• Title/Summary/Keyword: Light tools

Search Result 305, Processing Time 0.025 seconds

Study on Improvement in Operation and Management of Ultra-light flying device Civil Complaints Management System for Ultralight Aircraft (초경량비행장치의 민원처리시스템 운용 및 관리 효율성 개선을 위한 연구)

  • Seok, Geum-chan;Jang, Moon-su;Ryu, Yeon-seung
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.237-246
    • /
    • 2020
  • The background of the research is the following: As a result of ultra-light flying device industry development, the utilization of drones and their efficiency have been increasing. However, problems regarding flight permission·approval procedure have not been improved, resulting in increased number of civil complaints. Thus, the purpose of this research is to minimize such civil petition according to the required standards of the two government organizations through enhancing the procedure for managing and employing the system. The research methods entail pinpointing the problems by analysing ultra-light flying device related literature review and by holding focus-interviews with field experts, thereby verifying and providing improved solutions. Under (MLIT) Ministry of Land, Infrastructure and Transport supervision and in accordance with aviation security law, the research provides various updated functions such as improved civil petition processing system's employment and management system, flight approval, integration of names, process, format regarding aviation photographing approval, tool buttons such as the 'Main' button in the system's homepage. This research has the following expected effects : Firstly in the law and regulations section, the clear distinction in the missions and roles of each organization enhances cooperations in tackling civil petition. Secondly the integration of civil petition process reduces time and improves efficiency. And lastly, the improvement of supplementary tools for the public is expected to minimize civil petitions. Future research needs to be conducted under the supervision of the Ministry of National Defense(MND). Factors such as systematic infrastructure for flight photography approval, related unit's reorganization following the defense reform 2.0, and guaranteed conditions for field security action units need to be ameliorated.

Basic study on proliferation control of cancer cells using combined ultrasound and LED therapeutic module (초음파와 LED를 이용한 일체형암세포 증식억제 모듈의 기초연구)

  • Cho, Kyung-rae;Choe, Se-woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.8
    • /
    • pp.1107-1113
    • /
    • 2018
  • Ultrasonography and photodynamic therapy have been proposed as useful tools as a treatment for inducing necrosis of cells using reactive oxygen species. Apoptosis is an internal mechanism necessary for cells regardless of damage. Ultrasound has the effect of inducing the apoptosis of these cells, and the frequency of 1 MHz is the most applicable area for medical use. The laser which is generally used in photodynamic therapy has a heat reaction and the treatment is limited. However, as a small light emitting diode is developed, it shows possibility to minimize the equipment and reduce heat reaction. On the other hand, there are relatively few researches on direct effects of light compared with studies using photosensitizers, and the area is also limited. Therefore, in this paper, we have developed a cancer cell proliferation control module using ultrasonic and light emitting diodes, which have relatively few side effects, and quantitatively analyze the effect of the module to propose an optimal suppression technique.

THE EFFECT OF SURFACE ROUGHNESS OF CSI(TL) MICRO-COLUMNS ON THE RESOLUTION OF THE X-RAY IMAGE; OPTICAL SIMULATION STUDY

  • Kim, Hyun-Ki;Bae, Jun-Hyung;Cha, Bo-Kyung;Jeon, Ho-Sang;Kim, Jong-Yul;Kim, Chan-Kyu;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.25-30
    • /
    • 2009
  • Micro-columnar CsI(Tl) is the most popular scintillator material which is used for many indirect digital X-ray imaging detectors. The light scattering at the surface of micro-columnar CsI(Tl) scintillator was studied to find the correlation between the surface roughness and the resultant image resolution of indirect X-ray imaging detectors. Using a commercially available optical simulation program, Light Tools, MTF (Modulation Transfer Function) curves of the CsI(Tl) film thermally evaporated on glass substrate with different thickness were calculated and compared with the experimental estimation of MTF values by the edge X-ray image method and CCD camera. It was found that the standard deviation value of Gaussian scattering model which is determined by the surface roughness of micro-columns could certainly change the MTF value of image sensors. This model and calculation methodology will be beneficial to estimate the overall performance of indirect X-ray imaging system with CsI(Tl) scintillator film for optimum design depending on its application.

