• Title/Summary/Keyword: Lateral angle reduction

Search Result 71, Processing Time 0.032 seconds

Evaluation of monotonic and cyclic behaviour of geotextile encased stone columns

  • Ardakani, Alireza;Gholampoor, Naeem;Bayat, Mahdi;Bayat, Mahmoud
    • Structural Engineering and Mechanics
    • /
    • v.65 no.1
    • /
    • pp.81-89
    • /
    • 2018
  • Stone column installation is a convenient method for improvement of soft ground. In very soft clays, in order to increase the lateral confinement of the stone columns, encasing the columns with high stiffness and creep resistant geosynthetics has proved to be a successful solution. This paper presents the results of three dimensional finite element analyses for evaluating improvement in behaviour of ordinary stone columns (OSCs) installed in soft clay by geotextile encasement under monotonic and cyclic loading by a comprehensive parametric study. The parameters include length and stiffness of encasement, types of stone columns (floating and end bearing), frictional angle and elastic modulus of stone column's material and diameter of stone columns. The results indicate that increasing the stiffness of encasement clearly enhances cyclic behaviour of geotextile encased stone columns (GESCs) in terms of reduction in residual settlement. Performance of GESCs is less sensitive to internal friction angle and elasticity modulus of column's materials in comparison with OSCs. Also, encasing at the top portion of stone column up to triple the diameter of column is found to be adequate in improving its residual settlement and at all loading cycles, end bearing columns provide much higher resistance than floating columns.

Modified Essex-Lopresti Reduction for the Displaced Intra-articular Calcaneal Fractures (전위된 관절 내 종골 골절에 대한 Essex-Lopresti 변형 정복술)

  • Kwak, Kyoung-Duck;Cho, Hyoun-Oh;Lim, Dae-Hwan;Ahn, Sang-Min;Jang, Jae-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.1
    • /
    • pp.109-114
    • /
    • 2003
  • Purpose: The purpose of this study is to evaluate the effectiveness and indications of the modified Essex-Lopresti reduction in calcaneal fractures. Materials and Methods: We reviewed retrospectively 41 cases of displaced intraarticular calcaneal fractures. The fracture was reduced with Essex-Lopresti technique with modification in compression of the lateral wall with the specially designed compression device instead of the operator's hands. We evaluated the results of treatment by AOFAS scale and the radiographic parameters including the Bohler's angle, calcaneal width, calcaneofibular distance and the congruency of the posterior facet. Results: Boler's angle was restored from 11 to 29.6 degrees on average, heel width was reduced to 112% of contralateral value, the calcaneofibular gap was restored up to 87.9% of contralateral side, and the articular surface of the posterior facet was restored less than 2 mm of step off and less than 2 mm of gap. AOFAS scale averaged 87 points. The quality of reduction was best in Sander's type II fractures. Small sized fragments in type III fractures could not be reduced. The results were better when the reductions were performed within 24 hours of injury. Conclusion: The modified Essex-Lopresti reduction was less invasive, easy to perform, and the results of treatment were similar to those of open reduction; it seemed to be a reasonable alternative for the selected intraarticular calcaneal fractures.

  • PDF

Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture (해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료)

  • Chung, Hyung-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

Treatment of the Intraarticular Calcaneal Fractures and its Complications (관절내 종골 골절 및 합병증에 대한 치료)

  • Chung, Hyung-Jin;Han, Yong-Taek;Song, Seung-Taek;Lee, Chang-Soo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.1
    • /
    • pp.68-77
    • /
    • 2003
  • Purpose: The treatment of calcaneal fractures remains a controversy in orthopaedic field because of its complications. The purpose of this study is to evaluate the efficacy of the treatment of calcaneal fractures and its complications. Materials and Methods: Clinical and radiological results were retrospectively analyzed in 28 patients, 34 cases with fractures of calcaneus which were treated in our department from September 1998 to march 2003. Results: According to the Creighton-Nebraska Foundation Assessment score, there were 3 excellent, 11 good, and 12 fair 6 poor results. Bohler angle was corrected from $8.3^{\circ}$ to $18.3^{\circ}$, Gissane angle was corrected from $121^{\circ}$ to $135^{\circ}$, and calcaneal width was corrected from 46.8mm to 37mm. Conclusion: Open reduction and internal fixation for joint depression type calcaneal fractures thought to be a good method of treatment. Closed reduction and percutaneous axial pinning should be chosed in selected cases of tongue type fractures. In treatment of complicated calcaneal fractures as malunion, subtalar distraction arthrodesis and lateral wall exostectomy will reduce disability of the disease.

