• Title/Summary/Keyword: Leakage Reduction

Search Result 483, Processing Time 0.029 seconds

A study on the low power architecture of multi-giga bit synchronous DRAM's (Giga Bit급 저전력 synchronous DRAM 구조에 대한 연구)

  • 유회준;이정우
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.11
    • /
    • pp.1-11
    • /
    • 1997
  • The transient current components of the dRAM are analyzed and the sensing current, data path operation current and DC leakage current are revealed to be the major curretn components. It is expected that the supply voltage of less than 1.5V with low VT MOS witll be used in multi-giga bit dRAM. A low voltage dual VT self-timed CMOS logic in which the subthreshold leakage current path is blocked by a large high-VT MOS is proposed. An active signal at each node of the nature speeds up the signal propagation and enables the synchronous DRAM to adopt a fast pipelining scheme. The sensing current can be reduced by adopting 8 bit prefetch scheme with 1.2V VDD. Although the total cycle time for the sequential 8 bit read is the same as that of the 3.3V conventional DRAM, the sensing current is loered to 0.7mA or less than 2.3% of the current of 3.3V conventional DRAM. 4 stage pipeline scheme is used to rduce the power consumption in the 4 giga bit DRAM data path of which length and RC delay amount to 3 cm and 23.3ns, respectively. A simple wave pipeline scheme is used in the data path where 4 sequential data pulses of 5 ns width are concurrently transferred. With the reduction of the supply voltage from 3.3V to 1.2V, the operation current is lowered from 22mA to 2.5mA while the operation speed is enhanced more than 4 times with 6 ns cycle time.

  • PDF

Design of a AC Magnetic Leakage Flux Scan System use in DSP (DSP를 이용한 교류누설 자속 탐상 시스템의 설계)

  • 임형석;이영훈
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.4
    • /
    • pp.75-80
    • /
    • 2003
  • In this paper, we designed add current scan system basically. Although NDT system using AC method in now days had problem with limit of detection rate and limit of device organization, in this paper, we made up these problem so that designed device smaller than system used, reduction of cost of system organization and precision of measuring crack. Also, AC leakage flux system had high accuracy about minute crack in the surface and advantage of designing system easily so that we designed system for concerning about crack of surface. Furthermore, it can be able to detect exact crack of reference in wide area by using DSP320C31 chip to reduce the time of measuring crack.

  • PDF

Root cause analysis of sticking in hydraulically actuated multi-disc friction clutch for ship propulsion (선박 추진용 유압작동식 다판 마찰클러치 고착현상 고장탐구)

  • Jeong, Sang-Hu;Kim, Jeong-Ryeol;Shin, Jae-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.330-336
    • /
    • 2017
  • This study performs a root cause analysis of the sticking that occurs in the hydraulically actuated wet type multi-disc friction clutch in a ship's diesel engine propulsion system that uses rubber elastic coupling. The fishbone method was used to study the sticking through dismantling investigation of the reduction gear and clutch, investigation of the components, and onboard system tests including nondestructive testing. The friction plate sticking is caused by the slip due to friction heat resulting from the leakage of control oil through cracks in the assembled hollow shaft. The friction plate cooling oil also leaks simultaneously through the crack, and partial sticking occurs due to the hot spots in the friction plates. These are caused by insufficient amount of cooling oil due to oil leakage.

A Study on the Optimal Design of Planar Flyback Transformers suitable for Small-size and Low-profile (소형화 및 슬림형에 적합한 평면 플라이백 변압기의 최적 설계에 관한 연구)

  • Na, Hae-Joong;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.828-837
    • /
    • 2020
  • This paper presents the optimal design of planar flyback transformer suitable for small-size and low-profile of AC to DC adapter for 10W tablet. This paper also proposes the injection winding transformer of Hybrid and Drum types capable of the winding method of automatic type and the reduction of transformer size and leakage inductance(Lk) compared to the conventional mass-production flyback transformer with the winding method of manual type. In particular, the injection winding transformer of Drum type proposed in this paper is constructed in a horizontal laying of its transformer to solve the connection problem of copper plate injection winding on the secondary side of the one of Hybrid type. The primary and secondary windings of the injection winding transformer of Hybrid and Drum types used the conventional winding and the copper plate injection winding, respectively. For the injection winding transformer of Hybrid and Drum types proposed in this paper, the optimal design of planar flyback transformer suitable for small-size and low-profile was carried out using Maxwell 2D and 3D tool.

