• 제목/요약/키워드: Leakage restoration

검색결과 90건 처리시간 0.025초

영상데이터의 개인정보 영역에 대한 인공지능 기반 비식별화 기법 연구 (Research on Artificial Intelligence Based De-identification Technique of Personal Information Area at Video Data)

  • 송인준;김차종
    • 대한임베디드공학회논문지
    • /
    • 제19권1호
    • /
    • pp.19-25
    • /
    • 2024
  • This paper proposes an artificial intelligence-based personal information area object detection optimization method in an embedded system to de-identify personal information in video data. As an object detection optimization method, first, in order to increase the detection rate for personal information areas when detecting objects, a gyro sensor is used to collect the shooting angle of the image data when acquiring the image, and the image data is converted into a horizontal image through the collected shooting angle. Based on this, each learning model was created according to changes in the size of the image resolution of the learning data and changes in the learning method of the learning engine, and the effectiveness of the optimal learning model was selected and evaluated through an experimental method. As a de-identification method, a shuffling-based masking method was used, and double-key-based encryption of the masking information was used to prevent restoration by others. In order to reuse the original image, the original image could be restored through a security key. Through this, we were able to secure security for high personal information areas and improve usability through original image restoration. The research results of this paper are expected to contribute to industrial use of data without personal information leakage and to reducing the cost of personal information protection in industrial fields using video through de-identification of personal information areas included in video data.

복합레진 수복시 상아질 표면 처리가 미세 변연 누출에 미치는 영향에 관한 연구 (THE EFFECT OF MOISTENING OF ETCHED DENTIN AND ENAMEL SURFACE ON THE MICROLEAKAGE OF COMPOSITE RESINS)

  • 전철민;권혁춘;이정식;이명종;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.321-338
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of moistening and air-drying of acid conditioned dentin and enamel on the marginal microleakage. In this study, Class V cavity were prepared on both buccal and lingual surface of sixty extracted human premolars with cementum margin. These specimens were randomly devided into three groups and three dentin adhesives(Scotchbond Multi-Purpose, All bond 2, Prisma Universal Bond 3) were applied to each group. The specimens in each group were subdevided into four groups (Wet/primed, Dry/primed, Wet/not primed, Dry/not primed) and the etched dentin and enamel surface were treated these four surface treatments prior to the placement of a bonding agent or adhesive. Wet/primed group was simply blot-dried with a damp facial tissue before primer placement ; Dry/primed group was air dried for 30 seconds before the placement of a primer ; Wet/not primed group and Dry/not primed group were not primed after blot dried and air dried for 30 seconds each group. The bonding agent and composite resin were applied for each group. All specimens were exposed to 500 cycle of thermal stress. Specimens were placed in a silver nitrate solution and then sectioned buccolingually through the center of the restoration. The dye penetrations of the specimens were observed with a stereo microscope. The statistical test were applied to the results using a one way analysis variance (ANOVA) and Duncan's multiple range test. The aspects of silver ion penetration into the resin/dentin interface were examined under scanning electron microscopy. The results were as follows. 1. In all groups, the enamel margin showed significantly lower leakage value than the cementum margin (p<0.05). 2. Regardless of various surface treatment and dentin adhesives, there was no significant difference at the enamel margins (p>0.05). 3. At the dentin margins, the leakage values of Dry/not primed group showed significantly higher than that of the other groups (p<0.05). The leakage values of Wet/primed group showed significantly lower than that of the other groups, but, there was no significant difference between Wet group and Dry group. 4. There was no significantly difference between the dentin adhesives regarding the surface treatments in all groups(p>0.05). 5. On the backscatterd scanning electron microscopy observation, the penetration of the silver ion occured at the bonding resin/dentin interface. In the Wet/primed group, resindentin hybrid zone and resin penetration into the dentin was observed. The resin tags were compactively formed to a thickness of $3\sim4{\mu}m$ at the upper part of dentinal tubules. In the Dry/primed group, the thickness of the hybrid zone and the diameter, depth of the resin tags diminished. In the Non-primed groups, the hybrid zone was not identified and few resin tag was observed. There was the gap formation in the resin/dentin interface.

