• Title/Summary/Keyword: Lee constant

Search Result 6,670, Processing Time 0.032 seconds

Simulation on Characteristics of Constant Power Regulator Systems in Variable Displacement Axial Piston Pump (사판식 가변 용량형 액셜 피스톤 펌프의 일정출력 레귤레이터 특성 시뮬레이션)

  • Lee, J.M.;Park, S.H.;Park, Y.H.;Lee, H.H.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.5-12
    • /
    • 2011
  • In this study, modeling and numerical simulations has been performed to investigate performance characteristics of constant power regulator system for swash plate type axial piston pump. The commercial numerical simulation software, AMESim was applied for analyzing the dynamic behavior of constant power regulator system of swash plate axial piston pump. The validity of simulation model of constant power regulator system is verified by comparing simulation results with experiments. Also, the behavior of main components of constant power regulator system such as spool, sleeve and counterbalance piston is investigated using the results of computer simulation.

Method for Measuring Dielectric Constant of Planar Dielectric Substrate (판형 유전체의 유전율 측정 방법)

  • Lee, Chang-Hyun;Kwon, Taek-Sun;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.799-804
    • /
    • 2018
  • In this paper, a method for measuring the dielectric constant of a planar dielectric substrate using the free space material constant measurement method in a general measurement environment is proposed. Two horn antennas and a network analyzer were used for S-parameter measurement and the transmission and reflection coefficients of a planar dielectric substrate were calculated from the measurement results. To obtain a reliable dielectric constant in a low-precision-measurement environment, only the magnitude of the transmission coefficient, which has a small error due to the measurement environment, is used for dielectric constant estimation. Finally, the dielectric constant is determined by comparing the measured results at different frequencies.

Time Constant Estimation of Induction Motor rotor using MRAS Fuzzy Control (MRAS 퍼지제어를 이용한 유도전동기 회전자의 시정수 추정)

  • Lee Jung-Chul;Lee Hong-Gyun;Chung Dong-Hwa;Cha Young-Doo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.155-161
    • /
    • 2005
  • This paper presents time a constant estimation of induction motor using MRAS(model reference adaptive system) fuzzy control. The rotor time constant is enabled from the estimation of rotor flux, which has two methods. One is to estimate it based on the stator current and the other is to integrate motor terminal voltage. If the parameters are correct, these two methods must yield the same results. But, for the case where the rotor time constant is over or under estimated, the two rotor nut estimation have different angles. Furthermore their angular positions are related to the polarity of rotor time constant estimation error. Based on these observation, this paper develops a rotor time constant update algorithm using fuzzy control. This paper shows the theoretical analysis as well as the simulation results to verify the effectiveness of the new method.

A Study on Hand Speed Constant to Calculate Safe Distance of Press Protective Device (프레스 방호장치 안전거리 산정을 위한 손속도상수)

  • Lee, Keun-Oh;Kim, Jong-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.40-46
    • /
    • 2010
  • To protect press operator from the after-reach hazard, current Ministry of Labor Notification(MOLN) requires the use of a formula for calculating the safe distance away from the point of operation for locating press protective devices, Two Hand Control Devices(THCD) and Active Opto-Electronic Protective Devices(AOPD), on a power press. This formula is based on a same hand speed constant of 160cm/s. While EN standards use different hand speed constant for THCD and AOPD respectively. The objective of this study is to compare two guidelines on the hand speed constant published by MOLN and EN 692, also to propose a proper hand speed constant and validate it experimentally. As a experimental result, it could be known that hand speed constant of Ministry of Labor Notification should be improved as that of EN standards.

Buckling Loads and Post-Buckling Behavio of Cantilever Column with Constant Volume (일정체적 캔틸레버 기둥의 좌굴하중 및 후좌굴 거동)

  • Lee Seung-Woo;Lee Tae-Eun;Kim Gwon-Sik;Lee Byoung-Koo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.935-940
    • /
    • 2006
  • Numerical methods are developed for solving the elastica and buckling load of cantilever column with constant volume, subjected to a compressive end load. The linear, parabolic and sinusoidal tapers with the regular polygon cross-sections are considered, whose material volume and span length are always held constant. The differential equations governing the elastica of buckled column are derived. The Runge-Kutta method is used to integrate the differential equations, and the Regula-Falsi method is used to determine the horizontal deflection at free end and the buckling load, respectively. The numerical methods developed herein for computing the elastica and the buckling loads of the columns are found to be efficient and reliable.