  • PDF

Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient (두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가)

  • Kim, kwang suk;Jo, kwang hyun;Choi, byeon ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose : BoS(Base of Skull) Frame, the fixation tool which is used for the proton of brain cancer increases the lateral penumbra by increasing the airgap (the distance between patient and beam jet), due to the collision of the beam of the posterior oblique direction. Thus, we manufactured the fixation tool per se for improving the limits of BoS frame, and we'd like to evaluate the utility of the manufactured fixation tool throughout this study. Materials and Methods : We've selected the 3 patients of brain cancer who have received the proton therapy from our hospital, and also selected the 6 beam angles; for this, we've selected the beam angle of the posterior oblique direction. We' ve measured the planned BoS frame and the distance of Snout for each beam which are planned for the treatment of the patient using the BoS frame. After this, we've proceeded with the set-up that is above the location which was recommended by the manufacturer of the BoS frame, at the same beam angle of the same patient, by using our in-house Bos frame fixation tool. The set-up was above 21 cm toward the superior direction, compared to the situation when the BoS frame was only used with the basic couch. After that, we've stacked the snout to the BoS frame as much as possible, and measured the distance of snout. We've also measured the airgap, based on the gap of that snout distance; and we've proceeded the normalization based on each dose (100% of each dose), after that, we've conducted the comparative analysis of lateral penumbra. Moreover, we've established the treatment plan according to the changed airgap which has been transformed to the Raystation 5.0 proton therapy planning system, and we've conducted the comparative analysis of DVH(Dose Volume Histogram). Results : When comparing the result before using the in-house Bos frame fixation tool which was manufactured for each beam angle with the result after using the fixation tool, we could figure out that airgap than when not used in accordance with the use of the in-house Bos frame fixation tool was reduced by 5.4 cm ~ 15.4 cm, respectively angle. The reduced snout distance means the airgap. Lateral Penumbra could reduce left, right, 0.1 cm ~ 0.4 cm by an angle in accordance with decreasing the airgap while using each beam angle in-house Bos frame fixation tool. Due to the reduced lateral penumbra, Lt.eyeball, Lt.lens, Lt. hippocampus, Lt. cochlea, Rt. eyeball, Rt. lens, Rt. cochlea, Rt. hippocampus, stem that can be seen that the dose is decreased by 0 CGE ~ 4.4 CGE. Conclusion : It was possible to reduced the airgap by using our in-house Bos frame fixation tool for the proton therapy; as a result, it was possible to figure out that the lateral penumbra reduced. Moreover, it was also possible to check through the comparative analysis of the treatment plan that when we reduce the lateral penumbra, the reduction of the unnecessary irradiation for the normal tissues. Therefore, Using the posterior oblique the Brain cancer proton therapy should be preceded by decreasing the airgap, by using our in-house Bos frame fixation tool; also, the continuous efforts for reducing the airgap as much as possible for the proton therapy of other area will be necessary as well.

  • PDF

The Effects of Chiropractic Therapy and Low Back Exercise of University Students in Commuter (카이로프랙틱 요법과 요통 운동 요법이 요추 자세 및 통증 변화에 미치는 영향 비교 - 통학버스 이용 대학생을 대상으로 -)

