• Title/Summary/Keyword: Life test method

Search Result 2,078, Processing Time 0.035 seconds

Some considerations for the analytical approaches to measure atmospheric ammonia: tests on a relative performance of a portable colorimeter against UV/VIS spectrophotometer (대기 중 암모니아 성분의 분석법 연구: UV/VIS 분광계를 이용한 간이비색계의 상대 성능평가)

  • Kim, K.H.;Park, S.Y.;Kim, S.T.
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.425-430
    • /
    • 2005
  • In this study, we investigated the performance of a portable colorimeter used for the measurements of atmospheric ammonia against the more reliable method like UV/VIS spectrophotometer. For the purpose of this study, we tested a portable colorimeter and UV/VIS spectrophotometer for such basic analytical parameters as detectibility, reproducibility, linearity, and accuracy. According to our study, the performance of the colorimeter was fairly good to show a good agreement with the UV/VIS system. However, the performance of colorimeter suffered from both low and high concentration ranges: it was found to have very poor reproducibility at lower concentration (below $10\mu}g$), while its linear dynamic range was limited at the upper end (e.g., near $100{\mu}g$). If we assume that air samples are collected up to 30 liter, it implies that the colorimeter can be used to measure samples containing NH3 in the range of 500 ppb to 5 ppm (without the aid of diluting technique). Consequently, we recommend the use of such instrument with the awareness of its basic properties pertaining to the fundamental performance (such as its detectable range).

Mechanical Characteristics of Cementing Plane in Concrete Repair under Various Cementing Conditions (접합조건에 따른 콘크리트 접합부의 역학적 특성)

  • 김재동;정요훈
    • Tunnel and Underground Space
    • /
    • v.13 no.5
    • /
    • pp.362-372
    • /
    • 2003
  • Since the occurrence of Portland cement, a great number of concrete structures were constructed. But the concrete structures have their own life times, which inevitably demand repairing treatments, especially on their surface parts. Currently many various methods have been developed and are being applied fer this purpose. In this study, a newly developed method using pneumatic chipping machine and anchor pin was adopted far repair of old concrete structure and the mechanical characteristics of cementing plane between existing and new concrete were tested. Comparing the removal methods for the decrepit part of existing concrete using pneumatic chipping machine and hydraulic breaker, the peak cohesion was higher when using chipping machine at the cementing plane. On the other hand, the residual cohesion was higher for the case of breaker. Step shaped chipping on the cementing plane was effective in increasing peak cohesion, which results 14% increase in the case of 30 mm step height and 22% in 50 mm height when compared with planar chipping plane. The use of anchor pin increased the residual cohesion, which restricted shear slip on the cementing plane after peak shear stress and the tensile strength of 32% compared with that of non-anchored case. According to the combined effect of step shaped chipping of 30 mm and anchor pin with an interval of 15 cm, the peak cohesion reached up to 77% and the residual cohesion showed 180% of the ones of the fresh concrete, respectively.

Quality Characteristics of Surimi Manufactured by Alaska Pollack, Barren Hen Breast Meat and Mechanically Deboned Chicken Meat (명태, 폐계가슴살 및 기계발골계육을 활용한 수리미의 품질 특성)

  • Jin, S.K.;Kim, I.S.;Yang, H.S.;Choi, Y.J.;Kim, B.G.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.3
    • /
    • pp.395-404
    • /
    • 2007
  • This study was carried out to compare the physico-chemical and sensory characteristics of surimi manufactured by four different materials. We prepared surimi from alaska pollack, as the control, by washing method. The different treatments of surimi were manufactured by pH 11.0 adjustments with barren hen breast meat(T1), commercial mechanically deboned chicken meat(MDCM)-S. Co. (T2)and MDCM- J. Co.(T3). Whiteness, cohesiveness and overall acceptability were significantly higher but gumminess, chewiness and gel characteristics were significantly lower in control than other surimi samples(P<0.05). Lightness, brittleness, deformation, jelly strength and flavor were higher but texture properties and folding test of T1 were lower than those of other treatments(P<0.05). Texture properties, shear force and gel characteristics were higher, while deformation and acceptability of T2 were lower than those of other treatments(P<0.05). On the other hand, cohesiveness was higher, and lightness and whiteness were lower in T3 than those of other treatments(P<0.05). Correlation coefficients(>0.9) among texture properties and gel characteristics was positive, while negative among surface surimi colors(P<0.05). The content of crude protein, cohesiveness and gel characteristics indicated that the acceptable surimi can be made is replaced barren hen breast meat and MDCM.

