• Title/Summary/Keyword: Lens eccentricity

Search Result 21, Processing Time 0.026 seconds

Correlations between Axial Rotation of Toric Soft Contact Lenses and Corneal Eccentricity according to the Wearing Time and Gaze Directions (착용시간 및 응시방향에 따른 토릭소프트콘택트렌즈의 축 회전과 각막이심률과의 상관관계)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • Purpose: The present study was aimed to investigate the effect of corneal eccentricity on the axial rotation when wearing toric soft contact lenses were worn for certain time and changing the gaze directions. Methods: Toric soft contact lenses with double thin zone design applied on 85 of with-the-rule astigmatic eyes. Then, rotational direction and amount of contact lenses were measured after 15 minutes and 6 hours of lens wear. The difference was further compared and analyzed according to corneal eccentricity. Results: The rotation of toric lens showed a tendency to rotate to temporal direction in all gaze directions except temporal-upper direction in all groups of corneal eccentricity. The amount of lens rotation in the frontal gaze direction exhibited a negative correlation since the amount was decreased with increasing corneal eccentricity after both 15 minutes and 6 hours of lens wearing. In many cases, the cornea with small eccentricity also showed the lens rotation larger than $10^{\circ}$. The difference in rotational amount after 15 minutes of toric lens wear was small according to the corneal eccentricity however, the change of rotational amount of contact lens according to corneal eccentricity was shown after 6 hours of lens wear. Conclusions: The present study revealed that the amount of axial rotation was largely varied according to the wearer's corneal eccentricity when wearing toric lens and the rotational amount after certain time of lens was also affected by corneal eccentricity. Thus, it is suggested that the selection of toric soft contact lenses based on corneal eccentricity is necessary.

A Relationship between Corneal Eccentricity and Stable Centration of RGP Lens on Cornea (각막 이심률과 RGP 렌즈의 중심안정위치와의 상관관계)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.373-380
    • /
    • 2012
  • Purpose: The present study was performed to investigate a relationship between the stable centrations of spherical RGP lens and aspherical RGP lens on cornea and corneal eccentricity. Methods: Two RGP lenses with different designs were fitted in alignment, steep or flat on total 84 eyes having corneal eccentricity of 0.28~0.78. The stable centration of lenses on cornea was analyzed by taking photographs with a high-speed digital camera. Results: The stable centrations of spherical and aspherical RGP lenses in horizontal direction were decentrated to temporal side. More centration to median side was shown when corneal eccentricity was larger. The difference between the stable centrations of spherical and aspheric RGP lenses according to corneal eccentricity was bigger when the fitting state was flatter. The difference in the stable centrations of aspherical RGP lens was smaller than that of spherical RGP lens regardless of fitting status. The stable centrations of spherical and aspherical RGP lenses in vertical direction were located below corneal apex regardless of fitting status however, there was no significant difference analyzed by the variation of corneal eccentricity. However, there were many cases that RGP lenses were in upper eyelid with increasing corneal eccentricity. Conclusions: The consideration of corneal eccentricity is required for RGP lens fitting and manufacturing aspherical RGP lens since the stable centration of spherical RGP lens as well as aspherical RPG lens' centration was changed depending on corneal eccentricity.

The Correlation Between Corneal Eccentricity and Radius Curvature by Fitting Status of Soft Contact Lens Wearer (소프트 콘택트렌즈 착용자의 피팅 상태에 따른 각막 이심률과 곡률반경과의 상관관계)

  • Han, Sun-Hee;Kim, Bong-hwan;Park, Jun-Sung;Baek, Su-won;Kwon, Sung Jin;Kim, Eun Kyoung;Yoon, Jung Na;Choi, So Min;Heo, A Jeong;Park, Eun Hye
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.662-670
    • /
    • 2016
  • Purpose. Because of a recent increase in use of soft contact lens at younger ages, in the present study, the correlation between corneal eccentricity and radius of curvature and fitting types of contact lens was investigated. Methods. The study evaluated the fitting status of targets through lens centration, push-up test, dynamic lag test and static lag test of lenses usually worn by 49 men and women (98eyes) in their 20s to 30s who put on soft contact lenses. After evaluation, the subjects were classified into 3 categories by fitting status(steep, aligment and flat). The radius of corneal curvature in the naked eyes was measured by using keratometer. Moreover the corneal eccentricity in the nasal side, temporal side, superior side and inferior side was measured by using the device capable of measuring the corneal eccentricity. Results. The radius of corneal curvature and corneal eccentricity of soft lenses worn by subjects were higher in the order of steep fitting and flat fitting, and the higher average corneal curvature radius and corneal eccentricity is intend to be more steep fitting(p=0.051, p=0.052). The corneal eccentricity showed a tendency to nasal fitting type at the higher eccentricity and temporal fitting type at the smaller eccentricity, statistically significant difference was observed(p<0.05). The study showed there were low correlation that nasal and temporal side at steep fitting, superior side at normal fitting and 4side(nasal, temporal, superior, inferior) at flat fitting, therefore when the corneal eccentricity changed the radius of corneal curvature also changed. The corneal eccentricity and the radius of corneal curvature showed statistically significant difference at 4side and each fitting types(p<0.05). Conclusions. The results of this study, the fitting status, of wearer are based on radius of corneal curvature and corneal eccentricity, and if lens fitting would be done considering that, it seems to be useful in a soft contact lens prescription.

