• Title/Summary/Keyword: Left hand

Search Result 772, Processing Time 0.038 seconds

The Archival Heritage in China : Preservation, Digitalization and Standardization (중국의 당안유산(檔案遺産) 보존과 디지털화 방향)

  • Feng, Huiling
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.5 no.2
    • /
    • pp.153-165
    • /
    • 2005
  • China is a country with a long history. Chinese culture dates back thousands of years ago. Thousand years of history left the huge quantity of archival heritage, which consists of the memory of China. From tied knots, tortoise shell, bronze, bamboo to paper, film, CD, the mankind's history is kept and continued through the evolution of the documenting media and documenting methods. In the information era, when we are immersed in the sea of information technologies, archivists, as guards of human's memory, have to look for a balance point between new and old, between unchanged and changed. On one hand, archivists should try their best to protect traditional archives in a usable, authentic way in a long term; on the other hand, they must face the challenges posed by electronic record. The information age is a stage of the social development of mankind, the digitalization of archives is an important progress of human history. The report mainly is composed of three parts of the content: first, introduce the preserving situation of Chinese archival heritage ; focus are put on "China archival heritage program" and the construction of "Special archives repository"; second, the process of digitalization of traditional archives; third, the framework of electronic record standard.

A Study on the Design of Wideband Microstrip Cross Slot Array Antennas with Circular Polarization (원편파용 광대역 마이크로스트립 크로스 슬롯 어레이 안테나의 설계에 관한 연구)

  • Min, Kyeoung-sik;Ko, Jee-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.4
    • /
    • pp.894-900
    • /
    • 2004
  • There are many types of circularly polarized(CP) microstrip antenna elements, which are used as a good unit radiator. Since an advantage of CP antenna is no strict alignment requirements between Rx and Tx system, the printed antennas with circular polarization are very often used in numerous satellite and mobile radio systems. In order to realize the broad bandwidth of 3 dB axial ratio and impedance of CP microstrip antenna, complex feed structure and tri-plate patch element have been researched. This paper describes a design of wideband microstrip cross slot array antennas with circular polarization. The proposed antenna is composed of an open-ended microstrip feed line as a feeder and a cross slot as a radiator for circular polarization. To realize the wide bandwidth, tri-plate structure are considered and cross slot is electromagnetically coupled with feed line. Optimum parameters of 1-element cross slot antenna are analyzed and designed by method of moments. These parameters are also applied to may antennas design considered the mutual coupling between radiating elements. Right hand circular polarization(RHCP) and left hand circular polarization(LHCP) of the proposed antenna are easily controlled by asymmetrical cross slot structure and slot position. In 1-element and 15-element cross slot array antenna, the good axial ratio of 1 dB below and the broad bandwidth characteristics of antenna are obtained.

Aristotle and Praxis (아리스토텔레스와 실천행위)

  • Jeon, Jae-won
    • Journal of Korean Philosophical Society
    • /
    • v.116
    • /
    • pp.371-387
    • /
    • 2010
  • On the one hand Aristotle seems to insist that practical acts are intrinsically good. On the other hand his doctrine of certain connected concepts is such that as a consequence practical acts must be considered good due to their being means to eudaimonia. This Aristotelian dilemma challenged by commenters. Cooper bases his attack on a consideration of Aristotle's account of deliberations. Deliberation is not just concerned with means in a strictly causal sense, but with things that contribute to the end. And these may also be constituent parts of complex ends or particular things that a given end may be seen to consist in. The difference between energeia and kinesis implies the distinction between praxis and poiesis. In kinesis such as 'building a house' and 'trying to save a child from drowning' we cannot sever, logically, 'the act' from the intended act-result, since no act will be left once that logical operation has been performed. The definition of poiesis relies on the possibility of such severance. But the fact that an act is kinesis has no implications whatever for the question whether it is a praxis or poiesis.

