• Title/Summary/Keyword: Lateral Rotation

Search Result 506, Processing Time 0.028 seconds

Behavior of Back Ground of the Laterally Loaded Single Pile (II) (수평하중이 작용하는 단독말뚝의 배면지반의 저항거동 특성(II))

  • Bae, Jong-Soon;Kim, Ji-Seong;Kim, Sung-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.11
    • /
    • pp.61-73
    • /
    • 2009
  • In this study, we grasped the resistance state of the back ground which had a notable influence on computing the lateral resistance of the laterally loaded single pile in the homogeneous ground by the model test. In order to grasp a resistance behavior, we have to know the deformation area of the back ground and the side failure angle other than the rotation point of pile and vertical failure angle of back ground which were proposed by Bae & Kim in 2008. We found out in this test the characteristics of the behavior of the back ground in accordance with the shape and size of the pile and ground density. We examined the interrelationship of the relative density of sand, the size and the sectional shape of the pile as well.

Construction Stage Analysis of Hybrid Composite Cable-Stayed Girder Bridge Using Eccentrically Loaded Derrick Crane (편중 가능한 사장교 가설용 데릭 크레인을 이용한 합성형 복합 사장교 시공 단계 해석)

  • Park, Taekwun;Kim, Moon Kyum;Won, Jong Hwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.277-286
    • /
    • 2010
  • Derrick or caterpillar crane is generally used for the long-span/cable-stayed bridge construction by pre-cast segment lifting from over-land or water transportation. The heavy weight of them, however, could make defects on unstable under-construction structure and, furthermore a method of conventional segment transportation is also able to occur additional time and cost. In this study, in order to improve conventional construction method, the newly developed derrick crane is mainly considered. It could be not only eccentrically loadable on constructing girder but having rotatable boom for segment transportation from back-side. A series of construction stage using developed derrick crane is defined and also its numerical analysis is conducted. To reflect load characteristics of developed derrick crane on construction stage analysis, on/out of service load is separately calculated by considering vertical/lateral rotation range of boom and it is loaded on 4 fixed positions of crane. The derrick crane on this study could be time and cost saving solution for cable-stayed bridge construction and also make contributions to construction load reduction in its process.

Correlations between the Clinical and Ultrasonographic Parameters of Congenital Muscular Torticollis without a Sternocleidomastoid Mass

  • Jisun Hwang;Eun Kyung Khil;Soo Jin Jung;Jung-Ah Choi
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1374-1382
    • /
    • 2020
  • Objective: To determine whether ultrasonography at initial presentation can help assess the clinical severity of congenital muscular torticollis (CMT) in infants without a sternocleidomastoid muscle (SCM) mass. Materials and Methods: This retrospective study included 71 infants aged less than 12 months (4.1 ± 2.3 months) with non-mass CMT. The clinical severity was divided into three grades (groups 1-3) based on the degree of lateral head bending or cervical rotation. The difference (SCM-D) and ratio (SCM-R) between the maximal thickness of the affected and non-affected SCMs were obtained using transverse and longitudinal ultrasonography. The sonographic echotexture and echogenicity of the involved SCM were reviewed. Results: A significant difference was observed in the SCM-D (0.42 ± 0.30 mm in group 1; 0.74 ± 0.50 mm in group 2; 1.14 ± 0.85 mm in group 3; p = 0.002) and SCM-R (1.069 ± 0.067 in group 1; 1.129 ± 0.087 in group 2; 1.204 ± 0.150 in group 3; p = 0.001) among the groups when measured along the longitudinal but not along the transverse ultrasonography plane. The areas under the curves of the SCM-R and SCM-D measured by longitudinal ultrasonography were 0.731 (p < 0.001) and 0.731 (p < 0.001) for group 1 versus groups 2-3. The proportions of heterogeneous echotexture or hyperechogenicity in the involved SCM did not differ significantly among the three clinical groups (all p > 0.05). Conclusion: Ultrasonography can aid in assessing the clinical severity of CMT in infants without an SCM mass at the time of initial diagnosis. The SCM-R and SCM-D helped grade the clinical severity when obtained by longitudinal scan.

