• Title/Summary/Keyword: Lead Ion

Search Result 312, Processing Time 0.021 seconds

The useage of the EPID as a QA tools (EPID의 적정관리 도구로서의 유용성에 관한 연구)

  • Cho Jung Hee;Bang Dong Wan;Yoon Seong Ik;Park Jae Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.16-21
    • /
    • 1999
  • Purpose : The aim of this study is to conform the possibility of the liquid type EPID as a QC tools to clinical indication and of replacement of the film dosimetry. Aditional aim is to describe a procedure for the use of a EPID as a physics calibration tool in the measurements of radiation beam parameters which are typically carried out with film. Method & Materials : In this study we used the Clinac 2100c/d with EPID. This system contains 65536 liquid-filled ion chambers arranged in a $256{\times}256$ matrix and the imaging area is $32.5{\times}32.5cm$ with liquid layer thickness of 1mm. The EPID was tested for different field sizes under typical clinical conditions and pixel values were calibrated against dose by producing images using various thickness of lead attenuators(lead step wedge) using 6 & 10MV x-ray. We placed various thickness of lead on the table of linear accelerator and set the portal vision an SDD of 100cm. To acquire portal image we change the field size and energy, and we recorded the average pixel value in a $3{\times}3$ pixel region of interest(ROI) at field center was recorded. The pixel values were also measured for different field sizes in order to evaluate the dependence of pixel value on x-ray energy spectrum and various scatter components. Result : The EPID, as a whole, was useful as a QA tool and dosimetry device. In mechanical check, cross-hair centering was well matched and the error was less than ?2mm and light/radiation field coincidence was less than 1mm also. In portal dosimetry the wider the field size the the higher the pixel value and as the lead thickness increase, the pixel value was exponentially decreased. Conclusions : The EPID was very suitable for QA tools and it can be used to measure exit dose during patients treatment with reasonable accuracy. But when indicate the EPID to clincal study deep consideration required

  • PDF

Evaluation of dose variation at the vertex during Total Skin Electron Beam (전신 피부 전자선 조사(TSEB)시 두정부(Vertex)에서의 선량 변화 평가)

  • Jeon Byeong-Chul;An Seung-Kwon;Lee Sang-Gyu;Kim Joo-Ho;Cho Kwang-Hwan;Cho Jung-Hee;Park Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.112-116
    • /
    • 2000
  • Purpose : The vertex scalp is always tangentially irradiated during total skin electron beam(TSEB) This study was discuss to the dose distribution at the vertex scalp and to evaluate the use of an electron reflector. positioned above the head as a means of improving the dose uniformity. Methods and Materials Vetex dosimetry was performed using ion-chamber and TLD. Measurements were 6 MeV electron beam obtained by placing an acrylic beam speller in the beam line. Studies were performed to investigate the effect of electron scattering on vertex dose when a lead reflector $40{\times}40cm$ in area, was positioned above the phantom. Results : The surface dose at the vertex, in the without of the reflector was found to be less than $37.8\%$ of the skin dose. Use of the lead reflector increased this value to $62.2\%$ for the 6 MeV beam. Conclusion : The vertex may be significantly under-dosed using standard techniques for total skin electron beam. Use of an electron reflector improves the dose uniformity at the vertex and may reduce or eliminate the need for supplemental irradiation.

  • PDF

Influence of Competing Ions and Metabolic Inhibitors on Heavy Metal Accumulation in the Cell of Heavy Metal-Tolerant Microorganisms (중금속내성균의 중금속 축적에 미치는 경쟁이온 및 대사저해제의 영향)

