• 제목/요약/키워드: LiCl Aqueous solution

검색결과 26건 처리시간 0.022초

판형 열교환기식 제습기에서 LiCl 수용액의 열 및 물질전달 특성 (Heat and Mass Transfer Characteristics of LiCl Aqueous Solution for a Plate Heat Exchanger Type Dehumidifier)

  • 전동순;이해승;김선창;김영률
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.16-22
    • /
    • 2012
  • Experimental investigations were carried out to examine the heat and mass transfer characteristics of LiCl aqueous solution for a plate heat exchanger type dehumidifier. Cooling dehumidification was adopted vertical type heat exchanger. Also non woven fabric is attached surface of the heat exchanger for spreadability of LiCl aqueous solution. Mass flow-rate of LiCl aqueous solution and concentration were selected as experimental conditions. Also, In this study, the effects of relative humidity of process air and velocity were investigated experimentally. As a result of heat transfer coefficient and mass transfer coefficient of were increased film reynolds number increased. heat transfer coefficient and mass transfer coefficient of LiCl aqueous solution were 0.14~0.24 kW/$m2^{\circ}C$ and $1.3{\times}10-63{\sim}6.2{\times}10-6$ m/s respectively.

작동매체에 따른 2중효용 흡수식 시스템의 성능해석 (Thermodynamic Analysis of Double-effect Absorption Heat Pump System with New Working Pairs)

  • 원승호;이영수
    • 설비공학논문집
    • /
    • 제3권4호
    • /
    • pp.250-255
    • /
    • 1991
  • Performance analysis of double-effect absorption heat pump system has been done to find improved working pairs (or mixture) by computer simulation. Based on the thermodynamic analysis, the coefficient of performance and mass flow ratio are investigated to compare three aqueous solutions [LiCl-water, LiSCN-LiBr-water, LiCl-$CaCl_2$-$Zn(NO_3)_2$-water] which was developed for only cooling, with conventional LiBr-water solution. It is found that the performances of the new aqueous solutions are better than that of LiBr-water solution not only in cooling systems, but also in heating systems. Theoretical thermodynamic performance data can be used in heat recovery systems by basic design data.

  • PDF

Experimental study of correlation between aqueous lithium chloride-air temperature difference and mass transfer performance

  • Fatkhur, Rokhmaw;Agung, Bakhtiar;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.195-198
    • /
    • 2011
  • Liquid desiccant material, such as lithium chloride (LiCl) or halide slits are usually used on air conditioning application for controlling the humidity of high Outdoor Air (OA). Solar energy is usually used to heat the liquid in regeneration process of those desiccant. The mass transfer it self is driven by the temperature different between the liquid desiccant and the input air. This experiment study is analyzing the characteristic of the aqueous LiCl-air temperature different in variance specific gravity, especially in range of temperature different using the solar energy as the heat generator. The experiment has done by variating the concentration of the LiCl with specific gravity 1.210 and 1.150. For the comparison the pure water is also used. The result show that the mass transfer rate is increased in every variation as the increases of the temperature different, and the weeker aqueous solution of the LiCl the highest mass transfer coefficient.

  • PDF

1, 2종 흡수식 히트펌프의 작동 매체에 따른 성능 해석[I] (Thermodynamic Analysis of an Absorption Heat Pump System with New Working Pairs[I])

  • 원승호;이원용;정헌생
    • 설비공학논문집
    • /
    • 제1권3호
    • /
    • pp.219-227
    • /
    • 1989
  • Performance analysis of an absorption heat pump system for solar energy recovery has been done by computer simulation to find improved working pairs. Based on the thermodynamic analysis, the coefficient of performance and mass flow ratio have been calculated to compare two aqueous solutions [LiCl-water, $LiCi-CaCl_2-Zn(NO_3)_2$-water] which were developed for cooling by others, with the conventional LiBr-water solution. As a result of this analysis, the performances of the new aqueous solutions were found to be better than that of LiBr-water solution not only in cooling systems, but also in heating and in heat transformer systems. Their theoretical thermodynamic performance data were given here with.

  • PDF

리튬이온이 첨가된 프루시안 블루의 전기변색 특성 연구 (Electrochromic Properties of Li+-Modified Prussian Blue)

  • 유성종;임주완;박선하;원호연;성영은
    • 전기화학회지
    • /
    • 제10권2호
    • /
    • pp.126-131
    • /
    • 2007
  • [ $Li_+$ ]를 기반으로 하는 비수용액 전해질에서 Prussian blue가 degradation이 없이 구동할 수 있도록 소재를 design하고 제조하여 전기화학적 변색특성을 연구하였다. Prussian blue는 ITO가 코팅되어 있는 유리판위에 일정전류-전착법으로 코팅을 했고, 이 때 사용된 코팅 용액은 $FeCl_3,\;K_3Fe(CN)_6$을 deionized water에 녹이고, HCl, KCl, LiCl을 각각 넣었다. 전기화학적 변색특성을 비교하기 위해 continuous와 pulse potential cycle 하는 동안 transmittance 변화를 in-situ He-Ne laser를 이용하여 측정하였고, electroactive layer thickness를 통해 degradation된 정도를 실험하였다.