  • PDF

복합레진 수복시 복합용기 및 단일용기 상아질 접착제의 미세변연누출에 관한 연구 (MICROLEAKAGE OF CURRENT DENTIN BONDING SYSTEMS)

  • 류주희;박동성;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.55-66
    • /
    • 1999
  • The purpose of this study was to evaluate the microleakage of 5 current dentin bonding systems which are composed of 2 multi-bottle systems(Scotchbond Multi-Purpose, All Bond2) and 3 one-bottle systems(Single bond, One-Step, Prime & Bond). In this in vitro study, class V cavities were prepared on buccal and lingual surfaces of sixty extracted human premolars and molars on cementum margin. The experimental teeth were randomly divided into six groups of 10 samples (20 surfaces) each, Group 1 : Scotchbond Multi-Purpose ; Group 2 : All Bond 2 ; Group 3 : Single Bond ; Group 4 : One-Step ; Group 5 : Prime & Bond ; Group 6 : no bonding agent(control). The bonding agent and composite resin were applied for each group following the manufacturer's instructions. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 60 teeth were placed in 2% Methylene blue dye for 24 hours, then rinsed with tab water. The specimen were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen were then observed with a stereomicroscope at ${\times}20$. The results of study were statistically analyzed using the Student-Newmann-Keul's Methods and the Mann-Whitney Rank Sum Test. The resin/dentin interfaces were examined under Scanning Electron Microscopy. The results of this study were as follows. 1. None of the dentin bonding systems used in this study showed significant difference in leakage values at both the enamel and the dentin margins (P>0.05). 2. In all groups except the control, leakage value seen at the enamel margin was significantly lower than that seen at the dentin margin (P<0.05). 3. Compared to the control group, all the groups treated with dentin bonding systems showed significantly lower leakage value at both enamel and dentin margins (P<0.05). 4. In the SEM view, gaps were observed in the composite resin / dentin interface in group 6 where no dentin bonding agent was used, and in all the other groups (group 1, 2, 3, 4, 5) composite resin, hybrid layer, and dentin were seen to be closely adhering to each other where there were no leakages. Well-developed resin tags 3~100${\mu}m$ in length infiltrated dentinal tubules past the hybrid layer and a hybrid layer 1~5${\mu}m$ thick had developed between the dentinal surface and the composite resin surface.

  • PDF

Flowable Composite Resin의 미세변연누출 및 전단결합강도 (MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

Sealed amalgam restoration의 미세누출에 관한 연구 (A STUDY ON MICROLEAKAGE OF SEALED AMALGAM RESTORATION)

