• Title/Summary/Keyword: Laser accuracy

Search Result 868, Processing Time 0.027 seconds

Proposal of CT Simulator Quality Assurance Items (전산화단층 모의치료장치의 정도관리 항목 제안)

  • Kim, Yon-Lae;Yoon, Young-Woo;Jung, Jae-Yong;Lee, Jeong-Woo;Chung, Jin-Beom
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.367-373
    • /
    • 2021
  • A quality assurance of computed tomography(CT) have done seven items that were water attenuation coefficient, noise, homogeneity, spatial resolution, contrast resolution, slice thickness, artifact using by standard phantom. But there is no quality assurance items and methods for CT simulator at domestic institutions yet. Therefore the study aimed to access the CT dose index(CTDI), table tilting, image distortion, laser accuracy, table movement accuracy and CT seven items for CT simulator quality assurance. The CTDI at the center of the head phantom was 0.81 for 80 kVp, 1.55 for 100 kVp, 2.50 for 120 mm, 0.22 for 80 kVp at the center of the body phantom, 0.469 for 100 kVp, and 0.81 for 120 kVp. The table tilting was within the tolerance range of ±1.0° or less. Image distortion had 1 mm distortion in the left and right images based on the center, and the laser accuracy was measured within ±2 mm tolerance. The purpose of this study is to improve the quality assurance items suitable for the current situation in Korea in order to protect the normal tissues during the radiation treatment process and manage the CT simulator that is implemented to find the location of the tumor more clearly. In order to improve the accuracy of the CT simulator when looking at the results, the error range of each item should be small. It is hoped that the quality assurance items of the CT simulator will be improved by suggesting the quality assurance direction of the CT simulator in this study, and the results of radiation therapy will also improve.

Laser Forming of Sheet Metal by Geometrical Information (기하학적 정보를 이용한 이중곡률 형상의 레이저 성형)

  • Kim, Ji-Tae;Na, Seok-Ju
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.91-93
    • /
    • 2005
  • Forming sheet metal by laser-induced thermal stresses (laser forming) has been extensively studied, and the research has focused on two-dimensional geometries using a multi-pass straight line scan. Recently there came out some useful studies or three-dimensional laser forming which is applied to doubly curved shapes. The task of 3D laser forming sheet metal is to determine a set of process parameters such as laser scanning paths, laser power and scanning speed that will make a given shape. New method for laser forming of a doubly curved surface by using geometrical information was proposed and verified by experiments. This method shows good performance in the sense of calculation time and accuracy compared to the inherent strain method.

  • PDF

Design of 3D Laser Radar Based on Laser Triangulation

  • Yang, Yang;Zhang, Yuchen;Wang, Yuehai;Liu, Danian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.5
    • /
    • pp.2414-2433
    • /
    • 2019
  • The aim of this paper is to design a 3D laser radar prototype based on laser triangulation. The mathematical model of distance sensitivity is deduced; a pixel-distance conversion formula is discussed and used to complete 3D scanning. The center position extraction algorithm of the spot is proposed, and the error of the linear laser, camera distortion and installation are corrected by using the proposed weighted average algorithm. Finally, the three-dimensional analytic computational algorithm is given to transform the measured distance into point cloud data. The experimental results show that this 3D laser radar can accomplish the 3D object scanning and the environment 3D reconstruction task. In addition, the experiment result proves that the product of the camera focal length and the baseline length is the key factor to influence measurement accuracy.

A Study on Performance Evaluation of 3-Axis Pipe Profile-Cutting Machine (3축 파이프 형상 절단기의 성능평가에 관한 연구)

  • Lho, Tae-Jung;Lee, Wook-Jin;Kim, Hwa-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.1955-1960
    • /
    • 2010
  • A performance of CNC 3-axis pipe profile-cutting machine we developed was evaluated by measuring and verifying a positioning accuracy of its feeding unit and a cutting shape accuracy of pipe workpiece. The positioning accuracy was verified by comparing moving distance actuated by PLC motion controller with actual one measured by a laser interferometer. The cutting shape accuracy was also verified by comparing a cutting shape obtained through scanning and 3D modeling the pipe workpiece with that through CL data.

Study of Servo Controller for Improving Position Accuracy of 3D Terrestrial Laser Scanner (지상용 3차원 레이저 스캐너의 측정 위치 정확도 향상을 위한 서보 제어기의 연구)

  • Yu, Jong-Wook;Jeong, Joong-Yeon;Kim, Tae-Hyung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.187-194
    • /
    • 2009
  • This study is to improve position accuracy by selecting proper a servo motor and applying FOC(Field Oriented Control) on developing a 3D terrestrial laser scanner. A 3D terrestrial laser scanner under developing has range of scanning of azimuth 360$^\circ$and elevation 270$^\circ$. It is implemented by precise controlling of a azimuth motor and a elevation motor. In the consequence of study, we have known that position accuracy of the motor can be able to be improved with constant torque of the motor by using FOC(Field Oriented Control). The control technic of the motor is possible to apply a 3D terrestrial laser scanner as well as a robotic total station.