Senescent Effects on Color Perception and Emotion

  • Han, Jeong-won;Kim, Bog G.;Choi, Inyoung;Park, Soobeen
    • Architectural research
    • /
    • v.18 no.3
    • /
    • pp.83-90
    • /
    • 2016
  • Senescent effects are the gradual deterioration of function caused by biological aging. Senescent effects on color vision are not clearly understood even after considerable researches. Part of the reason is that the color vision is a complex phenomenon resulting from various factors such as organic systems, and the physical (neuro-optical) and the psychological (experiential) processes of color perception. We performed a field experiment on color perceptional differences due to aging vision. Our experiment was applied to two different groups in South Korea: an experimental group (46 subjects of over the age of 61 years) and a control group (49 subjects in their twenties). The experimental tools are comprised of (1) six gradual yellowing detector board (40%, 50%, 60%, 70%, 80%, 90%); (2) pairs of vivid-strong, vivid-deep, grayish-deep, deep-dull, and bright-light tones of Blue (B) and Purple (P) colors; (3) Red (R), Yellow (Y), Green (G), Blue (B), and Purple (P) colors of dull-tones and pale-tones; and (4) a questionnaire on the semantic differential scales of the color images and color differences. A diagnosis system of gradual yellow vision, developed by the authors for this study, was adapted to generate the color detecting boards. The results are as follows. (1) There are significant differences between the two groups in detecting colors that simulate 40% and 50% of yellow vision. (2) As to the color difference detecting ability between similar tones, the experimental group shows difficulties in pairs of vivid-strong tones and deep-dull tones of the B color. And (3), the emotional responses to the dull tone and the pale tone are not stable in the red, the yellow, blue, and purple. Thus, we empirically demonstrate the specific differences in color perception between the old and young groups.

Implementation of the LDAP interoperability testing tool with object-oriented approach (객체 지향 접근을 통한 LDAP 상호운용성 시험도구 구현)

  • Kim Youn-su;Lee Soong-Hee;Lee Jong Hyup
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.5B
    • /
    • pp.247-252
    • /
    • 2005
  • The testing tools implemented up to now for the LDAP(Light-weight Directory Access Protocol) interoperability tests are not easy to modify or add new test items since their source codes are not open. The object-oriented approach, therefore, is required to implement such a testing tool which can be easily modified or add new test items. Thus we designed the architecture for the testing tool applying the object-oriented approach. Java language, appropriate for the object-oriented approach, was used to implement the testing tool. The newly implemented testing tool can modify partly to adapt to the already stored data in the test suite information even during tests. Five LDAP servers can be tested simultaneously with the same configuration setup. Actual testing for the two LDAP servers validates the usefulness of the designed architecture with the proper working of the implemented testing tool according to the architecture.

Design and Characteristic Measurement of 8000 mm Large Aperture Integrating Sphere

  • Zhang, Zhao;Wan, Zhi;Li, Xiansheng;Liu, Hongxing;Sun, Jingxu;Liu, Zexun;Wang, Yamin;Ren, Jianwei;Ren, Jianyue
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.500-509
    • /
    • 2016
  • Integrating spheres play a central role in the radiometric calibration of remote sensors. With the development of the wide field of view (FOV) remote sensors, aperture diameters of remote sensors are becoming larger and larger. To satisfy the radiometric calibration requirements of full FOV and full aperture, an 8000mm diameter large aperture integrating sphere uniform source with a variable exit port was designed and manufactured. This integrating sphere will be used for pre-launch test and radiometric calibration of remote satellites. In this paper, optical theories were used to design the output spectral radiance. The LightTools software based on ray-tracing simulation method was used to determine the best combination and distribution of inner light sources. A spectral experiment was made to verify the spectral radiance design. To reduce the influence of longtime power-on, a new characteristic measurement method was developed to obtain the radiation characteristic of the integrating sphere, which could greatly improve the measuring efficiency. This method could also be applied to measure other large aperture uniform sources. The obtained results indicate that the spatial uniformity is 98.35%, and the angular uniformity at center position is 98.78%.

Characterization of Carp (Cyprinus carpio L.) Immunoglobulin Structure

  • Choi, Sang-Hoon;Park, Kwan-Ha;Yoon, Jong-Man
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.2
    • /
    • pp.290-296
    • /
    • 2002
  • Serum immunoglobulins (Igs) from Israeli carp were purified using affinity chromatography. Fish were immunized with purified mouse IgG, and the specific fish antibodies were purified from the immune serum on a mouse IgG-immobilized agarose gel. Rabbit anti-Israeli carp Igs (R $\alpha$ I. carp Igs) antibodies were produced following hyperimmunization with mouse IgG specific carp antibodies. SDS-PAGE analysis under reducing condition showed that Israeli carp Igs were composed of two $\mu$-like heavy chains with about 82 and 50 kd, respectively, and one light chain with about 25 kd. On immunoblotting analysis, however, R $\alpha$ I. carp Igs failed to react with the light chain. When both protein A and protein G-purified normal carp Ig were compared with mouse IgG-specific Israeli carp Ig, no significant structural differences among them were observed. To investigate if there is any homology between other fish Ig molecules, cross-reactivity of R $\alpha$ I. carp Igs against Ig molecules from 6 different fish sera and mouse control serum was checked on immunoblotting analysis. As a result, R $\alpha$ I. carp Igs responded to Israeli carp, common carp, and tilapia Ig molecules. In flow cytometry study, however, R $\alpha$ I. carp Igs appeared to recognize 42.0%, 35.8% and <5% of Israeli carp, common carp and tilapia $Ig^+$ head kidney cells, respectively. The result suggests the heterogeneity between receptor Igs on B-like lymphocytes and soluble Igs in serum. It is crucial to obtain pure fish Igs to produce reagent antibodies as tools for the study on their specific immune responses.

