• 제목/요약/키워드: Large optics

검색결과 351건 처리시간 0.029초

유전체 쐐기에 의한 물리광학해를 수정하기 위한 새 로운 급수 (Fast Converging Correction Current for the Physical Optics Edge Diffraction by a dielectric Wedge)

  • 전재영;서종화;나정웅
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.877-880
    • /
    • 1999
  • A rigorous formulation is suggested〔l,2,3〕 in solving the scattering of plane waves by a dielectric wedge. Correcting surface currents are expanded in a Neumann series of fractional orders to meet the edge condition of static limit〔4〕. For the better converging series, the modified Neumann series satisfying the static limit edge condition and the radiation condition are suggested here for the surface currents having two different wave numbers of air and dielectric〔4〕. This representation gives accurate solutions over the whole region including the grazing incidence of the plane waves upon the dielectric wedge of large permittivities.

  • PDF

광 귀환에 의한 erbium 첨가 광섬유 증폭기의 이득과 ASE 스펙트럼 안정화 (Gain and spectra stabilization in erbium-doped fiber amplifier with optical feedback)

  • 김호삼;박희갑
    • 한국광학회지
    • /
    • 제5권2호
    • /
    • pp.291-297
    • /
    • 1994
  • Erbium첨가 광섬유 증폭기에서 증폭된 자연방출광(ASE) 출력의 일부를 대역투과 파장 필터를 거쳐 입력단으로 루프 귀환시켜 광증폭기를 특정 파장에서 발진시킴으로써 신호광에 대한 증폭 이득을 일정치에 고정시켰다. 증폭 이득과 ASE 출력 스펙트럼은 광증폭기가 발진하는한 입력광 power나 펌프광 power의 변화에 대하여 무관하였으며 귀환 루프의 손실에만 의존하였다. 또한 광증폭기에 저속으로 변조된 대신호가 입사하는 경우에도 이득포화에 의한 파형 왜곡없이 증폭이 가능하였다.

  • PDF

Design of a Plasmonic Switch Using Ultrathin Chalcogenide Phase-change Material

  • Lee, Seung-Yeol
    • Current Optics and Photonics
    • /
    • 제1권3호
    • /
    • pp.239-246
    • /
    • 2017
  • A compact plasmonic switching scheme, based on the phase change of a thin-film chalcogenide material ($Ge_2Sb_2Te_5$), is proposed and numerically investigated at optical-communication wavelengths. Surface plasmon polariton modal analysis is conducted for various thicknesses of dielectric and phase-change material layers, and the optimized condition is induced by finding the region of interest that shows a high extinction ratio of surface plasmon polariton modes before and after the phase transition. Full electromagnetic simulations show that multiple reflections inside the active region may conditionally increase the overall efficiency of the on/off ratio at a specific length of the active region. However, it is shown that the optimized geometrical condition, which shows generally large on/off ratio for any length of active region, can be distinguished by observing the multiple-reflection characteristic inside the active region. The proposed scheme shows an on/off switching ratio greater than 30 dB for a length of a few micrometers, which can be potentially applied to integrated active plasmonic systems.

펨토초 레이저를 이용한 형상 측정용 비동일 광경로 저결 맞음 간섭계 (Unequal-path Low-coherence Interferometry Using Femtosecond Pulse Lasers for Surface-profile Metrology)

  • 오정석;김승우
    • 한국정밀공학회지
    • /
    • 제23권9호
    • /
    • pp.102-110
    • /
    • 2006
  • We discuss two possibilities of using femtosecond pulse lasers as a new interferometric light source for enhanced precision surface-profile metrology. First, a train of ultra-fast laser pulses yields repeated low temporal coherence, which allows unequal-path scanning interferometry, which is not feasible with white light. Second, the high spatial coherence of femtosecond pulse lasers enables large-sized optics to be tested in nonsymmetric configurations with relatively small-sized reference surfaces. These two advantages are verified experimentally using Fizeau and Twyman-Green type scanning interferometers.

Microfluidic Flow Cytometry: Principles of Cell Analysis and Applications

  • Shin, Se-Hyun
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권2호
    • /
    • pp.1-6
    • /
    • 2006
  • Microsystems create new opportunities for conventional cell analysis by combining microfluidics and flow cytometry. This article describes recent developments in conventional flow cytometers and related microfluidic flow cytometers to detect, analyze, and sort cells or particles. Flow cytometry strongly consisted of fluidics, optics and electronics requires a large space to equip various components, which are mostly the fluidic components such as compressor, fluid handling system. Adopting microfluidics into flow cytometry enables volume- and power-efficient, inexpensive and flexible analysis of particulate samples. In this paper, we review various efforts that take advantage of novel techniques to build microfluidic cell analysis systems with high-speed analytical capability. Highly integrated microfluidic cytometry shows great promise for basic biomedical and pharmaceutical research, and robust and portable point-of-care devices could be used in clinical settings.