Patient Position Verification and Corrective Evaluation Using Cone Beam Computed Tomography (CBCT) in Intensity.modulated Radiation Therapy (세기조절방사선치료 시 콘빔CT (CBCT)를 이용한 환자자세 검증 및 보정평가)

  • Do, Gyeong-Min;Jeong, Deok-Yang;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • Purpose: Cone beam computed tomography (CBCT) using an on board imager (OBI) can check the movement and setup error in patient position and target volume by comparing with the image of computer simulation treatment in real.time during patient treatment. Thus, this study purposed to check the change and movement of patient position and target volume using CBCT in IMRT and calculate difference from the treatment plan, and then to correct the position using an automated match system and to test the accuracy of position correction using an electronic portal imaging device (EPID) and examine the usefulness of CBCT in IMRT and the accuracy of the automatic match system. Materials and Methods: The subjects of this study were 3 head and neck patients and 1 pelvis patient sampled from IMRT patients treated in our hospital. In order to investigate the movement of treatment position and resultant displacement of irradiated volume, we took CBCT using OBI mounted on the linear accelerator. Before each IMRT treatment, we took CBCT and checked difference from the treatment plan by coordinate by comparing it with the image of CT simulation. Then, we made correction through the automatic match system of 3D/3D match to match the treatment plan, and verified and evaluated using electronic portal imaging device. Results: When CBCT was compared with the image of CT simulation before treatment, the average difference by coordinate in the head and neck was 0.99 mm vertically, 1.14 mm longitudinally, 4.91 mm laterally, and 1.07o in the rotational direction, showing somewhat insignificant differences by part. In testing after correction, when the image from the electronic portal imaging device was compared with DRR image, it was found that correction had been made accurately with error less than 0.5 mm. Conclusion: By comparing a CBCT image before treatment with a 3D image reconstructed into a volume instead of a 2D image for the patient's setup error and change in the position of the organs and the target, we could measure and correct the change of position and target volume and treat more accurately, and could calculate and compare the errors. The results of this study show that CBCT was useful to deliver accurate treatment according to the treatment plan and to increase the reproducibility of repeated treatment, and satisfactory results were obtained. Accuracy enhanced through CBCT is highly required in IMRT, in which the shape of the target volume is complex and the change of dose distribution is radical. In addition, further research is required on the criteria for match focus by treatment site and treatment purpose.

  • PDF

Flexural Test of H-Shape Members Fabricated of High-Strength Steel with Considering Local Buckling (국부좌굴을 고려한 고강도 조립 H형강 부재의 휨성능 실험)

  • Lee, Cheol-Ho;Han, Kyu-Hong;Park, Chang-Hee;Kim, Jin-Ho;Lee, Seung-Eun;Ha, Tae-Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.417-428
    • /
    • 2011
  • Depending on the plastic deformation capacity required, structural steel design under the current codes can be classified into three categories: elastic, plastic, and seismic design. Most of the current steel codes explicitly forbid the use of a steel material with a yield strength higher than 450 MPa in the plastic design because of the concerns about its low plastic deformation capacity as well as the lack of test data on local and lateral torsional buckling behavior. In this study, flexural tests on full-scale H-shape members built with SM490A (ordinary steel or benchmark material) and HSB800 (high-strength steel) were carried out. The primary objective was to investigate the appropriateness of extrapolating the local buckling criterion of the current codes, which was originally developed for normal-strength steel, to the case of high-strength steel. All the SM490A specimens performed consistently with the current code criteria and exhibited sufficient strength and ductility. The performance of the HSB800 specimens was also very satisfactory from the strength perspective; even the specimens with a noncompact and slender flange developed the plastic moment capacity. The HSB800 specimens, however, showed an inferior plastic rotation capacity due to the premature tensile fracture of the beam bottom flange beneath the vertical stiffener at the loading point. The plastic rotation capacity that was achieved was less than 3 (or the minimum level required for a plastic design). Although the test results in this study indicate that the extrapolation of the current flange local-buckling criterion to the case of high-strength steel is conservative from the elastic design perspective, further testing together with an associated analytical study is required to identify the causes of the tensile fracture and to establish a flange slenderness criterion that is more appropriate for high-strength steel.

