• 제목/요약/키워드: Laser Therapy

검색결과 560건 처리시간 0.028초

Therapeutic Effect of Low-Energy Nitrogen Plasma Pulses on Tinea Pedis

  • Kim, Heesu;Kim, Hyun-Jo;Cho, Sung Bin
    • Medical Lasers
    • /
    • 제8권1호
    • /
    • pp.28-31
    • /
    • 2019
  • Superficial fungal infections with dermatophytes, nondermatophyte molds, or yeasts are treated primarily with topical and/or systemic antifungal agents. Additional or alternative treatment modalities, particularly energy-delivering modalities, however, are used widely to induce fungicidal effects via selective photothermal reactions. In addition to light- or laser-based devices, plasma therapy also has antifungal properties. This report describes a Korean male patient with mycologically confirmed tinea pedis that was treated effectively with two sessions of nitrogen plasma treatment at one-week intervals using a plasma delivering system. Nitrogen plasma was prepared by loading a 0.28-ml inert nitrogen gas/pulse that was activated by a microwave generator. The other treatment settings were a nozzle diameter of 5 mm, pulse energy of 0.75 J, pulse duration of 7 msec, and two passes. One week after the first session of nitrogen plasma treatment, the patient exhibited marked reductions in scale and inflammation. One month after the final treatment, no clinical features of recurrence were found, and successive potassium hydroxide testing revealed negative results.

레이저 유도형광분광기에서 고정밀 전하장치를 이용한 304 스테인레스 스틸의 코팅과 특성 (The Characterization and Coatings on 304 Stainless Steel by Laser Induced Fluorescence Spectroscopy using the High Resolution Charge Coupled Device)

  • 김기준;이주엽;성완모
    • 한국응용과학기술학회지
    • /
    • 제33권2호
    • /
    • pp.385-390
    • /
    • 2016
  • 연구에서 나노 알루미나와 마그네지아의 첨가에 의한 304 스테인레스 스틸에 $170^{\circ}C$ 2시간 열 경화시켰다. 레이저유도 분광학에 의한 코팅된 시료를 전하결합 장치와 SEM을 활용한 장치를 설계하여 시험 측정하였다. 이 결과 나노 알루미나와 마그네지아가 함유된 세라믹 코팅이 나노 무기화합물이 함유되지 않은 시료보다 부착성, 내스크래치성이 우수하였으며, 또한 산용액속에서 시료의 질량감소의 변화가 매우 작았다. 그리하여 본 연구는 304 스테인레스 스틸의 내부식성을 개선하기 위해 시료가 코팅되었으며, 분석공정이 설계되어 고분해능 CCD와 함께 분석되었다. 요즈음, 스테인레스 스틸의 코팅은 산업에 특이응용이 발전됨에 따라 위생학, 우주항공, 기기장치, 관측 등의 분야 등에 산업적 요구가 증가되고 있다.

Changes in Breast-tumor Blood Flow in Response to Hypercapnia during Chemotherapy with Laser Speckle Flowmetry

  • Kim, Hoonsup;Lee, Youngjoo;Lee, Songhyun;Kim, Jae Gwan
    • Current Optics and Photonics
    • /
    • 제3권6호
    • /
    • pp.555-565
    • /
    • 2019
  • Development of a biomarker for predicting tumor-treatment efficacy is a matter of great concern, to reduce time, medical expense, and effort in oncology therapy. In a preclinical study, we hypothesized that the blood-flow parameter based on laser speckle flowmetry (LSF) could be a potential indicator to estimate the efficacy of breast-cancer treatment. To verify this hypothesis, a 13762-MAT-B-III rat breast tumor was grown in a dorsal skinfold window chamber applied to a nude mouse, and the change in blood flow rate (BFR) - or the speckle flow index (SFI) is used together as the same meaning in this manuscript - was longitudinally monitored during tumor growth and metronomic cyclophosphamide treatment. Based on the daily LSF angiogram, several BFR parameters (baseline SFI, normalized SFI, and △rBFR) were compared to tumor size in the normal, treated, and untreated tumor groups. Despite the incomplete tumor treatment, we found that the daily changes in all BFR parameters tended to have partially positive correlation with tumor size. Moreover, we observed that the changes in baseline SFI and normalized SFI responded one day earlier than the tumor shrinkage during chemotherapy. However, daily variations in the hypercapnia-induced △rBFR lagged tumor shrinkage by one day. This study would contribute not only to evaluating tumor vascular response to treatment, but also to monitoring blood-flow-mediated diseases (in brain, skin, and retina) by using LSF in preclinical settings.

