• Title/Summary/Keyword: Light Load

Search Result 946, Processing Time 0.027 seconds

Influence of dimensional ratio on collapse characteristics for the thin-walled structures of light weight (경량화용 박육부재의 형상비가 압궤특성에 미치는 영향)

  • 정종안;김정호;양인영
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.11-23
    • /
    • 1998
  • In this study, collapse test of thin-walled structure is performed under axially quasi-static and impact load in collapse characteristic to develop the optimum structural member for a light-oriented automobile. Furthermore, the energy-absorbing capacity is observed according to the variety of configuration(circular, square), aspect ratio in aluminum specimen to obtain basic data for the improved member of vehicle. In both quasi-static and impact collapse test, Al circular specimens collapse, in general, with axisymmetric mode in case of thin thickness while collapse with non-axisynmetric mode according to the thickness increase. For Al rectangular specimens, they collapse with axisymmetric mode in case of thin thickness, with mixed collapse mode according to the increase of thickness. In terms of initial max. load, Al square specimen turns out the best member among specimens, and then Al square, circular and circular with large scaling ratio, respectively. In case of quasi-static compression test, the absorbed energy per unit volume and mass shows higher in Al circular specimen, and then Al square, circular with large scaling ratio, respectively, according to shape ratio the absorbed energy per unit volume and mass in case of max. impact compression load is higher than that of static load. But the absorbed energy per unit volume and mass shows that Al circular specimen is the best member. Especially, unlike max. compression loan, the absorbed energy per unit volume and mass in impact test turns out the low value.

  • PDF

A Conduction Band Control AC-DC Buck Converter for a High Efficiency and High Power Density Adapter (고효율, 고전력밀도 아답터를 위한 도통밴드 제어 AC-DC 벅 컨버터)

  • Moon, SangCheol;Chung, Bonggeun;Koo, Gwanbon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.38-39
    • /
    • 2017
  • This paper proposes a new control method for an AC-DC Buck converter which is utilized as a front-end converter of a 2-stage high power density adapter. In the conventional adapter applications, 2-stage configuration shows higher power transfer efficiency and higher power density than those of the single stage flyback converter. In the 2-stage AC-DC converter, the boost converter is widely used as a front-end converter. However, an efficiency variation between high AC line and low AC line is large. On the other hand, the proposed conduction band control method for a buck front-end converter has an advantage of small efficiency variation. In the proposed control method, switching operation is determined by a band control voltage which represents output load condition, and an AC line voltage. If the output load increasesin low AC line, the switching operation range is expanded in half of line cycle. On the contrary, in light load and high line condition, the switching operation is narrowed. Thus, the proposed control method reduces switching loss under high AC line and light load condition. A 60W prototype which is configured the buck and LLC converter with the proposed control method is experimented on to verify the validity of the proposed system. The prototype shows 92.16% of AC-DC overall efficiency and 20.19 W/in 3 of power density.

  • PDF

A Study on the Mechanical Reliability of Large-area Bi-facial Glass-to-glass Photovoltaic Modules (대면적 양면 태양광 모듈의 기계적 신뢰성 연구)

  • Yohan, Noh;Jangwon, Yoo;Jaehyeong, Lee
    • Current Photovoltaic Research
    • /
    • v.10 no.4
    • /
    • pp.111-115
    • /
    • 2022
  • For the high efficiency of the photovoltaic module, a high-output solar cell, which is the basis of photovoltaic power generation, is required. As the light receiving area of the solar cell increases, the light receiving area of the photovoltaic module also increases. Accordingly, recent trend is to use large-area solar cells such as M6 and M8 instead of M2-based solar cells for manufacturing the photovoltaic module and a study on the mechanical stiffness of the module with increased size is required. In this study, a mechanical load test corresponding to IEC-61215 was performed among the reliability tests of large-area photovoltaic modules. In order to confirm the degree to which the mechanical load test affects the photovoltaic module, the output and EL images were checked by sequentially increasing the pressure by 600 Pa at a pressure of 2400 Pa. Also, factors such as output and efficiency of large-area photovoltaic modules were verified through mechanical load testing of actual large-area photovoltaic modules and the rate of change was very small at 1%.

Development of Lightweight Plastic Formwork through Efficiency(Load) Test (경량 플라스틱 거푸집 개발 및 성능(하중재하) 시험)

  • Kang, Sin Hun;Lee, Changsu;Kwon, Woobin;Ahn, Heejae;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.10-11
    • /
    • 2020
  • Currently, the most used forms, such as euro form and aluminum form, has many problems. There are issues with noise of construction site because of existing forms' material and issues with safety because of heavy weight. To solve these problems, there are many researches on using plastic and composite materials on the formwork. However, plastic has lower tensile strength than the steel and aluminum and composite materials are expensive. Therefore, constructors are avoid to use the forms with new materials. The purpose of this study is to develop light-weight plastic form to solve these existing problems by using ABS with optimized design. To verify, the study measured the amount of deflection from developed form through a load test. The test result showed a deflection of 1.15mm when 1.4ton was loaded in the middle of form. The result of the study verified that the usage of ABS and optimized design effectively reduced the weight and noise. Also, it's performance was verified through the load test.