Pain Relief and Associated Factors after a Kyphoplasty for Treating an Osteoporotic Vertebral Compression Fracture (골다공증성 척추 압박 골절에서 풍선 척추 성형술 후 통증의 호전 및 관련 요인에 대한 분석)

  • Koh, Young Do;Kim, Dong Jin
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.186-191
    • /
    • 2014
  • Purpose: The objectives of this study were to assess pain relief according to the time after kyphoplasty and to evaluate the factors affecting pain relief after kyphoplasty in the treatment of a single-level osteoporotic vertebral compression fracture. Methods: A retrospective review of 34 kyphoplasties for single-level osteoporotic vertebral compression fractures was performed. Pain relief was assessed by using the visual analogue scale (VAS) at preoperatively and postoperatively at 6 weeks, 3 months, and 6 months. Associated factors, including age, sex, pain duration, bone mineral density, and cement leakage, were evaluated using the patients' medical records. Statistical analyses were conducted using the paired t-test to assess pain relief and using the independent t-test and Pearson's correlation coefficient to evaluate the relationship between those factors and pain relief. Results: Preoperatively, the mean VAS score was 7.06. Postoperatively, it declined to 3.66 (p=0.001), 2.81 (p=0.001) and 2.24 (p=0.001) at 6 weeks, 3 months and 6 months, respectively. Also, statistically significant pain relief was observed during the periods from 6 weeks to 3 months (p=0.001) and from 3 months to 6 months (p=0.001). However, reduction of the VAS score showed no significant correlation with age, sex, pain duration, bone mineral density, or cement leakage (p>0.05). Conclusion: Our study suggests that a kyphoplasty may be effective in osteoporotic vertebral compression fracture patients with acute pain and that after the kyphoplasty, pain is reduced remarkably for 6 weeks and then continuously for 6 months.

Effects of Post-Annealing on Properties of HfO2 Films Grown by ALD (ALD법으로 성장한 HfO2 박막의 열처리에 따른 특성변화)

  • Lee, J.W.;Ham, M.H.;Maeng, W.J.;Kim, H.;Myoung, J.M.
    • Korean Journal of Materials Research
    • /
    • v.17 no.2
    • /
    • pp.96-99
    • /
    • 2007
  • The effects of post-annealing of high-k $HfO_2$ thin films grown by atomic layer deposition method were investigated by the annealing treatments of $400-600^{\circ}C$. $Pt/HfO_2/p-Si\;MOS$ capacitor structures were fabricated, and then the capacitance-voltage and current-voltage characteristics were measured to analyze the electrical characteristics of dielectric layers. The X-ray diffraction analyses revealed that the $500^{\circ}C-annealed\;HfO_2$ film remained to be amorphous, and the $600^{\circ}C-annealed\;HfO_2$ film was crystallized. The annealing treatment at $500^{\circ}C$ resulted in the highest capacitance and the lowest leakage current due to the reduction of defects in the $HfO_2$ films and non-crystallization. Our results suggest that post-annealing treatments are a critical factor in improving the characteristics of gate dielectric layer.

Development of Simulation Tool to Support Privacy-Preserving Data Collection (프라이버시 보존 데이터 수집을 지원하기 위한 시뮬레이션 툴 개발)

  • Kim, Dae-Ho;Kim, Jong Wook
    • Journal of Digital Contents Society
    • /
    • v.18 no.8
    • /
    • pp.1671-1676
    • /
    • 2017
  • In theses days, data has been explosively generated in diverse industrial areas. Accordingly, many industries want to collect and analyze these data to improve their products or services. However, collecting user data can lead to significant personal information leakage. Local differential privacy (LDP) proposed by Google is the state-of-the-art approach that is used to protect individual privacy in the process of data collection. LDP guarantees that the privacy of the user is protected by perturbing the original data at the user's side, but a data collector is still able to obtain population statistics from collected user data. However, the prevention of leakage of personal information through such data perturbation mechanism may cause the significant reduction in the data utilization. Therefore, the degree of data perturbation in LDP should be set properly depending on the data collection and analysis purposes. Thus, in this paper, we develop the simulation tool which aims to help the data collector to properly chose the degree of data perturbation in LDP by providing her/him visualized simulated results with various parameter configurations.

Comparative Investigation of Interfacial Characteristics between HfO2/Al2O3 and Al2O3/HfO2 Dielectrics on AlN/p-Ge Structure

