• Title/Summary/Keyword: Laser Discharge

Search Result 244, Processing Time 0.026 seconds

Development of the Discharge Heated Copper Vapor Laser (방전가열형 구리증기레이저의 개발)

  • 임창환;차병헌;성낙진;이종민
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.28-32
    • /
    • 1990
  • We have constructed and operated a discharge heated copper vapor laser which generated green (510.6 nm) and yellow (578.2 nm) light. The plasma tube was made of high purity (99.8%) alumina tube which has an inner diameter 25 mm and a length 106 cm. The electrodes, made of molybdenum sheet, were separated 108 cm apart. The laser gave an average power of 10 W at repetition rate of 5 kHz, charging voltage of 10 kV, Ne buffer gas pressure of 40 mbar, and the laser tube temperature of $1500^{\circ}C$..

  • PDF

Theoreitica1 analysis of plasma processes in discharge excited KrF laser (방전어기 KrF 레이저의 프라즈마 프로세서 해석)

  • Choi, Boo-Yeon;Lee, Choo-His
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.505-508
    • /
    • 1989
  • A computer simulation code of UV preionized discharge KrF laser is developed, including time dependent circuit equations, boltzmann equations, and plasma kinetic equations for various atomic and molecular species. Rate constants for electron collision processes are calculated with a boltzmann equations as a function of E/N. In this study, we studied mainly the $KrF^*$ formation process, relaxation process, and the 248nm absorption process as a function of charging voltage.

  • PDF

Improving the efficiency in discharge pumped excimer laser (방전여기 엑시머 레이저의 고효율화 방안)

  • Lee Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.368-370
    • /
    • 2006
  • 자외선영역에서 발진하는 엑시머 레이저 장치의 가스 장수명화에 의한 고효율화 방안을 제안하였다. 가스수명에 대하여 불소$(F_2)$의 감소와 불순물 발생에 의한 출력 변화의 이론적 해석 결과를 보고한다.

  • PDF

Analysis of Xe Plasma by LAS (레이저 흡수법을 이용한 제논 플라즈마 분석)

  • Yang, Jong-Kyung;Her, In-Sung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.220-222
    • /
    • 2005
  • We can classify two cases in a way to observe an atom of gas state or a molecule using the laser. First case is way to use dispersion phenomenon like Rayleigh scattering, Thomson scattering, Mie scattering, Raman Scattering. And Second case is a way to use change phenomenon like a LAS (Laser Absorption Spectroscopy), LIF (Laser Induced Fluorescent). In this paper, we have measured the meta-stable density and the distribution by using a LAS method in Xe discharge lamp. The laser absorption spectroscopy (LAS) is useful to investigate the behavior of such species. The xenon atoms in the $1S_4$ and $1S_5$ generate excited $Xe^*$(147nm) and $Xe_{2}^*$(173nm) dimers in Xe plasma. It is found that the intensity of VUV 147nm emission is proportional to that of the IR 828nm emission, and the VUV 173nm emission is roughly proportional to that of the IR 823nm emission. The laser is used CW laser that consist of AlGaAs semiconductor and energy level is used 823.16nm wavelength. We measured signal of monochrometer from the lamp center while will change a discharge electric current by 6mA in 3mA and calculated meta-stable state density of a xenon atom through a measured value.

  • PDF

A Study on the Pulsed $CO_2$ Laser by the Switching Control of Leakage Transformer Primary (누설변압기 1차측의 스위칭 제어에 의한 펄스형 $CO_2$레이저에 관한 연구)

  • Chung, Hyeon-Ju;Lee, Dong-Hoon;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.9
    • /
    • pp.541-545
    • /
    • 2000
  • We propose a pulsed $CO_2$laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantages of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5 Hz to 60 to Hz control laser output. In this laser a low voltage open loop control for high voltage pulse discharge circuit is employed to aviod the Hv sampling or switching and high voltage leakage transformer is used to convert low voltage pulse rectified from AC to high voltage one. A ZCS(Zero Crossing Switch) circuit and a PIC(programble one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leadkage inductance. The maximum laser output was about 23 W at pulse repetition rate of 60Hz total gas mixture of $CO_2$ : $N_2$ : He=1: 9: 15 and total pressure of 18 Torr

  • PDF

The optical analysis of discharge lamp by Laser

  • Yang, Jong-Kyung;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.570-571
    • /
    • 2005
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1\rightarrow6^3P_2$) were larger than 404.8nm ($6^3S_1\rightarrow6^3P_1$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the L1F signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

  • PDF

Comparative Study on the Efficiency of the Gas Discharge Lasers - Limiting Efficiency of Metal Vapor Lasers - (기체방전 레이저의 효율에 관한 연구 -금속증기레이저의 한계효율-)

  • 이재경
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.47-56
    • /
    • 1993
  • Practical efficiencies of pulsed gas discharge lasers utilizing vaporized Au, Ba, Cu, Fe, Mn, Pb, TI atoms are numerically optimized for a discharge pulse of 30 ns rise time at 5 kHz pulse repetition rate. Calculated optimum operating temperatures are close to the values at which the vapor pressure of each atom is about 1 Torr and are in good agreement with experimental values reported elasewhere. The optimum charging voltage was about 4 kV for all atomic vapor lasers except the TI laser. The calculated maximum efficiencies that have been discussed for possible limiting efficiencies for each laser were considerably higher than the reported experimental values. Especially, they were as high as 6.8% for Mn laser and 15% for Ba laser that were comparable to the 8.5% of copper vapor laser, from which considerably higher efficiencies can be expected for these two lasers experimentally. But, the present calculation shows a very low efficiency of 0.058% and requires an exceptional operating condition for the TI laser.

  • PDF

Development of multi-repetitive Pulse Compression System for excimer laser excitation (엑사이머 레이저 여기용 고반복 펄스압축 시스템 개발에 관한 연구)

  • 전상영
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.36-38
    • /
    • 1989
  • We have developed Magnetic Pulse Compression System to realize repetitive excimer laser excitation. The principle of this system is to use the large change in permiability owing to the nolinear characteristics of ferro-magnetic material (Metglas2605s-2 metal ribon). Prior to the laser operation, the MPC system was tested with a dummy load (5$\Omega$) and laser head. Laser head has a discharge volume of 1.0 (w) x 2.0 (h) x 20.0(1) cm. This MPC system compressed a 6.2us (FWHM), 80 A pulse into a 0.4us(FWHM), 1.3kA pulse.

  • PDF