• Title/Summary/Keyword: Laser Speckle

Search Result 124, Processing Time 0.018 seconds

Laser Speckle Imaging Using Laser Speckle Endoscope (레이저 스펙클 내시경을 이용한 미세혈관 영상화 기법)

  • Jin, Ho-Young;Shin, Hyun-Chool
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.6
    • /
    • pp.91-96
    • /
    • 2010
  • A laser speckle is a random pattern that has a granular appearance produced by reflected light when a coherent laser illuminates an irregular course surface. Laser speckle system has many advantages. It can detect some animals functional parts. Moreover, it relatively consists of simple and in-expensive system. It is very important that detecting micro-vessels through image processed image. Current study is to improve image quality through variable image processing method. But this paper made laser speckle endoscope for miniaturization and commercialization laser speckle system. We had endoscope test through goldfish's tail. We will compare the processed speckle image and halogen image.

Enhancement of Speckle Contrast in vivo by Combining Linearly Polarized Laser Light and an Analyzer

  • Qureshi, Muhammad Mohsin;Mac, Khuong Duy;Kim, Andrew Hyunjin;Kim, Young Ro;Chung, Euiheon
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.351-361
    • /
    • 2021
  • Speckle imaging is capable of dynamic data acquisition at high spatiotemporal resolution, and has played a vital role in the functional study of biological specimens. The presence of various optical scatterers within the tissue causes alteration of speckle contrast. Thus structures like blood vessels can be delineated and quantified. Although laser speckle imaging is frequently used, an optimization process to ensure the maximum speckle contrast has not been available. In this respect, we here report an experimental procedure to optimize speckle contrast via applying different combinations of varying polarization of the illuminating laser light and multiple analyzer angles. Specifically, samples were illuminated by the p-polarization, 45°-polarization, and s-polarization of the incident laser, and speckle images were recorded without and with the analyzer rotated from 0° to 180° (Δ = 30°). Following the baseline imaging of a solid diffuser and a fixed brain sample, laser speckle contrast imaging (LSCI) was successfully performed to visualize in vivo mouse-brain blood flow. For oblique laser illumination, the maximum contrast achieved with p-polarized and s-polarized light was perpendicular to the analyzer's axis. This study demonstrates the optimization process for maximizing the speckle contrast, which can improve blood-flow estimation in vivo.

A study on speckle size and measurable limitations in laser speckle interferometry method (레이저 스페클간섭법에 있어서 스페클크기와 측정 한계에 관한 연구)

  • 윤성운
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 1996
  • The high coherence of laser beam has made it possible to observe interference effects even in the light scattered from rough surfaces. That's why, when object with a scattering surface is illuminated with laser light, we do see a speckled appearance due to random interference. This sort of unique property of laser speckle has bruht into existence the new noncontaciting techniques such as speckle metrology method of measuring deformation, displacement, and vibration etc of objects with high optical sensitivity. The measurable range of speckle metrology especially used to measure in -plane information, however, is limited by some factors, the so-called strain, rotation tilt of surface and out of displacement perpendicular to the plane of analysis This restrictions severly limits the measurable range of speckle metrology by causing the decorrelation of speckle patterns. It is the purpose of this paper to give a survey on the measurable limitation of speckle photography method that is one of speckle metrology. Namely we will discuss the mutual relationships and problems of each limitations adding the restriction on the largest and smallest displacement measurable with speckle methods.

  • PDF

Laser Speckle Imaging Using Adaptive Windowing Method (적응 윈도우 기법을 사용한 레이저 스펙클 영상의 처리)

  • Jin, Ho-Young;Shin, Hyun-Chool
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.1
    • /
    • pp.97-102
    • /
    • 2010
  • A laser speckle is a random pattern that has a granular appearance produced by reflected light when a coherent laser illuminates an irregular course surface. Most important property of laser speckle is detecting micro-vascular. Speckle image needs image processing to detect micro-vascular. This paper proposes a new image processing method for laser speckle, adaptive window method that adaptively processes laser speckle images in the spatial. Conventional fixed window based LASCA has shortcoming in that it uses the same window size regardless of target areas. Inherently laser speckle contains undesired noise. Thus a large window is helpful for removing the noise but it results in low resolution of image. Otherwise a small window may detect micro vascular but it has limits in noise removal. To overcome this trade-off, we newly introduce the concept of adaptive window method to conventional laser speckle image analysis. We have compared conventional LASCA and its variants with the proposed method in terms of image quality and processing complexity.

