Won;Lee, In-Yong;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.830-839
    • /
    • 2008
  • This study is designed to manufacture the upgraded sound absorption concrete by using foamed concrete by using artificial light weight aggregate which raises the continuous void ratio to increase the sound absorption ratio and improve the strength. In manufacturing the sound absorption block, the pre-foaming form is applied to generate continuous voids, controlling the density by the addition of bubbles. It is general that the more porosity creates, the weaker strength becomes. Each of specimens are used for this experiment and measured their absorption ratio to examine the absorption property depending on frequency. As a results of experiment, it is evaluated that the absorption capacity of the sound absorption block has relation to compression strength and surface shape.

  • PDF

Pore properties and Microstructure on the each regions of a Light-Weight Aggregate using Glass Abrasive Sludge (유리연마슬러지를 사용한 경량골재의 미세구조 및 기공 특성)

  • Kwon, Choon-Woo;Chu, Yong-Sik;Kim, Young-Yup;Jung, Suk-Joe;Song, Hun;Lee, Jong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.533-536
    • /
    • 2006
  • A light-weight aggregate with a surface layer was fabricated using glass abrasive sludge and expanding agents. The glass abrasive sludges were mixed with expanding agents ($Fe_2O_3,\;graphite,\;CaCO_3$) and formed into precursors. These precursors were sintered in the range of $700-900^{\circ}C$ for 20min. The sintered light-weight aggregate had a surface layer with smaller pores and an inner region with larger pores. The surface layer and pores controlled the water absorption ratio and physical properties. As the expanding agent fraction and the sintering temperature increased, the porosity and pore size increased. The light-weight aggregate with $Fe_2O_3$ and graphite as the expanding agents had a low water absorption ratio while the porous material with $CaCO_3$ as the expanding agent had a higher water absorption ratio and more open pores.

  • PDF

Moment-Curvature Relation of Concrete Filled Circular Steel Tubular Beam with Nonlinear Stress-Strain Properties (비선형 응력-변형률 특성을 갖는 콘크리트 충전 원형강관 보의 모멘트-곡률 관계)

  • Park, Woo-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.195-202
    • /
    • 2005
  • This paper presents moment-curvature analytical method of concrete filled steel tubular members considering intensity increase phenomenon by triaxial compression stress generation. For this purpose, this study considers buckling characteristics about compression department of steel members that filled up light weight and normal concrete. The analytical results are compared with the test results. Even if beam that filled up light weight concrete was calculated moment-curvature relationship easily analytically and could know that analytical results estimates as well agreed with the test results in case filled up normal concrete. In addition, the efficiency and applicabilities of the proposed moment curvature relationship algorithm are verified through conventional experimental results.

A Study on the Properties of Planting Concrete with the Variation of Aggregate Kinds (골재 종류 변화에 따른 식재용 콘크리트의 특성에 관한 연구)

  • 이상태;윤기원;황정하;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.187-190
    • /
    • 1999
  • This study is intended to present the properites of planting concrete using the light-weight aggregate and crushed aggregate. According to the result of experiment, the concrete using orchid stone shows a better performance in voids volume, unit weight, absorbtion, thermal conductivity and pH, which are helpful for planting and heat isolation. Therefore, if planting concrete used with orchid stone are utilized to be the planting base on the building's roof, it will be effective to reduced the cost of construction and heating due to the redution of building's self weight and heat isolation effection.

  • PDF

Properties of Concrete Panel Made by Light Weight Aggregates (인공경량골재로 제조된 콘크리트 패널의 물성)

  • 엄태호;김유택
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.3
    • /
    • pp.221-228
    • /
    • 2004
  • Basic properties of artificial lightweight aggregate by using waste dusts and strength properties of LWA concrete were studied. Bulk specific gravity and water absorption of artificial lightweight aggregates varied from 1.4 to 1.7 and 13 to 16%, respectively. Crushing ratio of artificial lightweight aggregate was above 10% higher than that of crushed stone or gravel. As a result of TCLP leaching test, the leaching amount of tested heavy metal element was below the leaching standard of hazardous material. Slump, compressive strength and stress-strain properties of LWA concrete made of artificial lightweight aggregate were tested. Concrete samples derived from LWA substitution ratio of 30 vol% and W/C ratio of 45 wt% showed the best properties overall. Thermal insulation and sound insulation characteristics of light weight concrete panel with the optimum concrete proportion were tested. Average overall heat transmission of 3.293W/㎡$^{\circ}C$ was observed. It was higher by about 15% than those of normal concrete made by crushed stone. Sound transmission loss of 50.9 ㏈ in frequency of 500 ㎐ was observed. It was higher by about 13% than standard transmission loss.