• Title/Summary/Keyword: Lee Ha-Bok

Search Result 446, Processing Time 0.03 seconds

Subcutaneous Cysticercosis at Abdominal Wall: Case Report (복벽에 발생한 낭미충증 1례)

  • Kim, Eui Sik;Park, Jeong Jun;Noh, Bok Kyun;Hwang, Jae Ha;Kim, Kwang Seog;Lee, Sam Yong
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.249-251
    • /
    • 2006
  • Human cysticercosis is an infestation with C. cellulosae, the larval stage of the tapeworm T. solium. It prevails in regions of poverty and where personal hygiene is poor. They can lodge in almost any tissue, but cysticerci are most frequently found in brain, skeletal muscle, subcutaneous tissues. We experienced a 41-year old male with $5{\times}12cm$ sized movable non tender brownish hard mass at lateral abdominal wall. The laboratory study didn't show any specific symptoms except peripheral blood eosinophilia and positive parasite ELISA screen for cysticercosis. The ultrasonogram revealed multiple ill-defined mixed echoic inflamatory lesion. Excisied cyst showed multiple severe foul-odor gelatinous subcutaneous mass. Microscopic examination disclosed necrotic body with foreign body reaction, massive eosinophilia and dead parasitic organism, compatible with cysticercosis. There was no evidence of recurrence during 12 months follow-up.

Performance of Night Soil Treatment Plant using B3(Bio-Best-Bacillus) System (B3공법을 이용한 분뇨처리시설 처리효율에 관한 연구)

  • Seo, Yun-Ha;Lee, Jung-Bong;Choi, Sung-Yong;Kim, Deug-Ho;Kim, Jin-Hwan;Byeun, Jeung-Bok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.407-412
    • /
    • 2010
  • The purpose of this study was to investigate removal efficiencies of contaminants in night soil treatment plant using the B3 system. The samples were collected from retaining tank and settlement tank in Yechon night soil plant. We experimented concentrations of BOD, COD, SS, TN and TP. Concentration data were processed using removal efficiencies by season and correlation analysis with pilot running parameters. Removal efficiencies of total organic carbon was over 96%, TN was 98% during summer, 80.9% during winter. In the case of TP, the highest removal efficiencies was 94.1% during fall and the lowest removal efficiencies was 82% during spring. Results of correlation analysis showed two positive correlation groups and one negative group. Positive correlations were among temperature, BOD and TN. The others were pH, BOD, COD, SS, TN and TP. Negative correlation were among MLSS, BOD, COD, SS, TN, TP.

Analysis of the Switch Installation Criteria by Increasing Operating Capacity in Distribution Line (배전선로 운전용량 상향에 따른 개폐기 설치 기준 분석)

  • Jo, Nam-Hun;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.6
    • /
    • pp.290-295
    • /
    • 2002
  • The present assignment in installing the number of switches for distribution line was made on the basis of a normal feeder capacity 7,000kVA in KEPCO(Korea Electric Power Corporation), Korea. But the normal capacity is revised to 10000kVA in 1998. Even increasing limit of the operating capacity of the distribution lines enables us to give some benefit for the operation flexibility and investment cost of the distribution system. It is disadvantageous in the viewpoint of supply reliability. In distribution systems, switches are equipped to improve the reliability of distribution systems by minimizing the outage section due to fault and maintenance. Utility generally improves the reliability by minimizing the length of outage section, which is caused by fault and maintenance, through switch equipment on distribution system. In order to cope with the changes such as operation capacity, it is necessary to study whether the present criteria is reasonable or not, also to confirm whether the present criteria of installing switches in line is improved or not. In this study, we proposes the number of switch per feeder on the basis of present operation capacity in distribution system.

DETERMINATION OF CLOCK OFFSET USING GPS CARRIER PHASE MEASUREMENTS (GPS 반송파위상 데이터를 이용한 시계오차 추출)

  • Ha, Ji-Hyun;Park, Kwan-Dong;Lee, Chang-Bok
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.4
    • /
    • pp.491-500
    • /
    • 2005
  • Every time laboratory in the world follows an international standard time scale and GPS (Global Positioning System) is playing an important role. Korea Research Institute of Standards and Science is also operating a permanent GPS station for time transfer. To improve the accuracy and precision of the clock offsets derived from GPS we used carrier phase measurements. In addition, we tested four different kinds of GPS satellite orbits and compared the results. The precision of the time offsets using rapid and ultra-rapid orbits was about 0.5 nanoseconds (ns). Tn the case of broadcast orbits, the precision was better than 2 ns.

Experimental Evaluation of Deployment Time of Active Hood Lift System According to Structural Improvement (능동후드리프트 시스템의 구조 설계에 따른 전개시간의 실험적 평가)

  • Lee, Tae-Hoon;Yoon, Gun-Ha;Park, Chun-Yong;Kang, Je-Won;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.3
    • /
    • pp.265-269
    • /
    • 2016
  • In this research, the performances of active hood lift system(AHLS) are investigated according to the structural improvement through the experimental test. After introducing the working principle of the AHLS activated by a gunpowder actuator, the structural problems that cause the inefficiencies in the actuation are analyzed to reduce the deployment time of system. Sequentially, the improved structural model is proposed base on the analysis. The deployment time of AHLS are evaluated by the experimental test, and it has been identified that the improved model can provide a faster deploying time of AHLS.