  • 이상헌;이재천;이상훈
    • 대한소아치과학회지
    • /
    • 제27권1호
    • /
    • pp.54-61
    • /
    • 2000
  • 아말감은 널리 사용되어 온 대표적 치과재료이지만 치질과의 접착성이 없어 와동의 형태에 의해 유지되는 단점을 가진다. 아말감 수복물은 산화물에 의한 변연봉쇄가 일어나기 전까지 초기에 큰 미세누출을 보이며 수복초기에 이를 적절하게 예방하지 않으면 타액이나 미생물이 와동내에 침투하게 되고 이로 인해 수복 후의 과민반응, 충전물의 용해 및 파괴, 변연 변색과 2차 우식이 유발되어, 결과적으로 수복물의 수명이 단축되며 치수 병변이 발생될 수도 있다. 최근 기존 아말감 수복의 장점을 그대로 유지하면서 치질삭제를 줄이고 변연을 봉쇄하며 소와열구에 예방적 처치를 함께 할 수 있는 수복법이 제안되었는데 이를 이른바 sealed amalgam이라 한다. 이 술식은 예방적 확대 없이 병소만을 제거한 뒤 수복물 변연과 인접 소와열구에 치면열구전색재를 도포함으로서 소와열구의 예방적 충전은 물론 수복물 변연과 치질사이의 틈을 봉쇄하여 미세누출을 감소시킬 수 있다고 하였다. 이에 저자는 아말감 수복후 수복물의 마무리 처리와 전색재 적용시점을 달리 하여 sealed amalgam 수복과 기존의 아말감 수복과의 미세누출의 차이를 비교하고자 30개의 상, 하악 소구치를 준비하여 V급 와동을 소구치의 협, 설측에 형성하고 통상적 아말감 수복을 시행한 후 다음의 각 군으로 나누어 처리하였다. 제 1 군 : 24시간 후 연마 (대조군) 제 2 군 : 연마하지 않음, 즉시 전색재 적용 제 3 군 : 연마하지 않음, 열순환(thermocycling) 500회 후 전색재 적용 위의 처리 후 각 군을 $5^{\circ}C$$55^{\circ}C$의 온도변화를 30초씩 번갈아 주며 총 500회의 열순환을 실시한 후 1% methylene blue 용액에 침윤시켜서 100% 습도가 유지된 $37^{\circ}C$ 항온기에 24시간 보관하였다. 치아를 레진에 매몰한 후 협설측으로 치아 장축에 평행하게 절단하여 stereomicroscope를 사용해 색소침투도를 관찰하여 다음과 같은 결론을 얻었다. 1. 평균 미세누출은 연마하지 않고 바로 치면열구전색재를 도포한 2군이 가장 낮았고, 연마만 시행한 1군이 가장 높았다. 2. 실험군간의 미세누출 비교에서 연마만 시행한 1군은 2군에 비해 미세누출이 켰으며 통계적으로 유의성 있는 차이를 보였다(p<0.05). 3군은 1군보다 평균미세누출이 작았으나 통계적으로 유의한 차이가 없었다(p>0.05). 2군은 3군보다 평균 미세누출이 작았으나 통계적으로 유의한 차이가 없었다(p>0.05).

  • PDF

SEM과 3차원 재구성법을 이용한 수복면의 위치와 와동 크기에 따른 미세누출도 분석 (MICROLEAKAGE OF THE CLASS V CAVITY ACCORDING TO RESTORATION SITE AND CAVITY SIZE USING SEM AND THREE-DIMENSIONAL RECONSTRUCTION TECHNIQUES)