The effects of physical decontamination methods on zirconia implant surfaces: a systematic review

  • Tan, Nathan Chiang Ping;Khan, Ahsen;Antunes, Elsa;Miller, Catherine M;Sharma, Dileep
    • Journal of Periodontal and Implant Science
    • /
    • 제51권5호
    • /
    • pp.298-315
    • /
    • 2021
  • Purpose: Peri-implantitis therapy and implant maintenance are fundamental practices to enhance the longevity of zirconia implants. However, the use of physical decontamination methods, including hand instruments, polishing devices, ultrasonic scalers, and laser systems, might damage the implant surfaces. The aim of this systematic review was to evaluate the effects of physical decontamination methods on zirconia implant surfaces. Methods: A systematic search was conducted using 5 electronic databases: Ovid MEDLINE, PubMed, Scopus, Web of Science, and Cochrane. Hand searching of the OpenGrey database, reference lists, and 6 selected dental journals was also performed to identify relevant studies satisfying the eligibility criteria. Results: Overall, 1049 unique studies were identified, of which 11 studies were deemed suitable for final review. Air-abrasive devices with glycine powder, prophylaxis cups, and ultrasonic scalers with non-metal tips were found to cause minimal to no damage to implantgrade zirconia surfaces. However, hand instruments and ultrasonic scalers with metal tips have the potential to cause major damage to zirconia surfaces. In terms of laser systems, diode lasers appear to be the most promising, as no surface alterations were reported following their use. Conclusion: Air-abrasive devices and prophylaxis cups are safe for zirconia implant decontamination due to preservation of the implant surface integrity. In contrast, hand instruments and ultrasonic scalers with metal tips should be used with caution. Recommendations for the use of laser systems could not be fully established due to significant heterogeneity among included studies, but diode lasers may be the best-suited system. Further research-specifically, randomised controlled trials-would further confirm the effects of physical decontamination methods in a clinical setting.

전산화단층 모의치료장치의 정도관리 항목 제안 (Proposal of CT Simulator Quality Assurance Items)

  • 김연래;윤영우;정재용;이정우;정진범
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.367-373
    • /
    • 2021
  • A quality assurance of computed tomography(CT) have done seven items that were water attenuation coefficient, noise, homogeneity, spatial resolution, contrast resolution, slice thickness, artifact using by standard phantom. But there is no quality assurance items and methods for CT simulator at domestic institutions yet. Therefore the study aimed to access the CT dose index(CTDI), table tilting, image distortion, laser accuracy, table movement accuracy and CT seven items for CT simulator quality assurance. The CTDI at the center of the head phantom was 0.81 for 80 kVp, 1.55 for 100 kVp, 2.50 for 120 mm, 0.22 for 80 kVp at the center of the body phantom, 0.469 for 100 kVp, and 0.81 for 120 kVp. The table tilting was within the tolerance range of ±1.0° or less. Image distortion had 1 mm distortion in the left and right images based on the center, and the laser accuracy was measured within ±2 mm tolerance. The purpose of this study is to improve the quality assurance items suitable for the current situation in Korea in order to protect the normal tissues during the radiation treatment process and manage the CT simulator that is implemented to find the location of the tumor more clearly. In order to improve the accuracy of the CT simulator when looking at the results, the error range of each item should be small. It is hoped that the quality assurance items of the CT simulator will be improved by suggesting the quality assurance direction of the CT simulator in this study, and the results of radiation therapy will also improve.

일일 정도관리를 위한 Daily Check Device의 제작 및 효율성 평가 (Manufacture of Daily Check Device and Efficiency Evaluation for Daily Q.A)

