• Title/Summary/Keyword: Lateral-type

Search Result 1,274, Processing Time 0.036 seconds

Biceps Femoris Tendon and Lateral Collateral Ligament: Analysis of Insertion Pattern Using MRI (대퇴이두건과 외측 측부인대: 자기공명영상을 이용한 부착형태 유형의 분석)

  • Shin, Yun Kyung;Ryu, Kyung Nam;Park, Ji Seon;Lee, Jung Eun;Jin, Wook;Park, So Young;Yoon, So Hee;Lee, Kyung Ryeol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.225-231
    • /
    • 2014
  • Purpose : The biceps femoris tendon (BFT) and lateral collateral ligament (LCL) in the knee were formerly known to form a conjoined tendon at the fibular attachment site. However, the BFT and LCL are attached into the fibular head in various patterns. We classified insertion patterns of the BFT and LCL using MR imaging, and analyzed whether the LCL attaches to the fibular head or not. Materials and Methods: A total of 494 consecutive knee MRIs of 470 patients taken between July 2012 and December 2012 were retrospectively reviewed. There were 224 males and 246 females, and patient age varied from 10 to 88 (mean, 48.6). The exclusion criteria were previous surgery and poor image quality. Using 3T fat-suppressed proton density-weighted axial images, the fibular insertion patterns of the BFT and LCL were classified into following types: type I (the LCL passes between the anterior arm and direct arm of the BFT's long head), type II (the LCL joins with anterior arm of the long head of the BFT), type III (the BFT and LCL join to form a conjoined tendon), type IV (the LCL passes laterally around the anterior margin of the BFT), and type V (the LCL passes posteriorly to the direct arm of the BFT's long head). Results: Among the 494 cases of the knee MRI, there were 433 (87.65%) type I cases, 21 (4.25%) type II cases, 2 (0.4%) type III cases, 16 (3.23%) type IV cases, and 22 (4.45%) type V cases. There were 26 cases (5.26%) in which the LCL and BFT were not attached into the fibular head. Conclusion: The fibular attachment pattern of the BFT and LCL shows diverse types in MR imaging. The LCL does not adhere to the head in some patients.

Treatment of Atlantoaxial Fractures (제1,2경추골절의 치료)

  • Jin, Sung-Chul;Kim, Sang-Jin
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.164-172
    • /
    • 2006
  • Background: The authors conducted a retrospective study to evaluate the mechanism of injury, the surgical techniques, the clinical features, the combined injuries, the treatment results, and the surgical complications in patients with atlantoaxial fracture/subluxations. Methods: The authors reviewed 71 cervical fracture/dislocations during a four-year period from September 2002 to August 2006. Among them, there were twenty one C1,2 fracture/subluxations. There were thirteen men (mean age : 43.5 years) and eight women (mean age : 50 years). Their follow-up period was at least 6 months, and the mean follow-up period was 9.6 months. Gardner-Wells tongs traction was used in all patients immediately on presentation. Surgical treatment was performed, depending on the pathologic conditions. Results: Of all 21 cases, 14 cases were injured in motor vehicle accidents, 5 were falls, and 2 were miscellaneous. There were four C1 fracture (5.6%), fourteen C2 fracture (66.7%), one C1 and 2 combined fracture (4.8%), and one C1-2 subluxation (4.8%). The C1 fractures in our series were classified as two Jefferson's fractures and two C1 lateral mass fracture. The C2 fractures were classified as one odontoid type I fracture, two odontoid type II fractures, five odontoid type III fractures, one hangman's fracture, and four C2 body tear-drop fractures. Atlantoaxial fractures were associated with six (28.6%) head injuries, four (19.0%) other spinal injuries, two (9.5%) chest injuries, and three (14.3%) spinal cord injuries. Surgical treatment was performed in nine cases, which included anterior odontoid screw fixation in two cases, transarticular screw fixation with iliac bone graft in one case, posterior fixation by using C2 pedicle screw and C3 lateral mass screw in three cases, lateral mass screw fixation C1-2 with iliac bone graft in one case, O(occipito)-C1-3-4 screw fixation in one case, posterior C2-3 wiring with allograft in one case, and halo vest in six cases. Conservative management was used in the rest of the patients in our trials. Bone fusion was complete in all cases. There were no operation-related complication, except one pin site infection in the case of halo vest. Conclusion: In this study, the choice of appropriate treatment according to the fracture types resulted in safe and effective management of unique atlantoaxial fracture/subluxations.