  • 양인서;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제30권2호
    • /
    • pp.112-120
    • /
    • 2005
  • 본 연구에서는 수복면의 위치와 와동의 크기에 따른 미세누출도의 차이를 확인하기 위해 3차원 재구성법에 의한 색소침투량과 주사전자현미경 검경을 통한 변연틈새의 비율을 측정하였다. 32개의 건전한 대구치의 협/설면과 인접면에 각기 $2\;{\times}\;2\;{\times}\;1.5\;mm$의 작은 와동과 $4\;{\times}\;2\;{\times}\;1.5\;mm$크기의 큰 5급 와동을 형성 한 다음, 자가부식형 접착시스템으로 치면 처리하고 혼합형 복합레진인 Esthet X로 단일 충전하였다. 5도와 55도 사이에서 1000회의 열순환을 시킨 다음, 레진 복제물을 제작하고 SEM 검경을 통해 전체 변연길이에 대한 변연틈새의 비율을 측정하였다. 또한 열순환된 치아에 $50\%$ 질산은 용액으로 색소를 침투시킨 후 자가중합형 레진에 포매하여 0.25 mm두께의 간격으로 연속적으로 갈아내면서 각각의 단면상을 채득하였다. 각 단면상을 3차원으로 재구성하여 미세누출도를 정량적으로 평가하였다. 3차원 색소 침투량의 유의성 검정에는 Two-way ANOVA와 independent T-test를, 변연틈새의 비율에는 Mann-Whitney U test를 사용하였으며 , 두 방법 사이의 Spearman's rho test로 평가하여 다음과 같은 결과를 얻었다. 1 미세누출도는 수복면의 위치와 와동의 크기에 의해 영향을 받았다. 즉 협/설면과 작은 와동보다는 인접면과 큰 와동에서 더 많은 미세누출을 보였다. 2. 두 방법 사이에는 높은 상관 관계를 보였다 (상관계수 = 0.614/P= 0.000). 이상의 연구 결과로 볼 때, 협/설면과 작은 와동의 수복물보다는 인접면과 큰 와동의 수복물에서 더 많은 미세누출을 보였으므로, 불필요한 치질 삭제를 줄임으로써 변연부의 노출이 커지는 것을 막아야 할 것이다.n-St/SS 군에서는 비표준화 medium 규격 master cone과 스테인레스 스틸 spreader를, 그리고 Non-St/NT 군에서는 비표준화 medium 크기 master cone과 니켈-티타늄 finger spreader를 각각 사용하였다. 충전된 근관은 $37^{\circ}C$, 상대습도 $100\%$하에서 24시간 보관한 후, 치근단 1, 3및 5 mm수준에서 횡절단하여 입체현미경 하에서 관찰하고 컴퓨터에 저장한 다음, $Auto^{(R)}$CAD 2000 프로그램을 이용하여, 형성된 근관 및 gutta-percha 충전물의 외형을 추적하여 근관내 gutta-percha 면적비를 계산하였다. Gutta-percha 면적비의 결과치는 two-way ANOVA를, 그리고 accessory cone 수는 one-way ANOVA 및 Duncan's multiple range test를 이용하여 통계 분석하여 다음과 같은 결과를 얻었다. 스테인레스 스틸 finger spreader를 사용한 경우 및 니켈-티타늄 finger spreader를 사용한 경우 공히, 모든 치근단 수준에서 비표준화 medium 크기 master cone 사용군이 ISO 표준화 규격의 master cone 사용군에 비해 유의하게 높은 gutta-percha 면적비를 나타내었다 (p < 0.01). 비표준화 medium크기 master cone 사용군에서는 표준화 규격의 master cone 사용군에 비해 유의하게 적은 수의 accessory cone이 사용되었다 (p < 0.01). 대학생간에는 유의한 차이(p<0.05)가 인정되었다. 응답자의 체형은 ${\ulcorner}$적당하다${\lrcorner}$고 응답한 경우가 가장 많이 이러한 음식을 즐겨 먹었으며(49.5%), 그

Mandibular condyle and infratemporal fossa reconstruction using vascularized costochondral and calvarial bone grafts

  • Jang, Hyo Won;Kim, Nam-Kyoo;Lee, Won-Sang;Kim, Hyung Jun;Cha, In-Ho;Nam, Woong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권2호
    • /
    • pp.83-86
    • /
    • 2014
  • There are some difficulties in approaching and removing the lesion in infratemporal fossa because of its anatomical location. After wide excision of tumor lesion, it is also difficult for reconstruction of mandibular condyle and cranium base on infratemporal fossa. Besides, there are some possibilities of cerebrospinal fluid leakage, intracranial infection and bone resorption. It is also challenging for functional reconstruction that allows normal mandibular movement, preventing mandibular condyle from invaginating into the skull. In this report, we present 14-month follow-up results of a patient who had undergone posterior segmental mandibulectomy including condyle and infratemporal calvarial bone and mandible reconstruction with free vascularized costochondral rib and calvarial bone graft to restoration of the temporomandibular joint area.