  • PDF

New control strategy of Static Inverter for the Light Rail Transit (경량전철용 보조전원장치의 새로운 제어 기법)

  • Lee, Eun-Kyu;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.190-193
    • /
    • 2003
  • This paper Proposes 40 [KVA] rated SIV(Static Inverter) system for Light Rail Transit. The SIV Provide power of a fluorescent light in the car, Air-conditioner. and other equipments. To control output voltage it is used voltage control loop for constant voltage control and simultaneously used current control loop for instantaneous control at load changing. The Performance of SIV system will be verified by experimental results.

  • PDF

Development of Static Inverter for the Light Rail Transit (경량전철용 보조전원장치의 개발)

  • 이은규;염상구;최재호
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.522-527
    • /
    • 2002
  • This paper proposes 40 [KVA] rated SW(Static Inverter) system for Light Rail Transit. The SIV provide power of a fluorescent light in the car, Air-conditioner, and other equipments. To control output voltage it is used voltage control loop for constant voltage control and simultaneously used current control loop for instantaneous control at load changing. The performance of SW system will be verified by experimental results.

  • PDF

A Structural Analysis on the Light Rail Vehicle Body with Composite Material (복합재료 경전철의 차체구조 해석)

  • 이영신;김재훈;이호철;길기남;박병준
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.437-446
    • /
    • 1999
  • The structural behavior of the composite material light rail vehicle body are investigated. Composite material is very useful for light rail vehicle structure due to its high specific strength and lightweight characteristics. The main carbody is made of aluminum alloy. The side wall and roof with composite panels can reduce total vehicle weight about 2000kg. In addition, with the lower density of the foam, enhances lightness in the panel and to save the operation expenses. The finite element analysis code, ANSYS is used to evaluate the stability of the body structure under the various load conditions.

  • PDF

Data Load Process of large-sized media for avionics using FTP and JSON (FTP와 JSON을 활용한 대용량 미디어의 항공장비용 데이터 로드 프로세스)

  • Ji-Hwan Choi;Nak-Min Choi;Jae-Kwon Shin
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.5
    • /
    • pp.610-620
    • /
    • 2023
  • The interest in the aircraft interior market is gradually growing due to technological development based on the 4th industrial revolution and competition for airlines to attract customers, and as part of that, Cabin Display System (CDS) for FAA Part.25 civil aircraft is being developed in Korea. The CDS is a system that provides various multimedia services to passengers by utilizing Flexible and Transparent Organic Light Emitting Diodes (OLED) with Integrated Display Processing Module (IDPM). This paper presents a new method for efficient Data Load Process of large-sized files and deals with their implementation and performance. The results of this study are expected to be applied to Data Load Process development of avionics that require reliable large-capacity file transmission along with reducing the costs of development compared to existing ARINC-615A.

Fundamental Study on Estimating Compressive Strength and Physical Characteristic of Heat insulation Lightweight Mortar With Foam Agent (기포제 혼입 단열형 경량모르타르의 물리적 특성 및 압축강도 추정에 관한 기초적 연구)

  • Min, Tae-Beom;Woo, Young-Je;Lee, han-Seung
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.89-96
    • /
    • 2010
  • In comparison with ordinary or heavy-weight concrete, light-weight air void concrete has the good aspects in optimizing super tall structure systems for the process of design considering wind load and seismic load by lightening total dead load of buildings and reducing natural resources used. Light-weight air void concrete has excellent properties of heat and sound insulating due to its high amount porosity of air voids. So, it has been used as partition walls and the floor of Ondol which is the traditional Korean floor heating system. Under the condition of which the supply of light-weight aggregates are limited, the development of light-weight concrete using air voids is highly required in the aspects of reduced manufacturing prices and mass production. In this study, we investigated the physical properties and thermal behaviors of specimens that applied different mixing ratios of foaming agent to evaluate the possibility of use in the structural elements. We proposed the estimating equation for compressive strength of each mix having different ratio of foaming agent. We also confirmed that the density of cement matrix is decreased as the mixing amount of foaming agent increase up to 0.6% of foaming agent mixing ratio which was observed by SEM. Based on porosity and compressive strength of control mortar without foaming agent, we built the estimating equations of compressive strength for mortars with foaming agent. The upper limit of use in foaming agent is about 0.6% of the binder amount. Each air void is independent, and size of voids range from 50 to $100{\mu}m$.

Field Application and Load Test of Composite Deck Bridge (복합소재 바닥판 교량의 현장적용과 재하시험)

  • Lee Sung-Woo;Kim Je-In;Jo Nam-Hoon;Yang Pil-Seung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.113-120
    • /
    • 2005
  • To substitute conventional reinforced-concrete bridge deck glass composite precast bridge deck - Delta $Deck^{TM}$, which possesses advantages of light weight, high strength, corrosion resistance and durability, is developed for the DB24 truck load. Pultruded composite bridge deck is designed and fabricated. In this paper some field applications and field load test of developed composite deck bridge are presented.

  • PDF