• Title/Summary/Keyword: Leakage Current Waveforms

Search Result 16, Processing Time 0.01 seconds

Suppression of Leakage Current and Distortion in Variable Capacitance Devices and their Application to AC Power Regulators

  • Katsuki, Akihiko;Oki, Takuya
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.66-73
    • /
    • 2016
  • The quantity of alternating current (AC) leakage and the value of distortion factor in capacitor currents are discussed with regard to a new power component called variable capacitance device (VCD). This component has terminals for controlling its capacitance. Nonlinear dielectric characteristics are utilized in this device to vary the capacitance. When VCD operates in an AC circuit, the AC leakage from this device through direct current (DC) control voltage source increases according to the conditions of DC control voltage and so on. To solve this problem, we propose techniques for suppressing AC leakage. Although VCD has strong nonlinear characteristics, the current through the capacitor is not distorted significantly. The relations between AC leakage and the distortion in current waveforms are investigated. An application example for an AC power regulator is also introduced to evaluate the distortion in waveforms.

Harmonics Analysis of Leakage Current Waveforms and Surface Discharge for EPDM Polymer Insulator (EPDM 고분자 애자에 대한 표면방전 및 누설전류파형의 고조파분석)

  • 박재준;양태규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.9
    • /
    • pp.1013-1021
    • /
    • 2004
  • This paper presents the results of spectrum analysis of leakage current waveforms on contaminated polymer insulators under fog conditions. This is a basic study on development of a monitoring for aging degree and surface pollution state using distortion rate(%) of 3rd and 5th harmonics according fundamental frequency[60Hz] under environment conditions. Arcing on the surface was always associated with distortion in the leakage current ; hence the low frequency components of the leakage current can be used as a means to evaluate the surface degradation. The results indicate that the distortion rate by spectrum analysis is available for the monitoring of contamination condition of EPDM Polymer insulators.

Leakage Current Waveforms of Outdoor Polymeric Insulators and Possibility of Application for Diagnostics of Insulator Conditions

  • Suwarno Suwarno
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.114-119
    • /
    • 2006
  • This paper reports the investigation results on the leakage currents (LC) on polymeric outdoor insulators. The samples used were EPDM (ethylene prophylene diene monomer) insulators used at 20 kV distribution lines. AC voltage was applied and the LC waveforms were measured under various environmental conditions (humidity and pollution). Digital data of the LC was transferred from a digital storage oscilloscope to a computer for further analysis. The LC waveform parameters such as magnitude and harmonic content (as indicated by the total harmonic distortion (THD)) were analyzed. The experimental results showed that 3rd, 5th and 7th harmonics and higher odd harmonics were observed for symmetrical-distorted LC waveforms while for unsymmetrical-distorted LC waveforms, odd and even harmonics were observed. The LC analysis indicated that there are 5 stages of insulator conditions from normal condition up to flashover correlated with different kind of LC waveforms. The results also showed that in general the magnitude of LC was good enough to show the condition of the insulators. However, under discharge condition (for example as a result of dry band arching) the LC magnitude should be combined by the THD to show a better correlation with the insulator condition. The product between THD and LC magnitude may be used as a diagnostic parameter.

Leakage Current Waveforms and Spectrum Analysis of EPDM Polymer Insulator according to Environment Condition (환경조건에 따른 EPDM 고분자 애자의 누설전류파형과 스펙트럼 분석)

  • Park, Jae-Jun;Kim, Jeong-Boo;Song, Young-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.82-86
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and rain) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonic waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

Waveform analysis of leakage current on silicon insulator for various environment condition variation (환경조건변화에 대한 실리콘애자의 누설전류 파형분석)

  • Park, Jae-Jun
    • The Journal of Information Technology
    • /
    • v.7 no.2
    • /
    • pp.69-76
    • /
    • 2004
  • This paper presents the results of spectral analysis about waveforms and leakage current waveforms on contaminated silicon insulators under various environment conditions.(salt fog, clean fog, rain). The larger the leakage current during 200ms, the higher the power spectrum at 60Hz. If contaminated insulators suffers from high salt density fog, the leakage current occurs with high crest value intermittently, results in the low spectrum. Analysis of leakage current data showed that this electrical activity was characterized by transient arcing behavior contaminants are deposited on the insulator surface during salt fog tests. This provides a path for the leakage current to flow along the surface of the insulator. It is important to have an indication of the pollution accumulation in order to evaluate the test performance of a particular insulator. If the drop in surface resistivity is severe enough, then the leakage current may escalate into service interrupting flashover that degrade power quality.

