• Title/Summary/Keyword: Light Curve

Search Result 567, Processing Time 0.039 seconds

Catalytic Oxidation of 1.2-Dichloroethane on Precious Metal Catalysts (귀금속 촉매를 이용한 1.2-Dichloroethane의 산화분해에 관한 연구)

  • Lee, Hae-Wan;Kim, Young-Chai;Moon, Sei-Ki
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.497-503
    • /
    • 1998
  • The catalytic oxidation of 1.2-dichloroethane was investigated over precious metal supported on alumina using a fixed bed microreactor. Among the catalysts tested, the conversion of 1.2-dichloroethane decreased in the following order : Ru > Pt > Pd $${\sim_=}$$ Rh and Pt was found to be the most active catalyst for the complete oxidation of 1.2-dichloroethane to $CO_2$. Major products containing carbon were vinyl chloride and $Co_2$ at temperature ranging from 200 to $400^{\circ}C$. The presence of vinyl chloride in products suggests that the first step in the oxidation of 1.2-dichloroethane is dehydrochlorination and the second is oxidation of vinyl chloride to $CO_2$. To investigate the effect of HCl on the activity of the complete oxidation, some experiments were conducted by adding HCl to the feed. The presence of HCl increased the conversion of 1.2-dichloroethane below $300^{\circ}C$ owing to the increase of surface acidity, but it didn't affect the conversion above $300^{\circ}C$. The reversible adsorption of HCl onto catalyst surface inhibited the complete oxidation to $CO_2$.

  • PDF

Changes of Hysteresis Loop Characteristics of the Tendon Under Tensile Stress (Tendon의 인장응력에 따른 자기이력특성 변화의 측정)

  • Kang, Sunju;Son, Derac;Joh, Changbin;Lee, Jungwoo
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.4
    • /
    • pp.123-128
    • /
    • 2015
  • The iron is an element having a high yield strength, mechanical hardness, good electrical conductivity, and also it has been used in various fields because of ease machining. In bridges have been used tendon made of a steel wire for large loads and light weight. Tension measurement of tendon employed in PreStressed Concrete (PSC) bridge is very important for the bridge safety check. NDT (Non-Destructive Testing) is essential for the safety check, however, magnetic NDT is difficult to apply due to the non-linear magnetization curve and hysteresis loop in the magnetic properties. In this work, for basic study of magnetic NDT application, we have constructed a B-H loop measuring system for 7-strand tendon of which diameter is 15.5 mm, and which can apply tensile stress up to 2.0 GPa. We have measured hysteresis loops of two kinds of tendons under different tensile stress. Amplitude permeability and maximum magnetic induction near knee show the most sensitive and high linearity depends on tensile stress. Relative amplitude permeability was decreased from 500 to 200 and maximum magnetic flux density changed 0.6 T.

The Study on the Statistical Characteristics of Road Traffic Noise in Apartment Complex (국내 단지도로에서 도로교통소음에 대한 통계학적 특성연구 -도로교통 소음원이 수음점에 미치는 수평.수직 음원 분포특성 중심으로-)

  • Cho, Il-Hyoung;Chang, Soon-Woong;Kang, Sung-Won;Kim, Seog-Ku;Ko, Jung-Young
    • Journal of Environmental Science International
    • /
    • v.16 no.10
    • /
    • pp.1179-1187
    • /
    • 2007
  • This paper represents the statistical characteristics of sources and receptors for road traffic noise in apartment complex. Also we suggested that the site-specific characteristics of vertical and horizontal distributions in the complex apartment have been derived using a different analysis for evaluating levels of Leq1h by the apartment floor at a given distance from a road in terms of the flow rate, the mean speed of the traffic, and the percentage of the type vehicles in the day and night periods. As a result, the contribution orders of traffic quantity by the type of vehicles showed as followed: light vehicle>medium vehicle>heavy vehicle>motorcycle. Especially, the mixing ratio of entering the road on the heavy vehicle in the daytime was two times higher than that of in the night. The speed in all types of vehicle is in the range of 41 and 81 km/hr and noise level was not significantly different in day and night-time. The sources of road traffic noise had different variations and uncertainties using a random variable and probability distribution. The sound distribution to receptors by the apartment floor showed S curve between 1st floor and $15^{th}$ floor With the normality test, the normal distributions using Anderson-Darling Test followed $1^{st},\;3^{th},\;13^{th}$ and $15^{th}$, floor in the daytime and all floors except $7^{th}$ floor in the night (p>0.05). And also, the value of the pearson correlation coefficient (r) obtained in this study have significantly different at the range of floor. In conclusion, the results suggested that the distribution characteristics of levels of $Leq_{1h}$ on the sources and receptors of road traffic noise in apartment complex must be improved and developed on the guideline of regulation of road traffic noise.