  • 김찬용;제영완;박흥득;이제희
    • 대한방사선치료학회지
    • /
    • 제17권2호
    • /
    • pp.105-111
    • /
    • 2005
  • 목 적 : 방사선 치료의 성적 향상과 안정성, 정확성을 위해 시행되고 있는 정도관리는 치료과정의 오류를 사전 점검하기 위해 무엇보다 우선되어야 할 항목이다. 최근 방사선 치료기술이 3차원적으로 다양화되면서 정도관리의 중요성이 증대되고 있으며, 일일 정도관리 시 업무능률 향상을 위하며 체계적이고 신속한 방법이 요구되었다. 이에 본원에서는 일일 점검항목을 동시에 확인할 수 있는 Device를 자체 제작하여 그 효율성을 평가해 보고자 한다. 대상 및 방법 : 출력선량, laser alignment, field size, SSD indicator 점검을 한 번의 set up으로 시행할 수 있도록 device의 전면중앙 아크릴판 (가로 $30{\times}$ 세로 $30cm^2$)의 2 cm 깊이에 반도체 검출기를 삽입하였다. 상단에 $10{\times}10,\;20{\times}20cm^2$의 정방형 표시를 하여 field size를 확인할 수 있게 하였으며, 좌우 측면에 수직교차선이 표시되어있는 $30{\times}20cm^2$의 아크릴판을 부착하였다. 본 device를 4개월(2005. $2{\sim}5$월) 동안 본원에 설치되어 있는 4대의 선형가속기 일일 정도 관리에 사용하여 오차 점검의 편리성과 업무의 효율성에 관해 적용해 보았다. 결 과 : 측정과정이 간편하고 소요시간이 5분 정도로 기존($10{\sim}15$분)보다 단축되어 일일점검의 효율성이 향상되었고, 출력선량측정은 각 Energy별로 ${\pm}2%$이내였으며, laser, field size, SSD indicator는 ${\pm}1mm$이내의 범위에서 측정되었다. 결 론 : 일일 점검의 소요시간 단축으로 인하며 업무능률이 향상되었고 일일 정도관리 기록을 바탕으로 월간, 연간 정도 관리 기초 자료로써의 활용이 가능하였다. 또한 제작된 Daliy Check Device는 상품화된 고가의 측정 장비를 대체함으로써 비용절감 효과를 얻을 수 있었으며, 사용자의 편의 개선을 위한 장치 재질의 견고성 및 가벼운 소재의 개발이 필요할 것으로 사료된다.

  • PDF

폐암에서 광역동치료술의 효과 (Effect of Photodynamic Therapy in Lung Cancer)

  • 윤성호;한경택;김경남;이승일
    • Tuberculosis and Respiratory Diseases
    • /
    • 제57권4호
    • /
    • pp.358-363
    • /
    • 2004
  • 연구배경 : 폐암에서 광역동치료는 미세침습성 비소세포폐암 및 기관지폐쇄를 일으키는 악성종양에 대한 기관지내 치료를 미국식품의약국(FDA)에서 승인한 상태이다. 국내에서는 폐암세포주에 대한 보고 외에 폐암에 대한 광역동치료 연구가 많지 않아 임상 성적에 대한 보고가 없어 이에 저자들은 폐암에서 시행된 광역동치료에 대한 결과를 문헌고찰과 함께 보고하고자 한다. 방 법 : 2002년 8월부터 2003년 5월까지 조선대학교 병원에서 기관지 내시경을 통해 조직학적으로 진단된 폐암환자 중 10명을 대상으로 하여 광역동치료 48시간 전에 광과민제(Photogem$^{(R)}$, Lomonosov institute of Fine Chemical, Russia)를 2.0mg/Kg을 정맥 주사한 후 48시간, 72시간에 Diode LASER system(Biolitec Inc., Germany, wavelength; 633nm)을 사용하여 광역 동치료를 시행하였다. 결 과 : 10명 중 9예에서 부분관해와 함께 기관지 개통을 보였으며, 1예에서는 변화를 보이지 않았다. 결 론 : 저자들은 광역동치료를 통해 기관지폐쇄로 인한 호흡곤란 및 기관지 폐쇄와 관련된 폐렴이 개선됨을 확인 하였으며, 합병증이 적어 안전한 기관지내 치료법으로 생각된다. 앞으로 광역동 치료에 대한 장기적인 결과 및 적절한 치료 적응증 및 조기 폐암에서 치료효과 등에 대한 연구가 필요할 것으로 생각된다.

Mechanical Check용 Spherical Device의 제작 및 특성 평가 (Practicability Assessment of Spherical Type Mechanical Check Device (SMCD))

  • 이병구;김건오;권영호
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.55-62
    • /
    • 2007
  • 목 적: PACS의 도입에 발맞추어 시작된 디지털 의료영상은 현재 방사선 진단 및 치료 영역에서 일반화되었으며 특히 진단 영역에서는 눈부신 발전을 거듭하고 있다. 치료영역에서의 디지털 영상 구현은 상대적으로 느린 성장과정을 거쳐 오늘에 이르고 있다. 본 논문은 이러한 아날로그에서 디지털로 변화하는 흐름을 인식하여 정도관리(Quality Assurance) 업무 중 기계적 점검(Mechanical check) 부분을 디지털 영상 기반 업무로 대체하여 수행하고, 기존의 육면체 또는 사각형틀의 개념을 탈피한 구형(球形)의 Spherical type mechanical check device (SMCD)를 고안하여 그 실용성을 실험하였다. 대상 및 방법: 선원에서 영상 detecter 간의 거리가 항상 일정하고, SMCD의 중심까지 거리가 일정하다면 어느 방향에서 방사선으로 SMCD를 조사하더라도 그 크기는 항상 일정하게 영상으로 표현 될 것이다. 이를 위해 Polyester P.E 재질의 정확한 반구(半球) 2개를 자체 제작하여 그것을 합쳤을 때 정원(正圓)의 구(球)가 되도록 하였다. 결 과: SMCD를 이용하여 방사선조사면과 광조사면의 일치도, 방사선조사면 크기의 정확도($5{\times}5$, $10{\times}10$, $15{\times}15cm^2$), Collimator field 크기의 정확도($5{\times}5$, $10{\times}10$, $15{\times}15cm^2$), Gantry rotation isocenter check, Collimator rotation isocenter check, Room laser accuracy check, Collimator rotation angle check와 Couch rotation angle check 등 기존의 기계적 점검을 디지털 영상을 이용하여 실행할 수 있었다. 결 론: 기존의 Flat 또는 정육면체 형태의 기계적 점검 장치로는 쉽게 하기 힘든 non-coplanar field에 적용되는 Gantry와 Couch가 동시에 rotation 되었을 때 그 isocenter의 일치도를 실시간으로 확인할 수 있었다.

