• 제목/요약/키워드: Large-area Compton camera

검색결과 5건 처리시간 0.023초

Design and performance prediction of large-area hybrid gamma imaging system (LAHGIS) for localization of low-level radioactive material

  • Lee, Hyun Su;Kim, Jae Hyeon;Lee, Junyoung;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1259-1265
    • /
    • 2021
  • In the present study, a large-area hybrid gamma imaging system was designed by adopting coded aperture imaging on the basis of a large-area Compton camera to achieve high imaging performance throughout a broad energy range (100-2000 keV). The system consisting of a tungsten coded aperture mask and monolithic NaI(Tl) scintillation detectors was designed through a series of Geant4 Monte Carlo radiation transport simulations, in consideration of both imaging sensitivity and imaging resolution. Then, the performance of the system was predicted by Geant4 Monte Carlo simulations for point sources under various conditions. Our simulation results show that the system provides very high imaging sensitivity (i.e., low values for minimum detectable activity, MDA), thus allowing for imaging of low-activity sources at distances impossible with coded aperture imaging or Compton imaging alone. In addition, the imaging resolution of the system was found to be high (i.e., around 6°) over the broad energy range of 59.5-1330 keV.

Development of hybrid shielding system for large-area Compton camera: A Monte Carlo study

  • Kim, Jae Hyeon;Lee, Junyoung;Kim, Young-su;Lee, Hyun Su;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2361-2369
    • /
    • 2020
  • Compton cameras using large scintillators have been developed for high imaging sensitivity. These scintillator-based Compton cameras, however, mainly due to relatively low energy resolution, suffer from undesired background-radiation signals, especially when radioactive materials' activity is very low or their location is far from the Compton camera. To alleviate this problem for a large-size Compton camera, in the present study, a hybrid-type shielding system was designed that combines an active shield with a veto detector and a passive shield that surrounds the active shield. Then, the performance of the hybrid shielding system was predicted, by Monte Carlo radiation transport simulation using Geant4, in terms of minimum detectable activity (MDA), signal-to-noise ratio (SNR), and image resolution. Our simulation results show that, for the most cases, the hybrid shielding system significantly improves the performance of the large-size Compton camera. For the cases investigated in the present study, the use of the shielding system decreased the MDA by about 1.4, 1.6, and 1.3 times, increased the SNR by 1.2-1.9, 1.1-1.7, and 1.3-2.1 times, and improved the image resolution (i.e., reduced the FWHM) by 7-8, 1-6, and 3-5% for 137Cs, 60Co, and 131I point source located at 1-5 m from the imaging system, respectively.

Development of simultaneous multi-channel data acquisition system for large-area Compton camera (LACC)

  • Junyoung Lee;Youngmo Ku;Sehoon Choi;Goeun Lee ;Taehyeon Eom ;Hyun Su Lee ;Jae Hyeon Kim ;Chan Hyeong Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3822-3830
    • /
    • 2023
  • The large-area Compton camera (LACC), featuring significantly high detection sensitivity, was developed for high-speed localization of gamma-ray sources. Due to the high gamma-ray interaction event rate induced by the high sensitivity, however, the multiplexer-based data acquisition system (DAQ) rapidly saturated, leading to deteriorated energy and imaging resolution at event rates higher than 4.7 × 103 s-1. In the present study, a new simultaneous multi-channel DAQ was developed to improve the energy and imaging resolution of the LACC even under high event rate conditions (104-106 s-1). The performance of the DAQ was evaluated with several point sources under different event rate conditions. The results indicated that the new DAQ offers significantly better performance than the existing DAQ over the entire energy and event rate ranges. Especially, the new DAQ showed high energy resolution under very high event rate conditions, i.e., 6.9% and 8.6% (for 662 keV) at 1.3 × 105 and 1.2 × 106 s-1, respectively. Furthermore, the new DAQ successfully acquired Compton images under those event rates, i.e., imaging resolutions of 13.8° and 19.3° at 8.7 × 104 and 106 s-1, which correspond to 1.8 and 73 μSv/hr or about 18 and 730 times the background level, respectively.

파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측 (Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring)

  • 김영수;박진형;조화연;김재현;권흥록;서희;박세환;김찬형
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.1-9
    • /
    • 2015
  • 콤프턴 카메라는 검출 신호의 동시성 판단을 기반으로 한 전자적 집속방식을 이용하기 때문에, 기존의 물리적 집속기를 이용하는 감마선 영상 장비의 가시영역이 좁고 투과력이 높은 고에너지 감마선에 적용하기 어렵다는 한계를 극복할 수 있다. 특히 대면적의 콤프턴 카메라는 절대 검출 효율이 높아 영상 장비의 운반이 요구되지 않는 대규모 공정 시설내 핵물질의 모니터링용으로 매우 적합하다. 본 연구팀은 한국원자력연구원에서 개발 중인 파이로 시험 공정 시설에서의 안전조치 수립을 위해 대면적 콤프턴 카메라를 적용하고자 한다. 대면적 콤프턴 카메라를 구성하는 대면적의 검출기는 그 형태나 구성 방식에 따라 에너지 분해능이나 위치 분해능이 달라질 수 있다. 이는 콤프턴 영상의 질에 직접적으로 영향을 미치므로, 본 연구에서는 전산모사를 통해 그 영향을 예측하여 대면적 검출기의 설계 방향을 결정하였다. 또한 한국원자력연구원으로부터 파이로 시험 공정 시설의 정보를 전달받아 전산모사를 수행하였고, 여러 계측 환경에 대해 대면적 콤프턴 카메라의 성능을 예측하여 보았다. 그 결과 대면적 검출기는 에너지 분해능 측면에서의 손실을 최소화 할 수 있도록 구성하여야 한다는 결론을 얻었으며, 에너지 분해능 10%, 위치 분해능 7 mm 정도 성능의 검출기를 이용하여 콤프턴 카메라를 구성할 경우 1 m 거리에 위치한 감손우라늄 선원을 영상 해상도 16.3 cm(각도 분해능 $9.26^{\circ}$)으로 영상화할 수 있음을 확인하였다.