Stabilization of As Contaminated Soils using a Combination of Hydrated Lime, Portland Cement, FeCl3·6H2O and NaOH (소석회, 포틀랜드 시멘트, FeCl3·6H2O, NaOH를 이용한 비소 오염토양의 안정화)

  • Moon, Deok-Hyun;Oh, Da-Yeon;Lee, Seung-Je;Park, Jeong-Hun
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.1
    • /
    • pp.47-53
    • /
    • 2010
  • The purpose of this study was to investigate the effectiveness of a stabilization treatment for As contaminated soil. A combination of hydrated lime, Portland cement, $FeCl_3{\cdot}6H_2O$, and NaOH were used as stabilizing agents. The effectiveness of stabilization treatment was evaluated by the Korean Standard Test (KST) method (1N HCl extraction). Sequential extractions were performed to investigate the As distribution after treatment. Following the application of the treatment, curing periods of up to 7 and 28days were investigated. The experimental results showed that a combination of hydrated lime/Portland cement was more effective than treatments of hydrated lime or Portland cement at immobilizing As in the contaminated soil. The treatment of 25wt% hydrated lime and 5wt% Portland cement was effective in reducing As leachability less than the Korean warning standard of 20 mg/kg. However, the treatments of hydrated lime and Portland cement failed to meet the Korean warning standard even when up to 30 wt% was used. The treatment utilizing hydrated lime and $FeCl_3{\cdot}6H_2O$ was not effective in properly reducing As leachability. The addition of $FeCl_3{\cdot}6H_2O$ was negative in terms of pH condition. Moreover, the treatment with hydrated lime/NaOH was effective in reducing As leachability but not as much as hydrated lime/Portland cement. The sequential extraction results indicated that the residual phase was greatly increased upon the treatment of hydrated lime/Portland cement. It was concluded that the hydrated lime/Portland cement treatment was the best among the other combinations studied at achieving trace As concentrations.

The Effect of Anchorage with Shear Reinforcement in Flat Plate System (플랫 플레이트 구조에서 전단보강체의 정착성능에 따른 전단보강효과)

  • Choi, Chang-Sik;Bae, Baek-Il;Choi, Yun-Cheul;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.667-675
    • /
    • 2012
  • Flat plate are being used more in buildings requiring a high level of technical installations or in buildings needing changeable room arrangements during their life time such as office buildings. The main problem in flat plate is its weak resistance against a punching failure at its slab-column connections. Therefore, in this research, an experimental study on full-scale interior slab-column connection was performed. Three types of shear reinforcements were tested to prevent brittle punching shear failure that could lead to collapse of the structure. A series of four flat plate specimens including a specimen without shear reinforcement and three specimens with shear reinforcements were tested. The slabs were tested up to failure using monotonic vertical shear loading. The presences of the shear reinforcements substantially increased punching shear capacity and ductility of the interior slabcolumn connections. The test results showed that a slab that did not have enough bond length failed before shear reinforcement yielded due to anchorage slip. Also, FEM analyses were performed to study an effect of slab thickness and concrete compressive strength on the flat plate slab. The analytical study results were used to propose a method to calculate performance capacity of shear reinforcement in slab-column connection.

Welfare Activation Strategy for a Urban Park Users (도시공원 이용자들을 위한 공원복지 활성화전략 -부산도시공원 이용자를 중심으로-)

  • Kim, Kyo-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.195-204
    • /
    • 2012
  • The purpose of this study is to suggest the improvement plan for the welfare in the park through the empirical test on the park facilities, which are the hardware, and the service contents, which are the software, in the urban parks of Busan. Therefore, to identify the welfare of the parks in Busan, this study took 7 urban parks as samples according to the plate method of experts, and conducted the questionnaire survey from 1,500 persons using these parks. The IPA analysis results on the importance and the satisfaction of the users on the form of use, facilities and the contents of the park are as follows. First, the convenient facilities, which are the hardware of the park, are represented as a intensive management item. Second, the importance and the satisfaction for all the facilities and the contents of each park are significant differences. according to the location of each park and the characteristics of each principal park users. Such results mean that the Busan urban park operation does not satisfy the expectation of the park users for the welfare facilities in the parks. Therefore, it implies that to activate the urban parks and to improve the quality of life than the present, the aceessibility of the local residents to the information should be reinforced through the development of contents to reflect the region and the desires of the users and through building and managing the homepage of the urban parks.

A study of on site Pilot plant test of drying sewage sludge using Chain crusher flash dryer (타격기류 건조장치에 의한 하수슬러지의 건조 실증실험에 관한 연구)

  • Ahn, June-Shu;Kim, Byung-Tae;Cho, Jung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5628-5636
    • /
    • 2012
  • Effective drying method of sewage sludge is researched in this study. To dry the sludge, chain crusher flash dryer was adopted to remove moisture content in the cell which is mostly responsible for the sludge moisture content. And Pilot plant experiment was conducted in real life sewage treatment plant to study effect and characteristics of operating conditions. Operating variables include sludge feeding rate, rotational speed of chain, process temperature and feed moisture content. As rotational speed of chain increased, product yield of sludge increased, and the performance of the testing system increased. And, as process temperature increased, the sludge drying efficiency increased. It is found that optimum feed moisture content is at 60% which shows the maximum sludge product yield and about 10 moisture content(%) of sludge product. Sludge feed rate showed optimal value, and when the sludge feed rate is exceeded, sludge product yield did not increased but the amount of residue increased. Pilot plant experiment results are as follow. The optimal condition for the rotational speed of chain 1600rpm(max. speed), final sludge discharge temperature $80^{\circ}C$, feed moisture content 60%, and feed rate 60kg/h. When the plant was operated at the optimal conditions, the final product showed fairly good results such as sludge product yield 85.5%, moisture content 11.0% and sludge drying efficiency 81.7%.

