Kim, So Ra;Park, Sang Hee;Joo, Seon-Ok;Lee, Hye Rim;Park, Mijung
Journal of Korean Ophthalmic Optics Society
/
v.17
no.1
/
pp.27-35
/
2012
Purpose: The present study was conducted to compare any difference caused by pigmentation in the centrations and movement patterns on the cornea between circle and soft contact lens with identical material and parameters during lens wearing. Methods: Soft and circle contact lenses with identical material and parameters were applied to twenty eyes with normal tear volume for 3 hrs a day during a total of 5 days and then their lens centrations, the moving distances and rotations by repeat blinking were compared. Results: The lens centration beyond the fitting criteria was shown in initial wears of both soft contact lens and circle contact lens. However, the centration of soft contact lens was changed to the pupil center for being suitable to the fitting criteria with longer wearing time. On the other hand, the decentration of circle contact lens in the horizontal direction was still presented even with longer wearing time. The moving distances of soft contact lens and circle contact lens decreased with the expand of lens wearing but were not significantly different between total wearing period and daily wearing time. The rotation of circle contact lens by repeat blinking was significantly different from that of soft contact lens even when the wearing period was extended. Conclusions: We revealed that the lens centration and movement of circle contact lens on cornea were different from those of regular soft contact lens resulting in bigger difference with the expand of wearing period in the study.
Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
Journal of Korean Ophthalmic Optics Society
/
v.18
no.4
/
pp.429-439
/
2013
Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.
Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
Journal of Korean Ophthalmic Optics Society
/
v.19
no.1
/
pp.31-42
/
2014
Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.
Kim, Bong-Hwan;Han, Sun-Hee;Kim, Hak-Jun;Bae, Sang-A;Son, Yu-Jin;Kim, Ji-Hyun;KIm, Hyun-Ji
Journal of Korean Clinical Health Science
/
v.7
no.1
/
pp.1232-1237
/
2019
Purpose. In this study, two types of soft contact lenses with different materials were selected to compare the time of tear film destruction and high order aberrations before and after wearing. Methods. Thirty patients (60 eyes) in their 20s were included in this study. Two lenses with different materials, Group 4 (Etafilcon A) and Group 5 (Narafilcon A) were selected. Using aberration analyzer and keratometry, high-order aberration and tear film test (NIF-BUT, NIAvg-BUT) were performed before and after wearing. Results. When comparing the higher aberrations of the Etafilcon A and Narafilcon A lenses, the higher aberrations of the Narafilcon A lens were higher overall. For the initial tear film break-up time (NIF-BUT) after wearing, the Etafilcon A lens was reduced by 4.0 seconds and the Narafilcon A lens increased by 0.6 seconds. For the mean tear film break-up time (NIAvg-BUT) after wearing, the Etafilcon A lens decreased by 2.4 seconds and the Narafilcon A lens increased by 1.7 seconds. Conclusions. NIF-BUT and NIAvg-BUT of Narafilcon A lens were increased. The lens with relatively low water content and higher oxygen permeability than the lens with high water content has relatively less tear evaporation, which means that the time of destruction of the tear film is increased.
Purpose: The present study was conducted to investigate the actual condition of circle lens wear and the differences caused by the pigmentation in blinking rate, non-invasive tear break-up time (NIBUT), and lens surface between circle and soft contact lens wear during clinical application. Methods: Eighty subjects were surveyed to know the actual condition of wearing circle lens. Blink rate, NIBUT of 20 subjects in twenties were measured after separately wearing soft contact lens and circle lens for 5 days. Their lens surfaces were also observed by scanning electron microscope. Results: Fifty percent of circle lens wearers answered that major reason for changing circle lens was discomfort and 67% of answerers wore circle lens more than 6 hours a day. The tendency of increased blink rates in both wearers of circle and soft contact lens at 30 minutes later when tear film stabilized and 3 hour after lens wearing was shown on the 1st, 3rd and 5th day with expanding wearing time. Especially at 3 hours after lens wearing on the 3rd and 5th day, the difference of blink rates was statistically different in circle lens wear and soft contact lens wear. The NIBUTs of soft contact lens wearers and circle lens wearers were 6.0 and 3.7 secs, respectively, at 30 min later on 1st day and were significantly different. NIBUTs of soft contact lens wearers and circle lens wearers were also statistically different 3 hrs after lens wearing on the 1st day and the similar pattern of NIBUTs was shown on the 3rd and 5th day. The roughness of both surfaces in soft contact lens and front surface in circle lens was same. However, pigmented front surface of circle lens was rougher and uneven. Conclusions: As the results, the circle lens wearers might feel discomfort in clinical application since the difference in lens surface of circle lens would change lens wettability during wearing. The difference by tinting contact lens was shown from the result, which could help better wearing circle lens.
Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
Journal of Korean Ophthalmic Optics Society
/
v.19
no.2
/
pp.153-162
/
2014
Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.
