• Title/Summary/Keyword: Level Variation

Search Result 3,096, Processing Time 0.033 seconds

Compensation of low Frequency Resonance in Current Driven Loudspeakers using DSP (DSP를 이용한 전류구동 스피커의 저주파 공진 보상)

  • Park, Jong-phil;Eun, Changsoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.584-588
    • /
    • 2021
  • The impedance of the speaker is likely to be recognized as a fixed value. However, speaker impedance continues to vary with frequency variation, especially larger in resonant frequency region. The sound pressure level of loudspeakers is determined by the current flowing throughout the coil that consists loudspeakers. If loudspeakers are driven by voltage, sound pressure level of the loudspeaker is distorted by the variation of loudspeaker impedance. Current-drive of loudspeakers can solve this problem, but distortion of sound pressure level occurs in low frequencies due to resonance. The distortion can degrade the sound quality of the sound system. So to solve this problem, In this paper, we propose a resonance compensation circuit using DSP. we simulates audio systems using an equivalent model of loudspeakers to verify distortion of sound pressure level due to impedance variation and propose a circuit to compensate it. The proposed circuit is configured using a state variable filter and it can adjust the center frequency and output, so it will be used various sound systems.

  • PDF

Intrusion detection based on the sound field variation of audible frequency band (가청 주파수대 음장 변화 측정 기반 침입 감지 기술)

  • Lee, Sung-Q.;Park, Kang-Ho;Yang, Woo-Seok;Kim, Jong-Dae;Kim, Dae-Sung;Kim, Ki-Hyun;Wang, Se-Myung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.187-192
    • /
    • 2010
  • In this paper, intrusion detection technique based on the sound field variation of audio frequency in the security space is proposed. The sound field formed by sound source can be detected with the microphone when the obstacle or intruder is positioned. The sound field variation due to the intruder is based on the interference of audio wave. With the help of numerical simulation of sound field formations, the increase or decrease of sound pressure level is analyzed not only the obstacle, but also the intruder. Even the microphone is positioned behind the source, sound pressure level can be increase or decrease due to the interference. Frequency response test is performed with Gaussian white noise signal to get the whole frequency response from 0 to half of sampling frequency. There are three security cases. Case 1 is the situation of empty space with and without intruder, case 2 is the situation of blocking obstacle with and without intruder, and case 3 is the situation of side blocking obstacle with and without intruder. At each case, the frequency response is obtained first at the security space without intruder, and second with intruder. From the experiment, intruder size of $50cm{\times}50cm$ can be successfully detected with the proposed technique. Moreover, the case 2 or case 3 bring about bigger sound field variation. It means that the proposed technique have the potential of more credible security sensing in real situation.

  • PDF

A Study on the Compensating System for the Acoustic Characteristics Caused by the Variation of Distance from Sound Source to Microphone (음원과 마이크로폰 사이의 거리변화에 의한 음향 특성 보정에 관한 연구)

  • Jeoung, Byung-Chul;Choe, Yoon-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.197-204
    • /
    • 2012
  • In this thesis, studied the method to minimize the changes in frequency response and level due to the variation of the distance from the source to the microphone. selecting three microphones (omni directional, cardioid, super cardioid) which are being used generally, frequency responses were measured in accordance with the distance changes. Gotten the difference from the reference as the result of measurement, changed responses for each frequency range were compensated in comparison of the original human vocal source. In low frequency range, the low frequency boost caused by the proximity effect and decrease in accordance with the distance were compensated. The variation in mid-frequency range is comparatively small, however since the mid-range is the most important part of the human vocal signal, were compensated the mid-frequency range in comparison of the reference. The human vocal signal variation in high frequency range is extremely small and the high frequency is compensated close to the original source without difficulty. Understanding the microphone characteristics and compensations, this study showed that the response can be maintain among the change of the distance from the source to the microphone.