Performance Evaluation of Active Hood Lift System of Passenger Vehicles with Different Operating Method (승용차 능동후드리프트 시스템의 전개 방식에 따른 성능 평가)

  • Lee, Tae-Hoon;Yoon, Gun-Ha;Park, Chun-Yong;Kang, Je-Won;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.3
    • /
    • pp.242-247
    • /
    • 2016
  • This work investigates the performances of active hood lift system(AHLS) activated by two different operating methods through the experimental test. In the AHLS, the deployment time of the system and decrement of pedestrian injury are the most important factors for the pedestrian safety during the pedestrian-vehicle impact. After introducing the working principle of AHLS using spring actuator and gunpowder actuator, the deployment time of AHLS and decrement of pedestrian injury are evaluated by the experimental test. It has been identified that the gunpowder actuator can provide a faster deploying time of AHLS.

Inhibitory Effects of Triterpenoids on Interleukin-8/CINC-1 Induction in LPS-Stimulated Rat Peritoneal Macrophages

  • Min, Bok-Gi;Lee, Gyeong-Im;Ha, Joo-Young;Min, Kyung-Rak;Kim, Ju-Sun;Kang, Sam-Sik;Kim, Young-Soo
    • Natural Product Sciences
    • /
    • v.2 no.1
    • /
    • pp.48-55
    • /
    • 1996
  • The CINC-1 is a member of rat interleukin-8 with chemotactic and activating properties to neutrophils. The CINC-1 induction in LPS-stimulated rat peritoneal macrophages was analyzed using a sensitive enzyme-linked immunosorbent assay. The peritoneal macrophages contained about 3 ng/ml as a basal level, and induced to maximal 18 ng/ml of CINC-1 by stimulation with 5 ${\mu}g/ml$ of LPS. Antiinflammatory steroids of dexamethasone and triamcinolon significantly suppressed the CINC-1 induction, where as aspirin and idomethacin did not show suppression. Inhibitory effects on the CINC-1 induction by natural triterpenoids having steroidal structures were analyzed. Among the 39 kinds of triterpenoids isolated from herbal medicines, acacigenin B and nigaichigoside F1 exhibited the highest suppression on the CINC-1 induction.

  • PDF

Air Similarity Test and Analysis of Steam Turbine Labyrinth Seal for Leakage Verification (스팀터빈용 래비린스 실의 누설량 규명을 위한 공기상사 실험 및 해석)

  • Ahn, Sang-Kyu;Kim, Seung-Jong;Lee, Yong-Bok;Kim, Chang-Ho;Ha, Tae-Wong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1149-1149
    • /
    • 2006
  • The leakage characteristic is an important factor in power plant. However, most of power plant have efficiency problem which is occurred leaking between high pressure steam turbine axle and stator. The labyrinth seal which is used between the main turbine axle and stator in the power plant. Because it is able to be non-contact seal and it is minimize clearance to decrease the leakage. But its actual system is too huge to experiment. Therefore, most steam turbine seal performance tests were conducted by air similarity test. This paper described a test facility and program for air similarity test of high pressure steam turbine seal. A test facility has been designed and built to evaluate leakage verification of labyrinth seal. The test facility consist of air compressor, anti-swirl labyrinth seal for 1/3 air similarity model, pressure transducer, air flow measure system, instrumentation and auxiliary system. For evaluation of steam turbine seal performance, the air similarity test of labyrinth seal leakage verification was conducted and we compared experiment data and analysis result.

  • PDF

Evaluate Changes in Soil Chemical Properties Following FGD-Gypsum Application

  • Lee, Yong-Bok;Bigham, Jerry M.;Kim, Pil-Joo
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.4
    • /
    • pp.294-299
    • /
    • 2007
  • Natural gypsum has been used as a soil amendment in the United States. However, flue gas desulfurization (FGD)-gypsum has not traditionally been used for agricultural purpose although it has potential benefit as a soil amendment. To expand use of FGD-gypsum for agricultural purpose, the effect of FGD-gypsum on soil chemical properties was investigated in the field scales. Application rates for this study were 0 (control), 1.1, and 2.2 Mg ha-1 of FGD-gypsum. After two year application, the soil samples were taken to 110 cm depth and sub-sampled at 10 cm intervals. The heavy metal contents in FGD-gypsum were lower than ceiling levels allowed by regulations for land-applied biosolids. Soil pH was not largely affected by FGD-gypsum application. Although degree of calcium (Ca) saturation in surface horizons increases only slightly with respect to the control, there is a clear decrease in exchangeable aluminum (Al). FGD-gypsum clearly increases the soil electrical conductivity (EC) with increasing application rate. Water-soluble Ca and sulfate is increased with FGD-gypsum application and these ions moved to a depth of at least 80 cm after only 2 years. We conclude that surface application of FGD-gypsum can mitigate toxicity of Al and deficiency of Ca in subsoil of acid soil.

A Study on Dispersion Characteristics of Odor from Swine Farms (양돈장 발생 악취의 확산특성 연구)

  • Kim, Doo-Hwan;Ha, Duck-Min;Lee, In-Bok;Choi, Dong-Yun;Song, Jun-Ik
    • Journal of Animal Environmental Science
    • /
    • v.20 no.2
    • /
    • pp.41-48
    • /
    • 2014
  • This study was conducted to investigate the dispersion prediction of odor from swine farms in Korea. Gaussian Plume model used in considering of farm size, wind velocity, atmospheric stability and threshold odor unit to prediction of odor dispersion based on the survey on current state of odor emission and control from 48 site of swine farms. Farm size, wind velocity and atmospheric stability were affected the distance of odor dispersion, showed longer distance in cases of large farm, low wind velocity and stable atmospheric condition. We will suggestion the adjusted distance of odor dispersion according to farm size was estimated to 180 m in small farm and 320 m in large farm when apply the 3 OU, 5 m/s wind velocity and stable atmospheric condition.