• Title/Summary/Keyword: Lee Sam

Search Result 4,879, Processing Time 0.038 seconds

Implementation of Image Monitoring system using High Speed Camera for Overhead Contact Wire (고속 카메라를 이용한 전차선 형상 검측 시스템 구현)

  • Cho, Hyeon-Young;Kwon, Sam-Young;Lee, Ki-Won;Park, Hyun-June;Na, Hae-Kyoung;Ko, Byeong-Hun;Park, Young
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1483-1487
    • /
    • 2006
  • In electric railway, image monitoring using high speed camera provides reliable, timely information of wear and geometry status, important in taking decisions for overhead contact wire maintenance. The contribution of this research is the development of a simple real-time monitoring system for use in measurement subsystem of contact wire and geometry of overhead contact wire in electric railway. The system has been consists of a high speed CMOS camera with resolution $1024{\times}1280$ pixels, line type laser source and PC-based image acquisition system with PCI Express slot. Vision acquisition software have been used in application programming interface for image acquisition, display, and storage with a frequency of sampling of 500 acquisitions per second.

  • PDF

Estimation of Running Safety of Electric Multiple Unit for Commute use in Incheon International Airport Railway (인천국제공항철도 통근형 차량의 주행안전성 평가)

  • Seo, Jung-Won;Hur, Hyun-Moo;Kwon, Seok-Jin;Lee, Dong-Hyung;Kwon, Sung-Tae;Hong, Yong-Ki;Park, Ok-Jeoung;Ham, Young-Sam
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.56-61
    • /
    • 2006
  • For the safety of railway, it should be evaluated for the running safety by measuring the derailment coefficient. Although railway has run the fixed and maintained rail, some of railway is derailed. This report shows the results that performed the static load test, wheelset manufacturing for test, main line running test on the basis of the derailment theory and experience. It is executed main line test into more than 110km/h for estimating the running safety of Incheon Int'l Airport EMU. As the test results, could confirm the curving performance and running safety of Incheon Int'l Airport EMU from the results of the wheel unloading, lateral force, derailment coefficient etc. Derailment coefficient was less than 0.8, and lateral force allowance limit and wheel load reduction ratio were enough safe.

  • PDF

Combution characteristics analysis of partition materials on public toilets (공공화장실 칸막이 재료의 연소특성 분석)

  • Chae, Hak-Byeong;Min, Jeong-Gi;Lee, Sang-Gwon;Jeong, Guk-Sam;Won, Jeong-Hun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.178-179
    • /
    • 2013
  • 본 연구에서는 현재 사용되고 있는 건축물 내의 화장실 칸막이 재료를 대상으로 ISO 5660-1 콘칼로리미터(Cone calorimeter) 실험을 실시하여 대상 실험 재료들의 연소 특성을 비교 평가 하였다. 모두 5종류의 실험체를 사용하였으며, 화재 발생시 연소 중요 평가항목인 착화시간(Time to ignition), 총 방출열량(Total heat release), 최고 열방출율(Peak heat release rate), 평균 열방출율(Mean heat release rate)을 중점적으로 평가하였다. 실험결과, 착화시간은 일반 합판패널에서 빠르게 일어났으며, 총 방출열량, 최고 열방출율, 평균 열방출율은 고밀도 압축패널에서 높게 나타난 것으로 분석되었다.

  • PDF

Development of Antibacterial Concrete for Sewage Facilities (하수구조물용 항균콘크리트의 개발)

  • Kim Gyu Yong;Kim Han Jun;Lee Seung Hoon;Chung Sam Yong;Khil Bae Su;Kim Do Su
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.541-544
    • /
    • 2004
  • The purpose of this study is to examine the antibiotic and physical properties of antibiotic concrete added inorganic liquor-type antibiotic agent(as named for Antibio-C) as the basic data for the development of antibiotic concrete. The main experimental variables were the types of antibiotic agents and it is tested for the properties of antibiotic, flow, compressive strength, crack-resistance and durability of concrete. As results, concrete containing antibiotic agent presented the strong antibiotic activities compared with non-added concrete. Also antibiotic concrete showed the higher or equality properties than non-added concrete with respect to compressive strength, crack resistance and durability such as neutralization depth.