  • Jung, Han-Suk;Ham, Joo-Hyun;Choi, Seo-Yeon;Jung, Moon-Young
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.15 no.1
    • /
    • pp.77-87
    • /
    • 2014
  • Objectives: The Purpose of this study was to investigate the effects of chiropractic treatment and low back exercise on lumbar lordosis angle, gravity line, range of motion, and pain degree of university students who are taking a commuter bus at least 4 hours of round trip. Methods: A group of 15 participants received chiropractic treatment around the lumbar spine region twice per week for 8 weeks. Another group of 15 participants were treated with low back exercise three times per week for 8 weeks. Results: In the present results, both chiropractic treatment and low back exercise did not affect the change of lumbar lordosis. However, chiropractic treatment also significantly improved the range of the lumbar motion, including Flexion, Extension, Right Lateral Flexion and Left Lateral Flexion(p<0.05), and consequently decreased the pain degree. Low back exercise significantly moved the lumbar gravity line to almost normal scale, and improved the range of the lumbar motion, including Flexion, and Right Lateral Flexion (p<0.05), resulting in the reduction of pain degree, although both chiropractic treatment and exercise treatment did not change the lumbar lordosis angle at the statistically significant. Conclusions: From these results, it can be inferred that chiropractic treatment might be beneficial to alleviating the low back pain of the university students using a commuter bus by improving the range of lumbar motion or stabilizing the lumbar gravity line.

  • PDF

Limited Posterior Approach for the Surgical Treatment of Intraarticular Fracture of Calcaneus (제한적 후방 도달법을 이용한 관절내 종골 골절의 치료)

  • Hyun, Yun-Seok;Song, Kyung-Won;Shin, Sung-Il;Lee, Jin-Young;Lee, Seung-Young;Kim, Gab-Lae;Shin, Kun-Ho;Seo, Eun-Ho;Ban, Tae-Seo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.79-85
    • /
    • 2007
  • Purpose: To evaluate the clinical efficacy of the limited posterior approach for the surgical treatment of intraarticular fracture of calcaneus. Materials and Methods: From March 2000 to February 2006, we studied retrospectively 186 patients, 203 cases who were treated with open reduction and internal fixation through limited posterior approach and were followed up for more than 1 year. The clinical results were evaluated with Creighton-Nebraska score and circle draw test after 1 year. We checked simple AP, lateral, axial and Broden's view preoperatively and 1 year after surgery, and compared $B{\ddot{o}}hler$ angle and Gissane angle. Results: By Creighton-Nebraska score, Sanders type 2 was 86.4, type 3 was 74.3, type 4 was 62.4. And by circle draw test, type 2 was 8.9 cm, type 3 was 7.2 cm, type 4 was 5.9 cm. $B{\ddot{o}}hler$ angle and Gissane angle were $7.6^{\circ}$, $102.4^{\circ}$, and it increased to $23.5^{\circ}$, $128.6^{\circ}$ after postoperative 1 year. Conclusion: Limited posterior approach for the surgical treatment of intraarticular fracture of calcaneus was considered to an effective treatment modality.

  • PDF

Retromandibular reduction of medially dislocated condylar process fractures

  • Lee, Gyu Hyeong;Kang, Dong Hee;Oh, Sang Ah
    • Archives of Plastic Surgery
    • /
    • v.45 no.1
    • /
    • pp.23-28
    • /
    • 2018
  • Background Condylar process fractures account for one-third of all mandibular fractures, and the distal fragment is prone to dislocate to the medial side due to the pulling of the lateral pterygoid muscle. Retromandibular approaches are commonly used, but the intraoperative view becomes limited in medially dislocated fractures. This study summarized a series of cases of retromandibular reduction for medially dislocated condylar process fractures and described our supplementary procedure to realign the dislocated condylar process. Methods Nine patients with medially dislocated condylar process fractures underwent surgical correction from January 2012 to December 2016. In 6 of them, it was possible to realign the fractures with a conventional retromandibular approach, but for 3 cases of severe dislocation to the middle cranial fossa, a supplementary transoral procedure was carried out. The angle difference between the ramus and condyle, ramus height, and maximal mouth opening (MMO) were evaluated. Results All 9 cases were restored to the proper anatomical alignment without any major complications, and postoperative images revealed successful union. The angle difference was $8.94^{\circ}{\pm}4.11^{\circ}$ preoperatively, and $0.99{\pm}0.49^{\circ}$ at the 6-month follow-up. The pretreatment ramus height difference was $6.12{\pm}6.09mm$, and the postoperative difference was $0.18{\pm}0.10mm$. These changes after surgery were statistically significant. The MMO before surgery was $11.44{\pm}3.0mm$, and the postoperative MMO was $37.2{\pm}2.9mm$, reflecting a significant increase after reduction. Conclusions Retromandibular reduction is a useful method in medially dislocated condylar process fractures, and additional transoral assistance should be considered to realign condylar processes that severely dislocate to the middle cranial fossa.