  • PDF

대면적 롤금형 미세패턴 가공공정 기술 (Micro Pattern Machining on Larger Surface Roll Molds)

  • 송기형;이동윤;박경희;이석우;김현철;제태진
    • 한국기계가공학회지
    • /
    • 제11권2호
    • /
    • pp.7-12
    • /
    • 2012
  • In order to cope with the requirements of smaller patterns, larger surfaces and lower costs in the fields of displays, optics and energy, greater attentions are now being paid to the development of micro-pattern machining technology. Compared with flat moulds, large drums with micro patterns (roll moulds) have the advantages of short delivery, ease of manufacturing larger surfaces, and continuous moulding. This paper introduced the machining process technology of the roll moulds for display industry. The environmental effects were discussed and the importance of temperature maintenance was experimentally emphasized. The real time monitoring system for micro machining was introduced. A commercial solution was used to simulate the micro grooving and a deformation model of micro machined pattern was finally introduced.

알루미늄 핀-조인트를 사용한 마이크로 미러의 제작과 측정 (Fabrication and Experiment of Micromirror with Aluminum Pin-joint)

  • 지창현;김용권
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권8호
    • /
    • pp.487-494
    • /
    • 2000
  • This paper describes the design, fabrication and experiments of surface-micromachined aluminum micromirror array with hidden pin-joints. Instead of the conventional elastic spring components as connection between mirror plate and supporting structure, we used pin-joint composed of pin and staples to support the mirror plate. The placement of pin-joint under the mirror plate makes large active surface area possible. These flexureless micromirrors are driven by electrostatic force. As the mirror plate has discrete deflection angles, the device can be ap;lied to adaptive optics and digitally-operating optical applications. Four-level metal structural layers and semi-cured photoresist sacrificial layers were used in the fabrication process and sacrificial layers were removed by oxygen plasma ashing. Static characteristics of fabricated samples were measured and compared with modeling results.

  • PDF

쇄기형 유전체에 의한 전자파의 회절, III부: Neumann 전개된 전원에 의한 수정 (Diffraction of Electromagnetic Waves by a Dielectric Wedge, Part III: Correction by Neumann-Expanded Source)

  • 김세윤;라정웅;신상영
    • 대한전자공학회논문지
    • /
    • 제25권9호
    • /
    • pp.1027-1038
    • /
    • 1988
  • This paper, the last part of these three companion papers treated the electromagnetic diffraction by a dielectric wedge, presents the correction to the physical optics approcomation by the sheet currents of the Neumann expansion. Those expansion coefficients obtained by solving dual series equation amenable to simple numerical calculation may provide the asymprotically corrected solution. The validity of this result, satisfying both the edge condition near the tip of the dielectric wedge and the boundary condition along dielectric interfaces, is assured by approach of the corrected diffraction pattern to that of a perfectly conducting wedge for large permittivity of dielectric wedge.

  • PDF

광결합 변화에 의해 부모드 억제된 협대역 수직 결합기 파장 여과기 (Coupling variation induced side-lobe suppressed narrowband vertical coupler wavelength filter)

  • 한상국
    • 한국광학회지
    • /
    • 제8권6호
    • /
    • pp.506-509
    • /
    • 1997
  • 수직결합 구조의 방향성결합기 파장여과기에 진행방향으로 광결합력의 변화를 도입으로서 부엽이 감소하고 동시에 통과대역폭이 감소하는 새로운 구조의 파장여과기를 제안하였다. 광결합 구조로서는 결합정도가 반정현 모양인 분포결합과 최소의 결합을 일정하게 유지하는 느린결합을 연계하여 사용하였다. 모의실험 결과 중심파장 1.5507$\mu\textrm{m}$에서 3 dB 통과대역폭은 약 1.5 nm이고 부엽 억제비는 20 dB이상으로서 기존의 일정한 결합구조의 파장여과기에 비해 2배 이상 증가함을 알 수 있었다. 파장역다중을 위해 두 개의 파장여과기를 단일집적한 2채널 역다중기를 제안하고 동작특성을 모의실험하였다.

  • PDF

Truncated DCPC를 이용한 저배율 태양광 모듈 개발 (Development of Low Concentrated Photovoltaic using a Truncated DCPC)

  • 이동길;김양규;이광훈;장원근;박영식
    • Current Photovoltaic Research
    • /
    • 제1권1호
    • /
    • pp.33-37
    • /
    • 2013
  • LCPV modules under 5 suns consist of reflective optics and receiver modules, similar to a typical fixed concentration PV module. If they are to be used as a compound parabolic concentrator, which is filled with a dielectric material, a compact plate structure of the fixed CPV can be designed and built at a large acceptance angle. These types of flat-$plate{\mu}$-LCPV modules are suitable for building integrated photovoltaic modules, facade applications, mobile devices, and small home appliances. Therefore, in this study, the possibilities for other application devices were studied and presented by designing and fabricating LCPCs for CPV modules.