EXPERIMENTAL STUDY OF THE CENTER OF RESISTANCE OF A MAXILLARY CANINE USING LASER SPECKLE INTERFEROMETRY AND HOLOGRAPHIC INTERFEROMETRY (상악 견치의 저항 중심에 관한 Laser speckle interferometry와 holographic interferometry볼 이용한 실험적 연구)

  • Lee, Soo Ryong
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.289-308
    • /
    • 1988
  • The center of resistance is a important determining factor of tooth movement pattern. Laser speckle interferometry, recently developed for noninvasive measurement of small displacements (microns), was used to detect the center of resistance of a maxillary canine which has normal tooth axis and distal curved root in dry human skull. Laser holographic interferometry was used to verify the results of laser speckle interferometry The following result were obtained; 1. In measurement of the degree of rotation, center of resistance was localized when the traction line passed 4.4/18.0 level from alveola crest to root apex. 2. In measurement of the degree of tipping, center of resistance was localized when the traction line passed 4.6/18.0 level from alveola crest to root apex. 3. In holographic determination, the center of resistance was observed when the traction line passed between 3mm to 6mm level from alveola crest to root apex, therefore the results using laser speckle interferometry was coincided with holographic results.

  • PDF

Design and Fabrication of Optical Element for Speckle Reduction in Laser Projector (레이저 프로젝터의 스페클 저감을 위한 광학 소자 설계 및 제작)

  • Lee, Jae-Yong;Kim, Young-Joo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.10 no.2
    • /
    • pp.55-60
    • /
    • 2014
  • Laser projector has many advantages of high brightness, high resolution and small size, but the huge drawback of image degradation called speckle which generated by coherence of laser and roughness of surface interrupts their general use. There are many methods to reduce speckle pattern, but they need effective optical systems to realize display to the far field with huge volume. We designed speckle reduction element by using microlens with controlled curvature to reduce spatial coherence. Vibration element was also applied to reduce temporal coherence which considered response time of eye. Designed element was fabricated by simple reflow method and imprinting method. From the results, the fabricated element performed 48.33% of speckle reduction efficiency and 41.29% of optical efficiency with a single doublet lens.

Development of Laser Speckle Flowgraphy System for Monitoring Blood Flow in Skin Tissue (레이저 산란 현상을 이용한 피부혈류 화상화 시스템의 개발)

  • Lee, M.C.;Fujii, H.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.392-396
    • /
    • 2007
  • In this paper, we develop a new system to visualize the blood flow map in skin tissue, using the technique of Laser Speckle Flowgraphy (LSFG). The measuring unit consists of the laser diode, imaging system, line sensor, scanning mirror, and one-board microcomputer. The speckle signal is analyzed and sent to a PC, where the blood flow in a tissue area of $14mm{\times}26 mm$ is evaluated and displayed in a 2-D color map. It is demonstrated that the new LSFG instrument is useful to evaluate the degree of allergic reaction in patch test.

Measurement of Deformation field in CT specimen using Laser speckle (레이저 스페클을 이용한 CT 시험편의 변형장 측정)

  • Jean, Moon-Chang;Kang, Ki-Ju
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.192-197
    • /
    • 2001
  • To obtain $A_2$ experimentally in the $J-A_2$ theory, deformation field on the lateral surface of a CT specimen was to be determined using Laser speckle method. The crack growth was measured using direct current potential drop method and most procedure of experimental and data reduction was performed according to ASTM Standard E1737-96. Laser speckle images during crack propagation were monitored by two CCD cameras to cancel the effect of rotation and translation of the specimen. An algorithm to pursue displacement of a point from each image was developed and successfully used to measure $A_2$ continuously as the crack tip was propagated. The effects of specimen thickness on J-R curve and $A_2$ were explored.

  • PDF