  • Cho, Ju-Sik;Lee, Hong-Jae;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.2
    • /
    • pp.142-148
    • /
    • 1997
  • This study was performed to develop the biological treatment technology of wastewater polluted with heavy metals. Heavy metal-tolerant microorganisms, such as Pseudomonas putida, P. aeruginosa, P. chlororaphis and P. stutzeri possessing the ability to accumulate cadmium, lead, zinc and copper, respectively, were isolated from industrial wastewaters and mine wastewaters polluted with various heavy metals. The effect of competing ions and metabolic inhibitors on heavy metal accumulation in the cells was investigated. Heavy metal accumulation into cells was drastically decreased in the presence of competing cation, $Al^{3+}$, and also decreased, at a lesser extent, in the presence of competing anions, $CO_3\;^{2-}$ and $PO_4\;^{2-}$. But heavy metal accumulation was not influenced generally in the presence of the other rations and anions. The accumulation of Cd, Zn or Cu by Cd-, Zn- or Cu-tolerant microorganism was remarkably decreased in the presence of metabolic inhibitors, but the accumulation of Pb by Pb-tolerant microorganism was little affected in the presence of metabolic inhibitors. These results suggested that the accumulation of Cd, Zn or Cu by Cd-, Zn- or Cu-tolerant microorganism was concerned with the biological activity depending on energy, and the accumulation of Pb by Pb-tolerant microorganism depended on not the biological activity but the physical adsorption on the cell surface. Each heavy metal-tolerant microorganism also exhibited some ability to accumulate the other heavy metals in solution containing equal concentrations of cadmium, lead, zinc and copper, when measured at 48 hours after inoculation of the microorganisms, but the accumulation rates were somewhat low as compared to the accumulation rates of heavy metal fitting to each tolerance. These results suggested that the accumulation of each heavy metal by each heavy metal-tolerant microorganism was a selective accumulation process.

  • PDF

Preparation of Acrylic Acid Grafted Polypropylene by Electron Beam Irradiation and Heavy Metal Ion Adsorption Property (전자선 조사를 이용한 아크릴산이 그라프트된 폴리프로필렌의 제조 및 중금속 이온 흡착 특성)

  • Cheon, Ja young;Jeun, Joon-pyo
    • Composites Research
    • /
    • v.32 no.6
    • /
    • pp.335-341
    • /
    • 2019
  • In this study, an acrylic acid (AAc) was grafted on a polypropylene (PP) nonwoven fabric using electron beam irradiation. Electron beam grafting was carried out under various conditions to produce AAc grafted PP (PP-g-AAc) nonwoven fabric having a grafting yield of about 50% at radiation dose of 100 kGy and a monomer concentration of 60%. The physical and chemical properties of PP-g-AAc nonwoven fabric were evaluated by SEM, ATR-FTIR, thermal analysis and tensile strength. The morphology of PP and PP-g-AAc nonwoven fabric confirmed by SEM showed no significant change, and it was judged that AAc was introduced into PP nonwoven fabric from ATR-FTIR. PP-g-AAc nonwoven fabric showed an increase in tensile strength and a decrease in tensile strain compared to PP nonwoven fabric. However, since change of value is not significant, it is considered that there is no significant influence on the physical characterization. Adsorption experiments of PP-g-AAc nonwoven fabric on various ions showed selective adsorption behavior for lead ion. In conclusion, the electron beam radiation-induced PP-g-AAc nonwoven fabric is expected to be applied as an effective adsorbent for the adsorption of lead ions.

Formation and Dissociation Kinetics of Tetraaza-Crown-Alkanoic Acid Complexes of Cerium(Ⅲ)

  • 최기영;김동원;정용순;김창석;홍춘표;이용일
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.6
    • /
    • pp.671-676
    • /
    • 1998
  • The formation and dissociation rates of $Ce^{3+}$ Complexes of the 1,4,7,10-tetraaza-13,16-dioxacyclooctadecane-NN', N",N"'-tetraacetic acid (1), 1,4,7,10-tetraaza-13,16-dioxacyclooctadecane-N,N',N",N"'-tetramethylacetic acid (2), and 1,4,7,10-tetraaza-13,16-dioxacyclooctadecane-N,N',N",N"'-tetrapropionic acid (3) have been measured by the use of stopped-flow spectrophotometry. Observations were made at 25.0±0.1 ℃ and at an ionic strength of 0.10 M $NaClO_4$. The complexation of $Ce^{3+}$ ion with 1 and 2 proceeds through the formation of an intermediate complex $(CeH_3L^{2+})^*$ in which the $Ce^{3+}$ ion is incompletely coordinated. This may then lead to be a final product in the rate-determining step. Between pH 4.76 and 5.76, the diprotonated $(H_2L^{2-})$ from is revealed to be a kinetically active species despite of its low concentration. The stability constants $(logK(CeH_3L^{2+}))$ and specific water-assisted rate constants $(k_{OH})$ of intermediate complexes have been determined from the kinetic data. The dissociation reactions of $Ce^{3+}$ complexes of 1, 2, and 3 were investigated with $Cu^{2+}$, ions as a scavenger in acetate buffer. All complexes exhibit acid-independent and acid-catalyzed contributions. The effect of buffer and $Cu^{2+}$ concentration on the dissociation rate has also been investigated. The ligand effect on the dissociation rate of $Ce^{3+}$ complexes is discussed in terms of the side-pendant arms and the chelate ring sizes of the ligands.