Intrusion Detection Based on the Sound Field Variation of Audible Frequency Band (가청 주파수대 음장 변화 측정 기반 침입 감지 기술)

  • Lee, Sung-Q;Park, Kang-Ho;Yang, Woo-Seok;Kim, Jong-Dae;Kim, Dae-Sung;Kim, Ki-Hyun;Wang, Se-Myung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.3
    • /
    • pp.212-219
    • /
    • 2011
  • In this paper, intrusion detection technique based on the sound field variation of audio frequency in the security space is proposed. The sound field formed by sound source can be detected with the microphone when the obstacle or intruder is positioned. The sound field variation due to the intruder is mainly caused by the interference of audio wave. With the help of numerical simulation of sound field formations, the increase or decrease of sound pressure level is analyzed not only by the obstacle, but also by the intruder. Even the microphone is positioned behind the source, sound pressure level can be increased or decreased due to the interference of sound wave. Frequency response test is performed with Gaussian white noise signal to get the whole frequency response from 0 to half of sampling frequency. There are three security cases. Case 1 is the situation of empty space with and without intruder, case 2 is the situation of blocking obstacle with and without intruder, and case 3 is the situation of side blocking obstacle with and without intruder. At each case, the frequency response is obtained first at the security space without intruder, and second with intruder. From the experiment, intruder size of diameter of 50 cm pillar can be successfully detected with the proposed technique. Moreover, the case 2 and case 3 bring about bigger sound field variation. It means that the proposed technique have the potential of more credible security guarantee in real situation.

Studies on the Variation of Nonprotein Nitrogen Compounds in the Blood of Rabbits Administered with Panax ginseng -Mainly on the Variation of Ammonia Value in the Blood of Portal Vein- (인삼투여가토(人蔘投與家兎)의 혈액내(血液內) 비단백성질소함량(非蛋白性窒素含量)의 변화(變化)에 관한 연구(硏究) -문맥(門脈) 혈액(血液) 암모니아치(値)의 변화(變化)를 중심(中心)으로-)

  • Lee, Ju Mook
    • Korean Journal of Veterinary Research
    • /
    • v.18 no.2
    • /
    • pp.77-86
    • /
    • 1978
  • The present study was carried out to evaluate the effect of Panax ginseng on the metabolism of nonprotein nitrogen compounds in rabbit blood. After rabbits were administered with ginseng powder orally for 30 days or with ginseng extract intraperitoneally for 10 days, the blood was collected from portal and ear vein to measure ammonia, urea, creatinine and nonprotein nitrogen. The blood ammonia level in ear vein of control rabbits was $87.0{\pm}5.1{\mu}g/100ml$ and was not significantly different from that of rabbits which were administered with ginseng powder orally or with ginseng extract intraperitoneally. But oral administration of ginseng powder produced a great decrease in ammonia level of portal vein from 1,392 to $704{\mu}g$ per 100ml, suggesting that intestinal ammonia production is suppressed by ginseng powder due to its antimicrobial activity. While there was no significant difference between the control and the rabbits which were administered with ginseng extract intraperitoneally. Ginseng administration had no effect on the creatinine level in blood from ear and portal vein, except the intraperitoneal injection of ginseng extract. It slightly lowered the creatinine level only in ear vein blood. The values of urea and nonprotein nitrogen were net affected by the administration of ginseng.

  • PDF

An Experimental Study on the Performance of Inverter Heat Pump with a Variation of Frequency and Capillary Size

  • Choi, Jong-Min;Kim, Yong-Chan;Kim, Jong-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.27-35
    • /
    • 1998
  • An experimental study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4,141 W(3,550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of l,000mm(optimum size for the frequency of 60Hz) and ASHRAE Test condition "A" was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycles were investigated by varying the length of capillary tube at each frequency level of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency level. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher energy efficiency ratio(EER), while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

Compensating for the Neutral-Point Potential Variation in Three-Level Space-Vector PWM Method (3-레벨 인버터 공간벡터 변조시의 중성점 전위 변동 보상법)

  • Seo Jae Hyeong;Kim Kwang Seob;Bang Sang Seok;Choi Chang Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.475-478
    • /
    • 2001
  • In performing the three-level SVPWM, it is nearly impossible to control the neutral-point potential exactly to the half of the dc-link voltage at all times. Therefore the inverter would produce an erroneous output voltage by this voltage unbalance. So the voltage unbalance has to be compensated in doing PWM, when the voltage unbalance occurs whether it is small or large, to make the inverter output voltage follow the reference voltage exactly the same. In this paper, a new compensating method for the neutral-point potential variation in a three-level inverter space vector PWM (SVPWM) is presented. By using the proposed method, the output voltage of the inverter can be made same as the reference voltage and thus the current and torque ripple of the inverter driven motor can be greatly improved even if the voltage unbalance is quite large. The proposed method is verified experimentally with a 3-level IGBT inverter.