Qualitative Evaluation of 2D Dosimetry System for Helical Tomotherapy (2차원 토모테라피 선량측정시스템의 정성적 평가)

  • Ma, Sun Young;Jeung, Tae Sig;Shim, Jang Bo;Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.193-198
    • /
    • 2014
  • The purpose of this study is to see the feasibility of the newly developed 2D dosimetry system using phosphor screen for helical tomotherapy. The cylindrical water phantom was fabricated with phosphor screen to emit the visible light during irradiation. There are three types of virtual target, one is one spot target, another is C-shaped target, and the other is multiple targets. Each target was planned to be treated at 10 Gy by treatment planning system (TPS) of tomotherapy. The cylindrical phantom was placed on the tomotherapy table and irradiated as calculations of the TPS. Every frame which acquired by CCD camera was integrated and the doses were calculated in pixel by pixel. The dose distributions from the fluorescent images were compared with the calculated dose distribution from the TPS. The discrepancies were evaluated as gamma index for each treatment. The curve for dose rate versus pixel value was not saturated until 900 MU/min. The 2D dosimetry using the phosphor screen and the CCD camera is respected to be useful to verify the dose distribution of the tomotherapy if the linearity correction of the phosphor screen improved.

The Fundamental Studies and Development of Modified Electrothermal Vaporization Hollow Cathode Glow Discharge Cell (개선된 전열증기화 속빈음극관 글로우 방전셀의 기초연구 및 개발)

  • Lee, Seong-Hun;Cho, Won-Bo;Jeong, Jong-Pil;Choi, Woo-Chang;Kim, Kyu-Whan;Woo, Jeong-Su;Lee, Chang-Su;Kang, Dong-Hyun;Lee, Sang-Chun
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.514-520
    • /
    • 2002
  • The electrothermal vaporization (ETV) hollow cathode glow discharge atomic emission spectrometer for analysis of liquid sample has been developed and characterized. This system has improved the sample introduction method of electrothermal vaporization and the hollow cathode glow discharge. The sample introduction method was possible to provide high analyte transport efficiency to the plasma by helix coil made of tungsten material. In addition, small volume samples (<$30{\mu}{\ell}$) could be used. The system has glow discharge cell with special design for improvement of precision. The effect of discharge parameters such as discharge power, gas flow rate has been studied to find optimum condition. The emitted light was effectively carried into detector by fiber optic cable in UV region. The calibration curve of Pb, Cd were obtained with 3 samples.

A Study on the Circadian Rhythm of Opiate Receptor in Rat Brain (백서 뇌내 Opiate 수용체의 일주기 변동에 대한 연구)

  • Lee, Moo-Suck;Kim, Ki-Won;Cho, Kyu-Park
    • The Korean Journal of Pharmacology
    • /
    • v.20 no.2
    • /
    • pp.23-34
    • /
    • 1984
  • To investigate diurnal variations of opiate receptor binding and its modification by experimental condition or treatment of various centrally-acting drugs, the amount of maximum $^3H-morphine$ binding in rat midbrain homogenates was measured at 4 hour intervals for 24 hours. Animals were conditioned under the controlled L : D, 12 : 12 cycle or D: D, 12 : 12 cycle, for 3 weeks and treated with 0.5 ml of physiological saline or drugs for 2 weeks. A highly significant diurnal rhythm with peak at 22 hour of early dark phase with an amplitude$(0.68{\pm}0.06\;pmole/mg\;protein)$ of +51.1% and nadir $(0.33{\pm}0.03\;mole/mg\;prtein)$ at 18 hour of late light phase with an amplitude of -26.6% was found in control group. 24 tour mean of $^3H-morphine$ binding was $0.45{\pm}0.03\;pmole/mg$ protein respectively. Constant dark adaptation or treatment of reserpine, pargyline, imipramine, amphetamine and chlorpromazine modified the diurnal rhythm in the time of peak and nadir binding shape, phase, amplitude of the diurnal curve and 24 hour mean of $^3H-morphine$ binding. However, Kd values were not changed in all experimental groups : Statistical analysis at times of least and great binding indicates that the differences in $^3H-morphine$ binding were due to changes not in the affinity, but in the number of binding sites. The results are interpreted with regard to the diurnal rhythm of opiate receptor finding. The modes of action of psychoactive drugs are closely related to postulated changes of receptor sensitivity in neuropharmacological aspects.

  • PDF

Crashworthiness Analysis and Shape Design Optimization of Thin-walled Corrugated Tubes under Axial Impact (축 방향 충격을 받는 박판 파형관의 충돌안전도 해석 및 형상 최적설계)

  • Ahn, Seung Ho;Jung, Hyun Seung;Kim, Jin Sung;Son, Seung Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.128-135
    • /
    • 2021
  • Thin-walled tubes have been widely used as energy absorbing devices because they are light and have high energy-absorption efficiency. However, the downside is that conventional thin-walled tubes usually exhibit an excessive initial peak crushing force (IPCF) and a large fluctuation in the load-displacement curve, and thus lack stability as energy absorbing devices. Corrugated tubes were introduced to reduce IPCF and to increase the stability of collision energy-absorbing devices. Since the performance of corrugated tubes is highly influence by geometry, design optimization methods can be utilized to optimize the performance of corrugated tubes. In this paper, we utilize shape design optimization based on an adaptive surrogate model for crashworthiness analysis. The amplitude and wavelength of the corrugation, as well as curvature changes in the features, are the design variables. A morphing methodology is adopted to perform shape design parameterization. Through numerical examples, we compare optimal design results based on the adaptive surrogate model, with optimal results based on conventional surrogate models, and we show that direct optimal design methods produce more efficient results.

