• 제목/요약/키워드: Large generator

검색결과 632건 처리시간 0.03초

대형 회전기의 절연진단결과와 경년 특성과의 상관관계에 관한 연구 (A Study on the Correlation between the Lapse of Time and Diagnostic Test Results of Large Rotating Machine Windings)

  • 김광화;조연옥;선종호;김영배;류희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.966-968
    • /
    • 1992
  • We have done the insulation diagnostic test of generators in domestic five power plants since 1987 and tested A.C. current increasing rate($\Delta$I), $\Delta$tan$\delta$ and partial discharge in generator winding insulation. This study is described the correlation between nondestructive result(A.C. current increasing rate, $\Delta$tan$\delta$ and partial discharge) and lapse of time in generators.

  • PDF

단독계통에서 풍력발전기의 주파수 영향 분석 (The Effect of Wind Turbine fe the Frequency of Isolated Systems)

  • 황교익;전영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.143-145
    • /
    • 2005
  • There has been increasing interest in the renewable energies. Wind energy is worldwide number one renewable energy from the installed capacity viewpoint. Most of the power systems utilizing wind energy are connected to other large systems. In such integrated systems, frequency control is not big issue. Rut the situation is different in isolated systems like Korean power system. It is important to assess appropriate capacity of wind power for our system, as it affects the system operation and control strategy. In this paper we made it clear the relationship among generator inertias, governor droop, system damping and wind energy capacity.

  • PDF

소형 풍력발전시스템의 출력제어 (Power Control of Small Wind Power System)

  • 김철호;이현채;서영택;조환기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1066_1067
    • /
    • 2009
  • Wind power is one of most promising renewable energy. The output capacity of large wind turbine has been increased for off-shore application. Number of installation of small wind turbine also has been increased for the stand-alone and off-grid application of remote area and recently small wind turbine equipped with lamp on the pole is used for street lamp. Maximum wind energy must be extracted by wind turbine within rated wind speed. Power must be controlled to protect the system such as blade, generator, and power system above the rated wind speed. In this paper, small wind power system of 800W rating for battery charging is implemented and output power control by furling system is verified at wind tunnel test.

  • PDF

조류발전 이중여자발전기의 CRPWM 컨버터 히스테리리스 밴드 크기 최적화에 관한 연구 (A Study of Using Optimal Hysteresis Band Amplitude of CRPWM Converter for DFIG of Tidal Current)

  • 기경현;이용식;정성원;김재현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.507_508
    • /
    • 2009
  • As a result of environmental concerns, renewable energy systems are rapidly increasing and particularly tidal current is a potential source of energy. In accordance with a large-capacity trend, doubly-fed induction generator is applied such as wind farms and tidal systems. In this paper, Optimal hysteresis band amplitude of CRPWM Converter is determined for improving rotor current waveform and electrical quality.

  • PDF

A New Required Reserve Capacity Determining Scheme with Regard to Real time Load Imbalance

  • Park, Joon Hyung;Kim, Sun Kyo;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.511-517
    • /
    • 2015
  • Determination of the required reserve capacity has an important function in operation of power system and it is calculated based on the largest loss of supply. However, conventional method cannot be applied in future power system, because potential grid-connected distributed generator and abnormal temperature cause the large load imbalance. Therefore this paper address new framework for determining the optimal required reserve capacity taking into account the real time load imbalance. At first, we introduce the way of operating reserve resources which are the secondary, tertiary, Direct Load Control (DLC) and Load shedding reserves to make up the load imbalance. Then, the formulated problem can be solved by the Probabilistic Dynamic Programming (PDP) method. In case study, we divide two cases for comparing the cost function between the conventional method and the proposed method.

Practical Methodology of the Integrated Design and Power Control Unit for SHEV with Multiple Power Sources

  • Lee, Seongjun;Kim, Jonghoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.353-360
    • /
    • 2016
  • Series hybrid electric vehicles (SHEVs) having multiple power sources such as an engine- generator (EnGen), a battery, and an ultra-capacitor require a power control unit with high power density and reliable control operation. However, manufacturing using separate individual power converters has the disadvantage of low power density and requires a large number of power and signal cable wires. It is also difficult to implement the optimal power distribution and fault management algorithm because of the communication delay between the units. In order to address these concerns, this approach presents a design methodology and a power control algorithm of an integrated power converter for the SHEVs powered by multiple power sources. In this work, the design methodology of the integrated power control unit (IPCU) is firstly elaborately described, and then efficient and reliable power distribution algorithms are proposed. The design works are verified with product-level and vehicle-level performance experiments on a 10-ton SHEV.

SODAR관측을 통해 분석한 도심지 상층의 풍력자원 특성 (The Characteristics of Wind Power Resource in Urban from SODAR Observation)

  • 이화운;박순영;김동혁;전원배;차영민;김현구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.557-560
    • /
    • 2009
  • When we urgently need to develop and supply an alternative energy, wind power is growing with much interest because it has relative low cost of power and area of tower. To estimate the wind power resource, it is necessary to make an observation first. Although the large wind falm and resources are near coast and mountain area, the wind energy in urban area has the strong thing of direct access to power generator. In this study, we estimate the probability of wind energy above urban area using SODAR data, which is located at the top of the tall building (140m).

  • PDF

NREL Phase VI 풍력발전기 저주파 소음방사 특성 (Characteristics of Low Frequency Aero-acoustic Noise Radiation for a Wind Turbine Generator of NREL Phase VI)

  • 모장오;김병윤;류병남;이영호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.504-507
    • /
    • 2009
  • The purpose of this work is to predict the low frequency aero-acoustic noise generated from the horizontal axis wind turbine, NREL Phase VI using large eddy simulation and Ffowcs-Williams and Hawkings model provided in the commercial code, FLUENT. Calculated aerodynamic performances such as shaft torque and power are compared with experimentally measured value. Performance results show a good agreement with experimental data within about 0.8%. If the distance by two times is changed from 32D to 64D toward the downstream region, sound pressure level is reduced by about 6.4dB.

  • PDF

183MW 대용량 동기기 구동 LCI 시스템 기동운전 분석 및 시험 (Start-up Analysis and Commissioning Test of LCI System for 183MW Large Synchronous Machine)

  • 류호선;차한주
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.626-631
    • /
    • 2013
  • Gas turbine systems are applied extensively in energy supplies to cover peak load requirements. The gas turboset must be accelerated by starting device up to 60%~80% of rated speed to ignite the gas turbine. Recently, the most favorable and economical starting device is the LCI(Load Commutated Inverter). The LCI runs up the gas turboset by feeding the generator as a synchronous motor. In this paper, we discuss in detail the driving principles and features of 183MW gas turbine system. During field application of LCI system, many tests have been conducted and the results were described in this paper. The test results will be considered as the important resources for development in future.

실시간 디지털 시뮬레이터(Hypersim)을 이용한 이차적 전압제어 제어기 구현 (The realization of secondary voltage controller using real-time digital simulator(Hypersim))

  • 김봉식;서상수;이병준;송인준;신정훈;김태균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.269-271
    • /
    • 2006
  • In power system, the reactive power is closely associated with voltage. In addition Reactive power has localized characteristic. Recently wide area blackout caused by reactive power imbalance. Therefore it is important to control reactive power considering its characteristic. Until now maintenance of system voltage has been controlled by shunt compensation rather than generators. However because of a large time-constant, shunt compensators are difficult to manage disturbances immediately. In addition shunt compensation has discrete characteristic, which make disturbances in system. In this paper we studied the voltage maintenance method of local buses by controlling the reactive power output of a generator which is closely related a load bus in addition the proposed method was verified by test system.

  • PDF