LED Output Light Characteristic by Lens Eccentricity (LED Lens 의 이심률에 따른 출광 특성)

  • Kim, Young-Chul;Lyu, Jong-Sun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1170-1173
    • /
    • 2012
  • We have investigated the LED lens eccentricity effect on light intensity distribution. For the purpose, we introduced an equation of focal length for paraboloid, and then made a comparative analysis of the theoretical result and 3-D simulation result.

The Change in Corneal Eccentricity on the Correction of Refractive Error using Reverse Geometry Lens (역기하렌즈(Reverse Geometry Lens)의 굴절교정시 각막 편심률(Eccentricity)의 변화)

  • Lee, Seok-Ju;Park, Seong-Jong;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.145-150
    • /
    • 2010
  • Purpose: In this study we investigated the correlation between the effect of myopia correction and the change of corneal eccentricity using reverse geometry lens. Methods: The 23 students (46 eyes) continuously wearing reverse geometry lens during 3 months were divided into Group I and Group II by different parameter fitting methods of wearing Reverse Geometry Lens. We measured a corneal eccentricity for Group I and Group II at $10^{\circ}$, $20^{\circ}$, and $30^{\circ}$ positions from corneal apex before wearing reverse geometry lens, 1 week, 1 month, and 3 months after wearing reverse geometry lens. We also measured an uncorrected visual acuity, a spherical equivalent, and a corneal radius and analyzed the correlation between them and the change of corneal eccentricity using statistical significance test. Results: There were the statistical significances of a change of corneal eccentricity (p=0.03, t=-2.29) for Group I and Group II at 10 position from corneal apex in a week after wearing reverse geometry lens, but were not those (p>0.05) in 1 month, and 3 months after wearing reverse geometry lens. There were the statistical significances of correlation between the change of corneal eccentricity and a corrected visual acuity, and a corneal radius, respectively. Particularly, the high correlation between the change of corneal eccentricity and a corrected visual acuity (r=-0.36, p=0.00, t=6.5), and a spherical equivalent (r=-0.72, p=0.00, t=-70.5) for Group II in a week after wearing reverse geometry lens showed. Conclusions: We knew from these results that the high correlation between the effect of myopia correction and the change of corneal eccentricity in a week after wearing reverse geometry lens represented.

Tolerance Analysis Method of Camera Optics Using Floating System (플로팅 시스템이 적용된 카메라 광학계의 공차 분석)

  • Son, Hyun Jun;Ryu, Jae Myung;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.303-309
    • /
    • 2022
  • Since the pixel size of the image sensor used in optical systems is gradually decreasing, the resolution specification of the optical system should be inevitably higher. If aberration change according to the eccentricity of a specific lens group occurs, only the amount of eccentricity of a specific lens group may be calculated with the traditional resolution adjustment method so that the aberration of the optical system is minimized to a certain extent. As a result, it is possible to increase the resolution of the optical system and to respond to a sensor with a large number of pixels. However, in the traditional method, there should be no change in specific aberration due to the eccentricity of a specific lens group. In this paper, we propose a new method to eliminate such a limitation of the traditional method in a camera optical system with a floating system, which is to choose and control the arbitrary two lens groups to easily minimize the eccentricity of the optical system in order to obtain an optical system with high resolution.

The Effects of Corneal Eccentricity and Shape on Toric Soft Lens Rotation by Change of Postures (이심률 및 각막형상이 자세변화에 의한 토릭소프트렌즈의 회전에 미치는 영향)