Ovate Pontic을 이용한 상악 전치부 심미수복 (The Use of Ovate Pontics in the Maxillary Anterior Esthetic Zone: A Clinical Report)

  • 최미라
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.23-29
    • /
    • 2009
  • 1933년 Dewey와 Zugsmith가 처음 ovate pontic을 소개한 이후 1990년대 말부터 임상적으로 널리 사용되고 있다. Ovate pontic은 심미적이고 위생적인 자연치의 emergence profile을 더 정교하게 재현할 수 있는 방법으로 알려져 있다. 특히, 상악 전치부가 상실된 경우 발치 시기부터 ovate pontic의 형태를 가진 레진 임시수복물을 제작해 줌으로서 치간유두를 보존시켜 치간공극의 발생을 최소화하여 심미적이고 발음의 이상이 없는 최종보철물을 제작할 수 있다. 본 증례에서는 치아상실부위에서 치간유두의 상실을 최소화하고 자연치와 유사한 emergence profile을 지닌 보철물을 제작하기위해 ovate pontic을 이용하여 처치한 치험예를 문헌고찰과 함께 보고하고자 한다.

Multilevel Percutaneous Vertebroplasty (More than Three Levels) in the Management of Osteoporotic Fractures

  • Zidan, Ihab;Fayed, Ahmed Abdelaziz;Elwany, Amr
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권6호
    • /
    • pp.700-706
    • /
    • 2018
  • Objective : Percutaneous vertebroplasty (PV) is a minimally invasive procedure designed to treat various spinal pathologies. The maximum number of levels to be injected at one setting is still debatable. This study was done to evaluate the usefulness and safety of multilevel PV (more than three vertebrae) in management of osteoporotic fractures. Methods : This prospective study was carried out on consecutive 40 patients with osteoporotic fractures who had been operated for multilevel PV (more than three levels). There were 28 females and 12 males and their ages ranged from 60 to 85 years with mean age of 72.5 years. We had injected 194 vertebrae in those 40 patients (four levels in 16 patients, five levels in 14 patients, and six levels in 10 patients). Visual analogue scale (VAS) was used for pain intensity measurement and plain X-ray films and computed tomography scan were used for radiological assessment. The mean follow-up period was 21.7 months (range, 12-40). Results : Asymptomatic bone cement leakage has occurred in 12 patients (30%) in the present study. Symptomatic pulmonary embolism was observed in one patient. Significant improvement of pain was recorded immediate postoperative in 36 patients (90%). Conclusion : Multilevel PV for the treatment of osteoporotic fractures is a safe and successful procedure that can significantly reduce pain and improve patient's condition without a significant morbidity. It is considered a cost effective procedure allowing a rapid restoration of patient mobility.

Outcome Assessment of Endodontic Treatment of Mandibular Second Molars with C-shaped Canals in Elderly Patients

  • Go, Yu-Ra;Kim, Mi-Yeon;Kim, Sun-Ho;Kim, Jeong-Hee;Kim, Ran-Ah
    • Journal of Korean Dental Science
    • /
    • 제14권2호
    • /
    • pp.61-68
    • /
    • 2021
  • Purpose: The aim of this study was to investigate the outcomes of endodontic treatment of mandibular second molar with C-shaped canal in elderly patients and related factors affecting the survival of the tooth. Materials and Methods: From 2010 to 2015, the survival rate following endodontic treatment was evaluated in elderly patients over 60 years who visited the Veterans Health Service Medical Center for endodontic treatment. The presence of C-shaped canals was confirmed using clinical records and radiographic features. Patient's age, sex, systemic diseases, tooth location, vitality, signs and symptoms, fractures, caries, apical radiolucency, canal shaping methods, sealer leakage, filling voids, and restoration of prosthesis were included in the analyses as confounding variables. The survival rate of teeth was analyzed using Kaplan-Meire analysis and the relationship between the survival rate and variables was analyzed using Simple and Multiple Cox regression analysis. Result: In total, 107 teeth in elderly patients had C-shaped canal. The survival rate of teeth that received endodontic treatment was 63.70%. None of the factors investigated significantly influenced the survival rate (P>0.05). Conclusion: In elderly patients with C-shaped canal, the survival rate after root canal treatment was not significantly different from that of other mandibular molars.