• Title/Summary/Keyword: Leakage management

Search Result 662, Processing Time 0.024 seconds

A Scheme for Detecting and Preventing an Unauthorized Device Using Context Awareness and Mobile Device Management (상황 인지 기술과 모바일 단말 관리 기술을 이용한 비인가 단말 탐지 및 차단 기법)

  • Mun, Jiman;Jung, Souhwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.1
    • /
    • pp.1-8
    • /
    • 2014
  • This paper proposed a method that prevents data leakage and modulation and detects an unauthorized device by using AP and mobile device. Most of existing method for detecting and preventing an unauthorized device are similar to type of Evil Twin. However, in previous studies can not resolve many security accident and have the problem to cope with effectively security accident on various network. In order to solve these problem, companies prepare security accident through the varies policy and guideline. but It is hard to prevent all security accident because it is consistently increasing everyday. This paper suggests technique of detecting and preventing an unauthorized device using Context Awareness and Mobile Device Management. Firstly, when mobile device go into internal network, server distinguish access permission and authorization of mobile device using acquiring the conetxt information of mobile device. By using this result, server applies the appropriate management technique to the mobile device for leakage and accident of internal network.

Design and Implementation of an Efficient Water Count Management System (효율적인 상수도 유수율 관리 시스템 설계 및 구현)

  • Lee, Seak-Jae;Hwang, Jeong-Hee;Ha, Eun-Sil
    • Journal of Digital Contents Society
    • /
    • v.11 no.2
    • /
    • pp.169-175
    • /
    • 2010
  • The important society facility to maintain daily lives and the various activity is the water service. In this paper, we propose a design and implementation method of water count management system for the measurement, distribution and control of water quantity. The proposed system for systematic facility management and effective water service administration is a design methodology for foundation facility of water service to provide good quality water and to prevent a leak of water, estimating the water capacity.

Performance of Automotive Wheel Bearing Grease by Water Contents (수분함량에 따른 자동차용 휠베어링 그리스 품질특성 연구)

  • Lim, Young-Kwan;Lee, Eun-Hee;Lee, Joung-Min;Jeong, Choong-Sub
    • Tribology and Lubricants
    • /
    • v.27 no.5
    • /
    • pp.275-280
    • /
    • 2011
  • Automotive wheel bearing grease helps to reduce stresses and prevent wear of wheel bearings. But it is easily contaminated by water and other contaminants. In this study, we investigated the property change of automotive wheel bearing grease under water contamination. The result showed that some properties such as dropping point, work penetration and oxidation stability were not influenced by water content. However, most of properties such as work stability, water washout characteristics, leakage tendency, oil separation, evaporation loss and rust protection became worse after water was added. This is thought that added water makes the interaction weak between thickener and base oil of grease.

A Model of Authority Management for the Protection of Personal Information in OLAP (OLAP 환경에서 개인정보보호를 위한 개인정보 분리 권한관리 모델)

  • Kim, Hyoung-Gyu;Kim, Min-Ho;Kwon, Jung-Sook;Choi, Yong-Lak
    • Journal of Information Technology Services
    • /
    • v.13 no.2
    • /
    • pp.163-172
    • /
    • 2014
  • Personal information has been stolen continuously and it is also affected from development of the Internet. So the government requires that companies spend more effort for protecting customers' personal information. The OLAP server also should meet this requirement, but it is hard to satisfy for the authority management. The OLAP server must use personal information to extract required information from database. This thesis suggests a model of separating between general information and personal information, so this model can help to minimize the leakage of personal information. The model is implemented and tested as a prototype. This prototype can prove that the new model is better than the original one. This study presents that the authority management on the separation between personal information and general information helps protect the personal information of customers.

Development of the Ubiquitous-based Intelligent Digital Switchgear Panel for Home Automation (유비쿼터스 기반의 주택 자동화용 디지털 분전반 개발)

  • Ko, Yun-Seok;Kim, Ho-Yong;Yun, Seok-Yeul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.741-747
    • /
    • 2008
  • This paper proposes a new concept of IDSP(Intelligent Digital Switchgear Panel) which can solve the problem of the safety, the reliability and the convenience to correspond to the requirement of the general electric customer or electric power company under the ubiquitous-based home automation environments. By analyzing their requirement functions, a 32-bit micro processor is adopted as main controller to support the designed functions efficiently. The DSP-based single phase power management device is utilized to collect the electric power information and the ethernet convertor to communicate through internet among the IDSPs and the remote computer system. In the proposed IDSP, the several functions are implemented such as the earth leakage level display and waveform transmission, the electric fee display, the voltage management, the load management and the load control function. Finally, the prototype of the IDSP is made experimently based on the designed results, and then the effectiveness is verified by testing its basic functions.