  • Kim, Hogyoung;Yun, Hee Ju;Choi, Seok;Choi, Byung Joon
    • Korean Journal of Materials Research
    • /
    • v.29 no.8
    • /
    • pp.463-468
    • /
    • 2019
  • The electrical and interfacial properties of $HfO_2/Al_2O_3$ and $Al_2O_3/HfO_2$ dielectrics on AlN/p-Ge interface prepared by thermal atomic layer deposition are investigated by capacitance-voltage(C-V) and current-voltage(I-V) measurements. In the C-V measurements, humps related to mid-gap states are observed when the ac frequency is below 100 kHz, revealing lower mid-gap states for the $HfO_2/Al_2O_3$ sample. Higher frequency dispersion in the inversion region is observed for the $Al_2O_3/HfO_2$ sample, indicating the presence of slow interface states A higher interface trap density calculated from the high-low frequency method is observed for the $Al_2O_3/HfO_2$ sample. The parallel conductance method, applied to the accumulation region, shows border traps at 0.3~0.32 eV for the $Al_2O_3/HfO_2$ sample, which are not observed for the $Al_2O_3/HfO_2$ sample. I-V measurements show a reduction of leakage current of about three orders of magnitude for the $HfO_2/Al_2O_3$ sample. Using the Fowler-Nordheim emission, the barrier height is calculated and found to be about 1.08 eV for the $HfO_2/Al_2O_3$ sample. Based on these results, it is suggested that $HfO_2/Al_2O_3$ is a better dielectric stack than $Al_2O_3/HfO_2$ on AlN/p-Ge interface.

PLASMA POLYMERIZED THIN FILMS GROWN BY PECVD METHOD AND COMPARISON OF THEIR ELECTROCHEMICAL PROPERTIES

  • I.S. Bae;S.H. Cho;Park, Z. T.;Kim, J.G.;B. Y. Hong;J.H. Boo
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.119-119
    • /
    • 2003
  • Plasma polymerized organic thin films were deposited on Si(100) glass and Copper substrates at 25 ∼ 100 $^{\circ}C$ using cyclohexane and ethylcyclohexane precursors by PECVD method. In order to compare physical and electrochemical properties of the as-grown thin films, the effects of the RF plasma power in the range of 20∼50 W and deposition temperature on both corrosion protection efficiency and physical properties were studied. We found that the corrosion protection efficiency (P$\_$k/), which is one of the important factors for corrosion protection in the interlayer dielectrics of microelectronic devices application, was increased with increasing RF power. The highest P$\_$k/ value of plasma polymerized ethylcyclohexane film (92.1% at 50 W) was higher than that of the plasma polymerized cyclohexane film (85.26% at 50 W), indicating inhibition of oxygen reduction. Impedance analyzer was utilized for the determination of I-V curve for leakage current density and C-V for dielectric constants. To obtain C-V curve, we used a MIM structure of metal(Al)-insulator(plasma polymerized thin film)-metal(Pt) structure. Al as the electrode was evaporated on the ethylcyclohexane films that grew on Pt coated silicon substrates, and the dielectric constants of the as-grown films were then calculated from C-V data measured at 1㎒. From the electrical property measurements such as I-V ana C-V characteristics, the minimum dielectric constant and the best leakage current of ethylcyclohexane thin films were obtained to be about 3.11 and 5 ${\times}$ 10$\^$-12/ A/$\textrm{cm}^2$ and cyclohexane thin films were obtained to be about 2.3 and 8 ${\times}$ 10$\^$-12/ A/$\textrm{cm}^2$.

  • PDF

A Study on the Effect of Applying Water Seepage Lowering Method Using Swelling Waterstop for Expansion Joint in the Concrete Dam (콘크리트 댐에서 수축이음부의 수팽창성 차수재를 이용한 침투저감 공법 적용효과 연구)

  • Han, Kiseung;Lee, Seungho;Kim, Sanghoon;Kim, Sejin;Pai, Sungjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.10
    • /
    • pp.21-29
    • /
    • 2021
  • Most concrete gravity-type dams in and out of the country were constructed by column method to control cracks caused by concrete hydration heat generated during construction, resulting in a certain level of leakage after impoundment through various causes, such as contraction joints and construction joints. However, due to the characteristics of concrete structures that shrink and expand according to temperature, concrete dams have vertical joints and drains to allow penetration. PVC waterproof shows excellent effects in completion of the dam, which however increases the possibility of interfacial failure due to different thermal expansion. Other causes of penetration may include problems with quality control during installation, generation of cracks due to heat of hydration of concrete, waterproofing methods, etc. In the case of Bohyunsan Dam in Yeongcheon, North Gyeongsang Province, the amount of drainage in the gallery was checked and underwater, and it was confirmed that there are many penetrations from drainage holes connected to vertical joints, and that some of the PVC waterproofs are not fully operated. As a new method to prevent penetration through vertical joints, D.S.I.M. (Dam Sealing Innovation Method) developed by World E&C was applied to Bohyunsan Dam and checked the amount of drainage in the gallery. As a result of first testing three most leaking vertical joints, the drain in the gallery was reduced by 87% on the average and then applied to the remaining 13 locations, which showed a 83% reduction effect based on the total drain in the gallery. Summing up these results, it was found that D.S.I.M. preventing water leakage from the upstream face is a valid construction method to reduce the water see-through and penetration quantity seen in downstream faces of concrete dams. If D.S.I.M. is applied to other concrete dams at domestic and abroad, it is expected that it will be very effective to prevent water leakage through vertical joints that are visible from downstream faces.