Purpose: The aim of this study was to analyze the difference in tear film stability according to the wearing time when wearing clear and circle soft contact lens(circle lens) made of same material. Methods: The clear and circle contact lenses of hilafilcon B and nelfilcon A materials were respectively applied on the subjects classified as normal and dry eyes depending on their tear volume, and their tear film stability was investigated by measuring the non-invasive tear film break-up times, lens centration and the first appearing area of tear breakup after 30 mins and 6 hrs of lens wearing. Results: Non-invasive tear film breakup time significantly reduced with increase of the wearing time for normal and dry eyes when wearing clear and circle contact lenses. The starting ratio of tear film break-up was higher at the peripheral area of clear and circle lenses in all two different materials, and higher at the peripheral area of dry eyes than normal eyes. Starting ratio of tear film break-up was higher at the peripheral area of nelfilcon A lenses compared with hilafilcon B lenses, however, its change with the increase of wearing time showed a different aspect. The number of tear film break-up per unit area when wearing circle lenses of nelfilcon A increased at the central area with the wearing time while its number was higher at the peripheral area when wearing circle lenses of hilafilcon B. The centration of clear lenses made of two materials was closer to pupil compared to circle lenses with the increase of wearing time, however, a larger decentration was shown in dry eyes compared with normal eyes. Conclusions: The research revealed that an effect on tear film stability may be changed by clear lenses as well as circle lenses with coloring process according to the increase of wearing time, and the factors affecting on tear film stability may also vary depending on lens materials. Thus, the appropriate lenses should be selected by the consideration of lens material as well as coloring method/dyes according to the wearers' habit such as daily wearing time and wearing period when trying to wear clear and circle lenses.
Kim, Ki-Sung;Kim, Sun-Kyung;Kim, Tae-Hun;Kim, Hyo-Jin
Journal of Korean Ophthalmic Optics Society
/
v.20
no.2
/
pp.151-156
/
2015
Purpose: This study has been compared the degree of corneal edema arising from the material of the lens after wearing the recommended wearing time for the contact lens. Methods: For the study, 43 adults of 77 eyes who did not use drugs and have not any disease participated. Three types of lenses including narafilcon A, HEMA, and silicone hydrogel material regular replaceable lenses were used. Central corneal thickness was measured before and after 8 hours from wearing lenses using Pentacam. The degree of corneal edema was determined by the difference before and after wearing. Results: The average corneal edema of narafilcon A, HEMA material lens, and silicone hydrogel material regular replaceable lens were $2.36{\pm}6.15{\mu}m(Mean{\pm}SD)$, $23.61{\pm}10.71{\mu}m$, $18.25{\pm}8.64{\mu}m$, respectively. The central corneal thickness after wearing narafilcon A was not statistically significant with the central corneal thickness before wearing the lens. Central corneal thickness before and after wearing HEMA material lens and silicone hydrogel material regular replaceable lens were statistically significant. Conclusions: The amount of corneal edema induced by silicone hydrogel material regular replaceable lens was no statistically significant difference to the amount of corneal edema induced by HEMA material lens, but there was significant difference to narafilcon A. Therefore, it is judged to be careful not to exceed the recommended wearing time depending on the composition of the contact lens material.
Purpose: The study was performed to compare the difference of non-invasive tear break-up time (NIBUT) with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified to the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment or steep fitting. NIBUTs of lens wearers were separately measured at the points of before wearing, immediately after wearing and after stabilization of tear film. Results: With alignment fitting, averaged NIBUT in the dry eye group after stabilization of tear film was not significantly different from that of the normal eye group. However, averaged NIBUTs in the normal and dry eyes had significant difference when measured immediately after lens wearing. However, the number of eyes having NIBUT less than 4.0 second was 30% higher compared to the number of normal eyes with steep fitting when measured immediately after wearing. Some shorten NIBUT in dry eyes with steep fitting was also shown after stabilization of tear film. Conclusions: These results suggest that wearing soft contact lens in dry eyes differently affect tear film compared to normal eyes. Thus, dry eyes need more advertent fitting for contact lens wearing because of unstable tear film.
Purpose: To evaluate the changes of refractive power when worn soft contact lenses were temporarily removed. Methods: 91 soft contact lens wearers (15 males and 76 females; total 182 eyes) from 17 to 39 years of age (average: $24{\pm}4.8$ years) were participated. Objective and subjective refraction, and corneal radius were measured at 0, 30, 60 and 90 min after lens removal. The changes in refractive power were evaluated between measurements over time. The other parameters such as types of lenses, fitting and wearing conditions were also assessed. Results: Objective refraction, subjective refraction and corneal radius were significantly changed according to measured time (p<0.0001). A moderate myopic shifts was observed at the beginning (30 min after lens removal) and a slight myopic shift at the late of measurement (60 min to 90 min after lens removal). There are no significant differences between lens types, fitting states, wearing time, wearing days and sleeping time in the previous day. However, there was significant interaction in changes for corneal radius between measuring time and lens type (p=0.017), fitting state (p=0.019), and sleeping time prior to the test (p=0.010). Conclusions: Time to reach refractive and corneal radius stability after contact lens removal revealed at least more than 60 min, regardless of types of lenses, fitting and wearing conditions. Therefore, refraction for correction should be performed after waiting for more than that time as possible.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.