• 제목/요약/키워드: Latex gloves

검색결과 18건 처리시간 0.018초

라텍스 장갑과 마이크로 파이버 속장갑 착용 시 손의 피부수분도 분포 (Distribution of Skin Hydration on the Hand while Wearing Latex Gloves and Inner Gloves)

  • 노상현;현철승;이주영
    • 한국의류학회지
    • /
    • 제41권5호
    • /
    • pp.966-976
    • /
    • 2017
  • This study investigated the effects of wearing latex gloves with inner gloves on the skin hydration of the hands. Fifteen young males participated in the following three conditions: bare hand (BH), latex glove (LG), and latex glove with inner glove condition (LGIG) at an air temperature of $28^{\circ}C$ with 50%RH. Subjects typed a book for 120 min. The results were as follows. Skin hydration was greater for LG and LGIG than BH (p<.001), but no difference was found between LG and LGIG. Skin hydration showed greater values on the thenar and dorsum compared to the palm for both LG and LGIG (p<.05). Skin hydration on the thenar increased during the typing for LG and LGIG, but on the dorsum, palm and finger maintained after 40 min typing. There were positive relationships between hand skin hydration and hand temperature (p<.05). Subjects indicated 'much warmer' and 'more humid' for the LG and LGIG compared to the BH (p<.001), but no differences were found between LG and LGIG. In conclusion, wearing inner gloves inside latex gloves did not induce a reduction of skin hydration and hand temperature; however, significant differences were found in all measurements between bare hands and gloved hands.

라텍스 알레르기(Latex Allergy) (Latex Allergy)

  • 황지인
    • 대한간호
    • /
    • 제37권2호
    • /
    • pp.87-92
    • /
    • 1998
  • Immdeiate hypersensitivity reactions to natural rubber and latex products pose a significant threat to patients, healthcare workers, and the general population. The purpose of this study is to summarize the clinical syomptoms of latex rubber allergy and provide guidelines for the management of latex allergy. Contact dermatitis from the nearly constant use of latex gloves during the workday has become a real problem for many health care professionals. Moreover, the patient who come in contact with these gloves or with other latex-containing equipment may show reactons. Far worse than skin problems is life-threatening anaphyaxis, which can be the first indication that a person has latex sensitivity. In conclusion, nurses shold know the latex precautions such as risk factors, adverse reactons to latex, emergent treatment and so on.

  • PDF

Comparison of Hand Grip Strength, Dexterity, and Hand Function According to the Type of Glove

  • Ro, Hyo-Lyun
    • 대한물리의학회지
    • /
    • 제17권3호
    • /
    • pp.11-21
    • /
    • 2022
  • PURPOSE: This study examined the changes in the handgrip strength, dexterity, and hand function according to the presence or absence of gloves and types of gloves. METHODS: Seventy-six adults in their twenties (male: 24, female: 52, mean age 21.04 years) were the subjects of this study. The handgrip strength, dexterity, and hand function were evaluated with bare hands without gloves, poly gloves, and latex gloves. The handgrip strength was measured using a dynamometer, and three pinch strength tests were performed: tip pinch, lateral pinch, and three-jaw pinch. The hand dexterity was evaluated using the Minnesota manual dexterity test, and the hand function was evaluated using the Jabson-Taylor hand function test. RESULTS: There was no difference in the grip strength depending on whether the gloves were worn. The hand grip, dexterity, and hand function showed significant differences according to the type of glove. Regarding the handgrip, dexterity, and hand function, the latex glove had the best function, and the poly glove had the lowest function. CONCLUSION: There was a difference in dexterity among the hand functions but no difference in grip strength according to the type of glove. The results suggest that the use of latex gloves in daily life be recommended.

라텍스 글러브가 시판되는 3종류 부가중합형 실리콘 인상재의 중합에 미치는 영향 (Effect of latex gloves on polymerization inhibition of addition silicone impression materials)

  • 김수화
    • 한국치위생학회지
    • /
    • 제9권3호
    • /
    • pp.369-379
    • /
    • 2009
  • This study investigated the polymerization inhibition effect of latex gloves on addition silicone impression material. Three different kinds of addition silicone impression materials and a natural latex gloves were used in this study. The results were as follows. 1. Compared to the control group, all of those three kinds of impression materials took longer curing time in order of unwashed, alcohol and washed group, on the other hand, degloving group had shorter curing time than control group(p<0.05). 2. By the type of impression materials, there was no significant difference observed between Exafine and Twinz in ungloved group, Exafine and Imprint II in unwashed group, and Exafine and Twinz in degloving group(p>0.05). 3. The degree of polymerization at 6 minutes after mixing impression materials was evaluated by dividing its range into score 1 to 5. All of the impression materials got score 5 in control group and degloving group, which implies perfect polymerization. In unwashed group, most of them appeared to be score 2 while score 3 were most frequently observed in alcohol group and score 4 in washed group. Thus each group showed differences in the degree of polymerization(p<0.05).