  • PDF

Design Consideration of Back-EMF Constant for 3-D.O.F. Spherical PM Motor

  • Go, Sung-Chul;Kang, Dong-Woo;Im, Jong-Bin;Lee, Ju;Won, Sung-Hong;Lim, Seung-Bin
    • Journal of Magnetics
    • /
    • v.15 no.2
    • /
    • pp.78-84
    • /
    • 2010
  • A 3-D.O.F. spherical PM motor has 3 degrees of freedom in its motion by tilting and rotating of a shaft, which can be applied in a range of fields. The back-EMF is proportional to the field flux and angular velocity. The back-EMF constant in conventional rotating machine has a uniform value. However, in a spherical PM motor, the back-EMF constant of the coils varies according to the tilting conditions regardless of whether the angular speed is constant. Consideration of the back-EMF constant is useful for designing 3-D.O.F. spherical PM motors. In this study, the back-EMF constant of the spherical PM motor was considered carefully.

An Efficient Battery Charging Algorithm based on State-of-Charge Estimation using 3-Phase AC-DC Boost Converter (3상 AC-DC 승압형 컨버터를 이용한 SOC 추정 기반의 효율적 배터리 충전 알고리즘)

  • Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.96-102
    • /
    • 2015
  • This paper presents battery charging method using 3-phase AC-DC boost converter. General battery charging method is that charging the battery voltage to the reference voltage according to the constant current(CC) control, when it reaches the reference voltage, charging the battery fully according to the constant voltage(CV) control. However, battery chaging time is increased because of the battery impedance, constant current charging section which shoud take the large amount of charge is narrow, and constant voltage charging section which can generate insufficient charge is widen. To improve this problem, we proposes the method to reduce the charging time according to the SOC(State of Charge) estimation using battery impedance.

An Improved Battery Charging Algorithm for PV Battery Chargers (태양광 배터리 충전기를 위한 개선된 충전 알고리즘)

  • Kim, Jung-Hyun;Jou, Sung-Tak;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.507-514
    • /
    • 2013
  • In this paper, the proposed charging algorithm is converted from the charging mode to compensate the transient state in the solar battery charging system. The maximum power point tracking (MPPT) control methods and the various charging algorithms for the optimal battery charging are reviewed. The proposed algorithm has excellent transient characteristics compare to the previous algorithm by adding the optimal control method to compensate the transient state when the charging mode switches from the constant current mode to the constant voltage mode based on the conventional constant-current constant-voltage (CC-CV) charging algorithm. The effectiveness of the proposed method has been verified by simulations and experimental results.

Operation Technology of PV-ESS Integrated Module for DC Micro Grid with Constant Power Tracking Algorithm (일정 전력 추종 알고리즘이 적용된 DC 마이크로 그리드용 PV-ESS 통합형 모듈의 운영 기술)

  • Ryu, Kyung;Kim, Jun-Mo;Lee, Jeong;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.433-441
    • /
    • 2020
  • This study proposes a constant power tracking algorithm to compensate for the intermittent characteristics of Photovoltaic connected to a DC micro grid. A PV-ESS integrated module in which distributed ESS is additionally connected is utilized for the proposed algorithm. PV performs P&O MPPT control at all times. To supplement the intermittent characteristics of PV, the proposed constant power tracking algorithm maintains constant power by operating the distributed ESS of the PV-ESS integrated module in accordance with the output state of the PV. By performing PSIM simulation and an experiment, this study verifies the performance of the integrated module of PV-ESS for DC micro grids applying the constant power tracking algorithm.

Complex Dielectric Constant of Soil Contaminated by Landfill Leachate with Measured Frequency (매립지 침출수로 오염된 토양의 측정주파수에 따른 유전특성 변화)

  • Oh Myoung-Hak;Bang Sun-Young;Park Jun-Boum;Lee Ju-Hyung;Lee Seock-Heon;Ahn Kyu-Hong
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.3
    • /
    • pp.1-11
    • /
    • 2004
  • To evaluate the applicability of dielectric constant measurement method on the geoenvironmental investigation of subsurface contaminated by landfill leachate, the analysis on dielectric characteristics of sand containing contaminated pore water by landfill leachate was performed. The separate real and imaginary parts of dielectric constant were investigated in the frequency range of 75kHz to 12MHz. The real part of dielectric constant increased at the lower frequency wherea the real part of dielectric constant decreased at the higher frequency as the concentration of leachate increased. These results can be explained by the frequency dependence of space charge polarization and orientation polarization. The imaginary part of dielectric constant on the contaminated sand with leachate increased with their concentration for whole frequency range. These results are caused by the increase of energy loss due to the enhancement of conduction in soil with leachate concentration. The results in this study indicate that the dielectric constant measurement method has potential in evaluating the contaminated soil and pore water by landfill leachate.