Prediction of Shielding Performance by Thickness by Comparing the Single and Laminated Structures of Lead-free Radiation Fusion Shielding Sheets (무연 방사선 융합 차폐시트 단일 구조와 적층 구조의 비교를 통한 두께별 차폐성능 예측)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.105-110
    • /
    • 2021
  • Radiation shielding of affinity material, which is widely used in medical institutions, is made in sheet form and is mainly applied to apron. Shielding performance is presented based on lead equivalent, and is presented as 0.25-0.50mmPb. In the case of shielding materials where lead is used as the main material, the shielding performance can be adjusted by thickness due to the excellent machinability of lead. However, eco-friendly shielding sheets are difficult to control shielding performance based on thickness criteria as shielding performance varies depending on the content of shielding materials, the properties of polymeric materials that are base materials, and the technical differences in the process. In this study, shielding sheets were manufactured based on thickness to solve these problems and the shielding performance was compared in this study. As a result, it was shown that the laminated structure shielding sheet was more effective.

Experimental study of the radiation shielding characteristics of new PbO-Na2O-B2O3-BaO glasses

  • M.I. Sayyed;U. Rilwan;K.A. Mahmoud;Mohamed Elsafi
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2437-2443
    • /
    • 2024
  • This work synthesized four glass samples with a fixed ratio of PbO to Na2O and a variable ratio of BaO to B2O3. The linear attenuation coefficient (LAC) (μ, cm-1) and additional attenuator parameters were determined experimentally using a semiconductor detector and different gamma sources. The comparison was carried out between the experimental and the XCOM calculated results, with good agreement emerging between the two results. The impacts of the BaO substituting for the B2O3 on fabricated PNBB glasses' radiation shielding properties were discussed. By increasing the BaO substitution concentration between 10 and 25 mol.%, the LAC μ values (cm-1) increased by 76.60 %, 13.81 %, 12.56 %, and 12.52 % for the respective γ-ray energies of 0.059, 0.662, 1.173, and 1.332 MeV. The μ value reduction with raised gamma energy values increased the values of the calculated half-value thickness (Δ0.5) as a result of the μ and Δ0.5 values' reverse proportionality. Other shielding parameters such as the lead equivalent thickness (Δeq) and radiation protection efficiency were also determined for the present PNBB glass samples.

Comparative analysis of TiO2, Fe2O3, CaO and CuO in borate based glasses for gamma ray shielding

  • Heba Jamal Alasali;U. Rilwan;K.A. Mahmoud;Taha A. Hanafy;M.I. Sayyed
    • Nuclear Engineering and Technology
    • /
    • v.56 no.10
    • /
    • pp.4050-4055
    • /
    • 2024
  • This research intends to utilize melt-quenching technique in order to examine the radiation shielding capability of 10 % Mo, 10 % Na2O, 20 % PbO, and 60 % B2O3 glass system, with varying CaO, TiO2, CuO, Fe2O3 or Mo. XCOM and MCNP simulations were utilized to analyze the radiation shielding properties of the fabricated glasses. The results revealed CuO having the superior MAC of 49.91 cm2/g, then Fe2O3 with 49.24 cm2/g, followed by CaO with 49.10 cm2/g, and TiO2 with 48.49 cm2/g as the least. CuO and Fe2O3 were confirmed to have least HVL compared to CaO and TiO2. The value of the lead equivalent thickness showed fluctuation against the gamma energy, where it raisess within the photoelectric region and falls after the photoelectric region. The data reveal that, the lead equivalent thickness at 0.1 MeV were 7.88 cm, 7.86 cm, 7.81 cm and 7.80 cm for TiO2, Fe2O3, CaO, and CuO in the same order, respectively. The transmission factor (TF) raises as the gamma energy raises, having TiO2 as the highest with 76.068 %, while the radiation protection efficiency dropped as the energy raises.

Scattering Effectiveness of Monoenergetic Neutrons in the Various Shielding Materials

  • Yoo, Young-Soo
    • Nuclear Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.39-45
    • /
    • 1972
  • In neutron shielding, the scattering effect is equally important as the attenuations in shielding materials. In the present study, the scattered dose equivalent was measured using a Rem counter for water, paraffin, borated paraffin, ordinary and heavy concrete, lead, iron, and tissue equivalent material in three different angles: 45$^{\circ}$, 90$^{\circ}$, and 135$^{\circ}$, respectively. The measurements were performed for the neutron, having the energies of 0.5, 1, 2, 5, and 18 MeV, which are produced from the Van do Graaff accelerator. The scattered dose equivalent ratios were increased with increasing the thickness of scattering materials and saturated at a certain thickness although they were different from one to other materials under study. The ratios were large for lead and iron while they were small for the hydrogen containing materials such as water and paraffin etc.