Selecting Appropriate Seedling Age for Restoration Using Comparative Analysis of Physiological Characteristics by Age in Abies koreana Wilson

  • Seo, Han-Na;Chae, Seung-Beom;Lim, Hyo-In;Han, Sim-Hee;Lee, Kiwoong
    • Journal of Forest and Environmental Science
    • /
    • v.37 no.4
    • /
    • pp.315-322
    • /
    • 2021
  • The aim of this study was to investigate the sensitivity to environmental stress, and changes in the photosynthesis capacity in Abies koreana seedlings by age and to suggest the most effective age for restoration. To identify these physiological characteristics of A. koreana, the chlorophyll fluorescence and photosynthetic capacity of 1-, 2-, 3-, 5- and 6-year-old A. koreana seedlings were observed from June 2020 to June 2021. The maximum quantum efficiency of Photosystem II (Fv/Fm), a chlorophyll fluorescence measurement parameter, was strongly positively correlated with the monthly average temperature (1-year-old seedling: r=0.8779, 2-year-old seedling: r=0.8605, 3-year-old seedling: r=0.8697, 5-year-old seedlings: r=0.8085, and 6-year-old seedlings: r=0.8316). The Fv/Fm values were the lowest in winter (November 2020-March 2021). In addition, the Fv/Fm values of 1-, 2-, and 3-year-old seedlings in winter were lower than that of 5- and 6-year-old seedlings, while the Fv/Fm values in summer were relatively higher than those in winter. Further, the Fv/Fm values of seedlings of all ages decreased in August 2020, when the monthly average temperature was the highest. In particular, 1-year-old to 3-year-old seedlings showed Fv/Fm values less than 0.8. Further, the photosynthetic capacity measured in August 2020 increased with increasing seedling age. The analysis of variance results for summer Fv/Fm values showed significant differences in age-specific averages (p<0.05), and Duncan's multiple range test showed significant differences between 5- and 6-year-old seedlings and 1-, 2-, and 3-year-old seedlings (p<0.05). These results suggested that the 5- and 6-year-old seedlings were less sensitive to environmental stress and showed better photosynthetic capacity than the 1-, 2-, and 3-year-old seedlings. Therefore, 5-year-old or older A. koreana seedlings can be used as restoration materials because they can show increased adaptability and stable growth during transplantation due to their relatively high environmental resistance and photosynthetic capacity.

A Study on Technological Forecasting for Promising Alternative Technologies Using Fisher-Pry Modification Model (Fisher-Pry 수정모형을 활용한 유망대체기술 예측에 관한 연구)

  • Hong, Sung-Il;Kim, Byung-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.5
    • /
    • pp.104-114
    • /
    • 2019
  • In the global market competition, countries and businesses are actively engaged in technology prediction activities to maximize their profits by attempting to enter and preempting the core technology of the future. In this paper, we propose a growth model based on patent application trends to predict the time to replace a product with a promising new technology to dominate the market. Although the Fisher-Pry model that Bhargava generalized to predict the emergence of promising alternative technologies was relatively satisfactory compared to the original Fisher-Pry model, it was difficult to predict the replacement rate behavior properly due to a parameter problem. The application of the Fisher-Pry Modification Model in the form of a quadratic equation through the patent trend analysis of the optical storage system for the purpose of verifying the time alternative to the light storage technology has resulted in satisfactory verification results. It is expected that small and medium-sized companies and individual researchers will apply this model and use it more easily to predict the time to replace the market for promising replacement technologies.

Structural Stability Analysis of Medical Waste Sterilization Shredder (의료폐기물 멸균분쇄용 파쇄기의 구조적 안정성 분석)

  • Azad, Muhammad Muzammil;Kim, Dohoon;Khalid, Salman;Kim, Heung Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.6
    • /
    • pp.409-415
    • /
    • 2021
  • Medical waste management is becoming increasingly important, specifically in light of the current COVID-19 pandemic, as hospitals, clinics, quarantine centers, and medical research institutes are generating tons of medical waste every day. Previously, a traditional incineration process was utilized for managing medical waste, but the lack of landfill sites, and accompanying environmental concerns endanger public health. Consequently, an innovative sterilization shredding system was developed to resolve this problem. In this research, we focused on the design and numerical analysis of a shredding system for hazardous and infectious medical waste, to establish its operational performance. The shredding machine's components were modeled in a CAD application, and finite element analysis (FEA) was conducted using ABAQUS software. Static, fatigue, and dynamic loading conditions were used to analyze the structural stability of the cutting blade. The blade geometry proved to be effective based on the cutting force applied to shred medical waste. The dynamic stability of the structure was verified using modal analysis. Furthermore, an S-N curve was generated using a high cycle fatigue study, to predict the expected life of the cutting blade. Resultantly, an appropriate shredder system was devised to link with a sterilization unit, which could be beneficial in reducing the volume of medical waste and disposal time, thereof, thus eliminating environmental issues, and potential health hazards.