Clinecal Investigation and Acute Complications of Remodelling Plasty of Costochondral Rib Cage For Pectus Excavatum (전흉벽 늑연골의 리모델링 성형술을 이용한 누두흉수술의 임상적 고찰 초기합병증)

  • Her, Keun;Song, Cheol-Min;Jeon, Cheol-Woo;Jang, Won-Ho;Kim, Hyun-Jo;Jeong, Yoon-Seop;Youm, Wook
    • Journal of Chest Surgery
    • /
    • v.35 no.12
    • /
    • pp.882-889
    • /
    • 2002
  • Acute Complications of Remodelling Plasty of Costochondral Rib Cage For Pectus excavatum Recently, Remodelling Plasty of Costochondral Rib Cage has been introduced as an minimally invasive procedure and expanded its application for pectus excavatum. Outcomes and acute complications were reviewed Material and Method: A retrospective survey of 55 patients who underwent Remodelling Plasty of Costochondral Rib Cage from September, 1999 to February, 2002 was conducted to review complications, postoperative treatments, and outcomes. Result: Age ranged from 1 to 27 years(mean 11.4 $\pm$ 7.1). 35(64%) were less than 15-year old and 20(36%) were more than 15-year old. There were 44(80%) Male patients and 11(20%) female patients. Length of hospital stay was 7.8 $\pm$ 2.1 days for less than 15-Y-old group, 10.6 $\pm$ 6.2 days for more than 15-Y-old group(p = 0.042) One substernal bar was inserted in 52 patients and two substernal bars were inserted in 3 patients. As for stabilizer, one lateral side was fastened in 15 patients and both lateral sides were fastened in 6 patients. In the less than 15-Y-old group, 4 patients needed stabilizer, whereas in the more than 15-Y-old group, 18 patients needed stebilizer(s)(p = 0.000). Including all kinds of complications, 28(51 %)patients had postoperative complications. Of them, only 7 patients were treated for complications(C-tube insertion was done in 7 patients and reoperation for bar refixation or removal was done in 3 patients of them). Conclusion: Most complications after Remodelling Plasty of Costochondral Rib Cage For Pectus Excavatum were trivial without treatment although C-tube drainage was needed in some patients. However bar displacement such as rotation and lateral sliding should be corrected as soon as detected in order not to remove the bar(the worst situation).

The Pattern of Initial Displacement in Lingual Lever Arm Traction of 6 Maxillary Anterior Teeth According to Different Material Properties: 3-D FEA (유한요소모델에서 레버암을 이용한 상악 6전치 설측 견인 시 초기 이동 양상)

  • Choi, In-Ho;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.213-230
    • /
    • 2008
  • The aim of this study was to analyze the initial movement and the stress distribution of each tooth and periodontal ligament during the lingual lever-arm retraction of 6 maxillary incisors using FEA. Two kinds of finite element models were produced: 2-properties model (simple model) and 24-properties model (multi model) according to the material property assignment. The subject was an adult male of 23 years old. The DICOM images through the CT of the patient were converted into the 3D image model of a skull using the Mimics (version 10.11, Materialise's interactive Medical Image Control System, Materialise, Belgium). After series of calculating, remeshing, exporting, importing process and volume mesh process was performed, FEA models were produced. FEA models are consisted of maxilla, maxillary central incisor, lateral incisor, canine, periodontal ligaments and lingual traction arm. The boundary conditions fixed the movements of posterior, sagittal and upper part of the model to the directions of X, Y, Z axis respectively. The model was set to be symmetrical to X axis. Through the center of resistance of maxilla complex, a retraction force of 200g was applied horizontally to the occlusal plane. Under this conditions, the initial movements and stress distributions were evaluated by 3D FEA. In the result, the amount of posterior movement was larger in the multi model than in the simple model as well as the amount of vertically rotation. The pattern of the posterior movement in the central incisors and lateral incisors was controlled tipping movement, and the amount was larger than in the canine. But the amount of root movement of the canine was larger than others. The incisor rotated downwardly and the canines upwardly around contact points of lateral incisor and canine in the both models. The values of stress are similar in the both simple and multi model.