Assessment of NATM tunnel lining thickness and its behind state utilizing GPR survey (GPR탐사를 통한 NATM터널(무근)라이닝의 두께 분포 및 배면상태 평가)

  • Choo, Jin-Ho;Yoo, Chang-Kyoon;Oh, Young-Chul;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.717-733
    • /
    • 2019
  • In this study, lining thickness distribution and its behind state (particularly, its void state) were analyzed using the GPR survey data performed on three currently operating NATM tunnels. Results of GPR analysis showed that void areas were mostly detected between concrete lining and primary support, particularly, near the crown of the tunnels. The lining thickness in the left-hand side of the tunnel was different from that of the right-hand side by 8.6~253.5 mm when measured in transverse direction. It was also found that longitudinal cracks were prevailed in the area lining thickness was sharply changed. Longitudinal thickness distribution at the crown was also studied and tested by performing 3 goodness-of-fit tests in order to find the most suitable thickness distribution. Normal distribution (or similar distribution) fit most suitably to the measured data if the measured average thickness was larger than designed one; Gamma and/or Inverse Gauss distribution fit to the measured data reasonably well if the measured average thickness was less than the designed value of thickness. Since actual lining thickness can be a potential index when assessing the state and safety of the unreinforced NATM tunnel lining, measuring of the lining thickness with GPR survey might be needed rather than assuming the thickness is always constant and same with the designed value.

Effects of EMS Compression Belts with Different Muscular Patterns on Lumbar Stabilization (근육모양의 패턴을 달리한 EMS 복압벨트가 요추 안정화에 미치는 영향에 관한 연구)

  • Kim, Dae-Yeon;Park, Jin-hee;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.24 no.2
    • /
    • pp.81-92
    • /
    • 2021
  • In this study, we investigated the effects of five EMS lumbar back pressure belts produced on an anatomical basis on lumbar spine stabilization. Five core muscles were selected, including the urinal, vertebral column, endotracheal, external abdominal, and large back muscles, and patterns were designed using a conductive fabric considering the appropriate muscle shape and pain-causing points. We experimented with four motions to examine the effects of different EMS abdominal compression belts on lumbar spine stabilization. Five healthy men in their 20s were selected. The selection conditions include no back pain history for the past three months, no restricted movements through pre-inspection, and the muscular strength of the body should belong to the normal grade. Using SLR, the sequence of experimental actions was chosen from the following but not limited to left-hand, body-hand, and back-line forces. Resting between movements lasted for 2 min, and the experiments were conducted after wearing the EMS abdominal pressure belt. Electrical stimulation was applied for 10 min to increase blood flow and muscle activation. The statistics of the experimental results were analyzed for specific differences by conducting the Wilcoxon and Friedman tests with nonparametric tests. The ranking results of each pattern were successfully assessed in the order of 5, 4, 3, 1, 2 for the five patterns, and we could identify slightly more significant results for experimental behavior associated with each muscle movement. Patterns produced based on anatomy showed differentiated effects when electric stimulation was applied to each muscle in different shapes, which could improve the stabilization of the lumbar spine in everyday life or training to the public. Based on these results, subsequent research would focus on developing smart healthcare clothing that is practical in daily life by employing different anatomical mechanisms, depending on the back pain, to utilize trunk-type tights.

Effects of the Self-help Tai Chi Program for Arthritis with Supportive Follow up Phone-Calls (지지 전화를 이용한 자조타이치 프로그램 적용 효과)

  • Choi, Jung-Sook;Lee, Eun-Hee;So, Ae-Young;Lee, Kyung-Sook
    • Journal of muscle and joint health
    • /
    • v.16 no.2
    • /
    • pp.174-183
    • /
    • 2009
  • Purpose: The purposes of this study were to develop and examine the self-help and Tai Chi program for arthritis, and to identify the effect when combined with a supportive follow up phone-calls. Method: The design for this study was a 3*2 quasi-experimental design. Sixty-six participants were recruited in W-city, and assigned to Exp 1 group (n=21) or Exp 2 group (n=24) according to supportive follow-up phone call method, or to the control group (n=21). Fifty-two subjects (17 and 20 in Exp 1 and 2, and 15 in the control group) completed pretest and posttest. Both experimental groups participated in the self-help and Tai Chi program for arthritis once a week for 8 weeks. Exp 1 received automated follow up phone-calls made up in KT-SHUT program, and Exp 2 received follow up phone-calls made up by researchers. The control group received no education and no phone call. Measures used to examine the effect self-help and Tai Chi program for arthritis were joint flexibility, hand muscle strength, balance with closed eyes and self-efficacy. The final analysis of the post-test measures was conducted by ANCOVA with age and self efficacy as covariates. Results: Both experimental group had significantly increased right shoulder flexibility (p=.002), left shoulder flexibility (p=.000), right hand grip (p=.024), and self efficacy (p=.008) compared with the control group. But there were no significant differences between two experimental groups in any physical indicators and self efficacy. Conclusion: Automated follow up phone-call would be helpful in managing the self-help and Tai Chi program for arthritis as well as researcher's phone call. The automated follow up phone-call program which was a new method could be recommended for use to encourage home exercise practice and the program participation.