A Study on Precision Measurement of Rock Joint Using 3D-Laser Scanner (3D-Laser scanner를 이용한 암반 절리의 정밀측정에 관한 연구)

  • 이승호;황영철;김세현;심석래;정태영
    • Explosives and Blasting
    • /
    • v.22 no.3
    • /
    • pp.103-111
    • /
    • 2004
  • The existing methods that can be adopted for measuring joints involve either to use borehole or photogrammetry. Due to restricted space, acquisition of data in limited area, and measurement errors, above methods have limitations acquiring the objective and correct results. To get over defects of existing joint measurement methods, joints have been measured using 3D-Laser scanner with accuracy and efficiency. This research aims to investigate an accuracy and applicabiliy of 3D-Laser scanner for measuring rock slope joints. Measurement of rock slope joints has been executed using 3D-Laser scanner & clinometer and then, results from both methods are compared. Results from both methods indicate that they show nearly equal features for joint distributions and numbers of joint information obtained by 3D-Laser scanner are much more than ones measured using clinomer. Therefore, 3D-Laser scanner turns out to be very effective by the fact that it contributes to reduce investigation costs & periods, objectify data from rock slope joints.

A Study on On-line 5 Degrees of Freedom Error Measurement using Laser Optical System (레이져 광학장치를 이용한 온라인 5 자유도 오차측정에 관한연구)

  • 김진상;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.375-378
    • /
    • 1995
  • Although laser interferometer measurement system has the advantage of range and accuracy, the traditional error measurement methods for geometric errors(two straightness and three angular errors) of a machine tool measures error components one at a time. It may also create an optical path difference and affect the measurement accuracy. In order to identify and compensate for geometric error of a moving body, an on-line measurement system for simultaneous detection of the five error components of a moving axis is required. An on-line measurement system with 5 degrees of freedom was developed for geometric error detection. Performance verification of the system was performed on an error generating mechanism. Experimental results show the feasibility of this system for identifying geometric errors of a side of machine tool.

  • PDF

Hardness Estimation of Laser Welded Boron Steel Welds with the Carbon Equivalent (탄소 당량식을 이용한 고강도 보론강의 레이저 용접부 경도 예측)

  • Jeon, In-Hwan;Kim, Cheolhee;Kim, Jae-Do
    • Journal of Welding and Joining
    • /
    • v.34 no.5
    • /
    • pp.1-5
    • /
    • 2016
  • The hardness of laser weldments has been predicted by using several carbon equivalent equations and estimation models. In this study, authors extended the model to boron steel sheets which are adopted for the hot press forming process. four kinds of boron steels with the strengths from 1500 MPa to 1900 MPa were considered and the hardness profiles of weldments was measured from the experiments of this study and the references. The traditional "Kaizu" equation could predict the hardness with an accuracy of -4.9% error although the Kaizu equation does not consider the boron content. Modified carbon equivalents were suggested by adding a term as like 5B or 14B into the Kaizu equation, and it could improve the accuracy of the prediction model.

A Survey Tool for the Measurements of the Rock Parting Surfaces (암반의 불연속면 배열을 측량하는 원격 영상측량기)

  • 황상기;임유진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.697-704
    • /
    • 2000
  • This study presents methodology and tools for remote measurement of the orientation of the rock parting surfaces. Two close circuit video camera capture the pictures of a rock excavation surface while a laser beam scans the surface. Positions of the laser beams in the two digital images are recognized by image processing. Using the stereoscopic concept, three dimensional coordinations of the rock surface and the orientation of the rock parting planes are calculated. Point, cross and line type laser beams are tested for better image processing results and measurement accuracy of the coordinates. According to a simple accuracy test, cross beam show better results than the point beam. However, line beam show more promising results for the measurement of the rock parting surfaces.

  • PDF

Precision enhancement for a CCD/LSB type shape measuring system (CCD/LSB 방식의 형상측정시스템의 정밀도 향상 방법)

  • 유주상;정규원
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.137-142
    • /
    • 2001
  • Since recent production system becomes that of the small quantity, large volume with high quality production, accurate and high speed inspection system is required. In such situation, noncontact 3D measurement system which utilized CCD cameras is useful technique in terms of system cost, speed of data acquisition, measuring accuracy and application. However, it has low accuracy compared with contact 3D measurement system because of the camera distortion, non uniformity of laser distribution and so on. For those reasons, in this paper precision enhancement method is studied considering radial camera distortion, and laser distribution. A distortion correction method is applied even to the standard lens. The laser slit beam trajectory is determined by 3 method: based of the Gaussian function signal approximation, the median method, the center of gravity method and the peak point of the Gaussian function method.

  • PDF