Study on Running Safety of EMS-Type Maglev Vehicle Traveling over a Switching System (상전도흡인식 도시형 자기부상열차의 분기기 주행안전성 연구)

  • Han, Jong-Boo;Lee, Jong Min;Han, Hyung-Suk;Kim, Sung-Soo;Yang, Seok-Jo;Kim, Ki-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.11
    • /
    • pp.1309-1315
    • /
    • 2014
  • The switch for a maglev vehicle should be designed such that the vehicle safely changes its track without touching the guiderail. In particular, a medium-to-low-speed EMS -type maglev train relies heavily on a U-type electromagnet where it generates levitation force and guidance force simultaneously. Therefore, it is necessary to evaluate the safety of the vehicle whenever it passes the switch, as it lacks active control of the guidance force. Furthermore, when the vehicle passes a segmented switch, which is a group of curves made up of connected lines with a small radius of curvature, it may come into mechanical contact with the guiderail owing to the excessive lateral displacement of the electromagnet. The goal of this study is to analyze the influence of a segmented switch on the safety of major design-related variables for achieving improved running safety. We propose a three-dimensional multibody dynamics model composed of two cars with one body. Using the proposed model, we perform a simulation of the lateral air gap, which is one of the measurements of the running safety of the vehicle when it passes the switch. The analyzed design variables are the length between short span girder, the articulation angle, the length between two centers of a fixed girder at its ends, and the number of girders. On the basis of the effects of the considered design variables, we establish an optimized design of a switch with improved safety.

Transduction of Familial Amyotrophic Lateral Sclerosis-related Mutant PEP-1-SOD Proteins into Neuronal Cells

  • An, Jae Jin;Lee, Yeom Pyo;Kim, So Young;Lee, Sun Hwa;Kim, Dae Won;Lee, Min Jung;Jeong, Min Seop;Jang, Sang Ho;Kang, Jung Hoon;Kwon, Hyeok Yil;Kang, Tae-Cheon;Won, Moo Ho;Cho, Sung-Woo;Kwon, Oh-Shin;Lee, Kil Soo;Park, Jinseu;Eum, Won Sik;Choi, Soo Young
    • Molecules and Cells
    • /
    • v.25 no.1
    • /
    • pp.55-63
    • /
    • 2008
  • Amyotrophic lateral sclerosis (ALS) is a progressive neurodegenerative disorder characterized by the selective death of motor neurons. Mutations in the SOD1 gene are responsible for a familial form of ALS (FALS). Although many studies suggest that mutant SOD1 proteins are cytotoxic, the mechanism is not fully understood. To investigate the role of mutant SOD1 in FALS, human SOD1 genes were fused with a PEP-1 peptide in a bacterial expression vector to produce in-frame PEP-1-SOD fusion proteins (wild type and mutants). The expressed and purified PEP-1-SOD fusion proteins were efficiently transduced into neuronal cells. Neurones harboring the A4V, G93A, G85R, and D90A mutants of PEP-1-SOD were more vulnerable to oxidative stress induced by paraquat than those harboring wild-type proteins. Moreover, neurones harboring the mutant SOD proteins had lower heat shock protein (Hsp) expression levels than those harboring wild-type SOD. The effects of the transduced SOD1 fusion proteins may provide an explanation for the association of SOD1 with FALS, and Hsps could be candidate agents for the treatment of ALS.

Racking Property of Light-framed Shear Wall with Hold-down Connector (홀드다운을 적용한 경골목조 벽체의 전단성능)

  • Lee, In-Chan;Park, Chun-Young;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.26-36
    • /
    • 2008
  • As the height of the light-framed building increases, the lateral load and overturn-moment are increased and the possibility of the building overturn becomes larger. Because the shear wall resists lateral load in light-framed building, the reinforcement of shear wall is required. In order to reinforce the light-framed shear wall, using lag screw fastener type (B-HD) and using bolt type (S-HD) hold-down connectors were applied for test. And domestic larch lumbers, $38{\times}140mm$ and $89{\times}140mm$, KS 2nd grade, were used for the stud. The North American OSB panels were used for sheathing panel. Static loads, load speed 6 mm/min, were applied on top of the wall. As a result, shear strength of the wall that using hold-down connector was improved sufficiently. And when applying the S-HD type hold-down connector, stud should be reinforced against weakening by drilled hole. As increasing the number of lag screw, the number of bolt and the product allowable strength, the strength of shear wall that using hold-down connector was also increased. When applying hold-down connector to light-framed building using 38 mm stud, it must be reinforced by enlarging the thickness of stud like as 38 mm doubled column.

The Effect of Forward Head Posture and Tension Type Headache on Neck Movement: For Office Worker

  • Kim, In-Gyun;Lee, Sang-Yeol
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.4
    • /
    • pp.108-111
    • /
    • 2018
  • Purpose: This study examined the effects of the forward head posture and tension type headache on neck movement among office workers. Methods: The subjects were 6 male and 21 female patients composed of a forward head posture group, forward head posture group with a tension type headache and a normal group. Each group consisted of 2 males and 7 females. The cranio-vertebral angle of the head and the angle of motion of the neck were measured. SPSS 23.0 was used for data analysis and one-way ANOVA was performed for the mean comparison of the neck movements in the three groups. Results: The participants had a limitation in the movement of all necks between the forward head posture group and forward head posture with tension type headache group compared to the normal subjects. The forward head posture with tension headache group had limited neck extension and lateral bending compared to the forward head posture group. Conclusion: Office workers have limitations in the movement of the neck when they are accompanied by forward head posture and tension headache. In particular, when accompanied with a tension headache, there is a restriction on the neck extension and side bending. This study is expected to provide basic data for the relief of tension headache and the treatment of forward head posture in office workers.