Smartphone Fundus Photography in an Infant with Abusive Head Trauma (학대뇌손상 영아에서 스마트폰으로 촬영한 안저소견)

  • Kim, Yong Hyun;Choi, Shin Young;Lee, Ji Sook;Yoon, Soo Han;Chung, Seung Ah
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.11
    • /
    • pp.1313-1316
    • /
    • 2017
  • Purpose: To report fundus photography using a smartphone in an infant with abusive head trauma. Case summary: An 8-month-old male infant presented to the emergency room with decreased consciousness and epileptic seizures that the parents attributed to a fall from a chair. He had no external wounds or fractures to the skull or elsewhere. However, computerized tomography of the brain revealed an acute subdural hematoma in the right cranial convexity and diffuse cerebral edema, leading to a midline shift to the left and effacement of the right lateral ventricle and basal cistern. The attending neurosurgeon promptly administered a decompressive craniectomy. Immediately after the emergency surgery, a fundus examination revealed numerous multi-layered retinal hemorrhages in the posterior pole extending to the periphery in each eye. He also had white retinal ridges with cherry hemorrhages in both eyes. We acquired retinal photographs using the native camera of a smartphone in video mode. The photographer held the smartphone with one hand, facing the patient's eye at 15-20 cm, and held a 20 diopter condensing lens at 5 cm from the eye in the other hand. Our documentation using a smartphone led to a diagnosis of abusive head trauma and to obtain the criminal's confession, because the findings were specific for repetitive acceleration-deceleration forces to an infant's eye with a strong vitreoretinal attachment. Conclusions: This ophthalmic finding had a key role in the diagnosis of abusive head trauma. This case presented the diagnostic use of a smartphone for fundus photography in this important medicolegal case.

A Real Situation Experimental Study on The Thermal Protection Performance of Firefighter Clothes and Gloves (소방방화복 및 소방장갑의 열 보호 성능에 대한 실제 화재 실험 연구)

  • Lee, Won Jae;Kang, Gu Hyun;Jang, Yong Soo;Kim, Wonhee;Choi, Hyun Young;Kim, Jae Guk;Kim, MinJi;Seo, Kyo;kim, Do hee;Lee, Joo-young;Choi, Jung Yoon
    • Journal of the Korean Burn Society
    • /
    • v.21 no.1
    • /
    • pp.17-21
    • /
    • 2018
  • Purpose: This study aimed to evaluate the thermal protective function of firefighter clothes and gloves through real scale fire simulations. Methods: Firstly, the fire simulation by real scale flame was performed for firefighter clothes. A manikin equipped with firefighter clothes was directly exposed to flames which energy average is 84 Kw/m2. for 22 seconds. Heat flux gauges attached on the body measured surface temperature elevation. Secondly, we also performed the other fire simulation by hot plate exposure to firefighter gloves. Firefighter gloves with heat flux gauges exposed hot plate which temperature is 300℃ in both dry and moist conditions. Primary outcome was surface temperature change of manikin body (first simulation) and hand (second simulation) over times. Results: In the first flame simulation, the surface temperature of face and shoulders elevated more rapidly comparing with the other body surface area when initial period of flame shutter open. After 18sec of shutter open, the surface temperature of upper trunk elevated rapildy. After shutter closure, high surface temperature kept continuously on right side of face and left shoulder. In the second hot plate simulation, fingers and palms showed higher surface temperature than the other areas of hands in the both dry and wet conditions. Conclusion: This study suggests that the real scale flame enables firefighter clothes to lose their heat protective function suddenly after 18 seconds. Additionally, the protective function of firefighter gloves were relatively weaker in the palmar side of fingers than the other parts of hand. There should be additional study for evaluate thermal protection performance of firefighter clothes. And, further effort for reinforce palmar side of fingers of firefighter gloves should be done.