  • PDF

Diagnosis Technique of Surface Contamination Degree for EPDM Insulator according to Variation of Environment Condition (환경조건의 변화에 따른 EPDM 애자의 표면 오손정도의 진단기술)

  • Park, Jae-Jun;Choi, In-Hyuk;Kim, Jeong-Boo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.10
    • /
    • pp.1132-1141
    • /
    • 2004
  • The waveforms of the leakage currents for the surface discharge according to the degree of salt contamination and the variation of environmental condition on the EPDM polymer insulators, were shown in this paper. The variation phenomena of fundamental wave, 3rd and 5th harmonic waveforms were also shown from the beginning of the applied voltage and to the flashover voltage. To develop the technique of percentage contamination degree of EPDM polymer insulator according to the variation of environmental condition, the distortion degree of 3rd and 5th harmonic wave to the fundamental wave was utilized through the spectrum analysis for the waveforms of leakage current in the simulation of salt and fog test. The fact that distortion degree % of 3rd and 5th harmonics for fundamental wave is a necessary indicator for the assessment of contamination degree for the polymer insulators, was known.

Failure of Earth Leakage Breaker and Power Quality Analysis in Office Buildings (사무용 빌딩에서의 누전차단기 오동작과 전력품질 분석)

  • Lee, Sang-Ick;Yoo, Jae-Geun;Jeong, Jong-Wook;Lim, Yong-Bae;Jeon, Jeong-Chay
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.211-216
    • /
    • 2004
  • This paper presented a actual conditions on a false-tripping of ELB(Electrical Leakage Breaker) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, printers, fax machines, and test equipments in several office buildings. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of in office buildings. Also, power quality measurements such as harmonic currents, voltage and current waveforms and current imbalance were made at various office buildings where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating md tripping characteristics test of ELB when subjected to distorted current waveforms.

  • PDF

Leakage Current Waveforms and Spectrum Analysis on Polymer Insulator of EPDM under Salt fog (SALT FOG시 EPDM고분자애자의 누설전류파형과 스펙트럼분석)

  • 박재준;양태규
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.500-504
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and .am) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonir waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination (ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

Diagnosis Technique of Surface Aging according to Various Environment Condition for Silicon Polymer Insulator (여러환경조건에 의한 Silicon애자의 표면열화 진단기술)

  • Park, Jae-Jun;Jung, Myeong-Yeon;Lee, Seung-Wook;Kim, Jeong-Boo;Song, Young-Chul;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.76-81
    • /
    • 2004
  • This paper presents the results of spectral analysis of leakage current waveforms on contaminated insulators under various fog and environment conditions(salt fog, clean fog, rain) The larger the leakage current during 200ms, the higer the power spectrum at 60Hz. For almost equal maximum current during 200ms, however, the spectrum at 60hz and the odd order harmonics increase emphatically when discharges occur continuously for several half-waves. If contaminated insulators suffers from high salt-density fog, the leakage current occurs with high crest value intermittently, results in the low spectrum. Analysis of leakage current data showed that this electrical activity was characterized by transient arcing behavior contaminants are deposited on the insulator surface during salt fog tests. This provides a path for the leakage current to flow along the surface of the insulator. It is important to have an indication of the pollution accumulation in order to evulate the test performance of a particular insulator. If the drop in surface resistivity is severe enough, then the leakage current may escalate into s service interrupting flashover that degrade power quality.

  • PDF