Effect of Acclimation Methods on Physiological Status of Pacific White Shrimp Litopenaeus vannamei Bred in Low Salinity Biofloc (저염분 바이오플락에서 사육한 흰다리새우(Litopenaeus vannamei)의 해수 순치방법에 따른 혈장성분 및 혈장삼투압 비교)

  • Jeon, Yu-Hyeon;Lee, Jong-Min;Kim, Su Kyung;Kim, Su-Kyoung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.5
    • /
    • pp.761-768
    • /
    • 2021
  • This study was carried out to identify an effective method to acclimate low-salinity (4 psu) bred Litopenaeus vannamei (mean body weight 16±3.3 g) to sea water. The fast acclimation group (FA) was directly exposed to filtered sea water (32 psu) while the slow acclimation group (SA) was exposed to a slow increase in salinity. Shrimps were sampled at 0, 1, 3, 6, 12, 24 and 48 h for plasma analyses. The plasma components between experimental groups did not show significant differences. The hemolymph osmolality (HO) in FA increased significantly after 1 h (P<0.05), while in SA it started to increase slowly only at 24 h and reached a similar level to that of FA at 48 h. The levels of Na+ and Mg2+ ions were significantly different between the two treatments (P<0.05), but there was no significant difference in Ca2+ ion levels. We found that the different methods of acclimation of L. vannamei to sea water do not affect the plasma components significantly, but lead to changes in the HO and ion levels, it is considerable to acclimate gradually for at least two days.

Numerical Analysis on Thermal-Induced Degradation of n-i-p Structure Perovskite Solar Cells Using SCAPS-1D (SCAPS-1D 시뮬레이션을 이용한 n-i-p 구조 페로브스카이트 태양전지의 열적 열화 원인 분석)

  • Kim, Seongtak;Bae, Soohyun;Jeong, Younghun;Han, Dong-Woon;Kim, Donghwan;Mo, Chan Bin
    • Current Photovoltaic Research
    • /
    • v.10 no.1
    • /
    • pp.16-22
    • /
    • 2022
  • The long-term stability of PSCs against visual and UV light, moisture, electrical bias and high temperature is an important issue for commercialization. In particular, since the operation temperature of solar cell can rise above 85℃, a study on thermal stability is required. In this study, the cause of thermal-induced degradation of PSCs was investigated using the SCAPS-1D simulation tool. First, PSCs of TiO2/CH3NH3PbI3/Spiro-OMeTAD/Au structure were exposed to a constant temperature of 85℃ to observe changes in conversion efficiency and quantum efficiency. Because the EQE reduction above 500 nm was remarkable, we simulated PSCs performance as a function of lifetime, doping density of perovskite and spiro-OMeTAD. Consequently, the main cause of thermal-induced degradation is considered to be the change in the perovskite doping concentration and lifetime due to ion migration of perovskite.