A study on Yang Shi Tai Chi Chuan in Bartenieff Fundamentals Perspectives (바티니에프 기본원리를 통해 본 양식 태극권에 관한 연구)

  • Wang, Zhiquan
    • Trans-
    • /
    • v.8
    • /
    • pp.95-127
    • /
    • 2020
  • This research is based on using Bartenieff Fundamentals to analyze the fundamentals of Tai Chi Chuan's movements in order to develop the methods of relaxation from Tai Chi Chuan's principle movement movements It also shows that the two techniques have commonalities in many ways. First of all, taking a philosophical approach on the body movements of Tai Chi Chuan and Bartenieff, for both methods the ultimate goal is the integration of mind and body. In other words, there is a thread of connection between the East's body and mind monism and the west's Body Awareness. Secondly, looking at it from a Breath Support standpoint as used in the Bartenieff method, the two methods both use the breathing to naturally move the body and relax the body. In Tai Chi Chuan the Breath is the basis of life and the strength of the Body. So the breathing of Tai Chi chuan is what makes body and mind communicate, harmonize and integrate. In other words, Breathing in Tai Chi is realized through mental fusion and affects the movements. This is the same as the Breath Support of Bartenieff. It is said that in every aspect the Breath Support of Bartenieff influences the movement and changes both the inner and outer form of the body. Thirdly, looking at the Core Support used in the Bartenieff method, both methods emphasize core. At the same time of moving and being conscious of one's core, the usage of muscles can be deeper rather than superficial and this enables strong and flexible movement. In Tai Chi Chuan abdominal muscles used when one coughs are consciously engaged through abdominal breathing and so strength is collected in the core. When one exercises like that the core becomes more stable and breathing becomes more smooth. Fourthly, analyzing the Rotary Factor used in the Bartenieff Fundamentals, they both use rotary movement to reach the goal of physical relaxation. The rotation factor of Bartenieff allows movement to be easier and more free because of the characteristic of joint exercise where the center axis moved in three dimensions, this is the same in Tai Chi chuan. According to Tai Chi chuan's circle and Spiral Movements, it can achieve the relaxation through switching into a seamless flow and access space as much as possible. Finally, when looking at Developmental Patterning through Bonnie Bainbridge Cohen's Body-Mind Centering Work theory, presented from Bartenieff developmental model are similar with the developmental process of Tai Chi chuan Breath, Core-Distal Connectivity/Navel Radiation, Head-Tail Connectivity/Spinal Movement, Upper-Lower Connectivity/Homologous, Body-Half Connectivity/Homo-Lateral Connectivity, Cross-Lateral Connectivity/Contra-Lateral Connectivity. They are all similar. In other words, in Tai Chi Chuan energy is gathered in the core through breathing, upper and lower body are connected through the spine, not only homo-laterally but also cross-laterally. Through this study the expression of the dance movements can be more natural. Additionally based on the Body Awareness balance usage of the central axis, joints and body can develop the relax technique.

  • PDF

Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT (정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가)

  • Ahn, Min Woo;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Lee, Doo Sang;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.201-208
    • /
    • 2018
  • Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

  • PDF

The effects of maxillary protraction appliance (MPA) depending on vertical facial patterns (수직적 안모 형태에 따른 상악골 전방 견인 장치의 효과 비교)

  • Ryu, Young-Kyu;Lee, Kee-Joon;Oh, Chang-Hun
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.413-424
    • /
    • 2002
  • Preadolescent children with deficient maxillae are suitable candidates for the maxillary protraction appliance(MPA). The theoretical effect of the MPA is protraction or anterior displacement of the maxilla. However, it is known that complex effects such as anterior displacement of the maxillary teeth, downward and backward rotation of the mandible, linguoversion of the mandibular anterior incisors, are known to play a role in improving the Cl III malocclusion. There have been much studies with regard to maxillary protraction, but the different effects of MPAs depending on the vertical facial pattern are not known precisely. This study was based on 67 patients (31 males, 36 females) aged from 6 years 6 months to 13 years 3months, who visited the Dept. of Orthodontics at Yonsei Univ., Dental Hospital and diagnosed as skeletal Class III with maxillary deficiency. They were divided into 3 groups (low, average, high angle groups) depending on genial angle and the SNMP (Go-Gn) angle, respectively. Pretreatment and post-treatment lateral cephalograms were used to compare the effects of MPA and the following conclusions were obtained: 1) A significantly large amount of backward movement of the B point was observed in patients with a low SNMP angle. Those with a high SNMP angle had significant forward movement at A point. 2) The patients with low genial angle had the least forward movement at the A point, and those with a high angle had more forward movement. 3) In comparing the arcTan of the A point, the high angle group showed more horizontal movement while the low angle group showed more vertical movement. 4) There was no significance between the treatment duration of the SNMP and the Genial angle groups.