액체 제습식 냉방 사이클의 최적화 (Optimization of Liquid Desiccant Cooling Cycle)

  • 김선창;김영률;이상재;전동순;최장현;권혁민;이창준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.673-678
    • /
    • 2009
  • This paper presents the optimization process of liquid desiccant cooling cycle using LiCl aqueous solution as a working fluid. Operating conditions and design factors for heat exchangers were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of $dT_{hw}$ on system performances was also examined. As $dT_{hw}$ increases, the cooling capacity increases and COP decreases.

  • PDF

액체 제습식 냉방 시스템의 최적 설계 (Optimization Design of Liquid Desiccant Cooling System)

  • 전동순;이상재;김선창;김영률;이창준
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.419-428
    • /
    • 2010
  • This paper presents the optimization process of liquid desiccant cooling system using LiCl aqueous solution as a working fluid. Operating conditions(mass flow rate, conditioner outlet concentration, difference concentration) and design factors for heat exchangers(difference temperature of the district heating water, leaving temperature difference of the conditioner, leaving temperature difference of the regenerator, air temperature difference of the conditioner, air temperature difference of the regenerator) were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of difference temperature of hot water on system performances was also examined. As difference temperature of the district heating water increases, the cooling capacity increases and COP decreases.

Electrochemical and Spectrofluorometric Behaviors of Eu(III) Complexes in Aqueous Solution

  • Chae Won-Seok;Kim Kang-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권12호
    • /
    • pp.1050-1054
    • /
    • 1994
  • Eu(Ⅲ) exhibits one electron-transfer reduction at E$_{1/2}$ =-0.617 V vs. Ag/AgCl and the hypersensitive peak at 618 nm corresponding to $^5D_0$ ${\leftrightarro}$ $^7F_2$ transition in 0.10 M LiClO$_4$ aqueous solutions. Upon the addition of carboxylate or sulfonate anions to the Eu(Ⅲ) aqueous solutions, the reduction potential shifts negatively and the reduction current decreases because of the complex formation between Eu(Ⅲ) ions and the anions. However, for the case of carboxylate anion (acetate or propionate) the shift of reduction peak potential and the emission intensity at 618 nm are greater. The results are interpreted in terms of the differences in the formation constants and the hypersensitivity.

Corrosion behavior induced by LiCl-KCl in type 304 and 316 stainless steel and copper at low temperature

  • Sim, Jee-Hyung;Kim, Yong-Soo;Cho, Il-Je
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.769-775
    • /
    • 2017
  • The corrosion behavior of stainless steel (304 and 316 type) and copper induced by LiCl-KCl at low temperatures in the presence of sufficient oxygen and moisture was investigated through a series of experiments (at $30^{\circ}C$, $40^{\circ}C$, $60^{\circ}C$, and $80^{\circ}C$ for 24 hours, 48 hours, 72 hours, and 96 hours). The specimens not coated on one side with an aqueous solution saturated with LiCl-KCl experienced no corrosion at any temperature, not even when the test duration exceeded 96 hours. Stainless steel exposed to LiCl-KCl experienced almost no corrosion below $40^{\circ}C$, but pitting corrosion was observed at temperatures above $60^{\circ}C$. As the duration of the experiment was increased, the rate of corrosion accelerated in proportion to the temperature. The 316 type stainless steel exhibited better corrosion resistance than did the 304 type. In the case of copper, the rate of corrosion accelerated in proportion to the duration and temperature but, unlike the case of stainless steel, the corrosion was more general. As a result, the extent of copper corrosion was about three times that of stainless steel.

Eu(III)-Pyridine Dicarboxylic Acid 착물에 관한 전기화학적 거동 및 형광분광학적 연구 (Electrochemical and Spectrofluorometric Studies of Europium(III)-Pyridine Dicarboxylic Acid Complexes)

  • 김용렬;채원석
    • 한국응용과학기술학회지
    • /
    • 제18권1호
    • /
    • pp.12-19
    • /
    • 2001
  • Eu(III) exhibits one electron-transfer reduction at $E_{1/2}$ = -0.564 V(vs. Ag/AgCl) and the hypersensitive peak at 615 ㎚ corresponding to $^{5}D_{0}{\rightarrow}^{7}F_{2}$ transition in 0.1 M $LiClO_{4}$ aqueous solution. Upon the addition of 2,6-pyridine dicarboxylic acid(PDA) to the Eu(III) aqueous soultion, the reduction potential shifts negatively and the PDA, and the Eu(III)-PDA complex emits great fluorescence than free-Eu(III) ion at 615 nm. The results are interpreted in term of the electrochemical and spectrofluorometric studies.