  • Kim, So Ra;Hahn, Shin Woong;Song, Ji Soo;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.449-456
    • /
    • 2013
  • Purpose: The present study aimed to investigate the effects of corneal eccentricity and shape on the rotational pattern of toric soft lens by the postural change of lens wearers. Methods: The corneal eccentricity of 41 eyes (aged 20s) having -1.0 D with-the-rule corneal astigmatism (WRCA) was measured, and then toric soft lenses were fitted with the amount of total astigmatism. In lying and straight postures, the rotation of toric soft lenses was recorded by a camera attached to slitlamp and analyzed. Results: Most toric soft lens designed with accelerated stabilization rotated to the temporal direction, which was the lying position direction, regardless of corneal eccentricity, and some lenses rotated to the nasal direction for high corneal eccentricity and corneal type of asymmetric bowtie. There was no correlation between the amount of rotation and corneal eccentricity right after of contact lens wearing in straight and lying posture, however, the amount of rotation was the greater for the cornea with the higher eccentricity after the subjects laying down for some period. The speed of lens rotation started to decrease after the subjects laying down, but the speed was not different according to corneal eccentricity difference. The amount of lens rotation for symmetric and asymmetric bowtie-typed corneas increased more than it for oval-typed cornea, and it was same even with time elapsing. The speed of lens rotation in lying posture was the slowest in asymmetric bowtie-typed cornea compared with other corneal types. Conclusions: From the present study, it was revealed that the rotational pattern of toric soft lens was affected by corneal eccentricity and corneal shape when the wearer's posture changed. Thus, it should be considered for the development of the fitting guideline and the design of toric soft lens.

Design of the Finite Schematic Eye with GRIN Crystalline Lens Considering Iris Eccentricity (홍채 편심을 고려한 GRIN 수정체를 갖는 정밀모형안 설계)

  • Kim, Bong-Hwan;Han, Sun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.61-64
    • /
    • 2011
  • Purpose: The purpose of this study was to design the finite model eye with GRIN lens similar to actual eye, which considered the effect of iris eccentricity on eyes. Methods: By using the finite model eye with Radial GRIN and Spherical GRIN, which were designed previously, the location of iris was eccentrically located by 0.5 mm in the direction of nose to show the same eye as actual one. For ray trace and design, Code V program of Optical Research Associates (ORA) was adopted. Results: Designed model eye was compared to actual eye depending on iris eccentricity and the model eye which showed reduced value was corrected according to actual eye to design the finite model eye. Conclusions: Ocular optical systems considered the point that iris was a rotational asymmetry and designed the finite model eye with GRIN lens, which was similar to actual eye, by considering the effect of iris eccentricity on eye.

A Correlation between Axis-Rotation and Corneal Eccentricity in Toric Soft Contact Lens Fitting in With-the-rule Astigmatism (직난시안에서의 토릭소프트렌즈 피팅 시 축 회전과 각막이심률과의 상관관계)

  • Park, Hyung Min;Park, Kyounghee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.305-313
    • /
    • 2014
  • Purpose: A correlation between the rotating direction and rotation amount according to the eccentricity was analyzed in the present study when fitting the toric soft contact lens. Methods: One hundred fourteen eyes of with-the-rule astigmatism in 20s and 30s were appropriately applied toric soft contact lens by the guideline of manufacturer and fitting evaluations and analyzed the rotating direction and rotation amount when fixating at primary position and 8 different directions of gaze. The speed of reorientation and the correlation between the rotation amount and cornea eccentricity were also analyzed when rotating $45^{\circ}$ each toward the temporal and nasal direction. Results: The cornea eccentricity and rotation amount was shown positive correlation. For the gaze of direction, it was identified that the gaze of directions other than the gaze of direction towards the nasal and temporal had correlation, and among them, the gaze of directions to superior and the superior-temporal showed the tendency of decreasing rotation amount as the cornea eccentricity increased. On the contrary, the gaze of direction towards the inferior, inferior-temporal, superior-nasal, and inferior-nasal showed tendency of increasing rotation amount as the cornea eccentricity increased thus, it was identified that the cornea eccentricity showed different correlation according to the gaze of direction. For the case of re-orientational speed, the speed of lens reorientation in the group having the smallest corneal eccentricity was fastest in both direction but was not significantly different. Conclusions: Considering cornea eccentricity to current method of prescribing toric soft contact lens which is based on total astigmatism, it will be helpful to establish the optimal axis stabilization.

A Study on the Development and Performance Evaluations for a Self-diagnostication Ultra-precision Lens Polishing Machine (자기 진단형 초정밀 렌즈 폴리싱기의 개발 및 성능 평가에 관한 연구)

  • Park S.H.;Lim S.H.;Lee C.M.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.241-242
    • /
    • 2006
  • Spherical glass lenses are used in many optical industries. The curvature, eccentricity and height of a tool affect the surface roughness and curvature of lenses. The purpose of this study is the development and performance of a self-diagnostication ultra-precision lens polishing machine. In this paper, structure analysis is performed to reduce maximum displacement and to maintain outside the resonance region by CATIA V5. A spherical center setting gage is developed to increase accuracy of the manufactured lenses. The surface roughness, curvature and thickness of the manufactured lenses are measured and studied.

  • PDF