Plate prebending using a three-dimensional-printed model affords effective anatomical reduction in clavicular shaft fractures

  • Hyungsuk Kim;Younsung Jung;Hyun Seok Song
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.397-405
    • /
    • 2023
  • Background: A precontoured plate rarely fits properly within the patient's clavicle and must be bent intraoperatively. This study aimed to determine whether anatomical reduction could be achieved using a plate bent before surgery. Methods: This study included 87 consecutive patients with displaced mid-shaft clavicle fractures who underwent plate fixation and were followed-up for a minimum of 1 year. After exclusions, 39 consecutive patients underwent fixation with a precontoured plate bent intraoperatively (intraoperative bending group), and 28 underwent fixation with the plate bent preoperatively (preoperative bending group). Using free software and a three-dimensional (3D) printer, ipsilateral clavicle 3D-printed models were constructed. Using plain radiographs, the distance between the edge of the lateral inferior cortex and the medial inferior cortex was measured. The angle between the line connecting the inferior cortex edge and the line passing through the flat portion of the superior cortex of the distal clavicle was measured. Results: Mean length differences between the ipsilateral and contralateral clavicle were smaller on both anteroposterior (AP; P=0.032) and axial images (P=0.029) in the preoperative bending group. The mean angular differences on both AP (P=0.045) and axial images (P=0.008) were smaller in the preoperative bending group. No significant differences were observed between the two groups in functional scores at the last follow-up. Conclusions: Smaller differences in length and angle between the ipsilateral and contralateral clavicle, indicative of reduction, were observed in the preoperative bending group. Using the precontoured technique with low expense, the operation was performed more effectively as reflected by a shorter operation time. Level of evidence: III.

The prospective preliminary clinical study of open reduction and internal fixation of mandibular angle fractures using 2 miniplates (하악 우각부 골절 시 2개의 miniplate를 이용한 관혈적 정복술에 대한 전향적 예비 임상연구)

  • Yang, Seung-Bin;Jang, Chang-Su;Kim, Ju-Won;Yim, Jin-Hyuk;Kim, Jwa-Young;Yang, Byoung-Eun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.320-324
    • /
    • 2010
  • Introduction: The placement of a single miniplate is not sufficient to achieve rigid fixation in mandibular angle fractures. It often causes difficulties in reducing the intermaxillary fixation (IMF) period. Consequently, the placement of 2 miniplates is preferable. The intraoral approach in an open reduction and internal fixation (ORIF) of a mandibular angle fracture with 2 miniplates is often challenging. Accordingly, an alternative of transbuccal approach is performed. However, this method leaves a scar on the face and can result in facial nerve injury. This clinical study suggests a protocol that can maintain rigid fixation without a transbuccal approach in mandibular angle fractures. Materials and Methods: The subjects were 7 patients who sustained fractures of the mandibular angle and treated at Department of Oral and maxillofacial surgery, Sacred Heart Hospital, Hallym University. ORIF under general anesthesia was done using the intraoral approach. One miniplate was inserted on external oblique ridge of the mandible, and the other was placed on lateral surface of the mandibular body with contra-angle drill and driver. A radiographic assessment and occlusal contact point examination was carried out before surgery, and 2, 4 and 6 weeks after surgery. Results: The mean operation time was 80 minutes. Regarding the occlusion state, the number of contact points increased after surgery. Paresthesia and infection were reported to be complications before surgery. Conclusion: The placement of 2 miniplates using contra-angle drill for ORIF of mandibular angle fractures allows early movement of the mandible without IMF. We propose this approach to reduce the patients’discomfort and simplify the surgical procedure.