  • PDF

Dose Customized Apron Micro Functional Design Using Convergence Shielding Sheet (융합 차폐시트를 이용한 선량 맞춤형 에이프런 마이크로 기능성 디자인)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.11
    • /
    • pp.119-126
    • /
    • 2021
  • Radiation shielding clothing for medical institutions is used based on lead equivalent of 0.25 mmPb. However, this study intends to study the shielding suit that can guarantee the user's activity while considering the sensitivity of each part of the body. By manufacturing based on eco-friendly shielding material, it was attempted to solve the weight problem and environmental problem of existing lead aprons, and to present the same shielding performance as lead equivalent in thickness. The fabric of the produced shielding sheet was manufactured through a calendar process that adjusts the thickness of the shielding sheet from lead equivalent 0.12 mmPb to 0.32 mmPb. In addition, the usability evaluation of the manufactured shielding clothes was conducted for the subjects who were workers in medical institutions. As a result, the activity became easier and the weight was reduced by 0.26 kg. In the future, it is thought that it is necessary to improve the shielding suit design considering the activity.

Development of Lead Free Shielding Material for Diagnostic Radiation Beams (의료영상용 방사선방호를 위한 무납차폐체 개발)

  • Choi, Tae-Jin;Oh, Young-Kee;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.232-237
    • /
    • 2010
  • The shielding materials designed for replacement of lead equivalent materials for lighter apron than that of lead in diagnostic photon beams. The absorption characteristics of elements were applied to investigate the lead free material for design the shielding materials through the 50 kVp to 110 kVp x-ray energy in interval of 20 kVp respectively. The idea focused to the effect of K-edge absorption of variable elements excluding the lead material for weight reduction. The designed shielding materials composited of Tin 34.1%, Antimon 33.8% and Iodine 26.8% and Polyisoprene 5.3% gram weight account for 84 percent of weight of lead equivalent of 0.5 mm thickness. The size of lead-free shielder was $200{\times}200{\times}1.5\;mm^3$ and $3.2\;g/cm^3$ of density which is equivalent to 0.42 mm of Pb. The lead equivalent of 0.5 mm thickness generally used for shielding apron of diagnostic X rays which is transmitted 0.1% for 50 kVp, 0.9% for 70 kVp and 3.2% for 90 kVp and 4.8% for 110 kVp in experimental measurements. The experiment of transmittance for lead-free shielder has showed 0.3% for 50 kVp, 0.6% for 70 kVp, 2.0% for 90 kVp and 4.2% for 110 kVp within ${\pm}0.1%$. respectively. Using the attenuation coefficient of experiments for 0.5 mm Pb equivalent of lead-free materials showed 0.1%. 0.3%, 1.0% and 2.4%, respectively. Furthermore, the transmittance of lead-free shielder for scatter rays has showed the 2.4% in operation energy of 50 kVp and 5.9% in energy of 110 kVp against 2.4% and 5.1% for standard lead thickness within ${\pm}0.2%$ discrepancy, respectively. In this experiment shows the designed lead-free shielder is very effective for reduction the apron weight in diagnostic radiation fields.

Improvement of the shieldability and lightweight of a radiation protective apron (방사선 방호용 에이프런의 경량화와 차폐능 개선)

  • Kim, Young-Keun;Jang, Young-Ill;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.45-50
    • /
    • 2003
  • In this work, we characterized the shieldability and lightweight of radiation protective aprons which were consisted of various metal(Pb, Sn, Ni, Ti and Cu) by measuring the x-ray dose transmitted through the filters. The transmitted ratio and lead equivalent of various metal were obtained by linear interpolation and the lead equivalent of double layered filters contained Pb layer was determined. The transmitted ratio of the apron(0.25 mmPb) specified in KS B 0845 was 5.2%. The transmitted ratio of the filters at the thickness of 0.6 mm was decreased in the other of Ni(32.60%), Ti(17.75%), Cu(13.25%) and Sn(3.84%). From the results of experimental evaluation for combined filter of Pb and Sn, it was founded that in the case of the first Sn layer, the lead equivalent was higher than that of the first Pb layer. The lead equivalent corresponding to apron of 0.25 mmPb was obtained in the double layered filters of Sn(0.19 mm) - Pb(0.1 mm) and Pb(0.1 mm) - Sn(0.37 mm). Thus, the Sn-Pb filter had the lower weight about 13% than apron of 0.25 mmPb.