Tracking of Stem Cells from Human Exfoliated Deciduous Teeth Labeled with Molday ION Rhodamine-B during Periodontal Bone Regeneration in Rats

  • Nan Zhang;Li Xu;Hao Song;Chunqing Bu;Jie Kang;Chuanchen Zhang;Xiaofei Yang;Fabin Han
    • International Journal of Stem Cells
    • /
    • v.16 no.1
    • /
    • pp.93-107
    • /
    • 2023
  • Background and Objectives: Chronic periodontitis can lead to alveolar bone resorption and eventually tooth loss. Stem cells from exfoliated deciduous teeth (SHED) are appropriate bone regeneration seed cells. To track the survival, migration, and differentiation of the transplanted SHED, we used super paramagnetic iron oxide particles (SPIO) Molday ION Rhodamine-B (MIRB) to label and monitor the transplanted cells while repairing periodontal bone defects. Methods and Results: We determined an appropriate dose of MIRB for labeling SHED by examining the growth and osteogenic differentiation of labeled SHED. Finally, SHED was labeled with 25 ㎍ Fe/ml MIRB before being transplanted into rats. Magnetic resonance imaging was used to track SHED survival and migration in vivo due to a low-intensity signal artifact caused by MIRB. HE and immunohistochemical analyses revealed that both MIRB-labeled and unlabeled SHED could promote periodontal bone regeneration. The colocalization of hNUC and MIRB demonstrated that SHED transplanted into rats could survive in vivo. Furthermore, some MIRB-positive cells expressed the osteoblast and osteocyte markers OCN and DMP1, respectively. Enzyme-linked immunosorbent assay revealed that SHED could secrete protein factors, such as IGF-1, OCN, ALP, IL-4, VEGF, and bFGF, which promote bone regeneration. Immunofluorescence staining revealed that the transplanted SHED was surrounded by a large number of host-derived Runx2- and Col II-positive cells that played important roles in the bone healing process. Conclusions: SHED could promote periodontal bone regeneration in rats, and the survival of SHED could be tracked in vivo by labeling them with MIRB. SHED are likely to promote bone healing through both direct differentiation and paracrine mechanisms.

Secondary Phase Control of Lithium Ion-Substituted Potassium Niobate Ceramics via Stoichiometry Modification (화학양론 변화를 통한 리튬 이온 치환 니오브산 칼륨 세라믹의 이차상 제어 연구)

  • Tae Soo Yeo;Ju Hyeon Lee;Wook Jo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.5
    • /
    • pp.533-540
    • /
    • 2024
  • In line with the development of electronic devices and technologies, the demand for improving ferroelectric materials' performance is increasing. Since K0.5Na0.5NbO3 (KNN), an eco-friendly ferroelectric material that does not use lead and has a high Curie temperature, it is attracting attention to its usability as a high-temperature dielectric, and various studies are being conducted to increase performance. In a KNN having a perovskite structure, there was a simulation result that the KNN has higher spontaneous polarization when the A-site in which sodium ions exist is replaced with lithium ions. If the simulation results can be proven experimentally, the application range of KNN-based ferroelectric materials will increase. To this end, we tried to manufacture a K1-xLixNbO3 (KLN) with high electrical characteristics by fabricating niobium-deficient and potassium-excessive compositions, which attempt was made to solve the stoichiometry problem by volatilization and suppress secondary phases. If KLN's secondary phase suppression and relative permittivity improvement are successful, it will contribute to meeting the demand for developing electronic devices.

Determination of lead content in the plastic by ICP and AAS using HI reduction - PbSO4 dissolution method (HI 환원-PbSO4용해법을 이용한 ICP와 AAS에 의한 플라스틱 중의 납 정량 방법)

  • Lee, Hyun-Ja;Kim, Sang-Kyung;Lee, Se-Jin;Lee, Hyun-A
    • Analytical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.369-374
    • /
    • 2004
  • Plastic was decomposed with nitric acid after being carbonized by sulfuric acid. Then excess sulfuric acid and nitric acid was removed by evaporating and drying. Precipitated $SO{_4}^{-2}$ ion of $PbSO_4$ was resolved itself into $H_2S$ by HI in hydrochloric acid and was volatilized. Then $Pb^{+2}$ was dissolved and was measured by AAS and ICP. The test for reproducibility using PVC-Pb standard material (690-34610mg/kg) was conducted and the accuracy was more than 99.9% compared with the estimated concentration. The precision by AAS was 99.8% and that of ICP was 99.9%.