Horse race rank prediction using learning-to-rank approaches (Learning-to-rank 기법을 활용한 서울 경마경기 순위 예측)

  • Junhyoung Chung;Donguk Shin;Seyong Hwang;Gunwoong Park
    • The Korean Journal of Applied Statistics
    • /
    • v.37 no.2
    • /
    • pp.239-253
    • /
    • 2024
  • This research applies both point-wise and pair-wise learning strategies within the learning-to-rank (LTR) framework to predict horse race rankings in Seoul. Specifically, for point-wise learning, we employ a linear model and random forest. In contrast, for pair-wise learning, we utilize tools such as RankNet, and LambdaMART (XGBoost Ranker, LightGBM Ranker, and CatBoost Ranker). Furthermore, to enhance predictions, race records are standardized based on race distance, and we integrate various datasets, including race information, jockey information, horse training records, and trainer information. Our results empirically demonstrate that pair-wise learning approaches that can reflect the order information between items generally outperform point-wise learning approaches. Notably, CatBoost Ranker is the top performer. Through Shapley value analysis, we identified that the important variables for CatBoost Ranker include the performance of a horse, its previous race records, the count of its starting trainings, the total number of starting trainings, and the instances of disease diagnoses for the horse.

Hyperlens and Metalens-based Biomedical Imaging (하이퍼렌즈 및 메타렌즈 기반 바이오메디컬 이미징)

  • Hyemi Park;Yongjae Jo;Inki Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.4
    • /
    • pp.135-142
    • /
    • 2024
  • Biomedical imaging technologies refer to imaging techniques used in biological research and medical technology that are essential for exploring biological processes, structures, and conditions. They also play a crucial role in the early diagnosis of diseases and the development of treatments. Optical imaging technologies, in particular, are the most widely used and actively researched in biological studies. The major obstacles to technological advancement are the limitations in resolution and light penetration depth. Recently, many technologies have been studied to overcome these limitations using metamaterials. These are materials that can freely manipulate the properties of light through the regular arrangement of nanostructures and have established themselves as innovative tools in the imaging field. This article aims to provide a detailed introduction to the working principles and key applications of these technologies.

The useage of the EPID as a QA tools (EPID의 적정관리 도구로서의 유용성에 관한 연구)

  • Cho Jung Hee;Bang Dong Wan;Yoon Seong Ik;Park Jae Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.16-21
    • /
    • 1999
  • Purpose : The aim of this study is to conform the possibility of the liquid type EPID as a QC tools to clinical indication and of replacement of the film dosimetry. Aditional aim is to describe a procedure for the use of a EPID as a physics calibration tool in the measurements of radiation beam parameters which are typically carried out with film. Method & Materials : In this study we used the Clinac 2100c/d with EPID. This system contains 65536 liquid-filled ion chambers arranged in a $256{\times}256$ matrix and the imaging area is $32.5{\times}32.5cm$ with liquid layer thickness of 1mm. The EPID was tested for different field sizes under typical clinical conditions and pixel values were calibrated against dose by producing images using various thickness of lead attenuators(lead step wedge) using 6 & 10MV x-ray. We placed various thickness of lead on the table of linear accelerator and set the portal vision an SDD of 100cm. To acquire portal image we change the field size and energy, and we recorded the average pixel value in a $3{\times}3$ pixel region of interest(ROI) at field center was recorded. The pixel values were also measured for different field sizes in order to evaluate the dependence of pixel value on x-ray energy spectrum and various scatter components. Result : The EPID, as a whole, was useful as a QA tool and dosimetry device. In mechanical check, cross-hair centering was well matched and the error was less than ?2mm and light/radiation field coincidence was less than 1mm also. In portal dosimetry the wider the field size the the higher the pixel value and as the lead thickness increase, the pixel value was exponentially decreased. Conclusions : The EPID was very suitable for QA tools and it can be used to measure exit dose during patients treatment with reasonable accuracy. But when indicate the EPID to clincal study deep consideration required

  • PDF