  • PDF

Synthesis of barium-doped PVC/Bi2WO6 composites for X-ray radiation shielding

  • Gholamzadeh, Leila;Sharghi, Hamed;Aminian, Mohsen Khajeh
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.318-325
    • /
    • 2022
  • In this study, composites containing undoped and barium-doped Bi2WO6:Ba2+were investigated for their shielding against diagnostic X-ray. At first, Bi2WO6 and barium-doped Bi2WO6 were synthesized with different weight percentages of barium oxide through a hydrothermal process. The as-synthesized nanostructures were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS) and Raman spectroscopy (RS). After that, some shields were generated with undoped and barium-doped Bi2WO6:Ba2+ nanostructure particles incorporated into polyvinyl chloride (PVC) polymer with different thicknesses and 15% weight of the nanostructure. Finally, the prepared samples were exposed to an X-ray tube at 40, 80, and 120 kV voltages, 10 mAs and, 44.5 cm SID (i.e. the distance from the X-ray beam source to the specimen). Linear and mass attenuation coefficients were also calculated for different samples. The results indicated that, among the samples, the one with 7.5 mmol barium-doped Bi2WO6 had the most attenuation at the voltage of 40kV, and the attenuation coefficients would increase with an increase in the amount of barium. The samples with 15 and 17.5 mmol barium-doped Bi2WO6 had higher attenuation than the others at 80 and 120 kV. Moreover, the half-value layer (HVL), tenth-value layer (TVL) and 0.25 mm lead equivalent thickness were calculated for all the samples. The lowest HVL value was for the sample with 7.5 mmol barium-doped Bi2WO6. As the result clearly show, an increment in the barium-doping content leads to a decrease in both HVL and TVL. In every three voltages, 0.25 mm lead equivalent thickness of the barium-doped composites (7.5 mmol and 15 mmol) had less than the other composites. The lowest value of 0.25 mm lead equivalent thickness was 7.5 barium-doped in 40 kV voltage and 15 mmol barium-doped in 80 kV and 120 kV voltages. These results were obtained only for 15% weight of the nanostructure.

A Coarse Mesh Model for Numerical Analysis of Lead Frame Deformation Due to Blanking Residual Stress (블랭킹 잔류응력에 의한 리드프레임 변형 수치해석을 위한 대격자 모델)

  • Kim Yong Yun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.2
    • /
    • pp.133-138
    • /
    • 2005
  • The deformation of sheet metal due to the residual stress during blanking or piercing process, is numerically simulated by means of a commercial finite element code. Two dimensional plain strain problem is solved and then its result is applied to the deformation analysis of the lead frame. The plain strain element is applied to the 2D problem to observe the Von Mises equivalent stress concentration at the both shearing edges. As the punch penetrates into the sheet material, the stress concentration generated on both edges is getting increased to be the shearing surface. The limits of the punching depth applied to the simulation is 16% and 24% of the sheet thickness for the plain strain element and the hexahedral element, respectively. The hexahedral element and the limit of punching depth were applied to the deformation analysis of the lead frame for the blanking process. The FEM results for the lead deformation were very good agreement with the experimental ones. This paper shows that the coarse mesh has enabled to analyze the lead deformation generated due to the blanking mechanism. This simple approach to save the calculation time will be very effective to the design of the blanking tools in industries.

The Image Resolution Compare to Having Lead Plate or Not Lumbar Lateral Projection

  • Kim, Hyun-Soo;Min, Jung-Whan;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.145-151
    • /
    • 2011
  • The purpose of this study is to know some changes of resolution and image if we remove scattered ray using lead plate when doing lumbar lateral projection. Using 3 DR system(2 FD types, 1 CCD type) equipments and 2 film system equipments, we gain the image whether the phantom of abdomen equivalent sticking resolution chart has lead plate or not, whether we do collimation or not. Also, we use ion chamber, measure radiation exposure rate and change to entrance surface dose from it. we gain that images in the greatest condition of taking in clinic. 5 people in this group decoded resolution with our eyes, measured thickness of images and compared them from each equiments. Resolution has difference to size of collimation in DR FD type. Also there is no difference the original image with the new image which we abbreviated mAs. In DR CCD type, resolution didn't have difference whether lead plate is or not and whether we do collimation or not. In film type, existing or nonexisting of lead plate didn't influence on resolution. Lead plate makes the quality of image higher due to reducing scattered ray, it doesn't influence on resolution.

  • PDF