Analysis of midpalatal miniscrew-assisted maxillary molar distalization patterns with simultaneous use of fixed appliances: A preliminary study

  • Mah, Su-Jung;Kim, Ji-Eun;Ahn, Eun Jin;Nam, Jong-Hyun;Kim, Ji-Young;Kang, Yoon-Goo
    • The korean journal of orthodontics
    • /
    • v.46 no.1
    • /
    • pp.55-61
    • /
    • 2016
  • Skeletal anchorage-assisted upper molar distalization has become one of the standard treatment modalities for the correction of Class II malocclusion. The purpose of this study was to analyze maxillary molar movement patterns according to appliance design, with the simultaneous use of buccal fixed orthodontic appliances. The authors devised two distinct types of midpalatal miniscrew-assisted maxillary molar distalizers, a lingual arch type and a pendulum type. Fourteen patients treated with one of the two types of distalizers were enrolled in the study, and the patterns of tooth movement associated with each type were compared. Pre- and post-treatment lateral cephalograms were analyzed. The lingual arch type was associated with relatively bodily upper molar distalization, while the pendulum type was associated with distal tipping with intrusion of the upper molar. Clinicians should be aware of the expected tooth movement associated with each appliance design. Further well designed studies with larger sample sizes are required.

Optimal Layout of Vehicle Pedals Depending on the Types and Positions of Vehicle Pedals (페달 종류 및 위치에 따른 최적 페달 레이아웃 설정)

  • Choi, Jeong-Pil;Jung, Eui-S.;Jeong, Seong-Wook;Jeong, Seong-Wook
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.91-101
    • /
    • 2007
  • The purpose of this study is to propose an optimal layout for the accelerator and brake pedals in sedan and SUV, and also to compare the pendant-type pedal with organ-type pedal. 12 male subjects participated in the experiment, the subjects were divided into 3 groups according to height percentile(under 50%ile, 50%ile to 75%ile, over 75%ile). Independent variables were seat height (H30), X and Y coordinates of the center of accelerator and brake pedals and the x and y relative distance between two pedals. Dependent variable was subjective ratings for lower body discomfort. The response surface methodology using a central composite design was employed to develop a prediction model for lower body discomfort of each pedal. It is noticeable that the lateral position of the accelerator in all groups was not statistically significant. The optimal locations of both pedals were found to be distinct according to the percentile of subjects. X distance from accelerator to brake of both-type pedals is similar. But Y distance from accelerator to brake of organ-type is less about 2-3cm than that of pedant-type.

Photogrammetric Study on Facial Shape Analysis of Female College Students (영상계측 프로그램을 이용한 여대생 얼굴의 유형분석)

  • 김진숙;이경화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.11
    • /
    • pp.1470-1481
    • /
    • 2004
  • The purpose of this study was to research on facial shape to suggest a quantified data for the domestic apparel and beauty industry. Conducted a measurement research of 278 female college students, We took the photographs of front view and lateral view of the subjects by digital camera and obtained the 69 measurements through the facial measurement program. 264 ,subjects' measurement data were analyzed by various statistical methods such as descriptive analysis, factor analysis and cluster analysis. Using the 69 measurement items,4 factors were selected as key factors for the factor analysis of facial shape, the factors are: \circled1 Front face height \circled2 Side face radial length \circled3 Front face breadth \circled4 Ear height and Gnathion radial length. We categorized the facial shape into four types by cluster analysis. Type 4 is the most common facial shape in female college students: \circled1 Type 1: Round face \circled2 Type 2: Oval face \circled3 Type 3: Square face \circled4 Type 4: Heart shaped face According to the facial shape analysis, facial shape of female college students are consisting of Heart shaped face(34.8%), Round face(29.2%), Square face(23.5%), oval face(12.5%).

Layered-Type Dielectric Waveguide Filter Using Ceramic (세라믹을 이용한 적층형 유전체 도파관 필터)

  • Jang, Young-Soo;Kim, Jong-Chel;Kim, Seung-Wan;Lee, Kie-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.122-127
    • /
    • 2013
  • Layered-type dielectric waveguide filters were designed. As the order of layers increased the fabrication process for dielectric waveguide filters which the resonator parts were connected by the lateral direction has many difficulties. The proposed structure in this report was designed based on the layered-type for the some parts of resonators. The size of layered-type dielectric waveguide filters installed on the PCB surface were reduced at 25% as compared with the usual waveguide filters by using a relative dielectric constant 22.