  • PDF

안전보호용 절연 고무장갑의 제조 및 특성 (Preparation and Properties of Insulating Rubber Gloves for Safety Protection)

  • 김공수;조석형;김상기
    • Elastomers and Composites
    • /
    • 제36권4호
    • /
    • pp.262-267
    • /
    • 2001
  • 내전압 특성과 항균성을 갖는 절연 고무장갑을 제조하기 위해 천연고무 라텍스 (NRL)와 수분산성 폴리우레탄 (PU) 그리고 4급 아민 키토산 (4N-chitosan)을 배합하여 침지법으로 제조하였다. 절연 고무장갑의 기계적인 특성은 폴리우레탄 함량이 증가할수록 인장강도는 증가하였으나 신장율은 저하되었으며, 노화후 인장강도 및 신장율의 잔존율은 폴리우레탄 함량 증가에 따라 증가하였다. 또한, 리칭시간이 증가할수록 내전압 특성이 증가하였으며, 3시간의 리칭시간에서 10000V의 내전압 성능을 나타내었다. 고무장갑에 4N-chitosan을 첨가한 결과 균이 거의 생존하지 않았다.

  • PDF

Review on Prevalence, Risk Factors, and Research Advancements on the Use of Medical Gloves Concerning Hand Dermatitis Among Health Care Workers

  • Jeevasunthari Gunasegaran;Ying-Ying Teh;Chin-Keong Lim;Shiow-Fern Ng
    • Safety and Health at Work
    • /
    • 제15권2호
    • /
    • pp.129-138
    • /
    • 2024
  • The COVID-19 pandemic has led to a significant surge in glove usage, as recommended by the World Health Organization. Despite efforts to ensure the quality and safety of gloves, glove-associated skin diseases such as hand dermatitis have become ubiquitous, particularly among health care workers. This review discusses the prevalence, causes, and risk factors of hand dermatitis, as well as research efforts in medical gloves in the past decade to overcome glove-related hand dermatitis. Research papers from 2013 to 2022 were reviewed, selecting only 49 relevant papers from the Ovid, PubMed, and Scopus databases. The average prevalence of hand dermatitis among health care workers increased from 21.08% to 37.24% upon the impact of the COVID-19 pandemic. The cases are likely due to allergies to latex proteins, rubber additives, and accelerators commonly found in gloves. Using alternatives to latex gloves, such as accelerator-free and latex-free glove options, can help reduce allergy-induced hand dermatitis. Strict hand hygiene practices, such as frequent hand washing and the use of sanitizers, are also contributing factors in contracting hand dermatitis. Over the past decade, glove research advancements have focused mainly on reducing or immobilizing latex proteins. These include the use of biodegradable dialdehyde, sodium alginate, arctigenin, bromelain, papain, UV-LED, prototype photoreactors, and structure-modified nanosilica with silane A174. Two effective hand dermatitis preventive measures, i.e. an additional layer of glove liners and the use of gentle alcohol-based hand sanitizer, were recommended. These advancements represent promising steps towards mitigating hand dermatitis risks associated with glove usage.

라텍스 장갑의 세척 방법에 따른 세균 감소율 측정 (Bacteria reduction ratio by cleansing methods of latex gloves)

  • 양송이;오정민;송다혜;송보람;강명진;이명선;손가연;오상환
    • 한국치위생학회지
    • /
    • 제14권4호
    • /
    • pp.593-599
    • /
    • 2014
  • Objectives : Latex gloves hygiene is the most effective method to prevent infection of microorganisms and to reduce the incidence of cross infections. The aim of this study was to compare the bacteria reduction ratio of cleansing with water, liquid soap and alcohol gauze. Methods : The left side glove was the control group and the right side was the experimental group. The experimental group washed hand with water, soap, and alcohol gauze. The hand plate was inoculated by the hand and inoculated for 24 hours in $35^{\circ}C$. Results : Washing with water showed that CFU of control group was 1116.9 and that of experimental group was 302.8. Hand washing by water reduced 74.3% of bacteria. Liquid soap revealed that CFU of control group was 619.9 and that of experimental group was 8.3. Hand washing by liquid soap reduced 97.5% of bacteria. Alcohol gauze included 875.2 CFU in control group and 5.8 CFU in experimental group. Washing by alcohol gauze reduced 99.5% of bacteria. Conclusions : Based on the results, the most effective latex gloves cleansing method was recommended as the standardized hand washing with the liquid hand soap and alcohol gauze. The results can be used to improve training strategies for enhancing glove hygiene practice in dental clinic.