Characterization of manganese oxide supercapacitors using carbon cloth (Carbon Cloth을 이용한 이산화망간 슈퍼커패시터 특성 연구)

  • Lee, Seung Jin;Kim, Chihoon;Ji, Taeksoo
    • Journal of Digital Contents Society
    • /
    • v.18 no.6
    • /
    • pp.1199-1205
    • /
    • 2017
  • Global energy consumption is rapidly increasing yearly due to drastic industrial advances, requiring the development of new energy storage devices. For this reason, supercapacitors with fast charge-discharge, long life cycle and high power density is getting attention, and have been considered as one of the potential energy storage systems. In this research, we developed a supercapacitor that consists of amorphous manganese oxide($MnO_2$) electrodes deposited onto carbon cloth substrates using the hydrothermal method. The Fe-doped amorphous $MnO_2$ samples were characterized by X-ray diffraction(XRD), Energy Dispersive X-ray spectroscopy(EDX), as well as scanning electron microscopy(SEM). The electrochemical analysis of the prepared samples were performed using cyclic voltammetry and galvanostatic charge-discharge measurements in 1M $Na_2SO_4$ electrolyte. The test results demonstrate that the supercapacitor based on the Fe-doped amorphous $MnO_2$ electrodes has a specific capacitance as high as 163F/g at 1A/g current density, and good cycling stability of 87.34% capacitance retention up to 1000 cycles.

Knowledge, Attitude, and Behavior Status on Oral Health Care of Geriatric Care Workers in Long-Term Care Facilities (장기요양시설 요양보호사의 구강건강관리에 대한 지식, 태도, 행동)

  • Jeon, Hyun-Sun;Han, Sun-Young;Chung, Won-Gyun;Choi, Jong-Hoon
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.569-576
    • /
    • 2015
  • The aim of this study was to assess the oral health knowledge, attitude and behavior among geriatric care workers in long-term care facilities. A self-administered questionnaire was obtained from 212 geriatric care workers attending a professional education program of 2014 dementia pilot project. The questionnaire consisted of 4 parts of the training experience (2 items), knowledge (16 items), attitude (13 items), and behavior (4 items) on oral health care. Collected data were analyzed by frequency analysis, independent t-test, and one-way ANOVA using SPSS Statistics ver. 20.0. The percentage of educational experience on oral care was 27.9% and most respondents answered that they have received the education about denture cleaning (98.3%) and brushing method (91.4%). The average knowledge score was $10.88{\pm}1.70$, and respondents showed high-level agreement in 8 of the 10 items in attitude questions. They revealed difficulties in providing oral care to the elderly people because of their lack of knowledge. The deficiencies of knowledge about oral care would have a decisive effect on not only oral and general health, but also quality of life of the elderly people. Therefore, it is required to develop professional oral care training programs for geriatric care workers and support systems should be legalized.

Interface Design Guideline for Personalization of Interactive TV Service - Focusing on SkyLife's SkyTouch Service - (쌍방향TV 서비스의 개인화를 위한 인터페이스 디자인 가이드라인 -스카이라이프의 스카이터치 서비스를 중심으로 -)

  • Goo, Min-Jung;Lee, Tae-Il
    • Archives of design research
    • /
    • v.20 no.3 s.71
    • /
    • pp.129-140
    • /
    • 2007
  • This study attempts to investigate the personalized schemes of interface for the interactive TV sonics enhancing the satisfaction of users from the standpoints of the user and to suggest designing guidelines. In the preface, firstly, the purpose as well as structure of the study were described, the characteristics of the interactive TV and the personalization were defined. Also, it was attempted to understand the development directions of the basic media for services. In addition, the data and elements that became the ground for this study were arranged, including the elements for designing interface, the appraisal method of usability to evaluate the requirements of users, etc. Then, the interfaces of "SkyTouch", an interactive TV sonics by Skylife having the number of users reaching one million at the moment, that is the representative runner in the interactive TV, were analyzed. Then the needs central to the navigation structure and layout for the convenience of users through the evaluation of usability were examined and arranged. In addition, the designing directions of personalized interfaces were studied in the interactive TV by analyzing the web portal sites which were being carried out prior to the personalized services. Based on the data investigated and analyzed previously, the guidelines for the interface design for the personalization of the interactive TV were suggested by classifying the navigation structure and layout, and the personalized interface design was proposed according to the suggested guidelines by applying them directly to "SkyTouch" that is currently carrying out the interactive sonics although it provides limited services in an independent style.

  • PDF