Enhancement of Internal Control by expanding Security Information Event Management System

  • Im, DongSung;Kim, Yongmin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.8
    • /
    • pp.35-43
    • /
    • 2015
  • Recently, internal information leaks is increasing rapidly by internal employees and authorized outsourcing personnel. In this paper, we propose a method to integrate internal control systems like system access control system and Digital Rights Managements and so on through expansion model of SIEM(Security Information Event Management system). this model performs a analysis step of security event link type and validation process. It develops unit scenarios to react illegal acts for personal information processing system and acts to bypass the internal security system through 5W1H view. It has a feature that derives systematic integration scenarios by integrating unit scenarios. we integrated internal control systems like access control system and Digital Rights Managements and so on through expansion model of Security Information Event Management system to defend leakage of internal information and customer information. We compared existing defense system with the case of the expansion model construction. It shows that expanding SIEM was more effectively.

A Study on Cloud-Based Secure File Management Security Solutions According yo Information Protection Needs (정보보호 필요에 따른 클라우드 기반의 안전한 파일관리 보안솔루션 연구)

  • Kim, Hee-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.243-250
    • /
    • 2019
  • In this paper, we develop a Secure File Management Security(: SFMS) based on media in a cloud environment to encrypt and decrypt cloud data on a computer using a Bluetooth - based cryptographic module. The Bluetooth cipher module makes it easy to browse files stored in the cloud, but it is never possible to browse without a module. It is a solution that fundamentally blocks the problems such as hacking and leakage of personal data that have recently become an issue.

Non-conservative Management of Chylothorax

  • Ahn, Hyo Yeong;I, Hoseok
    • Journal of Chest Surgery
    • /
    • v.54 no.4
    • /
    • pp.325-329
    • /
    • 2021
  • Chylothorax is caused by lymphatic leakage, which can develop after thoracic surgery and is associated with cancer. Although prospective randomized trials have not been performed, radiological interventions have been performed in several cases with persistent chylothorax, adjunct to 2 weeks of conservative management. The success rate of such interventions is diverse due to anatomical variations, although the results are promising. However, in cases of treatment failure after cycles of interventions, a team approach may be necessary to determine whether surgical management is warranted.

LPG Cylinder Leak Experiment from Multiple Leak Scenarios (누출종류에 따른 LP가스용기 누출량 실증 실험)

  • Lee, Minkyung;Lee, Kang-Ok;Kim, Young Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.61-66
    • /
    • 2019
  • Unlike NG supplied through pipes, LPG is mainly used for independent storage of cylinders or small storage tanks. As LPG is widely used in islands and underdeveloped areas, accidents due to neglect of safety management are high. Houses and businesses that have LPG accidents are likely to be damaged due to relatively high population density. Therefore, the necessity of strengthening the safety management of LPG is constantly raised. Accordingly, in 1996, Korea Gas Safety Corporation conducted an LPG leak test. In this study, based on the 96-year experiment, the gas leakage measurement of LPG vessels was conducted by adding several conditions such as outside temperature and pipe condition. Through this, the trend of leakage for various scenarios of LPG leakage was examined. In the case of a gas leak, when the article which may affect the pressure such as a regulator is not connected, the leakage amount is greatly changed by the outside air temperature, and when the regulator is fastened, the influence of the outlet pressure is large. It is expected that the experiment can be used as basic data for determining gas accidents and leakages that may occur later.

A Study on the Development of IoT Inspection System for Gas Leakage Inspection in Kitchen Gas Range Built-in Method (주방 가스레인지 빌트인 방식에서 가스 누출검사를 위한 IoT 검사 시스템 개발에 관한 연구)

  • Kang, Dae Guk;Choi, Young Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.4
    • /
    • pp.283-290
    • /
    • 2022
  • In this study, an IoT inspection system that can be linked with a server was developed using a gas timer and ESP-01 Wi-Fi module installed on a gas valve in the home. The server environment of the gas leak IoT inspection system was installed with APM (Apache, PHP, MySQL) to collect gas pressure data by generation so that leakage checks could be performed. In order to control the gas leak IoT inspection system, the app inventory was used to manage the gas leak check value in real time. In addition, user convenience has been enhanced so that membership management, WiFi settings, and leakage check values can be checked through mobile apps. In order to manage subscribers by region, the user list was checked by logging in in in the administrator mode so that the information on whether or not the leak test was conducted and the results could be provided. In addition, when the user presses the gas leak check button, the pressure is automatically checked, and the measured value is stored in the server, and when a gas leak occurs, the leakage check is performed after alarm and repair so that it can be used if normal. In addition, in order to prevent overlapping membership, membership management can be performed based on MAC addresses.