  • PDF

Spalling Resistance of $80{\sim}100MPa$ High Strength Concrete ($80{\sim}100MPa$급 고강도 콘크리트의 폭렬방지)

  • Heo, Young-Sun;Pei, Chang-Chun;Lee, Jae-Sam;Han, Chang-Pyung;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.481-484
    • /
    • 2006
  • This study investigates the engineering and fire endurance properties of ultra high strength concrete. The mixture proportions with water to binder ratios (W/B) of 0.15 and 0.25 consist of various adding ratios, such as 0, 0.05, 0.1, 0.15, 0.2, 0.25 and 0.3 percent respectively, of polypropylene (PP) fiber. As for the parameters of specimens, fluidity, compressive strength and unloading fire test were carried out. Test showed that an increase of fiber contents had the favorable properties in fire endurance performance; specimens in W/B 15% required 0.3vol% of PP fiber and specimens in W/B 25% needed only 0.1vol% to prevent spalling.

  • PDF

Design of Force Rebalance Loop for Silicon Accelerometer using Parametric Robust Control Technique (변수적 강인해석기법을 이용한 실리콘 가속도계의 재평형루프 설계)

  • Seong, Sang-Gyeong;Lee, Jang-Gyu;Gang, Tae-Sam
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.3
    • /
    • pp.124-132
    • /
    • 2000
  • In this paper, presented are an active surface-micromachined silicon accelerometer, force rebalance loop using parametric robust control method, and experimental results with a real micromachined accelerometer. And finally, a robust controller of the form of PID compensator was designed to construct force rebalance loop. Through the frequency response analysis, it is shown that the loop guarantees appropriate stability and robustness. Experiments with a real accelerometer demonstrated that the proposed loop effectively controls the position of the accelerometer's proof mass. It also demonstrated that the resolution of the fabricated accelerometer is better than 1mg. Compared with a commercial accelerometer the proposed force rebalance silicon accelerometer showed better performances.

  • PDF

Design of $H_{\infty}$ Control of Time-Delayed Linear Systems Using Model Transformation (모델변환을 이용한 시간지연 선형시스템의 지연종속 $H_{\infty}$ 제어)

  • Ma, Sam-Sun;Lee, Hee-Song;Kim, Jin-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.9
    • /
    • pp.409-416
    • /
    • 2001
  • This paper deals with the design of delay-dependent $H_{\infty}$ control for time-delayed linear systems. We propose the two different model transformations to handle efficiently the time delay and derive conditions linear matrix inequalities (LMI's) of which are dependent on the size of time-delay and its time-derivative. The $H_{\infty}$ controller is obtained by checking the feasibility of these LMI's. Finally, we show the usefulness and applicability of our results by an example.

  • PDF

A Study on Robust Stability of Uncertain Linear Systems with Time-delay (시간지연을 갖는 불확정성 선형 시스템의 강인 안정성에 관한 연구)

  • Lee, Hee-Song;Ma, Sam-Sun;Ryu, Jeong-Woong;Kim, Jin-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.615-621
    • /
    • 1999
  • In this paper, we consider the robust stability of uncertain linear systems with time-delay in the time domain. The considered uncertainties are both the unstructured uncertainty which is only Known its norm bound and the structured uncertainty which is known its structured. Based on Lyapunov stability theorem and{{{{ { H}_{$\infty$ } }}}} theory known as Strictly Bounded Real Lemma (SBRL), we present new conditions that guarantee the robust stability of system. Also, we extend this to multiple time-varying delays systems and large-scale systems, respectively. Finally, we show the usefulness of our results by numerical examples.

  • PDF

A Power Line Proximity Detecter for Mobile Crane (크레인의 고압 전선로 접근 경보장치)

  • Choi, Sam-Jin;Kim, Hyun-Sik;Lee, Jong-Ho;Kim, Il-Hwan;Park, Chan-Won
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2374-2376
    • /
    • 2001
  • In this paper we have developed a Power Line Proximity Detecting device for Mobile Crane by using a Derivation Electric-Potential Detection method. A mobile crane worker can be easily exposed to a dangerous electrical shock and the electrocution while they are working at near the high-voltage electrical lines. The derivation electric-potential of the power lines have been simulated in our experiment, Also, microprocessor-based detecting device and transmitter/receiver modules are introduced to show a solution for the dangerous mobile crane working environment. As a result, It has been shown a good functional field test.

  • PDF