  • PDF

Analysis of Fault Current Limiting Characteristics According to Variation of Fault Current level in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (사고전류 변화에 따른 일체화된 삼상자속구속형 고온초전도 사고전류제한기의 사고전류 제한 특성 분석)

  • Han, Byoung-Sung;Park, Chung-Ryul;Du, Ho-Ik;Choi, Hyo-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.39-40
    • /
    • 2007
  • The analysis of fault current limiting characteristics according to variation of fault current level in the integrated three-phase flux-lock type superconducting fault current limiter (SFCL), which consisted of three-phase flux-lock reactor wound on an iron core with the same turn's ratio between coil 1 and coil 2 for each single phase, was performed. To analyze the current limiting characteristics of this integrated three-phase flux-lock type SFCL, the short circuit experiments was carried out the various three-phase faults such as the single line-to-ground fault, the double line-to-ground fault, the triple line-to-ground fault. From the experimental results, the fault current limiting characteristic was improved according to increase of fault current level.

  • PDF

Community-level facilitation by macroalgal foundation species peaks at an intermediate level of environmental stress

  • Scrosati, Ricardo A.
    • ALGAE
    • /
    • v.32 no.1
    • /
    • pp.41-46
    • /
    • 2017
  • In rocky intertidal habitats, abiotic stress due to desiccation and thermal extremes increases with elevation because of tides. A study in Atlantic Canada showed that, at low elevations where conditions are benign due to the brief low tides, fucoid algal canopies (Ascophyllum nodosum and Fucus spp.) do not affect the structure of benthic communities. However, at middle and high elevations, where low tides last longer, fucoid canopies limit abiotic extremes and increase the richness (number of invertebrate and algal species, except fucoids) of benthic communities. Using the data from that study, this paper compares the intensity of facilitation and its importance (relative to all other sources of variation in richness) between middle and high elevations, which represent intermediate and high stress, respectively. Facilitation intensity was calculated as the percent increase in benthic richness between quadrats with low and high canopy cover, while the importance of facilitation was calculated as the percentage of variation in richness explained by canopy cover. Data for 689 quadrats spanning 350 km of coastline were used. Both the intensity and importance of facilitation were greater at middle elevations than at high elevations. As canopies do not affect benthic communities at low elevations, this study suggests that the facilitation-stress relationship at the community level is unimodal for this marine system. Such a pattern was found for some terrestrial systems dominated by canopy-forming plants. Thus, it might be ubiquitous in nature and, as further studies refine it, it might help to predict community-level facilitation depending on environmental stress.

Variation of Corrosion Properties on the Steel Surface by Environmental Changes in Shihwa Lake (시화호 환경 변화에 따른 강재 표면의 부식특성 변화)

  • Park, Jun-Mu;Lee, Seung-Hyo;Woo, Sang-Kyun;Chu, In-Yeop;Lee, Myeong-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.5
    • /
    • pp.316-324
    • /
    • 2018
  • Harsh seawater environment is subdivided into marine atmosphere, splash zone, tidal zone, submerged zone and bottom of sea depending on the exposed part. Since corrosion rate depends on the conditions of the exposed parts, proper protection and maintenance for each parts are essential for long-term use of steel structures in seawater environment. For steel structures which were installed in Shiwha Lake, a special maintenance system is required to guarantee its long-term durability and safety. As the tidal power plant has recently been operated, the salinity has risen due to the rapid influx of seawater upstream into Sihwa Lake and the corrosion tendency of the structure is variable according to the water level fluctuation. In this study, corrosion properties of steel structures under water level fluctuation was evaluated by corrosion rate measurement, visual inspection and natural potential measurement and their durability and life management were discussed in view of the effect of variation in of seawater level fluctuations in Shihwa Lake.