  • PDF

혈류량과 통증역치에 대한 경혈과 전기자극치료의 융합연구 (Convergence of Acupoint and Electrical Stimulation Therapy for Blood Flow and Pain Threshold)

  • 이동현;김범룡;허윤정;김동훈;심수영;임종은
    • 한국융합학회논문지
    • /
    • 제10권6호
    • /
    • pp.79-87
    • /
    • 2019
  • 본 연구는 건강한 성인남녀를 대상으로 경혈지점에 은침전기자극과 침형 경피신경전기자극을 적용하여 혈류량과 통증 역치에 미치는 효과를 알아보고자 하였다. 성인남녀 32명을 대상으로 SSP group (n=18), A-TENS group (n=14)으로 무작위 배정하여 적용하였다. 혈류량을 측정하기 위해 레이저 도플러 영상을 사용하였고, 통증 역치를 측정하기 위해 압통측정기를 사용하였다. 집단 내 혈류량의 변화는 두 그룹 사이에서 유의한 차이가 있었고(p<0.05), 압통 역치의 변화는 SSP group에서만 유의한 차이가 있었다(p<0.05). 중재 후 집단 간 혈류량과 압통 역치의 변화에서는 SSP group과 TENS group 사이에서 유의한 차이가 있었다(p<0.05). 결과적으로 경혈지점에 SSP와 A-TENS을 적용한 결과 혈류량과 압통 역치의 변화가 있었으며, 특히 SSP을 경혈지점에 적용할 때 더욱 큰 변화를 볼 수 있었다. 이러한 결과를 바탕으로 경혈과 전기자극치료의 융합이 다양한 환자를 위한 방법의 하나로 유용하게 적용할 수 있으며, 지속적인 융합중재개발이 필요하다.

Streptococcus mutans 바이오필름에 대한 에리스로신 매개 광역동 치료 시 potassium iodide의 효과 (Effect of Potassium Iodide on Erythrosine-Mediated Photodynamic Therapy on Streptococcus Mutans Biofilms)

  • 김용순;박호원;이주현;김해니;이시영
    • 대한소아치과학회지
    • /
    • 제49권3호
    • /
    • pp.321-328
    • /
    • 2022
  • 이 연구는 Streptococcus mutans 바이오필름에 대한 에리스로신 매개 광역동 치료에서 potassium iodide (KI)의 효과를 평가하는 In vitro 실험이다. S. mutans ATCC 25175를 배양하여 hydroxyapatite disk에 바이오필름을 형성하였다. 광감각제인 에리스로신을 20 μM, KI를 각각 10, 50, 100 mM로 희석하여 적용한 뒤 광역동 치료를 시행하였다. 생존한 세균의 수는 colony forming units (CFU)/mL로 산정하였으며 Bonferroni 사후 분석을 통해 그룹 간 차이의 유의성을 확인하였다. Confocal laser scanning microscopy (CLSM)을 이용하여 세포 생존율을 시각적으로 평가하였다. 실험 결과 KI를 적용한 후 광역동 치료를 시행한 실험군에서 KI의 농도의 관계 없이 현저한 CFU의 감소가 관찰되었다(p < 0.05). 또한 10 mM KI에 비해 100 mM KI를 적용한 실험군에서 유의한 CFU의 감소가 관찰되었다(p < 0.05). CLSM 관찰 시에도 동일한 결과를 확인하였다. KI는 모든 농도에서 S. mutans 바이오필름에 대한 에리스로신 매개 광역동 치료의 효과를 유의하게 향상시켰다. 이는 바이오필름 상태의 균주에 대한 광역동 치료의 낮은 감수성을 보완할 수 있지만, 추가적인 연구를 통한 최적의 임상 프로토콜 확립이 필요하다.