Evaluating the Usability of Medical Body Wrap in Whole Body Bone Scan (전신 뼈 검사에서 의료용 신체 고정구의 유용성 평가)

  • Dong-Oh Shim;Woo-Young Jung;Jae-Kwang Ryu;Cheol-Hong Park;Yoon-Jae Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: When performing nuclear medicine examinations, body wraps or plastic supports are used to support and immobilize the patient's upper extremities to prevent patient safety accidents. However, the existing plastic supports compromised patient and staff safety, including finger entrapment and falls. Moreover, the body wrap provided by manufacturers compromised image quality such as upper extremities cutoff during whole body bone scan. Therefore, a new design of body wrap was developed to improve the issue, and this study aims to evaluate the usability of this medical body wrap. Materials and Methods: To evaluate the usability of the newly designed medical body wrap, a quality assessment of whole body bone scan images and a user satisfaction survey were conducted. Adult patients (male:female=129:152, age: 60.3±12.4 years, BMI: 24.0±4.2) aged 16 years or older who underwent a whole body bone scan during two periods: June to July 2022 (before improvement, n=139) and June to July 2023 (after improvement, n=142) were randomly selected for image quality evaluation. Five radiotechnologists visually evaluated the posterior view of the whole body bone image, including the left and right elbow (2 points), arm (2 points), whether the hand is extended (2 points), whether the hand is included (2 points), and the number of visible fingers (10 points), with a total of 18 points, which were converted to 100 points and analyzed for difference before and after improvement using an independent sample t-test. The user satisfaction questionnaire was evaluated using a 5-point Likert scale among 16 radiotechnologists from three general hospitals who experienced the new body wrap. Results: The image quality assessment was 82.0±13.8 before the improvement and 89.3±10.1 after the improvement, an average of 7.3 points higher, with a statistically significant difference (t=5.02, p<0.01). The user satisfaction survey showed an overall satisfaction rating of 4.1±0.8 for ease of use, 3.8±0.7 for scan preparation time, 3.9±0.7 for patient safety, 3.8±1.2 for scan accuracy, and 4.2±0.7 for recommendation (87.5% questionnaire response rate). Conclusion: The developed body wrap showed higher image quality and user satisfaction compared to the old method. Considering these results, it is deemed that the new body wrap may be more useful than existing methods.

Clinical Study on Wrist Ganglion by Newly Transformed Centro-Square Acupuncture·Moxibustion (완관절(腕關節) 결정종(結節腫)에 대한 배담(排痰)·양자침구치료(揚刺鍼灸治療)의 임상적(臨床的) 관찰(觀察))

  • Kim, Kee-Hyun
    • Journal of Acupuncture Research
    • /
    • v.17 no.4
    • /
    • pp.113-119
    • /
    • 2000
  • Objectives : Wrist ganglion is one of the most common diseases on the wrist joint. So far acupuncture, medication, drainage and local anesthetic excision therapy have been used for this disease, but the development of more effective treatment method is being expected because of frequent recurrence and side effect. Considered that most ganglion is polycystic, on the basis of classic centro-square acupuncture, newly transformed centro-square acupuncture was applied to this report. Methods : All the patients with wrist ganglion was divided into two groups. Newly transformed centro-square acupuncture was app(ied to one group composed of 11 patients and classic centro-square acupuncture to the other group with 19 patients. Classic centro-square acupuncture is made up of slanting and straight insertion. the former is a method that tips of 4 needles are inserted from the outersurface of wrist ganglion oriented to the center of the ganglion, the latter is that tip of one needle is inserted on the center of the ganglion straightly. In the newly transformed centro-square acupuncture, straight insertion of dry needle was taken place of by syringe needle in order to drain phlegm. In this report, classic and newly transformed centro-square acupuncture were used somewhat differently from original ones. Moxibustion was applied after removing all the needles. In newly transformed centro-square acupuncture, moxibustion was also applied after drainage of phlegm and slanting insertion. Results : 1. Wrist ganglion was frequently developed around the acupoint of Tae-Yeon(Tai Yuan, LU9) and Yang-Ji(Yang Chi, TE4) and the difference between occurrence of development on the left and right hand had no significancy. 2. The mean number of treatment for recovery : The newly transformed centro-square acupuncture had fewer treatment than classic one. 3. The newly transformed centro-square acupuncture was more effective than classic one. 4. As a result of following up 6 to 72 months after wrist ganglion had been eliminated, there was no recurrence. Conclusion : In the treatment of wrist ganglion, newly transformed centro-square acupuncture can be regarded as more useful method in the clinical practice, because it has comparatiely shorter duration of treatment and is more effective.

  • PDF