A Study on the Physical Properties of Heat resistance and Cut resistance of Coating Gloves for Work

  • Pyo, Kyeong-Deok;Jung, Eugene;Park, Cha-Cheol
    • Elastomers and Composites
    • /
    • 제54권2호
    • /
    • pp.91-96
    • /
    • 2019
  • The purpose of this study was to examine the effect of different yarn twisting methods on physical properties. Plain single jersey structured fabrics were knitted from Kevlar yarn, and from Kevlar/HPPE, and from Kevlar/Basalt fiber, and from Kevlar/Glass fiber and Kevlar/Stainless steel fiber blended and core-spun yarns. and then, The fabrics were coated NBR Latex. The physical properties, including tear strength, modulus, degree of penetration, heat resistance, and cut resistance of the knitted fabrics were investigated and compared. Kevlar/HPPE blended yarn fabrics recorded the highest heat resistance (13 Sec.). and Kevlar/HPPE blended yarn fabrics had good cut resistance (Cut Level 4).

가금류 악성 전염병 감염축 처리자의 보호 장비 착용실태 조사 및 개선에 관한 연구 (A study on wearing practice and improvement of personal protective equipment for participant handling livestock carcass infected with virulent avian infectious agents)

  • 이혜연;임의형;김종원;김원일;강아름;임채웅;홍철운;한지현;강석진;김범석
    • 한국동물위생학회지
    • /
    • 제38권4호
    • /
    • pp.241-248
    • /
    • 2015
  • This study was aimed to investigate factors that affected the status of wearing personal protective equipment (PPE) for handling poultry carcasses with potential exposure to virulent avian infectious agents. A large outbreak of high pathogenic avian influenza (HPAI) occurred in South Korea in 2014. Many public officers participated for euthanizing and handling livestock carcass. However, several safety issues with using PPE were revealed. Therefore, a questionnaire survey was conducted for 340 people who participated euthanasia and carcass disposal in the place where HPAI mainly occurred in 2014. It was found that 31.8% of the respondents had ever taken off their protective equipment during operations because of its inconvenience. The most inconvenient PPE was goggles (54.6%), followed by mask (20.2%), latex gloves (11.6%), shoe covers (5.9%) and protective clothing (5.3%). The main complaints about this individual PPE was unclear sight, damp emitted toward eye, sweating, tearing easily and sweating, respectively. Considering such problems of PPE, new possible directions for improvement of gloves and goggles were suggested. With newly developed rubber coating fabric gloves and conventionally using latex and fabric gloves, H3N2 influenza virus transmission experiment was conducted. Rubber coating fabric gloves showed similar efficiency for blocking virus transmission with latex laboratory gloves and were not easily torn by sharp claws of chicken. In addition, air flow control safety eyewear was suggested to minimize moisture formation. The air flow control system efficiently suppressed moisture formation inside the goggles. Therefore our study will provide more specific directions about new PPE development for safety protection of actual wearers.

Assessment of Semi-Quantitative Health Risks of Exposure to Harmful Chemical Agents in the Context of Carcinogenesis in the Latex Glove Manufacturing Industry

  • Yari, Saeed;Asadi, Ayda Fallah;Varmazyar, Sakineh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권sup3호
    • /
    • pp.205-211
    • /
    • 2016
  • Excessive exposure to chemicals in the workplace can cause poisoning and various diseases. Thus, for the protection of labor, it is necessary to examine the exposure of people to chemicals and risks from these materials. The purpose of this study is to evaluate semi-quantitative health risks of exposure to harmful chemical agents in the context of carcinogenesis in a latex glove manufacturing industry. In this cross-sectional study, semi-quantitative risk assessment methods provided by the Department of Occupational Health of Singapore were used and index of LD50, carcinogenesis (ACGIH and IARC) and corrosion capacity were applied to calculate the hazard rate and the biggest index was placed as the basis of risk. To calculate the exposure rate, two exposure index methods and the actual level of exposure were employed. After identifying risks, group H (high) and E (very high) classified as high-risk were considered. Of the total of 271 only 39 (15%) were at a high risk level and 3% were very high (E). These risks only was relevant to 7 materials with only sulfuric acid placed in group E and 6 other materials in group H, including nitric acid (48.3%), chromic acid (6.9%), hydrochloric acid (10.3%), ammonia (3.4%), potassium hydroxide (20.7%) and chlorine (10.3%). Overall, the average hazard rate level was estimated to be 4 and average exposure rate to be 3.5. Health risks identified in this study showed that the manufacturing industry for latex gloves has a high level of risk because of carcinogens, acids and strong alkalisand dangerous drugs. Also according to the average level of risk impact, it is better that the safety design strategy for latex gloves production industry be placed on the agenda.